Search results for "텔레@UPCOIN24*$코인믹싱코인전송대행"
-
DTC1-A/M-2O, DIN Rail Mount Dual Transmitter Multirange Input, 85-265VAC, Dual 4-20mA Outputs
Free Aus Post Shipping for $300 spendFastron DTC1-A/M-2O, DIN Rail Mount Dual Transmitter Multirange Input, 85-265VAC, Dual 4-20mA Outputs Optional converter function 2 Input 1 Output, and 1 Input Two Output Versions available Optional 60 Segment Multi Pattern Program Control feature 4-digit display. Suit most industries including Temperature, Humidity, Pressure (0.5s response) CE Approved Each unit needs just 22.5mm width Din Rail space EC Compliant (Details) Various specials available for unique applications. Specification Fastron Part Number DTC1-A/M-2O Control Output 2 x 4-20mA outputs Input Multirange K/J/R/S/B/E/T/Linear Voltage Current(Optional)/N/W1/W2/Pt100 Alarm Relay 3A(Resistive), 1A(Inductive load cos ??=0.4), 240VAC/30VDC Options Dual Output Mounting Style 22.5 x 75mm Din Rail Mount Supply Voltage 85 - 265VAC Termination Style Screw Weight 230g Factory Pack Qty 1 CE Yes ?? Selection Chart PWM Control Wiring Datasheet DTC1 Brochure DTC1User Manual DTC1 User Manual Comms versions Alarm Table DTC1 (Program Control Version) User Manual
-
FTCK-Transmitter-0-300-420-24, Type K , 4-20mA Transmitter, 0 to 300 Deg C, 24VDC Supply
Fastron Type K Thermocouple FTCK-Transmitter-0-300-420-24, Type K , 4-20mA Transmitter, 0 to 300 Deg C, 24VDC Supply Class A Accuracy Steel Insulated Cable Low Long Term Drift Rated for 0 to 220 Deg C Max Spring Cable Connection 60mm Jaw Clip Specification Fastron Part Number FTCK-Transmitter-0-300-420-24 Sensor Type Type K to 4-20mA Transmitter No of Wires 2 Shaft Length N/A Shaft Thickness N/A Accuracy Class A Temperature Range 0 to 300 Deg C Span/ Zero Adjustment YES Weight 50g Factory Pack Qty 1
$15.00
$17.70 inclGST -
PD9, Communication Converter RS485 Modbus RTU to Modbus TCP, 5-36VDC Supply
Lumel PD9, Communication Converter RS485 Modbus RTU to Modbus TCP, 5-36VDC Supply USB/RS485/Ethernet Comms as standard Modbus TCP/RTU Protocols 5-36VDC Supply Features : 1 RS485 Ports or 1 x Ethernet Port, 1 x USB service Port Free user config software Specification Lumel Part Number PD9 Functions Communication Datalogger and Alarm Unit Supply Voltage 5-36VDC Protocols TCP/RTU Communication Ports RS485Ethernet RS485/RS232 Baud Rate 1200,2400,4800,9600,19200,38400,57600,115200 bit/s USB Baud Rate 115200 bit/s Ethernet Baud Rate 10,100 Mbit/s Real Time Clock 1min/month (30ppm) Isolation 3.5kV Weight 250g Factory Pack Qty 1 EU Directives EN61000, EN61010 Safety Protection Class II Enclosure Material PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP20 Operating Temperature -20 →+70 °C Datasheet User Manual
$249.50
$294.41 inclGST -
FPC1-40-04C-24VAC/DC, 4 Pole 4 x SPST NC, Modular Contactor 440VAC 40 Amp 50/60Hz, 24VAC/DC Coil Voltage, Hum Free
Fastron, FPC1-40-04C-24VAC/DC, 4 Pole 4 x SPST NC, Modular Contactor 440VAC 40 Amp 50/60Hz, 24VAC/DC Coil Voltage, Hum Free Features 40 Amp (rms) @ 440VAC DIN Rail Mount Slim package CE Compliant to IEC 60664 IP20 Specification Fastron Part Number FPC1-40-04C-24VAC/DC Switching Type 4 x SPST NC Approvals CE Coil Voltage 24VAC/DC Load Current (RMS/DC) 40 Amp (rms) @ 440VAC Special Feature Hum Free Mounting Style DIN Rail Mount Load Voltage Range 440VAC, 50/60Hz Isolation 4kV Termination Style Screw Unit Weight 295g Factory Pack Qty 20 Datasheet Relay Datasheet Auxiliary Contacts Selection Guide
$65.00
$76.70 inclGST -
Xmer CT Split 125/50SC 300/5 Class 0.5 2.5VA, 55 x 85mm Aperture
Free Aus Post Shipping for $300 SpendXmer CT Split Xmer CT Split 125/50SC 300/5 Class 0.5 2.5VA, 55 x 85mm Aperture Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Rishabh Part Number Xmer CT Split 125/50SC 300/5 Class 0.5 2.5VA Technology Split Core AC Current Transformer Ratio 300/5 Aperture Size 55 x 85mm VA Rating 2.5VA Accuracy Class Class 0.5 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -30°C / 85°C Continuous Current (max) 300Amp x 1.2 Termination Style Screw Unit Weight 1.25kg Factory Pack Qty 9 Datasheet Product Datasheet
-
750134, E-STOP Safety Relay 48-240VAC/DC, 3 x NO Safety Contacts, 1 x NC Auxiliary Contact, PNOZ s4 48-240VACDC 3 n/o 1 n/c
Pilz 750134, E-STOP Safety Relay 48-240VAC/DC, 3 x NO Safety Contacts, 1 x NC Auxiliary Contact, PNOZ s4 48-240VACDC 3 n/o 1 n/c Safety Relay for Monitoring E-STOP Pushbuttons, safety gates and light barriers. Safety Features: Positive guides relay outputs, 3 x NO Safety Contacts, 1 x NC Auxiliary Contact Connection options for: E-Stop Pushbutton Safety Gate limit switch Reset button Light barriers LED Indicator for; Status channel 1/2 Supply Voltage Plug In connection terminals (cage clamp terminal or screw terminal) Redundant Circuit with in built monitoring Failsafe operation in case of component failure Correct Open/Close Operation is tested automatically in each on-off cycle Specification Pilz Part Number 750134, E-STOP Safety Relay PNOZ s4 48-240VACDC 3 n/o 1 n/c Function E-Stop Relay for E-stop, Gate or Lighting Supply Voltage 48 - 240 VAC/DC Relay Outputs 3 x NO Safety Contacts, 1 x NC Auxiliary Contact maximum Relay Current Safety Contacts 6 Amp, Auxiliary Contact 4 Amp Switch on Delay 340ms Delay on Energisation 10ms Termination Style Screw Weight 250g Certification UL Factory Pack Qty 1 Application Certification In accordance with EN 60947-5-1, EN 60204-1 and VDE 0113-1 Applications 2 in accordance with IEC/EN 61131-2 Protection rating IP40 (Front), IP20 (Rear) Datasheet Product Datasheet User Manual
$697.00
$822.46 inclGST -
Xmer CT Split 105/50SC 100/5 Class 1 1.5VA, 43 x 55mm Aperture
Free Aus Post Shipping for $300 SpendXmer CT Split 105/50SC 100/5 Class 1 1.5VA, 43 x 55mm Aperture Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Rishabh Part Number Xmer CT Split 105/50SC 100/5 Class 1 1.5VA Technology Split Core AC Current Transformer Ratio 150/5 Aperture Size 43 x 55mm VA Rating 1.5VA Accuracy Class Class 1 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -30°C / 85°C Continuous Current (max) 150Amp x 1.2 Termination Style Screw Unit Weight 800g Factory Pack Qty 9 Datasheet Product Datasheet
-
H-15-2-24, Split Core Hall Effect DC Current Transducer, 0-15 Amp DC, 4-20mA unipolar output, 31mm aperture, 24VDC supply
Free Aus Post Shipping for $300 SpendH-15-2-24, Split Core Hall Effect DC Current Transducer, 0-15 Amp DC, 4-20mA unipolar output, 31mm aperture, 24VDC supply Compact and versatile Split Core DC current sensor, 0-100 Amp DC, 4-20mA Unipolar Output Features ⌀31mm Aperture Split Core DC Unipolar Measurement 4-20mA analogue output Busbar, or DIN Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Mount Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number H-15-2-24 Technology DC Hall Effect Current Transducer with Process Output ROHS Yes Supply Voltage 24VDC Nominal Current (DC) 0-15 Amp Response Time < 200mS Output Unipolar 4-20mA Analogue Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Screw Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet
-
Rish Con M+ CM44111411, Class 0.5 Power Transducer 4 wire, 100-600V L-L, 1 or 5Amp measurement, 85-285VAC/DC Aux Supply, 4 x Analogue -20-20mA/4-20mA/-10-10V Outputs, USB Programming Port, Modbus RTU Comms, without display
Rishabh Rish Con M+ CM44111411, Class 0.5 Power Transducer 4 wire, 100-600V L-L, 1 or 5Amp measurement, 85-285VAC/DC Aux Supply, 4 x Analogue -20-20mA/4-20mA/-10-10V Outputs, USB Programming Port, Modbus RTU Comms, without display Measures Active Power/Phase Angle/Power Factor Measures Apparent/Reactive/Active Power Analogue output setting 0-20mA/4-20mA/0-10V (Programmable) Free Program Software 300mS response time PC 94 UL V0 Input Voltages, Current or Power Measurements can be converted to insulated 4 to 20 mA DC output (for direct current output type) Each unit needs just 122.5 x 66 x 106.5mm depth DIN Rail cabinet space Specification Rishabh Part Number Rish Con CM44111411 Functions Active Power/Phase Angle/Power Factor Transducer 4 wire Measurement Output 4 x 4-20mA/0-20mA/0-10V User Selectable and Programable Relay Output N/A Relay Type Voltage Free Contact, 0.5 Amp @ 250VAC Input 100 - 600VAC L-L 50/60Hz Overload (Continuous) 120% Overload (1 second) 150% Operating Temperature -10 - 55°C Supply Voltage 85-285VAC/DC Accuracy 0.2% Current, Voltage (0.5% Power) Response Time 300mS Termination Style Screw Mounting Style DIN Rail Mount Mounting Size 122.5 x 66 x 106.5mm Safety IP40/IP20 EN60529 Protection Class II EN61010 Weight 400g Factory Pack Qty 1 Datasheet Product Datasheet Product User Manual Technical Support Rish Con P setup procedure blog Brand Comparison to Iskra UMT540 or MT540 Series
$589.00
$695.02 inclGST -
Rish Xmer Splt Core 195/80 2500/5 Split Core CT Class 1 30VA, 85 x 172mm Aperture
Rish Xmer Splt Core Split Core 2500/5 Amp 195/80 Class 1, 30VA Series Current Transformer, 85 x 172mm Aperture Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Electronics Part Number Rish Xmer Split Core 2500/5 195/80 Technology Split Core AC Current Transformer Ratio 2500/5 Aperture Size 172 x 85mm VA Rating 30VA Accuracy Class Class 1 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -25°C / 40°C Continuous Current (max) Ipn x 1.2 Termination Style Screw Unit Weight 2kg Factory Pack Qty 9 Datasheet Product Datasheet
$383.00
$451.94 inclGST -
Rish Con M+ CM44111211, Class 0.5 Power Transducer 4 wire, 100-600V L-L, 1 or 5Amp measurement, 85-285VAC/DC Aux Supply, 2 x Analogue -20-20mA/4-20mA/-10-10V Outputs, 2 x Relay Outputs, USB Programming Port, Modbus RTU Comms, without display
Rishabh Rish Con M+ CM44111211, , Class 0.5 Power Transducer 4 wire, 100-600V L-L, 1 or 5Amp measurement, 85-285VAC/DC Aux Supply, 2 x Analogue -20-20mA/4-20mA/-10-10V Outputs, 2 x Relay Outputs, USB Programming Port, Modbus RTU Comms, without display Measures Active Power/Phase Angle/Power Factor Measures Apparent/Reactive/Active Power Analogue output setting 0-20mA/4-20mA/0-10V (Programmable) Free Program Software 300mS response time PC 94 UL V0 Input Voltages, Current or Power Measurements can be converted to insulated 4 to 20 mA DC output (for direct current output type) Each unit needs just 122.5 x 66 x 106.5mm depth DIN Rail cabinet space Specification Rishabh Part Number Rish Con M+ CM44111211 Functions Active Power/Phase Angle/Power Factor Transducer 4 wire Measurement Output 2 x 4-20mA/0-20mA/0-10V User Selectable and Programable Relay Output 2 Relay Type Voltage Free Contact, 0.5 Amp @ 250VAC Input 100 - 600VAC L-L 50/60Hz Overload (Continuous) 120% Overload (1 second) 150% Operating Temperature -10 - 55°C Supply Voltage 85-285VAC/DC Accuracy 0.2% Current, Voltage (0.5% Power) Response Time 300mS Termination Style Screw Mounting Style DIN Rail Mount Mounting Size 122.5 x 66 x 106.5mm Safety IP40/IP20 EN60529 Protection Class II EN61010 Weight 400g Factory Pack Qty 1 Datasheet Product Datasheet Product User Manual Technical Support Rish Con P setup procedure blog Brand Comparison to Iskra UMT540 or MT540 Series
$629.00
$742.22 inclGST -
Rish Xmer 155/80 1500/5 Split Core CT Class 1 30VA, 85 x 125mm Aperture
Heavy Item - No Free ShippingRishabh Xmer CT Split 155/80 1500/5 Class 1 30VA Series Current Transformer Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Rishabh Part Number Rish Xmer 155/80 1500/5 SCCT Class 1 30VA Technology Split Core AC Current Transformer Ratio 1500/5 Aperture Size 85 x 125mm VA Rating 30VA Accuracy Class Class 1 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -30°C / 85°C Continuous Current (max) 1500Amp x 1.2 Termination Style Screw Unit Weight 1000g Factory Pack Qty 9 Datasheet Product Datasheet