Trent NBR-CH14/UQ/20A/690V, gR Semiconductor Fuse, 20 Amp, 51x14mm 690V Semiconductor I²t Fuse Cartridge Style 51 x 14mm
Features
Cylindrical Standard Fuses Sizes
Wide Range of I²t
Ratings up to 125 Amp
Quick Release with RT18-63L fuse holder
DIN Rail Mount with RT18-63L fuse holder
Compatible with all 58 x 21mm fuse holders
IEC Standard 60269.1 AND 4
690 V Voltage Rating complying with IEC 33
Applications
Solid State Relay Switchboards
Bridge rectifier Fusing
Protection of High Powered Semiconductors according to I²t
Short Circuit Protection
DC or AC Motor I²t Protection
Battery Fuse
Specification
Trent Part Number
NBR-CH14/UQ/40A/690V
Fuse Type
I²t gR Class
Nominal Voltage
690VAC @ 50Hz
I²t Rating (Pre-Arcing)
180 A²/s
Nominal Current (RMS + DC)
20 Amp
Tested Breaking Capacity
200kA @ 690VAC
Dimensions
51 x 14mm
Fuse Holder
RT18-63L
Mounting Style
Requires fuse holder
Operating Temperature Range
-40°C / 125°C
Watt Loss
8W
DC Breaking Capacity
50kA
Unit Weight
60g
Factory Pack Qty
10
Datasheet
Product Datasheet
Compatible Fuse Holder
RT18-63L
Trent NBR-CH14/UQ/10A/690V + RT18-63L Series 10 Amp 690V Semiconductor I²t gR Fuse & Din Rail Fuse Holder Cartridge Style 51 x 14mm
Features
Cylindrical Standard Fuses Sizes
Wide Range of I²t
Ratings up to 63 Amp
Quick Release with RT18-63L fuse holder
DIN Rail Mount with RT18-63L fuse holder
Compatible with all 51 x 14mm fuse holders
IEC Standard 60269.1 AND 4
690 V Voltage Rating complying with IEC 33
Applications
Solid State Relay Switchboards
Bridge rectifier Fusing
Protection of High Powered Semiconductors according to I²t
Short Circuit Protection
DC or AC Motor I²t Protection
Battery Fuse
Specification
Trent Part Number
NBR-CH14/UQ/10A/690V + RT18-63L
Fuse Type
I²t gR Class
Nominal Voltage
690VAC @ 50Hz
I²t Rating (Pre-Arcing)
22 A²/s
Nominal Current (RMS + DC)
10 Amp
Tested Breaking Capacity
200kA @ 690VAC
Dimensions
108mm x 77mm x 22mm
Fuse Holder
RT18-63L
Mounting Style
Din Rail Mount
Operating Temperature Range
-40°C / 125°C
Watt Loss
13.8W
DC Breaking Capacity
50kA
Unit Weight
42g
Factory Pack Qty
10
Datasheet
Product Datasheet
RT18-63L
Trent NBR-FR22GR69V32T + RT18-125L Series 32 Amp 690V Semiconductor I²t gR Fuse & DIn Rail Fuse Holder Cartridge Style
Features
Cylindrical Standard Fuses Sizes
Wide Range of I²t
Ratings up to 32 Amp
Quick Release with RT18-125L fuse holder
DIN Rail Mount with RT18-125L fuse holder
Compatible with all 58 x 21mm fuse holders
IEC Standard 60269.1 AND 4
690 V Voltage Rating complying with IEC 33
Applications
Solid State Relay Switchboards
Bridge rectifier Fusing
Protection of High Powered Semiconductors according to I²t
Short Circuit Protection
DC or AC Motor I²t Protection
Battery Fuse
Specification
Trent Part Number
NBR-FR22GR69V32T + RT18-125L
Fuse Type
I²t gR Class
Nominal Voltage
690VAC @ 50Hz
I²t Rating (Pre-Arcing)
605 A²/s/s
Nominal Current (RMS + DC)
32 Amp
Tested Breaking Capacity
200kA @ 690VAC
Dimensions
123 x 76 x 37.5mm
Fuse Holder
RT18-125L
Mounting Style
Din Rail Mount
Operating Temperature Range
-40°C / 125°C
Watt Loss
22.8W
DC Breaking Capacity
50kA
Unit Weight
60g
Factory Pack Qty
10
Datasheet
RT18-125L
Datasheet
Fastron FES2151-FD-420T, Split Core Solid Core AC Current Transducer, Multirange 100A,150A, 200A, Self Powered, True RMS 4-20mA Output. 1% Accuracy (FCS2151-SD-420T)
Compact and versatile current switches for detection of AC Currents, Multirange 0-100Amp, 0-150Amp, 0-200Amp via jumper, 4-20mA True RMS output
Features
True RMS 4-20mA output
Multirange selector
Panel mounting
Eliminates insertion loss
Isolated plastic case recognised according to UL94-V0
Advantages
Highly accurate low current measurement down to 1Amp
High isolation between primary and secondary circuits
Easy installation
Applications
Fault Detection
Motor or Fan Protection
Application Domain
Energy and Automation
Specification
Fastron Part Number
FES2151-FD-420T
Technology
Solid Core Solid Core AC Current Transducer
Range
0-100Amp, 0-150Amp, 0-200Amp via jumper
Supply Voltage
Self Powered
Load Current (RMS)
1Amp to 200 Amp
Output
4-20mA True RMS
Isolation
2kV (AC, 50Hz, 1 min)
Bandwidth
50/60Hz
Mounting Style
Panel Mount
Operating Temperature Range
-25°C / 70°C
Accuracy
1%
Termination Style
Screw Terminals
Unit Weight
200g
Certifications
UL E320368, CE, Rohs compliant
Datasheet
Product Datasheet
Installation Guide
Fastron FES521-FD-V10,Solid Core AC Current Transducer, Solid Core Multirange 0-10A,20A, 50A, Self Powered, Average RMS 0-10V Output. 1% Accuracy (FCS521-SD-V10)
Compact and versatile current switches for detection of AC Currents, Multirange 0-10Amp, 0-20Amp, 0-50Amp via jumper, 0-10V True RMS output
Features
Average RMS 0-10V output
Multirange selector
Panel mounting
Eliminates insertion loss
Isolated plastic case recognised according to UL94-V0
Advantages
Highly accurate low current measurement down to 1Amp
High isolation between primary and secondary circuits
Easy installation
Applications
Fault Detection
Motor or Fan Protection
Application Domain
Energy and Automation
Specification
Fastron Part Number
FES521-FD-V10
Technology
Solid Core Solid Core AC Current Transducer
Range
0-10Amp, 0-20Amp, 0-50Amp via jumper
Supply Voltage
Self Powered
Load Current (RMS)
1Amp to 50 Amp
Output
0-10V Average RMS
Isolation
2kV (AC, 50Hz, 1 min)
Bandwidth
50/60Hz
Mounting Style
Panel Mount
Operating Temperature Range
-25°C / 70°C
Accuracy
1%
Termination Style
Screw Terminals
Unit Weight
200g
Certifications
UL E320368, CE, Rohs compliant
Datasheet
Product Datasheet
Installation Guide
Fastron FES2151-FD-V10, Solid Core AC Current Transducer, Multirange 0-100A,150A, 200A, Self Powered, Average RMS 0-10V Output. 1% Accuracy (FCS2151-SD-V10)
Compact and versatile current switches for detection of AC Currents, Multirange 0-10Amp, 0-20Amp, 0-50Amp via jumper, 0-10V True RMS output
Features
Average RMS 0-10V output
Multirange selector
Panel mounting
Eliminates insertion loss
Isolated plastic case recognised according to UL94-V0
Advantages
Highly accurate low current measurement down to 1Amp
High isolation between primary and secondary circuits
Easy installation
Applications
Fault Detection
Motor or Fan Protection
Application Domain
Energy and Automation
Specification
Fastron Part Number
FES2151-FD-V10
Technology
Solid Core Solid Core AC Current Transducer
Range
0-100Amp, 0-150Amp, 0-200Amp via jumper
Supply Voltage
Self Powered
Load Current (RMS)
1Amp to 200 Amp
Output
0-10V Average RMS
Isolation
2kV (AC, 50Hz, 1 min)
Bandwidth
50/60Hz
Mounting Style
Panel Mount
Operating Temperature Range
-25°C / 70°C
Accuracy
1%
Termination Style
Screw Terminals
Unit Weight
200g
Certifications
UL E320368, CE, Rohs compliant
Datasheet
Product Datasheet
Installation Guide
Fastron Electronics SCT-F24-100-33.33mA, 100Amp measurement, 33.33mA Output Split Core CT, Suitable for Porsche E-Performance Chargers
Features
Quick Release Split Core System
Cable Mount
33.33mA Amp Output
Self Powered
Rated System Voltage 0.60/3kV
0.9M Flying Leads
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
SCT-F24-100-33.33mA
Technology
Split Core AC Current Transformer
Ratio
100A/33.33mA
Aperture Size
ø 24 mm
VA Rating
N/A
Accuracy Class
Class 1
Output
33.33mA Amp (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
100Amp x 1.2
Termination Style
0.9M Flying leads
Unit Weight
100g
Factory Pack Qty
9
Datasheet
Product Datasheet
Application Notes
Installation Guide
Iskra IK40-30-24VAC/DC, 3 Pole 3 x SPST NO, Modular Contactor 440VAC 40 Amp, 24VAC/DC 40-500Hz Control Voltage, Hum Free
Features
40 Amp (rms) @ 440VAC
DIN Rail Mount
Changeover Contact
Slim package
CE Compliant to IEC 60664
IP20
Specification
Fastron Part Number
IK40-30-24VAC/DC
Switching Type
3 x SPST NO
Approvals
CE
Coil Voltage
24VAC/DC
Load Current (RMS/DC)
40 Amp (rms) @ 440VAC
Special Feature
Hum Free
Mounting Style
DIN Rail Mount
Load Voltage Range
440VAC 40-500Hz
Isolation
4kV
Termination Style
Screw
Unit Weight
295g
Factory Pack Qty
20
Datasheet
Contactor Datasheet
Fastron FES2151-FP-V5, Split Core AC Current Transducer, Multirange 100A, 150A, 200A, Average RMS 0-5V Output. 1% Accuracy (FCS2151-FP-V5)
Compact and versatile current switches for detection of AC Currents, Multirange 0-100Amp, 0-150Amp, 0-200Amp via jumper, 0-5V True RMS output
Features
True RMS 0-10V output
Multirange selector
Panel mounting
Eliminates insertion loss
Isolated plastic case recognised according to UL94-V0
Advantages
Highly accurate low current measurement down to 1Amp
High isolation between primary and secondary circuits
Easy installation
Applications
Fault Detection
Motor or Fan Protection
Application Domain
Energy and Automation
Specification
Fastron Part Number
FES2151-FP-V5
Technology
Split Core AC Current Transducer
Range
Selectable 0-100Amp, 0-150Amp, 0-200Amp via jumper
Supply Voltage
Self Powered
Load Current (RMS)
1Amp to 50 Amp
Output
0-5V Average RMS
Isolation
2kV (AC, 50Hz, 1 min)
Bandwidth
50/60Hz
Mounting Style
Panel Mount
Operating Temperature Range
-25°C / 70°C
Accuracy
1%
Termination Style
Screw Terminals
Unit Weight
200g
Certifications
UL E320368, CE, Rohs compliant
Datasheet
Product Datasheet
Installation Guide