VX2-UMNA-A2D2, Temp Controller, 48x96mm, 100-240VAC, Multirange Input, Relay Output, 2 Alarms, 2 x SV
Multirange Input (Programmable)
4-digit displays suit most industries including Temperature, Humidity, Pressure (0.5s response)
Drip-proof / Dust-proof IP65 (front panel only)
UL/CE Approved
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 60 mm depth panel space
EC Compliant
Specification
Hanyoung Nux Part Number
VX2-UMNA-A2D2
Control Output 1 (Heat)
Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)
Control Output 2 (Cool)
N/A
Input
Multirange Type K/J/E/T/R/B/S/L/N/U/W/PLII/PT100/JPT100/4-20mA/0-20mA/1-5V/0-5V/0-10V/0-50mV/0-100mV. Note for Direct Current Input please use 250 Ohm Resistor in Parallel to the input terminals.
Alarm
Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)
Option 1
2nd Alarm Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)
Option 2
2 x SV Input (2 Setpoint Selection/External Setting Input)
Mounting Style
48 x 96mm Panel Mount
Supply Voltage
85 - 265VAC
Termination Style
Screw
Weight
350g
Factory Pack Qty
1
ROHS
Yes
UL
Yes
CE
Yes
Datasheet
VX Series Brochure
VX Series Instruction Manual
Free Software
Hanyoung Nux TCS Software
Hanyoung Nux TCS Software User Manual
VX Series SB Driver (Windows 7) Not required for Windows 10 or 11
M-FRS3-C40-1000R-T2, MODULE ONLY 1000VDC Module for Surge Protection Device for Photovoltaic Systems, Type 2 (Class II) 40kA
Specifications
Trent part number
M-RS3-C40-1000R-T2 MODULE ONLY
Nominal Voltage Un
1000VDC
No of Poles
N/A
Category IEC / EN / VDE
Type 2 (Class II)
Location of use
String Box, Inverter, Sub Board Only
Protection modes
(+)-PE,(-)-PE,(+)-(-) PE
Additional Remote Contacts
YES NO/NC/COM
Protective element
MOV
No Fault/Fault Indication
Green Flag / Not Green Flag
Surge discharge rating
Per pole 40kA (8/20uS)9KA) Max, 20kA (8/20uS)9KA) Nominal
Internal protection and safety
Thermal disconnector in each MOV
Weight
420g
Standards
IEC614643-31:2018 (TUV, CE Approved)
Datasheet
Product Datasheet
GDT/MOV/TVS Tester
SPD Tester
LEM HOP 1000-SB O/L Split Core Hall Effect Current Sensor, 500 Amp, +/-4V Output, 40 x 104mm Aperture, +/-12..15V Supply, Panel Mount, X = 2% Open Loop AC/DC Hall Effect Sensor
Features
Bandwidth DC to 10kHz
Open loop transducer using Hall effect
Compact and versatile
Panel mounting-Horizontal or Vertical or Busbar Mounting
Insulated plastic case recognized according to UL 94-V0
Advantages
Very good linearity
Very good accuracy
Low temperature drift
Wide frequency bandwidth
Very low insertion losses
High immunity to external interference
Current overload capability
Low power consumption
Wide dynamic range, nominal 500 to 2000 A in one package.
Up to 3000 A measurement range
Applications
Power supplies for TELECOM (monitoring and measurement)
Electrical chemistry
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications.
Chopper
Battery supplied applications
Specification
LEM Part Number
HOP 1000-SB
Technology
Open Loop Hall Effect
Aperture
104 x 40mm Square
ROHS
Yes
Supply Voltage
+/-12..15 VDC Bipolar, Isolated
Load Current (RMS + DC)
1000 Amp
Measurement Range
+/-2000 Amp
Overload Rating
Contact Us for Possible Replacement
Output
+/-4 V
Isolation
3 kV
Bandwidth
DC-10 kHz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-25°C / 70°C
Accuracy
2%
Termination Style
Molex 5045-04A
Unit Weight
590g
Factory Pack Quantity
4
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
Schurter 8020.2053 AEO 10.3x38mm Fast Blow Automotive Fuse 30Amp, 1000VDC, 20kA, IEC 61730-2
Features
UL Recognized for 1000 VDC, and 275VAC
High breaking capacity of 20 kA @ 1000 VDC, 10kA @ 175VAC
Low min. interrupting rating of 1.35 x In
Meets the requirements of IEC 61730-2 for PV module safety
Applications
All photovoltaic applications
Inverters
Battery charge controllers
In-line protection
String fuses
Specification
Schurter Part Number
8020.2053
Fuse Type
I²t GpV Class Automotive Fuse
Nominal Voltage
1000VDC, 275VAC
I²t Rating (Pre-Arcing)
3150 A²/s
Nominal Current (DC)
25 Amp
Tested Breaking Capacity
20kA @1000VDC 10kA @ 275VAC
Dimensions
10.3 x 38mm
Fuse Holder
FSO Fuse Holders
Mounting Style
Requires fuse holder
Operating Temperature Range
-40°C / 125°C
Watt Loss
1.8W
DC Breaking Capacity
20kA
Unit Weight
8g
Factory Pack Qty
10
Datasheet
Product Datasheet
Compatible Fuse Holder
FSO Fuse Holders
Iskra Doo RI62J C 32-4.5kA, 2 Pole DC Miniature Circuit Breaker Disconnect Switch C Curve 32 Amp, 440VDC, 4.5kA
Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
< 50mS Trip Delay Time
1 Pole Disconnect
4.5kA Short Circuit Rating
Suitable for Isolation
Customised versions available
Type B, C, D Curve available
Standards :
IEC/EN 60898,60947-3
IP20 (IP40 Installed) IEC 61008
Specification
Iskra Doo Part Number
RI62J C32
Functions
2 Pole MCB - C Curve
Nominal Voltage
440VDC
Nominal Current Range
32 Amp RMS
Trip Delay Time
< 50ms
Rated Frequency
50/60 Hz
Operating Temperature
-25 to 55 Deg C
Rated Operations
10,000 Ops
Surge Current
500V
Short Circuit Current
4.5kA
Approvals
VDE, GOST-R
Standards
IEC/EN 60898,60947-1/2, IP20 (IP40 Installed) IEC 61008 ;
Weight
200g
Enclosure Material
UL94
Factory Pack Qty
1
Datasheet
Product Datasheet
M-FRS3-C40-1500R-T2, MODULE ONLY 1500VDC Module for Surge Protection Device for Photovoltaic Systems, Type 2 (Class II) 40kA
Specifications
Trent part number
M-FRS3-C40-1500R-T2 MODULE ONLY
Nominal Voltage Un
1500VDC
No of Poles
N/A
Category IEC / EN / VDE
Type 2 (Class II)
Location of use
String Box, Inverter, Sub Board Only
Protection modes
(+)-PE,(-)-PE,(+)-(-) PE
Additional Remote Contacts
YES NO/NC/COM
Protective element
MOV
No Fault/Fault Indication
Green Flag / Not Green Flag
Surge discharge rating
Per pole 40kA (8/20uS)9KA) Max, 20kA (8/20uS)9KA) Nominal
Internal protection and safety
Thermal disconnector in each MOV
Weight
420g
Standards
IEC614643-31:2018 (TUV, CE Approved)
Datasheet
Product Datasheet
GDT/MOV/TVS Tester
SPD Tester
Trent FRS7-B+C 37.5/440 (3+0)R, Class I,II / Type 1,2 / B,C, Surge Protection Device (SPD), 3 Pole 37.5kA (12.5kA per pole), 440VAC, DIN Rail Mount, With Remote Contacts, L/N-PE, L-PEN, L-N, N-PE High Energy MOV and GDT
Specifications
Trent part number
FRS7-B+C 37.5/440 (3+0)R
Nominal Voltage (Un) L-L
400VAC
Maximum Voltage (Uc) L-L
440VAC
No of Poles
3
Voltage Protection Level (Up)
< 2.2kV
Category IEC / EN / VDE
Class I,II / Type 1,2 / B,C
Location of use
Main Distribution Boards
Protection modes
L/N-PE, L-PEN, L-N, N-PE High Energy MOV and GDT
Additional Remote Contacts
YES
Protective element
MOV + GDT
Surge discharge rating
Imax up to 50 kA, or 12.5kA per pole
Internal protection and safety
Thermal disconnector in each MOV
Standards
IEC/EN 61643-11
Datasheet
Product Datasheet