Search results for "텔레@upcoin24``이더리움전송대행리플매입"
-
Smart ONE 100kvar 400VAC L-L, 100kVar Smart Capacitor Bank for Plug and Play Reactive Power Correction, IP21
Free Aus Post Shipping for $300 SpendFastron Electronics Smart ONE 100kvar 400VAC L-L, 100kVar Smart Capacitor Bank for Plug and Play Reactive Power Correction, IP21 For Automatic Switching of Power Factor Correction Capacitors according to changing site conditions. Features Automatic Power Factor Correction up to Cos φ = 0.95 Auto rotation of same capacitors for long life Overtemperature Alarm Optional RS485 Comms IEC 654-1, UL Approved 3 Year Fastron Electronics Warranty PR-14D.12, Automatic Reactive Power Controller 1 CT Sensing Automatic Power Factor Correction Automatic C/K Ratio Setting (0.05 -> 0.95) Cos ϕ Setting 0.85 to 0.95 CAP Backlit LCD Display Various Program Combinations IP41 Measurement System - Automatic/Manual 230VAC Aux Supply Optional Modbus RS485 Configurable Alarms Dual Password Protection Programmable Fan Control Programmable 1A/5A CT Ratio 2 x 10Kvar, 1 x 5Kvar Caps Specification Fastron Electronics Part Number Smart ONE 100kvar 400VAC Function Reactive Power Correction Steps 4 x 25kvar Dimensions W:475mm x D:215mm x L:610mm Nominal Voltage (Un) 110-440VAC Line to Line Supply Voltage 11-300VAC (L-N), 15VA 45-65Hz Relay Rating 250VAC/5Amp Switch Delay Time 1 - 999s User Adjustable Alarm 1 x Relay as above Temperature Alarm 1 x Relay as above Re-connection Delay Time 1 - 999s User Adjustable Desired Power Factor 0.80 IND - 0.80 CAP Number of Output Relays Up to 4 Steps 4 x 25kvar Smallest Capacitor Current (0.002 - 2A) x CT ratio CT Input Range 0 - 6 Amp, or 0-1.2Amp (three CT) LCD Display Accuracy Voltage +/-0.5%, Frequency +/-0.1%, Power +/-1% Energy Class 1 Phase Angle Error +/- 1% at I > 3% of range Comms RS485 (Optional) Termination Style Screw Weight 15kg Certification IEC 654-1, UL Factory Pack Qty 1 Material of housing PC/ABS Unflammable, according to UL 94 V-0, & Stainless Steel Painted RAL 1013 Enclosure protection IP21 Safety According to EN 61 010-1, installation category III Pollution degree 2 Operating Temperature -20...55 °C Datasheet Product Datasheet Controller user Manual Installation Guide MSDS for Vishay PhMKPg Series Capacitors
-
E53TP25C, Solid State Relay, 3 Phase 18-36VAC Control, 25A, 48-530VAC Load, LED Status Indicator, IP20
Free Aus Post Shipping for $300 SpendCrydom E53TP25C, Solid State Relay, 3 Phase 18-36VAC Control, 25A, 48-530VAC Load, LED Status Indicator, IP20 Features Ratings from 25A to 50 Amp @ 70-480 VAC SCR output for heavy industrial loads Zero voltage or Instantaneous turn-on outputs UL/CE/ROHS Approved IP20 Cover Available AC & DC control types Direct bond copper substrate Direct power lead frame Epoxy free design Spec Crydom Part Number E53TP25C Switching Type Zero Crossing ROHS/CE/UL Yes Control Voltage 18-36VAC Load Current 25 Amp (rms) per Phase Surge Capability 239 Amp (peak) Special Feature LED Status Indicator Mounting Style Panel Mount Load Voltage Range 48-530VAC EMC Compliant Level 3 Termination Style Screw Unit Weight 315g Factory Pack Qty 10 Datasheet Product Datasheet Equivalent Contact Us for Possible Replacement App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies
-
Thyro S 3S Series Three Phase SCR Controller 16 - 1500Amp 400VAC +10/-15%, Phase(VAR), Burst(TAKT) Fire, SWITCH Operating Modes
Advanced Energy Thyro S 3S Series Three Phase SCR Power Controller, 16-1500Amp, 400VAC, Phase(VAR), Burst(TAKT), SWITCH Operating Modes. Compatible Replacement for Eurotherm Features 400VAC +10/-57% Line to Line Voltage, Current or Power Control Smallest footprint on the market Built in Fuses 3 Phase, Phase Angle & Burst Controller with SWITCH operation mode SWITCH between Phase(VAR) or Burst(TAKT) control modes (0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control Removable Cover USB Configuration/Bias Setting Potentiometer Adjustments Synchronisation Function for Multiple TAKT Sync Applications Electrical Ovens, Kilns, or Furnaces Primary Control of Transformer Loads in Phase or Burst Fire mode Resistive Loads up to 6:1 Hot/Cold Ratio AC Soft Starter (VAR Mode Combined with PLC) Power Regulation Applications Electric Boilers Brewery Heating Industrial Light Dimming Suitable for extreme environments such as mining Series Optional Features For HRL Current Control/Feedback Programmable Relay Alarm Output Load Monitoring Analogue Output For HRLP As above with Power Control Feedback Communication Options Standard Thyro Bus Module BasicBus Module Specification Advanced Energy Part Number Thyro S 3S 400VAC or Thyro S 3S 500VAC Approvals CE, UL508A, EU Directive 2014/35/EU & 2004/108/EC Control Accuracy 3% at rated voltage Rated Operating Temperature 45°C Temperature Derating 0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C SCR Configuration Single Phase AC Switch Control Modes Phase(VAR), Burst(TAKT), QUick TAKT(QTM), Hybrid(VT on request) Control Input 4(0)-20mA, 0(1)-5V, 0(2)-10V, POT Load Current 16 to 1500 Amp @ 45 Deg C (110% @ 35 Deg C Max) Control Range 0-100% Options Conformal Coating for Gas or High Humidity Environments Mounting Style Panel Mount Supply Voltage Range 400VAC +10/-15% (-57% with 24VDC Aux Supply) Soft Start Via PLC input Termination Style Screw Unit Weight 2.1 to 74kg Factory Pack Qty 1 Technical Docs Brochure User Manual 2 Leg Control Application Blog Thyro A Series Quick Installtion Guide Setting Up Comms on Thyro A Series Controllers Anybus Device Ethernet IP Setup Guide
$2,154.91 - $10,967.22
-
SDM630MCT-MODBUS-MID-CL1 V2, DIN Rail Mount kWh Meter, 3 Phase, 240VAC aux, Class 1, 1/5 Amp CT Connect, w/ 2 x pulse outputs and RS485 Modbus RTU Comms
Free Aus Post Shipping for $300 SpendEastron Europe SDM630MCT-MODBUS-MID-CL1 V2, DIN Rail Mount kWh Meter, 3 Phase, 240VAC aux, Class 1, 0.333V CT Connect, w/ 2 x pulse outputs and RS485 Modbus RTU Comms 1/5 Amp CT Input RS 485 communication up to 38,400 bit/s as standard Optional Mbus Model available True RMS values of currents and voltages 1 x Configurable Pule Output (via Display Menu or Modbus) 1 x Fixed Pulse Output (1000imp/kwh) The meter is intended for measuring, and monitoring single-phase or electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power to the 30th Harmonic) from the measured signals. Features : Accuracy class 1 Measurement of Active and Reactive Power Modbus RTU communication up to 38,400 bit/s communication Pulse output as standard Graphic LCD with illumination Specification Eastron Europe Part Number SDM630MCT-MODBUS-MID-CL1 V2 Functions Three Phase Energy Meter Supply Voltage 230V L-N +/-15% < 5VA Nominal Measurement Range 415V L-L 230V L-N, 1/5 Amp +/-15% Maximum Measurement Range 480V L-L 230V L-N, 1/5 Amp Nominal CT Current Input 1/5 Amp Pulse Output 2 x Passive, (1 x Configurable 60/100/200ms) Tariff Input N/A Accuracy Class 1 (I,U,F,kW,kWh) Class 2 (Reactive) Mounting Din Rail Real Time Clock 1min/month (30ppm) Internal Memory N/A Dimensions 72mm x 100mm x 66mm (4 modules wide) Isolation 4kV RS485 2400-38400 b/s (400ms Response Time) Weight 150g Certification EN 61010-1 Installation Category III Factory Pack Qty 1 Safety IP51(Indoor) Enclosure Material Noryl with fire protection to UL94-V-O. Self extinguishing Enclosure Size DIN 42880 4 Modules Operating Temperature -20 →+70 °C Documents Product Datasheet User Manual Modbus Protocol Setup Video - CT Ratio Unlock Alternatives WM3-6 230DB Modbus Utility EEM Meter Setting Software Utility
-
Rish Xmer 155/80 2000/5 Split Core CT Class 0.5 20VA, 85 x 125mm Aperture
Heavy Item - No Free ShippingRishabh Xmer CT Split 155/80 2000/5 Class 0.5 20VA Series Current Transformer Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Rishabh Part Number Rish Xmer 155/80 2000/5 SCCT Class 0.5 20VA Technology Split Core AC Current Transformer Ratio 2000/5 Aperture Size 85 x 125mm Burden 45VA Accuracy Class Class 0.5 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -30°C / 85°C Continuous Current (max) 2000Amp x 1.2 Termination Style Screw Unit Weight 1000g Factory Pack Qty 9 Datasheet Product Datasheet
-
DTC1-R/M1-C5, DIN Rail Mount Temperature/Humidity Controller, Multirange Input, 24VAC/DC, Relay Output, RS485 Modbus RTU
Free Aus Post Shipping for $300 spendFastron DTC1-R/M1-C5, DIN Rail Mount Temperature/Humidity Controller, Multirange Input, 24VAC/DC, Relay Output, RS485 Modbus RTU Optional converter function 2 Input 1 Output, and 1 Input Two Output Versions available Optional 60 Segment Multi Pattern Program Control feature 4-digit display. Suit most industries including Temperature, Humidity, Pressure (0.5s response) CE Approved Each unit needs just 22.5mm width Din Rail space EC Compliant (Details) Various specials available for unique applications. Specification Fastron Part Number DTC1-R/M1-C5 Control Output Relay 3A(Resistive), 1A(Inductive load cos ??=0.4), 240VAC/30VDC Input Multirange K/J/R/S/B/E/T/Linear Voltage Current(Optional)/N/W1/W2/Pt100 Alarm Relay 3A(Resistive), 1A(Inductive load cos ??=0.4), 240VAC/30VDC Options RS485 Comms Mounting Style 22.5 x 75mm Din Rail Mount Supply Voltage 24VAC/DC Termination Style Screw Weight 230g Factory Pack Qty 1 CE Yes ?? Selection Chart PWM Control Wiring Datasheet DTC1 Brochure DTC1User Manual DTC1 User Manual Comms versions Alarm Table DTC1 (Program Control Version) User Manual
-
BCR2R1000 Temp Controller, 48x96mm, 24VAC/DC, Relay output
Free Aus Post Shipping for $300 SpendShinko BCR2R1000 Series Digital Indicating Controllers • Program control, converter function are standard features • 5-digit displays suit most industries including Temperature, Humidity, Pressure (0.5s response) • Drip-proof / Dust-proof IP66 (front panel only) • 9-step pattern (for SV and time) is a standard feature • UL/CSA Approved • Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type) • Each unit needs just 60 mm depth panel space • EC Compliant (Details) Specification Shinko Part Number BCR2R1000 Control Output SSR 12VDC +/-15%, 40mA with (short circuit protected) Input Multirange (refer to datasheet) Option 1 None Option 2 None Mounting Style 48 x 96mm Panel Mount Load Voltage Range 24VAC/DC Termination Style Screw Weight 170g Factory Pack Qty 1 ROHS Yes UL Yes CE Yes Datasheet BC Series Brochure BC Series User Manual BC Series RS485 Comms Manual Shinko Product Guide Fine Tuning Adjustments
-
N3175HE180, Thyristor(SCR) PUK 2150 Amp, 1800V, 101/35
Free Aus Post Shipping for $300 SpendWestcode-IXYS-Littlefuse N3175HE180, Thyristor(SCR) PUK 2150 Amp, 1800V, 101/35 Features Very low forward voltage drop Very low leakage current International standard package 101/35 Package Press Mounted Double or Single Sided Cooling Applications Power Supplies Rectifier for drives applications Uncontrolled Rectifiers Rectifiers for UPS Battery Chargers Field Supply for DC Motors Water Cooled Rectifiers DC Substation Blocking Diode Large Generators Specification Westcode IXYS Part Number N3175HE180 Vrrm 1800V Diode Configuration Thyristor Capsule (PUK) IF(av) @ 85 Deg C 2150 Amp Package Size ø101 x 35mm Itsm 44 kA VF(to) 0.90V Tj(max) 125°C rF 0.106mΩ Gate Terminals Faston 4.8 x 0.8mm & 2.8 x 0.8mm R th(j-c) (double sided cooled 180°sin) 0.0125°C/W R th(c-h) (double sided cooled) 0.003°C/W Weight 900g Clamping Force 30 - 65kN Factory Pack Qty 12 Certification ROHS IXYS Headquarters Germany Datasheet Product Datasheet Alternatives t2180n18tof-vt Heatsink Heatsink Profiles
-
N1718NC200, Thyristor(SCR) PUK, 1159Amp, 4200V, 74/26
Free Aus Post Shipping for $300 SpendWestcode-IXYS-Littlefuse N1718NC200, Thyristor(SCR) Capsule, 1718Amp, 2000V, 74/26 Features Very low forward voltage drop Very low leakage current International standard package 74/26 Package Press Mounted Double or Single Sided Cooling Applications Power Supplies Rectifier for drives applications Uncontrolled Rectifiers Rectifiers for UPS Battery Chargers Field Supply for DC Motors Water Cooled Rectifiers DC Substation Blocking Diode Large Generators Specification Westcode-IXYS Part Number N1718NC200 Vrrm 2000V Diode Configuration Thyristor Capsule (PUK) IF(av) @ 60 Deg C 1718 Amp Package Size ø74 x 26mm Itsm 27.2 kA VF(to) 0.979V Tj(max) 125°C rF 0.169mΩ Gate Terminals Faston R th(j-c) (double sided cooled 180°sin) 0.024°C/W R th(c-h) (double sided cooled) 0.048°C/W Weight 510g Clamping Force 19 - 26kN Factory Pack Qty 6 Certification ROHS IXYS Headquarters USA Datasheet Product Datasheet Alternatives T1190N16TOF VT SKT1200/18E Contact Us for Possible Replacement Heatsink Heatsink Profiles
-
T930N36TOF, Thyristor(SCR) PUK, 930Amp, 3600V, 74/26
Free Aus Post Shipping for $300 SpendInfineon T930N36TOF Thyristor(SCR) Capsule, 930Amp, 3600V, 74/26 Features Very low forward voltage drop Very low leakage current International standard package 74/26 Package Press Mounted Double or Single Sided Cooling Applications Power Supplies Rectifier for drives applications Uncontrolled Rectifiers Rectifiers for UPS Battery Chargers Field Supply for DC Motors Water Cooled Rectifiers DC Substation Blocking Diode Large Generators Specification Infineon Part Number T930N36TOF Vrrm 3600V Diode Configuration Thyristor Capsule (PUK) IF(av) @ 85 Deg C 930 Amp Package Size ø74 x 26mm Itsm 19.5 kA VF(to) 1.0V Tj(max) 125°C rF 0.43mΩ Gate Terminals Fastron R th(j-c) (double sided cooled 180°sin) 0.0215°C/W R th(c-h) (double sided cooled) 0.0035°C/W Weight 540g Clamping Force 20 - 45kN Factory Pack Qty 6 Certification ROHS Infineon Headquarters Germany Datasheet Product Datasheet Alternatives N1159NC400 DCR1260F42 Contact Us for Possible Replacement Heatsink Heatsink Profiles
-
MC740 S SFENC, Panel Mount Measuring Center 3 Phase, Class 0.5 50-500 L-L 50/60Hz Measurement, 240VAC Supply, Ethernet & USB Comms, w/ Supercap
Free Aus Post Shipping for $300 SpendIskra Doo MC740 S SFENC, Panel Mount Measuring Center 3 Phase, Class 0.5 50-500 L-L 50/60Hz Measurement, 240VAC Supply, Ethernet & USB Comms, w/ Supercap Smart Meter Automatic range of nominal current up to 12.5 A (Includes 5A/1A CT Input) and nominal voltage up to 750 V L-N Adjustable tariff clock, display of electric energy consumption in optional currency Optional RS 232/RS 485 communication up to 115,200 bit/s or Ethernet communication Usage The meter is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals. Features : Measurement of instantaneous values of more than 140 quantities (U, I, P, Q, S, PF, PA, f, f, MD, energy, energy price by tariffs, etc.). Accuracy class 0.5 or 0.2 (on demand) Measurement of 40 minimal and maximal values in different time periods 32 adjustable alarms Wide frequency range from 16 Hz to 400 Hz RS 232/RS 485 communication up to 115,200 bit/s or Ethernet communication MODBUS and DNP3 communication protocol MMC memory card for setting and upgrading the meter Up to 4 inputs or outputs (analogue outputs, pulse outputs, alarm outputs, tariff inputs) Universal or AC power supply Graphic LCD 128 x 64 dots with illumination Automatic range of nominal current up to 5 A and nominal voltage up to 750 V Adjustable tariff clock, display of electric energy consumption in optional currency Multilingual support User-friendly PC MiQen software 128 samples in one period Measurement of THD on Current or Voltage from 0 to 400% Specification Iskra Doo Part Number MC740 S SFENC Functions Power Quality Meter, Energy Meter, Power Transducer, Network Analyser Supply Voltage 240VAC < 5VA 40-70Hz Nominal Measurement Range 50-500V L-N, 5 Amp 50/60Hz Maximum Measurement Range 800V L-N, 12.5 Amp Alarm N/A (Optional 4 Relays, 32 Alarms, 4 Groups) Analogue Output N/A (Optional 4 x 20mA) Digital Input N/A (Optional 4 x 230VAC/DC,75..130VAC/DC..5..48VAC/DC) Pulse Output N/A (Optional) Pulse Input N/A (Optional) Bistable Switch/Latching Relay Alarm N/A (Optional) Status (Watchdog) Output N/A (Optional) Tariff Input N/A (Optional 4 x 230VAC/DC,75..130VAC/DC..5..48VAC/DC) Accuracy Class 0.5 (I,U,F,PF,θ,THD) (Class 0.2 Optional) Class 1(Active), Class 2 (Reactive) Battery Backup Supercap Real Time Clock 1min/month (30ppm) Internal Memory 8MB MMC up to 2GB Isolation 3.7kV Ethernet RJ45 10/100Mbit/s USB Yes (2400-115200 b/s) RS232/RS485 N/A (optional 2400-115200 b/s) Weight 600g Certification UL, CSA, ROHS Factory Pack Qty 1 EU Directives Degree on electrical equipment designed for use within certain voltage limits URLRS 53/00 (Directive 73/23/EEC on low voltage): SIST EN 61010-1:2002 Safety Requirement for electrical equipment for measurement, control and laboratory use, part1 : general requirement Decree on electromagnetic Compatibility (EMC) URLRS 61/00 (Directive 89/336/EEC on electromagnetic compatibility): SIST EN 61036 item 4.5: 1998 Meters for active energy (class 1 and 2) Safety Protection Class II 600V rms, installation category II 300V rms, installation category III Pollution Degree 2 in compliance with SIST EN 61010-1:2002 Enclosure Material PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP52 (IP00 for terminals) in compliance with SIST EN 60529:1997 Resistance to HF Interference Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12 Conducted and radiated emissions Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure) Operating Temperature -20 →+70 °C except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-22 Datasheet Product Datasheet User Manual
-
WM3-6 230PB, kWh Sub Meter, 230/400VAC +20/-15%, Three or Single Phase, 65 Amp Direct Connect, Bidirectional Counter, Pulse Output & IR Comms, DIN Rail Mount
Free Aus Post Shipping for $300 SpendIskra Doo WM3-6 230PB Three Phase Power Meter with Pulse Output & IR Comms 65 Amp direct connect, no CT's required Ultra slim 3 DIN IR Communication as standard Pulse Output Optional RS485 communication up to 19,200 bit/s True RMS values of currents and voltages Measurements of active, reactive power Accuracy class 1 The meter is intended for measuring, and monitoring single-phase electrical power networks. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals. Features : Measurement of Active and Reactive Power Optional Pulse Output RS485 Comms IR Comms Graphic LCD with illumination Multilingual support User-friendly PC MiQen software Specification Iskra Doo Part Number WM3-6 230PB Functions Energy Meter Supply Voltage 230V L-N, 400V L-L 5 Amp -20% +15% < 5VA Nominal Measurement Range 230V L-N, 5 Amp -20% +15% Maximum Measurement Range 230V L-N, 5 Amp -20% +15% Nominal Current Input 3 x 65 Amp AC Direct Connect Infra Red Output 19200 bit/s Tariff Input N/A (Optional) Accuracy Class 1 (I,U,F,PF,) Class 2 (Reactive) Mounting Din Rail Real Time Clock 1min/month (30ppm) Dimensions 53.6 x 84 x 69.4mm (3 DIN) Pulse Output Yes Isolation 4kV RS485 (Optional) 1200-19200 b/s Weight 270g Certification UL, CSA, ROHS Factory Pack Qty 1 Safety Protection Class II 600V rms, installation category II 300V rms, installation category III Pollution Degree 2 in compliance with SIST EN 61010-1:2002 Enclosure Material PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP52 (IP00 for terminals) in compliance with SIST EN 60529:1997 Operating Temperature -20 →+70 °C Datasheet Product Datasheet User Manual