Fastron Electronics HF121-12/0.4-50-7%K, 50kVar 400VAC(0.76mH) 7% Detuned Reactor for Power Factor Correction Capacitor Banks, 0.76mH(400VAC) 1.229mH(525VAC)
Specification
Technical Features
HF121-12/0.4-50-7%K
Electrical
Voltage
400V/525V
Network Frequency
50/60Hz
Inductance (mH) @ 400VAC
0.76mH
Inductance (mH) @ 525VAC
1.229mH
Nominal Power
50kvar
Value of p%
7% (189Hz)
Type of Conductor
Aluminium/Copper(optional)
Tolerance L
5%
Linearity (5% L)
1.8 x In
Isolation Voltage
kV
Maximum Room Temperature
-10 to 45 Deg C
Internal isolation
Class F(155°C), Class H (180°C Optional)
Maximum Overload
Permanent
1.17 x In
Temporary
2 x In
Safety
Protection Thermostat
Opens at 90 °C
Degree Protection
IP00
Installation
Indoor
Standards
EN-60289, IEC60076
Weight
38kg
Datasheet
Product Datasheet
Installation Guide
HF121 Series Installation Guide
LEM DVL 1500/SP5, Digital Voltage Transducer, Vpn = 1000V, 50mA output, +/-15...24VDC powered, 8.5kV Isolation, All Terminals From the Side, No Top Terminals
Features
Bandwidth DC to 14kHz
Digital Transducer (ASIC based)
Closed loop transducer using Hall effect
Compact and versatile
Panel Mount
Insulated plastic case recognized according to UL 94-V0
All Terminals From the Side, No Top Terminals
Advantages
Very good linearity
High accuracy
Low temperature drift
Wide frequency bandwidth
Very low insertion losses
High immunity to external interference
Voltage overload capability
Low power consumption
Applications
Railway substation or locomotive
AC variable speed drives and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Water Treatment Electronics
Specification
LEM Part Number
DVL 1500/SP5
Technology
Closed Loop Hall Effect
Aperture
No Aperture
ROHS
Yes
Supply Voltage
+/-15..24 VDC Bipolar, Isolated
Primary Nominal Voltage (RMS + DC)
+/- 1000V
Measurement Range
+/- 1500V
Output
50 mA @Vpn
Isolation
8.5 kV
Bandwidth
DC-14 kHz
Mounting Style
Panel Mount
Operating Temperature Range
-40°C / 70°C
Accuracy
1%
Termination Style
Threaded inserts output, Short input studs
Unit Weight
270g
Factory Pack Quantity
4
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
BR6-FNSP4, Temp Controller, 48x24mm, 100-240VAC, TH-540N or NTC Input, 12VDC SSR
4-digit displays suit most industries including Temperature, Humidity, Pressure (0.5s response)
Drip-proof / Dust-proof IP66 (front panel only)
CE Approved
Each unit needs just 60 mm depth panel space
EC Compliant
Specification
Hanyoung Nux Part Number
BR6-FNMP4
Control Output 1 (Heat)
10-15VDC 30mA
Control Output 2 (Cool)
N/A
Input
TH-540N or NTC Input
Alarm
N/A
Option 1
N/A
Mounting Style
48 x 24mm Panel Mount
Supply Voltage
85 - 265VAC
Termination Style
Screw
Weight
200g
Factory Pack Qty
1
ROHS
Yes
UL
Yes
CE
Yes
Datasheet
BR6 Series Instruction Manual
Free Software
Hanyoung Nux TCS Software
Hanyoung Nux TCS Software User Manual
VX Series SB Driver (Windows 7) Not required for Windows 10 or 11
Crydom D5D10, Solid State Relay, DC 3-32VDC control, 10A, 500VDC Load
Features
Ratings from 7A to 100 Amp @ 100-500VDC
Mosfet output for reliable DC switching
Multiple modules can be wired in parallel for higher currents
UL/CSA/VDE Approved, CE Compliant to EN60950-1
Improved SEMS screw and washer
Redesigned housing with anti-rotation barriers
Direct bond copper substrate
EMC compliant to Level 3
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
D5D10
Switching Type
DC Load
ROHS
Yes (Details)
Control Voltage
3.5-32VDC
Load Current
10 Amp DC
Surge Capability (10ms)
29 Amp DC
Special Feature
None
Mounting Style
Panel Mount
Load Voltage Range
0 - 500VDC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
75g
Factory Pack Qty
20
Datasheet
Product Datasheet
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
Equivalent
Contact Us for Possible Replacement
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Fastron FC5-S-W-1-G-4, 24VDC PID Controller with 1 Alarm, K,E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, Relay + 12VDC Output
4-digit displays (0.5s response)
Drip-proof / Dust-proof IP66 (front panel only)
Input signals can be converted to insulated -0-10V, Relay, 12VDC (SSR) and 4 to 20 mA DC outputs available
Each unit needs just 75 mm depth panel space
Specification
Fastron Part Number
FC5-S-W-1-G-4
Control Output
Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)/SSR 12VDC @20mA
Input
Multirange Type K,E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input
Option 1
1 Alarm standard
Mounting Style
48 x 48 Panel Mount
Supply Voltage
24VDC +/-15%
Termination Style
Screw
Sampling Time
100ms
Weight
150-270g
Factory Pack Qty
10
Datasheet
Datasheet
User Manual
Modbus Protocol
FC5 Communication Protocol
Iskra Doo PFCmax 6 Power Factor Control Relay
Single CT Sensing
Isolated Switching of Power Factor Correction Contactors
Cos ϕ Setting 0.85 to 0.95 CAP
Auto CT Secondary Selection
IP41
Up to 6 steps
Measurement System - Automatic/Manual
240VAC Aux Supply
Specification
Iskra Doo Part Number
PFCmax 6
Function
Reactive Power Correction
Nominal Voltage (Un)
90-550VAC Line to Line
Supply Voltage
240VAC (L-N), 15VA 45-65Hz
Relay Rating
250VAC/10Amp
Switch Delay Time
4s - 999s
Alarm
Over/Under Compensation, Low Current, Overcurrent, Overvoltage
Temperature Alarm
N/A
Re-connection Delay Time
4s - 999s
Desired Power Factor
0.85 IND - 0.85 CAP
Number of Output Relays
7
Smallest Capacitor Current
10mA
CT Input Range
0 - 6 Amp
LCD Display Accuracy
Voltage +/-0.5%, Frequency +/-0.1%, Power +/-1% Energy Class 1
Phase Angle Error
+/- 1% at I > 3% of range
Comms
N/A
Termination Style
Screw
Weight
700g
Certification
IEC 654-1
Factory Pack Qty
1
Material of housing
PC/ABS Unflammable, according to UL 94 V-0
Enclosure protection
IP41 for case, IP20 for terminals
Safety
According to EN 61 010-1, installation category III Pollution degree 2
Operating Temperature
-20...60 °C
Datasheet
Product Datasheet
User Manual
Fastron Electronics AM5A-A-DV1-A Digital Panel Meter & Transmitter
Adjustable Zero and Span Setting
Adjustable Display Scaling
Large 5 Digit 20.3mm (8 Inch) LED Display
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 96 x 48mm Panel Space
90mm Depth
Specification
Fastron Electronics Part Number
AM5P-C4225A-NAN
Signal Conditioned Output
4-20mA
Input
0 - 50mVDC
Over Range
x 1.5
Operating Temperature
0 - 60°C
Supply Voltage
110- 240VAC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
96 x 48mm Panel Mount
Case Material
PC - UL 94 V0
Weight
320g
Factory Pack Qty
1
Datasheet
Product Datasheet
User Manual
Application Notes
Panel Meters Blog Articles
Fastron Electronics SCT-F36-400-0.4V, 400mV, 400Amp measurement Split Core CT's for Power Quality Analysers 1mV/A
Features
Quick Release Split Core System
Cable Mount
400mV Output
Self Powered
Rated System Voltage 0.60/3kV
0.9M Flying Leads
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
SCT-F36-400-0.4V
Technology
Split Core AC Current Transformer
Ratio
400/400mV
Aperture Size
ø 35 mm
VA Rating
N/A
Accuracy Class
Class 1
Output
400mV (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
400Amp x 1.2
Termination Style
0.9M Flying leads
Unit Weight
400g
Factory Pack Qty
9
Datasheet
Product Datasheet
Stocked Split Core CT's Listing
Application Notes
Installation Guide
Types of Current Transformers - Blog
Cable Losses and CT's
High Accuracy or High Burden Requirements for CT's
Iskra Doo MVR 54N 400VAC Series Voltage Monitoring Relay
MVR 54N Series serves to monitor voltage, phase failure and sequence in switchboards, protection of devices in 3-phase 4 wire mains
Features
Upper and lower level of monitoring voltage
Adjustable time delay eliminates short voltage peaks and failures in the main
Supply is done from monitored voltage
Faulty state is indicated by red LED and by opening of output relay contact
Output contact 1 x Changeover / SPDT 8 A /250 V AC1
In case supply voltage falls below 60 %Un (U lower level) relay off immediately opens without delay
MVR 54 - supply from all phases which means that relay is functional also in case when one phase is faulty
Variant MVR 54N - supply L1-N, means that relay monitors also failure of neutral wire
1-MODULE, DIN rail mounting
Specification
Technical Data
MVR 54
MVR 54N
Supply and measuring
L1, L2, L3
L1, L2, L3, N
Supply terminals
L1, L2, L3
L1, N
Supply/measured voltage
3 x 400 V / 50 Hz
3 x 400 V / 230 V /50 Hz
Level Umax
105 - 125 % Un
Level Umin
75 - 95 % Un
Burden
max. 2 VA
Hysteresis
2 %
Max. permanent overload
AC 3 x 460 V
AC 3 x 265 V
Peak overload <1ms
AC 3 x 500 V
AC 3 x 288 V
Time delay T1
max. 500 ms
Time delay T2
adjustable 0.1-10 s
Output
Number of contacts
1x changeover/ SPDT (AgNi / Silver Alloy)
Rating
8 A / AC1
Breaking capacity
2500 VA / AC1, 240 W / DC
Inrush current
10 A
Switching voltage
250 V AC1 / 24 V DC
Min. breaking capacity DC
500 mW
Indication of state
red LED
Mechanical life
1 x 107
Electrical life (AC1)
1 x 105
Other information
Operating temperature
-20 ... +55 °C
Storage temperature
-30 ... +70 °C
Electrical strength
4 kV (supply - output)
Operating position
any
Mounting
DIN rail EN 60715
Protection degree
IP 40 from front panel / IP 10 terminals
Overvoltage cathegory
III.
Pollution degree
2
Max. cable size (mm )2
solid wire max. 2x2.5 or 1x4 ; with sleeve max. 1x2.5 or 2x1.5
Dimensions
90 x 17,6 x 64 mm
Weight
69 g
67 g
Standards
EN 60255-6, EN 61010-1
Datasheet
Product Datasheet
Application Notes
Relay in 3-phase main monitors size of phase voltage. It is possible to set two independent voltage levels and thus it is possible to set two independent voltage levels and monitor e.g. undervoltage and overvoltage independently. In normal state when voltage is within set levels, output relay is closed and red LED shines.
In case voltage exceeds or falls below the set levels, output relay opens and red LED shines ( LED indicates faulty state – flashes when timing). In case supply voltage falls below 60 % Un (UOFF lower level)relay immediately opens without delay and faulty state is indicated by red LED.In case timing is in progress and faulty state is indicated, timing is immediately stopped.
Rishabh Rish Xmer 140-100H (45) 2500/5 Class 1 Series Current Transformer
Features
Built In Sealable Terminal Covers
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Rishabh Part Number
Rish Xmer 140-100H (45) 2500/5 Class 1
Technology
AC Current Transformer
Ratio
2500/5
Aperture Size
⌀ 86mm or 101 x 31mm Busbar
VA Rating
45VA
Accuracy Class
Class 1
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-30°C / 85°C
Continuous Current (max)
2500Amp x 1.2
Termination Style
Screw
Unit Weight
1.2kg
Factory Pack Qty
9
Datasheet
Product Datasheet
FPT-135 5000/5A 5P35 5VA Protection Class CT, 5000/5A, Class 5P35 5VA, 135 x 81mm Aperture
Features
Built In Sealable Terminal Covers
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
VDE0414-44-1, GB1208-2006, EN 60044-1 and IEC 61869-2
Applications
Protection Relays
Safety Equipment
Fault Monitoring
??
Specification
Fastron Electronics Part Number
FPT-135 5000/5A 5P35 5VA
Technology
Protection Class Current Transformer
Ratio
5000/5
Aperture Size
81 x 135mm
VA Rating
5VA
Accuracy Class
Class 5P35
Output
5 Amp AC (?%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-10??C / 50??C
Continuous Current (max)
5000Amp x 1.3
Termination Style
Screw
Stanbards
VDE0414-44-1, GB1208-2006, EN 60044-1 and IEC 61869-2
Unit Weight
7kg
Factory Pack Qty
1
??
Datasheet