Infineon DD600N12K, Dual Diode Module, 600 Amp, 1200V, 60mm Base
Features
Pressure Contact Technology
Electrically insulated base plate
Very low forward voltage drop
Very low leakage current
Planar passivated chips
International standard package
3600V Isolation
60mm Base Width
Applications
Power Supplies
Rectifier for drives applications
Uncontrolled Rectifiers
Rectifiers for UPS
Battery Chargers
Filed Supply for DC Motors
DC supply for PWM inverter
Specification
Infineon Part Number
DD600N12K
Vrrm
1200V
Diode Configuration
Dual Diode Module
IF(av) @ 100 Deg C
600 Amp
Package Size
W:60mm L:101mm D:52mm
Itsm
22 kA
VF(to)
0.75V
Tj(max)
150°C
rF
0.215mΩ
Terminals
M10 Bolt
Hole Centres
80mm x 38mm (M6)
Gate Terminals
N/A
R th(j-c)
0.078°C/W
R th(c-h)
0.02°C/W
Weight
900g
Mounting Torque
5 Nm (12 Nm Terminals)
Factory Pack Qty
2
Certification
UL Listed, ROHS
IXYS Headquarters
United States
Datasheet
Product Datasheet
Alternatives
MDC600-416F3
Fastron Electronics GT-2A6-A-1, Signal Isolator/Conditioner, 4-20mA Loop Supply Sensor Input, 4-20mA Output, 100-240VAC/DC
Adjustable Zero and Span Setting
250mS Response Time
PC 94 UL V0
Input signals can be converted from 4 to 20 mA DC Loop Supply (Sensor Input) to insulated 4-20mA Standard Process Output
Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space
Specification
Fastron Electronics Part Number
GTD-2A6-A-1
Control Output
4-20mA Standard
Input
4-20mA Sensor Input (Loop Powered)
Over Range
x 1.5
Operating Temperature
0 - 60°C
Supply Voltage
100-240VAC/DC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
DIN Rail Mount
Case Material
PC - UL 94 V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
Gigavac GV121CAX, Contactor SPST-NO, 200+ AMP, 12-100VDC, 24VDC Coil, 38cm Flying leads, IP67, SIDE MOUNTING
Features
Hermetically Sealed
UL1604 for Class I & II Div 2 and Class III for use in hazardous locations
IP67 - Temporary water immersion (30 Min)
SAE J1171 External ignition protection
ISO8846 Protection against ignition around flammable gasses
CE Approved
High Efficiency Dual DC Coils - Very low 12,24,48VDC continuous coil power with no EMI emissions or cross-talk on your system control power
Ideal for battery powered systems or where low power is needed
PWM option provides additional drive control flexibility
Built in Coils suppression for all DC Coils
Flexible package for installation
Specification
Gigavac Part Number
GV121CAX
Main Contact Type
SPST-NO
Auxiliary Contact Type
None
Coil Voltage
24VDC
Load Current
200+ Amp
Mechanical Life @ 0 Amp
1,000,000 Operations
Dielectric at Sea Level (leakage <1mA)
2.5kV rms
Control Input Terminals
38cm Flying Leads
Special Feature
None
Mounting Style
Panel Mount (M5)
Load Voltage Range
12 - 100VDC
Standards
CE, UL1604, IP67, SAEJ1171
Termination Style
M8
Unit Weight
450g
Factory Pack Qty
1
Datasheet
Product Datasheet
Crydom 84140900, Dual Solid State Relay, Two Pole 4-15VDC Control, 2 x 40A, 24-280VAC Load
Features
Ratings from 2 x 25A to 2 x 40 Amp @ 24-530 VAC
SCR output for heavy industrial loads
Zero voltage or instantaneous turn-on outputs
UL/CSA/VDE Approved, CE Compliant to EN60950-1
Improved SEMS screw and washer
Redesigned housing with anti-rotation barriers
AC & DC control types
Direct bond copper substrate
EMC compliant to Level 3
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
84140900
Switching Type
Zero Crossing (Dual)
ROHS
Yes (Details)
Control Voltage
4-15VDC
Load Current
2 x 40 Amp (rms)
Surge Capability
597 Amp (peak)
Special Feature
Dual SSR
Mounting Style
Panel Mount
Load Voltage Range
24-280VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
75g
Factory Pack Qty
20
Datasheet
Product Datasheet
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Fastron Electronics SCT-F36-400-133mA, 400Amp measurement Split Core CT's
Features
Quick Release Split Core System
Cable Mount
133mA Amp Output
Self Powered
Rated System Voltage 0.60/3kV
0.9M Flying Leads
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
SCT-F36-400-133mA
Technology
Split Core AC Current Transformer
Ratio
400/133mA
Aperture Size
ø 35 mm
VA Rating
N/A
Accuracy Class
Class 1
Output
133mA Amp (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
400Amp x 1.2
Termination Style
0.9M Flying leads
Unit Weight
400g
Factory Pack Qty
9
Datasheet
Product Datasheet
Stocked Split Core CT's Listing
Application Notes
Installation Guide
Types of Current Transformers - Blog
Cable Losses and CT's
High Accuracy or High Burden Requirements for CT's
C100N+100R-Lugged, RC Snubber Network 275VAC, Class X2, 100uF 100 Ohm Lugged for SSR or SCR Terminal Mounting
These snubber neworks are suitable for transient supression in small contactors, bridge rectifers, or solid state relays switching AC or DC Loads. Easily connected or lugged to solid stage relay or power module terminals. See EMC filters, and Metal Oxide Varistors sections for additional supression components.
As and added bonus, these Snubber Networks Improve the Power Factor of switched loads.
Datasheet
Product Datasheet
Crydom HDC100D120, 3.5-32VDC Input, 7-100V, 120Amp DC Output Solid State Relay
Features
Ratings from 100A to 160 Amp @ 7-150VDC
Mosfet output for reliable DC switching
Multiple modules can be wired in parallel for higher currents
UL/CSA/VDE Approved, CE Compliant to EN60950-1
Improved SEMS screw and washer
Redesigned housing with anti-rotation barriers
Direct bond copper substrate
EMC compliant to Level 3
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
HDC100D120
Switching Type
DC Load
ROHS
Yes (Details)
Control Voltage
3.5-32VDC
Load Current
120 Amp DC
Surge Capability (10ms)
360 Amp DC
Special Feature
High Current Stud Terminals
Mounting Style
Panel Mount
Load Voltage Range
7 - 100VDC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
345g
Factory Pack Qty
20
Datasheet
Product Datasheet
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Fastron Electronics FESCT-51-1000-0.333V, 1000Amp measurement Split Core CT's, w/1M Flying leads, 51x51mm Aperture, Class 1
Features
Quick Release Split Core System
1m Flying Leads
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.60/3kV
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Electronics Part Number
FESCT-51-1000-0.333V
Technology
Split Core AC Current Transformer
Ratio
1000/0.333V
Aperture Size
51 x 51mm
VA Rating
N/A
Accuracy Class
Class 1
Output
0.333VAC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 55°C
Continuous Current (max)
1000Amp x 1.2
Termination Style
1M Twisted Pair 0.34mm^2
Unit Weight
950g
Factory Pack Qty
9
Datasheet
Product Datasheet
Application Notes
Installation Guide
Crydom HDC100D160, 3.5-32VDC Input, 7-100V, 160Amp DC Output Solid State Relay
Features
Ratings from 100A to 160 Amp @ 7-150VDC
Mosfet output for reliable DC switching
Multiple modules can be wired in parallel for higher currents
UL/CSA/VDE Approved, CE Compliant to EN60950-1
Improved SEMS screw and washer
Redesigned housing with anti-rotation barriers
Direct bond copper substrate
EMC compliant to Level 3
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
HDC100D160
Switching Type
DC Load
ROHS
Yes (Details)
Control Voltage
3.5-32VDC
Load Current
160 Amp DC
Surge Capability (10ms)
470 Amp DC
Special Feature
High Current Stud Terminals
Mounting Style
Panel Mount
Load Voltage Range
7 - 100VDC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
345g
Factory Pack Qty
20
Datasheet
Product Datasheet
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies