LEM PCM 10-P Series Closed Loop DC Hall Effect Sensor for Point System Monitoring, Bipolar 4-20mA Output
Features
Closed loop sensor using Hall Effect
Panel mounting
Split core design for easy installation
Insulated plastic case to UL 94-V0 Water resistant design rated to IP 67
Reverse polarity protected
Advantages
Very good linearity
Excellent accuracy
Current overload capability
No insertion losses.
Non - contact measurement (does not need a safety case)
Applications
Railway equipment
Points condition monitoring
Signal light indication
Battery supplied applications Uninterruptable Power Supplies (UPS).
Specification
LEM Part Number
PCM 10-P
Technology
Closed Loop Hall Effect
ROHS
Yes
Supply Voltage
24V
Aperture
ø15.6mm
Load Current (RMS + DC)
10 Amp
Measuring Range
+/- 20 Amp
Overload Capacity (Ampere Turns)
30000 Amp
Output
4-20mA
Standards
EN 50121-59EMC),EN 50155(temperature and humidity),EN61010-1/2 (safety)
Bandwidth
DC-1000Hz
Mounting Style
Panel Mount
Operating Temperature Range
-40°C / 70°C (50°C Continuous)
Accuracy
0.5%
Termination Style
Switchcraft EN3L4M connector
Unit Weight
120g
Factory Pack Qty
4
Datasheet
Product Datasheet
Application Notes
FAQ
Fastron Electronics FAT100D420T, AC Current Transducer, 150Amp Measurement, 36mm Split Core, 4-20mA Average RMS Output, Accuracy = 1%, Terminal Version
Features
Quick Release 36mm Split Core System
Cale Mount
4-20mA Output
24VDC Aux
Rated System Voltage 0.60/2.5kV
0.5M Flying Leads
Applications
Control Systems
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
FAT150D420T
Technology
36mm Split Core AC Current Transformer
Ratio
150/4-20mA
Aperture Size
ø 24 mm
VA Rating
N/A
Accuracy Class
Class 1
Output
4-20mA (+20%)
Isolation
2.5kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
150Amp x 1.2
Termination Style
Screw Terminals
Unit Weight
250g
Factory Pack Qty
9
Datasheet
Product Datasheet
Application Notes
Installation Guide
F115-4-90D, Panel Mount Single Phase Solid State Contactor, 70-480VAC, 90 Amp Switching, 90-280VAC or 4-32VDC Control Contactor Style Modules
Ratings from 50A to 350 Amp @ 70-533 VAC
Thermal Overload Detection (via Bimetal Thermal Switch)
SCR output for heavy industrial loads
Zero voltage or instantaneous turn-on outputs
UL/CE/ROHS Compliant
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Optional Fuses(Loose), Varistors(mounted) or 240VAC Snubber(mounted)
Specification
Part Number
F115-4-90D
Switching Type
Zero Crossing
ROHS/CE/UL
Yes
Control Voltage
3-32VDC
Load Current
90 Amp (rms) @ 50 Deg C
Special Feature
N/A
Mounting Style
Panel Mount
Load Voltage Range
70-480VAC
Max Non Repetitive Peak Voltage
600 Vp
Termination Style
Screw Terminals
Factory Pack Qty
1
Dimensions and Fuse Kits
Part Number
Approximate Dimensions
Panel Mount Fuse Kit
DIN Rail Mount Fuse Kit
DR2260D35U
L:90 x W:22.5 x D:116mm
30-40 Amp 660VAC Fuse Kit
Trent 40 Amp Cartridge Fuse
F115-4-50A(D)
L:110 x W:125 x D:185mm (Figure 2)
50-75 Amp 660VAC Fuse Kit
Trent 63 Amp Cartridge Fuse
F115-4-90A(D)
L:155 x W:125 x D:185mm (Figure 2)
80-125 Amp 660VAC Fuse Kit
Trent 125 Amp Cartridge Fuse
F115-4-120A(D)
L:210x W:125 x D:195mm (Figure 3)
80-125 Amp 660VAC Fuse Kit
N/A
F115-4-220A(D)
L:155 x W:125 x D:195mm (Figure 4)
160-200 Amp 660VAC Fuse Kit
N/A
F115-4-250A(D)
L:255 x W:125 x D:195mm (Figure 4A)
200-250 Amp 660VAC Fuse Kit
N/A
Datasheet
F115_135 Series Datasheet
Rishabh Rish Con- CA-AVG-05-F-1-02-H, AC Current Transducer, 50Hz, 5A Full Scale, 4-20mA Output, 60-300VAC/DC Supply, without display
Average RMS 4-20mA output
Dual output version available
300mS response time
PC 94 UL V0
Each unit needs just 22.5 x 100.9 mm depth DIN Rail cabinet space
Specification
Rishabh Part Number
Rish Con-CA-AVG-05-F-1-02-H
Measurement Output
4-20mA (Average RMS)
Input
1 - 5 Amp 50/60Hz
Overlaod (Continuous)
120%
Overload (1 second)
150%
Operating Temperature
-40 - 70°C
Supply Voltage
60 - 300VAC
Accuracy
0.2%
Response Time
250mS
Termination Style
Screw
Mounting Style
DIN Rail Mount
Safety
IP40/IP20 EN60529 Protection Class II EN61010
Weight
400g
Factory Pack Qty
1
Datasheet
Product Datasheet
HS151DR-D2475, Din Rail Mount Solid State Relay with Heatsink, 4-32VDC Control Input, 24-280VAC Output, 42 Amps @ 40 Deg C ambient
4-20mA Proportional Phase Control Input
Ratings from 25A to 100 Amp @ 70-280 VAC
SCR output for heavy industrial loads
Instantaneous turn-on outputs
UL/CE/ROHS Compliant
Includes Plastic IP20 Terminal Cover
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Specification
Crydom Part Number
HS151DR + D2475
Switching Type
Zero Crossing
ROHS/CE/UL
Yes
Control Voltage
4 - 32VDC
Load Current @ 40 Deg C
42 Amp
Surge Capability
910 Amp (peak)
Special Feature
N/A
Mounting Style
Din Rail Mount
Load Voltage Range
24-280VAC
Max Non Repetitive Peak Voltage
850 Vp
Termination Style
Screw
Dimensions
L:105mm x W:67.5mm x D:132mm
Unit Weight
1050g
Factory Pack Qty
20
Datasheets
HS151DR Datasheet
Series 1
Product Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
Current Transducer, AT-AA9-A-1, AC Current Transducer, Average RMS, 10 Amps, 100-240VAC/DC Aux, 4-20mA output output
Adjustable Zero and Span Setting
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type) or 0-10V/0-5V (For Direct Voltage Type)
Each unit needs just 50mm x 120mm depth DIN Rail cabinet space
Specification
Fastron Electronics Part Number
AT-AA9-A-1
Control Output
4-20mA Average RMS
Input
0-10 Amp Rms
Over Range
x 1.2
Operating Temperature
0 - 60°C
Load Voltage
100-240VAC/DC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
DIN Rail Mount
Case Material
PC - UL 94 V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
RCS-1200-0400, 0.333V 3 Phase 400Amp AC Measurement 4 Inch Rogowski Coils with Integrator, Class 1:
The RCS-1200 three-phase flexible rope CT from Magnelab converts AC input current of up to 5000 amperes to an AC output of 0.333 volt.
A 9 to 36 VDC power supply is required to operate these coils. The RCS-1200 comes with an integrator which includes flexible strain relief cables.
Included is an 12 inch circumference rope CT with Integrator, and 8 feet of twisted pair (600V) output leads.
Magnelab Coils come with 10 year warranty
Specification
Magnelab Part Number
RCS-1200-0400
Function
AC Current Measurement
Nominal Measurement Current (Ipn)
400 Amp RMS
Measurement Range
10% - 130% if Ipn
Frequency Measuring Range
50-1500Hz (15th Harmonic)
Operating Voltage
9 - 36VDC
Accuracy
1% from 25 to 500 Amp
Phase Angle
< 0.5 Degrees
Coil Diameter (⌀)
4 Inch
Coil Circumference
12 Inch
Integrator to Coil Cable
8 Feet Shielded
Maximum Voltage
600V (on bare conductor)
Operating Temperature
-15°C to 65°C
Storage Temperature
-45°C to 80°C
Power Consumption
< 2VA
Overload
20,000 Amp (continuous)
Termination Style
Screw
Weight
1200g
Certification
CE
Factory Pack Qty
1
Certifications
UL Recognized E96927 to IEEE C57.13, CAN/CSA 60044-1
Meets UL STD 61010-1, CAN/CSA C22.2 No. 61010
CE
ROHS
Datasheet
Product Datasheet
Application Notes
RCS/RCT Series Installation Guide
F115-4-220A, Panel Mount Single Phase Solid State Contactor, 70-480VAC, 220 Amp Switching, 90-280VAC or Control Contactor Style Modules
Ratings from 50A to 350 Amp @ 70-533 VAC
Thermal Overload Detection (via Bimetal Thermal Switch)
SCR output for heavy industrial loads
Zero voltage or instantaneous turn-on outputs
UL/CE/ROHS Compliant
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Optional Fuses(Loose), Varistors(mounted) or 240VAC Snubber(mounted)
Specification
Part Number
F115-4-220A
Switching Type
Zero Crossing
ROHS/CE/UL
Yes
Control Voltage
90-280VAC
Load Current
220 Amp (rms) @ 50 Deg C
Special Feature
N/A
Mounting Style
Panel Mount
Load Voltage Range
70-480VAC
Max Non Repetitive Peak Voltage
600 Vp
Termination Style
Screw Terminals
Factory Pack Qty
1
Dimensions and Fuse Kits
Part Number
Approximate Dimensions
Panel Mount Fuse Kit
DIN Rail Mount Fuse Kit
DR2260D35U
L:90 x W:22.5 x D:116mm
30-40 Amp 660VAC Fuse Kit
Trent 40 Amp Cartridge Fuse
F115-4-50A(D)
L:110 x W:125 x D:185mm (Figure 2)
50-75 Amp 660VAC Fuse Kit
Trent 63 Amp Cartridge Fuse
F115-4-90A(D)
L:155 x W:125 x D:185mm (Figure 2)
80-125 Amp 660VAC Fuse Kit
Trent 125 Amp Cartridge Fuse
F115-4-120A(D)
L:210x W:125 x D:195mm (Figure 3)
80-125 Amp 660VAC Fuse Kit
N/A
F115-4-220A(D)
L:155 x W:125 x D:195mm (Figure 4)
160-200 Amp 660VAC Fuse Kit
N/A
F115-4-250A(D)
L:255 x W:125 x D:195mm (Figure 4A)
200-250 Amp 660VAC Fuse Kit
N/A
Datasheet
F115_135 Series Datasheet
LEM HTRS 30-SBI, Railway Split Core DC Current Sensor, 30 Amp, 4-20mA Output
Features
Closed loop sensor using Hall Effect
Din Rail or Panel Mounting
Split core design for easy installation
Insulated plastic case to UL 94-V0 Water resistant design rated to IP 67
Reverse polarity protected
Advantages
Very good linearity
Excellent accuracy
Current overload capability
No insertion losses.
Non - contact measurement (does not need a safety case)
Applications
Railway equipment
Points condition monitoring
Signal light indication
Battery supplied applications Uninterruptable Power Supplies (UPS).
Specification
LEM Part Number
HTRS 30-SBI
Technology
Closed Loop Hall Effect
ROHS
Yes
Supply Voltage
24V
Aperture
ø10mm
Load Current (RMS + DC)
30 Amp
Measuring Range
+/- 60 Amp
Overload Capacity (Ampere Turns)
30000 Amp
Output
4-20mA
Standards
EN 50121-59EMC),EN 50155(temperature and humidity),EN61010-1/2 (safety)
Bandwidth
DC-30kHz
Mounting Style
Panel Mount
Operating Temperature Range
-40°C / 85°C
Accuracy
2%
Termination Style
Molex 436500300
Unit Weight
35g
Factory Pack Qty
4
Datasheet
Product Datasheet
Application Notes
FAQ
Fastron H31/110M & FCR-400-40R-5, Three Phase Proportional Phase Control Module with Heatsink, 4-20mA,0-5V,500K POT Input, 400VAC, 25 Amp Per Phase @ 50 Deg C
4-20mA,0-10V, or 500K POT Proportional Phase Control Input
Ratings from 25A to 80 Amp @ 180-280 VAC
SCR output for heavy industrial loads
Instantaneous turn-on output
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Specification
Trent part Number
H31/110M & FCR-400-40R-5
Switching Type
Phase Angle (Random Crossing)
Control Voltage
4-20mA,0-5V,500K POT Proportional Input
Load Current
25 Amp (rms) @ 50 Deg C, 30 Amp Per phase @ 40 Deg C
Surge Capability
500Amp (peak)
Special Feature
3 Phase Proportional Controller + SSR/3 Phase Voltage Regulator
Mounting Style
Panel Mount
Load Voltage Range
180-400VAC +10%
Max Non Repetitive Peak Voltage
600 Vp
Termination Style
Barrier Strip Screw
Dimensions
L:110 x W:125 x D:180mm
Unit Weight
2kg
Factory Pack Qty
20
Datasheet
FCR-400-40R
Product Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
Current Transducer, AT-AA9-D-1, AC Current Transducer, Average RMS, 10 Amps, 22-60VAC/DC Aux, 4-20mA output
Adjustable Zero and Span Setting
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type) or 0-10V/0-5V (For Direct Voltage Type)
Each unit needs just 50mm x 120mm depth DIN Rail cabinet space
Specification
Fastron Electronics Part Number
AT-AA9-D-1
Control Output
4-20mA Average RMS
Input
0-10 Amp rms
Over Range
x 1.2
Operating Temperature
0 - 60°C
Load Voltage
22 - 60VAC/DC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
DIN Rail Mount
Case Material
PC - UL 94 V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
LEM AT 100 B420L, AC Current Transformer, 20-30VDC loop powered, 100 Amp Average RMS, 4-20mA output
Features
Average RMS Output
Split Core
4-20mA Current Output
Cable Mounting
20-30VDC Loop Powered
Isolated plastic case recognised according to UL94-V0
Advantages
Large aperture for cable up to ? 16mm
High isolation between primary and secondary circuits
Easy installation
Applications
Current Measurement
Energy Management
Motor Control
Actuators
Lamp Failure
Specification
LEM Part Number
AT 100 B420L
Technology
AC Current Transformer
Protection Class
IP50
Supply Voltage
20-30VDC Loop Powered (10mA)
Load Current (RMS)
100 Amp
Maximum Measurement Current (RMS)
120 Amp
Output
4-20mA (Average RMS)
Isolation
3.5kV (AC, 50Hz, 1 min)
Bandwidth
55 - 65Hz
Mounting Style
Din Rail Mount
Operating Temperature Range
-10°C / 65°C
Accuracy
1.5%
Aperture
? 16mm
Termination Style
Screw
Approvals
CE,UL,ROHS
Unit Weight
90g
Factory Pack Qty
6
Datasheet
Product Datasheet