Fastron Electronics GT-AV(0-0.333)-D-2, Signal Isolator/Conditioner, 0-0.333V AC input, 22-60VAC/DC aux, 4-20mA Average RMS output
Adjustable Zero and Span Setting
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space
Specification
Fastron Electronics Part Number
GT-AV(0-0.333)-D-2
Control Output
4-20mA Average RMS
Input
0-0.333VAC
Over Range
x 1.5
Operating Temperature
0 - 60°C
Load Voltage
22 - 60VDC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
DIN Rail Mount
Case Material
PC - UL 94 V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
Fastron Electronics GT-AV(0-230)-A-VO(0-5), AC Voltage Transducer, 0-230V AC input, 100-240VAC/DC aux, 0-5V Average RMS output
Adjustable Zero and Span Setting
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space
Specification
Fastron Electronics Part Number
GT-AV(0-230)-A-VO(0-5)
Control Output
0-5V Average RMS
Input
0-230VAC
Over Range
x 1.5
Operating Temperature
0 - 60°C
Load Voltage
100-240VAC/DC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
DIN Rail Mount
Case Material
PC - UL 94 V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
VX9-USNA-A2T, Temp Controller, 96x96mm, 100-240VAC, Mutirange Input, SSR Output, 2 Alarms, Retransmission
Multirange Input (Programmable)
4-digit displays suit most industries including Temperature, Humidity, Pressure (0.5s response)
Drip-proof / Dust-proof IP65 (front panel only)
UL/CE Approved
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 60 mm depth panel space
EC Compliant
Specification
Hanyoung Nux Part Number
VX9-USNA-A2T
Control Output 1 (Heat)
SSR 12-15VDC @30mA
Control Output 2 (Cool)
N/A
Input
Multirange Type K/J/E/T/R/B/S/L/N/U/W/PLII/PT100/JPT100/4-20mA/0-20mA/1-5V/0-5V/0-10V/0-50mV/0-100mV. Note for Direct Current Input please use 250 Ohm Resistor in Parallel to the input terminals.
Alarm
Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)
Option 1
2nd Alarm Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)
Option 2
4-20mA (PV/SV/MV) Retransmission
Mounting Style
96x96mm Panel Mount
Supply Voltage
85 - 265VAC
Termination Style
Screw
Weight
450g
Factory Pack Qty
1
ROHS
Yes
UL
Yes
CE
Yes
Datasheet
VX Series Brochure
VX Series Instruction Manual
Free Software
Hanyoung Nux TCS Software
Hanyoung Nux TCS Software User Manual
VX Series SB Driver (Windows 7) Not required for Windows 10 or 11
Fastron Electronics FESCT-3000-1000, 1000Amp 0.333V Class 1 Measurement Split Core CT's, 1M Flying Leads, 76x127mm Aperture
Features
Quick Release Split Core System
1m Flying Leads
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.60/3kV
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Electronics Part Number
FESCT-3000-1000
Technology
Split Core AC Current Transformer
Ratio
1000/0.333V
Aperture Size
76x127mm
VA Rating
N/A
Accuracy Class
Class 1
Output
0.333VAC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 55°C
Continuous Current (max)
1000Amp x 1.2
Termination Style
Terminals
Unit Weight
3000g
Factory Pack Qty
9
Datasheet
Product Datasheet
Application Notes
Installation Guide
Techsem MTC1200-18-412F3D, Dual Thyristor Module, 1200 Amp, 1800V
Features
Thyristor for line frequency
Pressure Contact Technology
Electrically insulated base plate
Industrial standard package
Long-term stability
2500V Isolation
77mm Base Width
Applications
Power Converter
Line rectifying 50/60 Hz
Deep Cycle Applications
Controlled Rectifiers
Softstart AC motor control
AC power control
Lighting and temperature control
Specification
Techsem Part Number
MTC1200-18-412F3D
Vrrm
1800V
Diode Configuration
Dual Thyristor Module
IF(av) @ 85 Deg C
1200 Amp
Package Size
W:77mm L:180mm D:78mm
Itsm
34 kA
VF(to)
0.8V
Tj(max)
125°C
rF
0.09mΩ
I(gt) @ 25 Deg C
200mA
Terminals
M12 Screw
Hole Centres
132mm x 58mm(M6)
Gate Terminals
Spade (A 2.8 - 0.8 DIN 46244)
R th(j-c)
0.031°C/W
R th(c-h)
0.020°C/W
Weight
3500g
Mounting Torque
8 Nm (12 Nm Terminals)
Factory Pack Qty
2
Certification
UL Listed, ROHS
Techsem Headquarters
China
Datasheet
Product Datasheet
Rishabh Rish Con M-22132, Class 0.5 Power Transducer 4 wire, 20-480V L-L, 5Amp measurement, 85-253VAC/90-320VDC Supply, 4 x Analogue -20-20mA/4-20mA/-10-10V output, USB Programming Port, Modbus RTU Comms, 750 OHM Load Resistance, without display
Measures Active Power/Phase Angle/Power Factor
Measures Apparent/Reactive/Active Power
Analogue output setting 0-20mA/4-20mA/0-10V
300mS response time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 122.5 x 66 x 106.5mm depth DIN Rail cabinet space
Specification
Rishabh Part Number
Rish Con M-22132
Functions
Active Power/Phase Angle/Power Factor Transducer 4 wire
Measurement Output
4 x 4-20mA/0-20mA/0-10V User Selectable
Relay Output
N/A
Relay Type
Voltage Free Contact, 0.5 Amp @ 250VAC
Input
20 - 480VAC L-L 50/60Hz
Overload (Continuous)
120%
Overload (1 second)
150%
Operating Temperature
-10 - 55°C
Supply Voltage
85-253VAC/90-320VDC
Accuracy
0.2%
Response Time
300mS
Termination Style
Screw
Mounting Style
DIN Rail Mount
Mounting Size
122.5 x 66 x 106.5mm
Safety
IP40/IP20 EN60529 Protection Class II EN61010
Weight
400g
Factory Pack Qty
1
Datasheet
Product Datasheet
Product User Manual
Technical Support
Rish Con P setup procedure blog
Fastron Electronics GA5-A-V7-D-N, 96x48mm 5 DIGIT Digital Ammeter 0-600VAC input, 22-60VAC/DC Supply, Large 5 Digit
Adjustable Zero and Span Setting
Adjustable Display Scaling
Large 5 Digit 20.3mm (8 Inch) LED Display
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 96 x 48mm Panel Space
90mm Depth
Specification
Fastron Electronics Part Number
GA5-A-V7-D-N
Conditioner Output
N/A
Input
4-20mA
Over Range
x 1.5
Operating Temperature
0 - 60°C
Load Voltage
22-60VAC/DC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
96 x 48mm Panel Mount (60mm depth)
Case Material
PC - UL 94 V0
Weight
320g
Factory Pack Qty
1
Datasheet
Product Datasheet
Application Notes
Panel Meters Blog Articles
HS212DR-F, Heatsink 110mm, Milled, Drilled and Tapped for 3 Phase & Single Phase SSR, 0.35°C/W
Datasheet
HS212 Datasheet
Heatsink products are mostly made to order and require 2-3 days more to produce.
Fastron Electronics GT-2A6-A-1, Signal Isolator/Conditioner, 4-20mA Loop Supply Sensor Input, 4-20mA Output, 100-240VAC/DC
Adjustable Zero and Span Setting
250mS Response Time
PC 94 UL V0
Input signals can be converted from 4 to 20 mA DC Loop Supply (Sensor Input) to insulated 4-20mA Standard Process Output
Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space
Specification
Fastron Electronics Part Number
GTD-2A6-A-1
Control Output
4-20mA Standard
Input
4-20mA Sensor Input (Loop Powered)
Over Range
x 1.5
Operating Temperature
0 - 60°C
Supply Voltage
100-240VAC/DC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
DIN Rail Mount
Case Material
PC - UL 94 V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
Crydom DR06D12, Solid State Relay, 4-32VDC control, 12 Amp 1-60VDC Output, Slimline, Din Rail Mount, LED status Indicator
Features
Ratings from 3 Amp, 1-100VDC, 1-60VDC, 24-280VAC, 48-600VAC
DIN Rail Mount
SCR output for reliable AC switching, or Mosfet for DC Switching
Ultra slim package
UL/CSA/VDE Approved, CE Compliant to EN60950-1
EMC compliant to Level 3
Epoxy free design
Spec
Crydom Part Number
DR06D12
Switching Type
DC
ROHS
Yes (Details)
Control Voltage
4-32VDC
Load Current
12 Amp (rms)
Surge Capability (10ms)
60 Amp (peak)
Special Feature
LED Status Indicator
Mounting Style
DIN Rail Mount
Load Voltage Range
1-60VDC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
38g
Factory Pack Qty
20
Datasheet
Product Datasheet
Equivalent
DRA1-CMX60D10
ED06C5
ED06D5
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
PIB12C, 48x96mm, Panel Meter, DC Ammeter DC Voltmeter Input 0-10V/4-20mA/RTD/Thermocouple, 2 x Alarm Outputs SPDT 5A @ 250VAC/24VDC (SPDT), Retransmission Output 0-20mA/4-20mA/0-10V/0-5V, 24VDC Sensor Supply, 85-270VAC/DC Supply, Modbus RS485
Fixed Zero and Span Setting
Adjustable Display Scaling
4 Digit LED Display
100mS Response Time
PC 94 UL V0
Each unit needs just 96 x 48mm Panel Space
65mm Depth
CE Approved
Specification
Fastron Electronics Part Number
PIB12C
Conditioner Output
0-20mA/4-20mA/0-10V/0-5V,
Input
0-10V/4-20mA/RTD/Thermocouple
Retransmission
Programmable 0-20mA/4-20mA/0-10V/0-5V
Over Range
x 1.5
Loop Sensor Supply
24VDC @ 30mA
Relay Outputs
2 Relays with 1 x NO, 1 x NC (SPDT ) 5 Amp @ 250VAC/24VDC
Operating Temperature
0 - 60°C
SupplyVoltage
85-270VAC/DC
Span Adjustment Range
N/A
Zero Adjustment Range
N/A
Termination Style
Screw
Display Type
4.0 Digit RED LED
Mounting Style
96 x 48mm Panel Mount
Case Material
PC - UL 94 V0
Weight
250g
Factory Pack Qty
1
Datasheet
Product Datasheet
Application Notes
Panel Meters Blog Articles
Rishabh Rish Con P 4WUB 100-500V 1/5A 60-300U 20 D, Active Power/Reactive Power/Apparrent Power/Phase Angle/Power Factor Transducer 4 wire, 100-500V, 5Amp measurement,60-300VAC/DC Supply, 2 x 0-20mA/4-20mA/0-10V output, with display
Measures Active Power/Phase Angle/Power Factor
Measures Apparent/Reactive/Active Power
Digital output setting 0-20mA/4-20mA/0-10V
Dual output version available
300mS response time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 43.75 x 100.9 mm depth DIN Rail cabinet space
Specification
Rishabh Part Number
Rish P 4WUB 100-500V 1/5A 60-300U 20 D
Functions
Power/Phase Angle/Power Factor Transducer 4 wire
Measurement Output
4-20mA/0-20mA/0-10V User Selectable
Input
57 - 500VAC 50/60Hz
Overload (Continuous)
120%
Overload (1 second)
150%
Operating Temperature
-40 - 70°C
Supply Voltage
60 - 300VAC, or 24-60VAC/DC
Accuracy
0.2%
Response Time
300mS
Termination Style
Screw
Mounting Style
DIN Rail Mount
Safety
IP40/IP20 EN60529 Protection Class II EN61010
Weight
400g
Factory Pack Qty
1
Datasheet
Product Datasheet
Technical Support
Rish Con P setup procedure blog