Search results for "multimeter"
-
FESCTHY-32-300-100mV, 300Amp measurement Split Core CT's, w/1M Flying Leads, HY2.0 Connection, 32x32mm Aperture
Fastron Electronics FESCTHY-32-300-100mV, 300 Amp, 100mV Class 1 Series Current Transformer Features Quick Release Split Core System 1m Flying Leads Mounting Feet Supplied Self Powered Rated System Voltage 0.60/2kV Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number FESCTHY-32-300-100mV Technology Split Core AC Current Transformer Ratio 300/100mV Aperture Size 32 x 32mm VA Rating N/A Accuracy Class Class 1 Output 100mVAC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 55°C Continuous Current (max) 300Amp x 1.2 Termination Style 1M Twisted Pair 0.34mm^2 Unit Weight 350g Factory Pack Qty 9 Datasheet Product Datasheet
$82.50
$97.35 inclGST -
FESCTHY-32-400-100mV, 400Amp measurement Split Core CT's, w/1M Flying Leads, HY2.0 Connection, 32x32mm Aperture
Fastron Electronics FESCTHY-32-400-100mV, 400 Amp, 100mV Class 1 Series Current Transformer Features Quick Release Split Core System 1m Flying Leads Mounting Feet Supplied Self Powered Rated System Voltage 0.60/2kV Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number FESCTHY-32-400-100mV Technology Split Core AC Current Transformer Ratio 400/100mV Aperture Size 32 x 32mm VA Rating N/A Accuracy Class Class 1 Output 100mVAC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 55°C Continuous Current (max) 400Amp x 1.2 Termination Style 1M Twisted Pair 0.34mm^2 Unit Weight 350g Factory Pack Qty 9 Datasheet Product Datasheet
$82.50
$97.35 inclGST -
SCT-F50-1000, 0.333V, 1000Amp measurement Split Core CT's
Fastron Electronics SCT-F50-1000, 0.333V, 1000Amp measurement Split Core CT's Features Quick Release Split Core System Cable Mount 0.333V Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number SCT-F50-1000 Technology Split Core AC Current Transformer Ratio 1000/0.333V Aperture Size ø 50 mm VA Rating N/A Accuracy Class Class 1 Output 0.333V (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 1000Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 1000g Factory Pack Qty 9 Datasheet Product Datasheet Stocked Split Core CT's Listing Application Notes Installation Guide Types of Current Transformers - Blog Cable Losses and CT's High Accuracy or High Burden Requirements for CT's
$110.55
$130.45 inclGST -
SCT-F50-800, 0.333V, 800Amp measurement Split Core CT's
Fastron Electronics SCT-F50-800, 0.333V, 800Amp measurement Split Core CT's Features Quick Release Split Core System Cable Mount 0.333V Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number SCT-F50-800 Technology Split Core AC Current Transformer Ratio 800/0.333V Aperture Size ø 50 mm VA Rating N/A Accuracy Class Class 1 Output 0.333V (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 800Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 800g Factory Pack Qty 9 Datasheet Product Datasheet Stocked Split Core CT's Listing Application Notes Installation Guide Types of Current Transformers - Blog Cable Losses and CT's High Accuracy or High Burden Requirements for CT's
$110.55
$130.45 inclGST -
SCT-F50-600, 0.333V, 600Amp measurement Split Core CT's
Fastron Electronics SCT-F50-600, 0.333V, 600Amp measurement Split Core CT's Features Quick Release Split Core System Cable Mount 0.333V Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number SCT-F50-600 Technology Split Core AC Current Transformer Ratio 600/0.333V Aperture Size ø 50 mm VA Rating N/A Accuracy Class Class 1 Output 0.333V (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 600Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 600g Factory Pack Qty 9 Datasheet Product Datasheet Stocked Split Core CT's Listing Application Notes Installation Guide Types of Current Transformers - Blog Cable Losses and CT's High Accuracy or High Burden Requirements for CT's
$110.55
$130.45 inclGST -
SCT-F50-500, 0.333V, 500Amp measurement Split Core CT's
Fastron Electronics SCT-F50-500, 0.333V, 500Amp measurement Split Core CT's Features Quick Release Split Core System Cable Mount 0.333V Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number SCT-F50-500 Technology Split Core AC Current Transformer Ratio 500/0.333V Aperture Size ø 50 mm VA Rating N/A Accuracy Class Class 1 Output 0.333V (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 500Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 500g Factory Pack Qty 9 Datasheet Product Datasheet Stocked Split Core CT's Listing Application Notes Installation Guide Types of Current Transformers - Blog Cable Losses and CT's High Accuracy or High Burden Requirements for CT's
$110.55
$130.45 inclGST -
SCT-F50-150, 0.333V, 150Amp measurement Split Core CT's
Fastron Electronics SCT-F50-150, 0.333V, 150Amp measurement Split Core CT's Features Quick Release Split Core System Cable Mount 0.333V Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number SCT-F50-150 Technology Split Core AC Current Transformer Ratio 150/0.333V Aperture Size ø 50 mm VA Rating N/A Accuracy Class Class 1 Output 0.333V (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 150Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 150g Factory Pack Qty 9 Datasheet Product Datasheet Stocked Split Core CT's Listing Application Notes Installation Guide Types of Current Transformers - Blog Cable Losses and CT's High Accuracy or High Burden Requirements for CT's
$110.55
$130.45 inclGST -
SCT-F36-400, 0.333V, 400Amp Measurement, Class 1 Split Core CT's Class 1, 35mm Aperture
Fastron Electronics SCT-F36-400, 0.333V, 400Amp measurement Split Core CT's Class 1, 35mm Aperture Features Quick Release Split Core System Cable Mount 0.333V Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number SCT-F36-400 Technology Split Core AC Current Transformer Ratio 400/0.333V Aperture Size ø 35 mm VA Rating N/A Accuracy Class Class 1 Output 0.333V (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 400Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 400g Factory Pack Qty 9 Datasheet Product Datasheet Stocked Split Core CT's Listing Application Notes Installation Guide Types of Current Transformers - Blog Cable Losses and CT's High Accuracy or High Burden Requirements for CT's
$66.50
$78.47 inclGST -
Power Rail 350-M2, kWh Meter, 3 Phase, DIN Rail, 240VAC aux, Class 1, 5Amp input, w/ pulse output, Power quality measurements
Free Aus Post Shipping for $300 SpendNorthern Design Power Rail 350-M2 Three Phase Power Meter 5 Amp CT Input Optional RS 232/RS 485 communication up to 19,200 bit/s True RMS values of currents and voltages Power Quality Measurements The meter is intended for measuring, and monitoring single-phase or electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, Hours Run, Peak Demand etc to the 30th Harmonic) from the measured signals. Features : Accuracy class 1 Measurement of Active and Reactive Power Optional MODBUSRS 232/RS 485 communication up to 19,200 bit/s communication Pulse output as standard Graphic LCD with illumination Specification Northern Design Part Number Power Rail 350-M2 Functions Three Phase Energy Meter Supply Voltage 230V L-N, 5 Amp +/-15% < 5VA Nominal Measurement Range 415V L-L 230V L-N, 5 Amp +/-15% Maximum Measurement Range 480V L-L 230V L-N, 5 Amp +/-15% Nominal Current Input 5 Amp AC Pulse Output 3 x NO Voltage Free Contacts 100mA @ 100VAC/DC Accuracy Class 1 (I,U,F,PF,) Class 2 (Reactive) Mounting Din Rail Real Time Clock 1min/month (30ppm) Internal Memory N/A Dimensions 106mm x 90mm x 58mm (6 modules wide) Isolation 3.5kV RS232/RS485 (Optional 1200-19200 b/s) Weight 150g Certification EN 61010-1 Installation Category III Factory Pack Qty 1 Enclosure Material Noryl with fire protection to UL94-V-O. Self extinguishing Enclosure Size DIN 42880 6 Modules Operating Temperature -20 →+70 °C Datasheet Product Datasheet Product Manual Product Comms Manual Option Links Application Notes CT Cable Losses Meter Accuracy at Low Current Current Input Isolation
Free Aus Post Shipping for $300 Spend$298.00
$351.64 inclGST -
RCT-1200-1000 0.333V, Single Phase, 1000Amp AC Measurement, 6 Inch Rogowski Coil Integrator, Class 1
Free Aus Post Shipping for $300 SpendRCT-1200 Single Phase Flexible Current Sensor System: The RCS-1200 Single Phase flexible rope CT from Magnelab converts AC input current of up to 5000 amperes to an AC output of 0.333 volt. A 9 to 36 VDC power supply is required to operate these coils. The RCS-1200 comes with an integrator which includes flexible strain relief cables. Included is an 12 inch circumference rope CT with Integrator, and 8 feet of twisted pair (600V) output leads. Magnelab Coils come with 10 year warranty Specification Magnelab Part Number RCT-1200-1000 Function AC Current Measurement Nominal Measurement Current (Ipn) 1000 Amp RMS Measurement Range 10% - 130% if Ipn Frequency Measuring Range 50-1500Hz (15th Harmonic) Operating Voltage 9 - 36VDC Accuracy 1% from 25 to 1000 Amp Phase Angle < 0.5 Degrees Coil Diameter (⌀) 4 Inch Coil Circumference 12 Inch Integrator to Coil Cable 8 Feet Shielded Maximum Voltage 600V (on bare conductor) Operating Temperature -15°C to 65°C Storage Temperature -45°C to 80°C Power Consumption < 2VA Overload 20,000 Amp (continuous) Termination Style Screw Weight 1200g Certification CE Factory Pack Qty 1 Certifications UL Recognized E96927 to IEEE C57.13, CAN/CSA 60044-1 Meets UL STD 61010-1, CAN/CSA C22.2 No. 61010 CE ROHS Datasheet Product Datasheet Application Notes RCS/RCT Series Installation Guide
Free Aus Post Shipping for $300 Spend$335.00
$395.30 inclGST -
Rish Xmer 74-20 (45) 150/5 Class 0.2S, 2.5VA, 21mm Aperture
Rish Xmer 74-20 (45) 150/5 Class 0.2S, 2.5VA, 21mm Aperture Features High Accuracy Class 0.2S Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Rishabh Part Number Rish Xmer 74-20 (45) 150/5 Class 0.2S Technology AC Current Transformer Ratio 800/5 Aperture Size 21x11mm VA Rating 2.5VA Accuracy Class Class 0.2S Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -25°C / 40°C Continuous Current (max) Ipn x 1.2 Termination Style Screw Unit Weight 500g Factory Pack Qty 9 Datasheet Product Datasheet
$82.00
$96.76 inclGST -
FESCTHY-3000-1500-100mV, 1500Amp 100mV Class 1 Measurement Split Core CT's, 1M Flying Leads, HY2.0 Connection, 76x127mm Aperture
Fastron Electronics FESCTHY-3000-1500, 1500Amp 100mV Class 1 Measurement Split Core CT's, 1M Flying Leads, 76x127mm Aperture Features Quick Release Split Core System 1m Flying Leads Mounting Feet Supplied Self Powered Rated System Voltage 0.60/3kV Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Electronics Part Number FESCTHY-3000-1500 Technology Split Core AC Current Transformer Ratio 1500/100mV Aperture Size 76x127mm VA Rating N/A Accuracy Class Class 1 Output 100mVAC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 55°C Continuous Current (max) 1500Amp x 1.2 Termination Style Terminals Unit Weight 3000g Factory Pack Qty 9 Datasheet Product Datasheet Installation Guide FESCTHY Install Guide
$208.00
$245.44 inclGST