Premium Quality TC Cable 100M Teflon - Type R Thermocouple Cable 100 Meter Twisted and Screened 7/0.2mm, ANSI Standard
Features
CE, ANSI, ROHS Approved
Colour Codes
Datasheet
Thermocouple Cable Brochure
Premium Quality Type N Thermocouple cable per Meter, Teflon Twisted and Screened ANSI Standard
Features
CE, ANSI, ROHS Approved
Colour Codes
Datasheet
Thermocouple Cable Brochure
Infineon DD600N12K, Dual Diode Module, 600 Amp, 1200V, 60mm Base
Features
Pressure Contact Technology
Electrically insulated base plate
Very low forward voltage drop
Very low leakage current
Planar passivated chips
International standard package
3600V Isolation
60mm Base Width
Applications
Power Supplies
Rectifier for drives applications
Uncontrolled Rectifiers
Rectifiers for UPS
Battery Chargers
Filed Supply for DC Motors
DC supply for PWM inverter
Specification
Infineon Part Number
DD600N12K
Vrrm
1200V
Diode Configuration
Dual Diode Module
IF(av) @ 100 Deg C
600 Amp
Package Size
W:60mm L:101mm D:52mm
Itsm
22 kA
VF(to)
0.75V
Tj(max)
150°C
rF
0.215mΩ
Terminals
M10 Bolt
Hole Centres
80mm x 38mm (M6)
Gate Terminals
N/A
R th(j-c)
0.078°C/W
R th(c-h)
0.02°C/W
Weight
900g
Mounting Torque
5 Nm (12 Nm Terminals)
Factory Pack Qty
2
Certification
UL Listed, ROHS
IXYS Headquarters
United States
Datasheet
Product Datasheet
Alternatives
MDC600-416F3
Hobut CT105F-160/5-2.5/1 Class 1, 2.5VA 160 Amp, 5 Amp Output, 3 Phase Current Transformer, With Feet Mount
Features
Built In Sealable Terminal Covers
Mounting Feet Supplied
Narrow Width (45mm)
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Hobut Part Number
CT105F-160/5-2.5/1
Technology
AC Current Transformer
Ratio
160/5
Aperture Size
21 x 25mm
VA Rating
2.5VA
Accuracy Class
Class 1
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Din Rail Mount
Operating Temperature Range
-30°C / 85°C
Continuous Current (max)
160Amp x 1.2
Termination Style
Screw
Unit Weight
450g
Factory Pack Qty
9
Datasheet
Product Datasheet
Fastron Electronics GT-2A6-A-1, Signal Isolator/Conditioner, 4-20mA Loop Supply Sensor Input, 4-20mA Output, 100-240VAC/DC
Adjustable Zero and Span Setting
250mS Response Time
PC 94 UL V0
Input signals can be converted from 4 to 20 mA DC Loop Supply (Sensor Input) to insulated 4-20mA Standard Process Output
Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space
Specification
Fastron Electronics Part Number
GTD-2A6-A-1
Control Output
4-20mA Standard
Input
4-20mA Sensor Input (Loop Powered)
Over Range
x 1.5
Operating Temperature
0 - 60°C
Supply Voltage
100-240VAC/DC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
DIN Rail Mount
Case Material
PC - UL 94 V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
LEM LV 100-2000/SP15, C/L Hall Effect Voltage Transducer, 2000V, 50mA Output
Features
Bipolar and insulated voltage measurement up tp 3000VAC/DC
Current output
Closed loop (compensated) voltage transducer
Panel mounting
Insulated plastic case recognized according to UL 94-V0
Advantages
Very good linearity
High accuracy
Low offset drift over temperature
Wide frequency bandwidth
Very low insertion losses
High immunity to external interference
Low power consumption
Applications
Railway Equipment
Windmill Inverters
Test and Measurement
Substations
AC variable speed drives and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Application Domain
Industrial
Traction
Standards
EN 50178:1997
IEC61010-1:2010
UL 508:2010
Specification
LEM Part Number
LV 100-2000/SP15
Technology
Closed Loop Hall Effect
Aperture
No Aperture
ROHS
Yes
Supply Voltage
+/- 15 VDC Bipolar, Isolated
Primary RMS Voltage
2000V
Measurement Range
+/- 3000V
Output
50 mA
Isolation
9 kV
Response
70uS
Mounting Style
Panel Mount
Operating Temperature Range
-10°C / 70°C
Accuracy
0.7%
Termination Style
Faston 45° 6.3 x 0.8mm and M5 threaded studs
Unit Weight
870g
Factory Pack Quantity
6
Datasheet
Product Datasheet
Crydom H12D4840D, Dual Solid State Relay, Two Pole 3-15VDC Control, 2 x 40A, 48-530VAC Load
Features
Ratings from 2 x 25A to 2 x 40 Amp @ 48-480VAC
SCR output for heavy industrial loads
Zero voltage or instantaneous turn-on outputs
UL/CSA/VDE Approved, CE Compliant to EN60950-1
Improved SEMS screw and washer
Redesigned housing with anti-rotation barriers
AC & DC control types
Direct bond copper substrate
EMC compliant to Level 3
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
H12D4840D
Switching Type
Zero Crossing (Dual)
ROHS
Yes (Details)
Control Voltage
3-15VDC
Load Current
2 x 40 Amp (rms)
Surge Capability
597 Amp (peak)
Special Feature
Dual SSR, 1200V Transient Withstand
Mounting Style
Panel Mount
Load Voltage Range
48-530VAC
EMC Compliant
Level 3
Termination Style
faston
Unit Weight
89g
Factory Pack Qty
20
Datasheet
Product Datasheet
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
Equivalent
See CC4850W3VH
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
ND4C-40, 6 Amp Snap on Auxiliary Contacts for K03, K07 and K08 Series Miniature Contactors, 4 x NO Aux Contacts
Features
Snap on
4 x NO, 6 Amp Contacts
20 grams