Crydom RPC2440, Phase Angle Controller, for 500K - 1M POT input, 240VAC, 40 Amps out
Features
150k Ohm POT Phase Control Input
Ratings from 15A to 40 Amp @ 70-280 VAC
SCR output for heavy industrial loads
Instantaneous turn-on outputs
UL/CE/ROHS Compliant
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
RPC2440
Switching Type
Phase Angle (Random Crossing)
ROHS/CE/UL
Yes
Control Input
500K-1M Ohm POT
Load Current
40 Amp (rms)
Surge Capability
625 Amp (peak)
Special Feature
Proportional Controller + SSR
Mounting Style
Panel Mount
Load Voltage Range
70-280VAC
Max Non Repetitive Peak Voltage
850 Vp
Termination Style
Screw
Unit Weight
160g
Factory Pack Qty
20
Datasheet
Product Datasheet
Equivalent
Relequick RS1API420MA280060R RS1API420MA280080R or Crydom MCPC2450 MCPC2490 or Contact Us for Possible Replacement
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Fastron Electronics GTD-2A6-D-1, Signal Isolator/Conditioner, 4-20mA Loop Supply Sensor Input, 22-60VAC/DC
Adjustable Zero and Span Setting
250mS Response Time
PC 94 UL V0
Input signals can be converted from 4 to 20 mA DC Loop Supply (Sensor Input) to insulated 4-20mA Standard Process Output
Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space
Specification
Fastron Electronics Part Number
GTD-2A6-D-1
Control Output
4-20mA Standard
Input
4-20mA Sensor Input (Loop Powered)
Over Range
x 1.5
Operating Temperature
0 - 60°C
Supply Voltage
22 - 60VDC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
DIN Rail Mount
Case Material
PC - UL 94 V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
Crydom DR24A06, Solid State Relay, 208-265VAC control, 6 Amp 24-280VAC Output, Slimline, Din Rail Mount, LED status Indicator
Features
Ratings from 3 Amp, 6 Amp, 12 Amp 1-100VDC, 1-60VDC, 24-280VAC, 48-600VAC
DIN Rail Mount
SCR output for reliable AC switching, or Mosfet for DC Switching
Ultra slim package
UL/CSA/VDE Approved, CE Compliant to EN60950-1
EMC compliant to Level 3
Epoxy free design
Spec
Crydom Part Number
DR24A06
Switching Type
AC
ROHS
Yes (Details)
Control Voltage
208-265VAC
Load Current
6 Amp (rms)
Surge Capability (10ms)
285 Amp (peak)
Special Feature
LED Status Indicator
Mounting Style
DIN Rail Mount
Load Voltage Range
24-280VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
50g
Factory Pack Qty
20
Datasheet
Product Datasheet
Equivalent
Similar part
ks32-60-24z2-f41f-1z-c2-4
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Fastron FDV-300-V05-24, DC Voltage Transducer, Din Rail Mount, 0-300VDC, 0-5V output, 24VDC Supply Voltage, 150mS Response
150mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 5V DC output (for voltage output type)
Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space
Specification
Fastron Part Number
FDV-300-V05-24
Analogue Output
0-5V
Input
0 - 300VDC
Measurement Range
120%
Overload
150% Continuous
Operating Temperature
-30 - 70°C
Operating Voltage
24VDC +/-15%
Voltage Isolation (1 min)
2.5kV
Accuracy
1%
Response Time
150mS
Termination Style
Screw
Mounting Style
DIN Rail Mount
Safety
CE, UL94V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
Fastron FTM1-A05-V2-W0, Single Phase, Phase Angle/Burst Controller for Primary Control of Transformer (Phase Angle mode only), Voltage/Current/Power Limit Modes, For Single Phase Loads, 230VAC, 4 Amps @ 50 Deg C, Modbus RTU
Features
Phase Angle, and Burst Control Functions
Made in China, Low cost
Single Phase, Angle/Burst Controller
4-20mA/0-10V/0-5V input Proportional Control
Phase Angle or Burst switching
Digital Display and Controls
Modbus RTU
Applications
Electrical Ovens, Kilns, or Furnaces
HVAC Heaters
Controlled Power Applications
Electric Boilers
Brewery Heating
Industrial Light Dimming
Suitable for HVAC or Industrial Environments
Specification
Fastron Part Number
FTM1-A05-V2-W0
Rated Operating Temperature
50°C
SCR Configuration
3 Phase AC Switch
Control Voltage
4-20mA/0-10V/0-5V/POT
Load Current
4 Amps Per Phase @ 50 Deg C
Derating
2% per 1 Deg C (approx)
Control Range
0-100%
Alarms
1 x NO Relay Contacts
Special Feature
Internal Fuse, Current Limit, Power Limit
Comms
Modbus RTU
Mounting Style
Panel Mount
Switching Voltage Range
230VAC +/-10%
Supply Voltage
230VAC +/-10%
Dimensions
H:260mm W:94mm D:187mm
Soft Start
N/A
Termination Style
Screw
Unit Weight
2.5kg (4kg Packed)
Factory Pack Qty
1
Technical Docs
User Manual
Brochure
Video for How to Set Current/Voltage/Power limit
Fastron GPH10048ZA3, Solid State Contactor SSR, Single Phase 90-280VAC Control, 100A, 70-480VAC Load, Din Rail Mount
Ratings from 10A to 100 Amp @ 70-480 VAC
Contactor Style for retrofit
SCR output for heavy industrial loads
Zero voltage or instantaneous turn-on outputs
CE Compliant to EN60950-1
IP20
AC & DC control types
Direct bond copper substrate
EMC compliant to Level 3
Direct power lead frame
Spec
Fastron Part Number
GPH10048ZA3
Switching Type
Zero Crossing
ROHS
Yes (Details)
Control Voltage
90-280VAC
Load Current (single unit)
92 Amp (rms) @ 20 Deg C Ambient, 68 Amp (rms) @ 40 Deg C Ambient
Surge Capability
1600 Amp (peak)
Special Feature
Contactor Style IP20 Terminals
Mounting Style
DIN Rail Mount
Load Voltage Range
70 - 480VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
500g
Factory Pack Qty
20
Datasheet
Product Datasheet
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
DCBT-050-24-420, Hall Effect DC Current Transducer, +/-50 Amp DC, 4-20mA bipolar output, 24VDC supply, 20mm Aperture
Compact and versatile Split Core DC current sensor, +/-50 Amp DC, 4-20 mA Bipolar Output
Features
⌀20mm Aperture
DC Bipolar Measurement
4-20mA analogue output
Busbar, or panel mounting
Isolated plastic case recognised according to UL94-V0
Advantages
High isolation between primary and secondary circuits
Easy installation
DIN Rail Kit available
Applications
-Automation Systems
Analogue current reading for remote monitoring (e.g. Motor)
-Data Loggers
Self Powered. Will not drain data logger batteries
-Panel Meters
Simple connection displays power consumption
Specification
Fastron Part Number
DCBT-050-24-420
Technology
DC Hall Effect Current Transducer with Instant Output
Yes
Supply Voltage
24VDC
Nominal Current (RMS + DC)
+/-50 Amp
Response Time
< 1uS
Output
Bipolar 4-20mA Analogue
Isolation
2.5kV (AC, 50Hz, 1 min)
Bandwidth
DC
Aperture
20mm
Mounting Style
Panel Mount
Operating Temperature Range
-40°C / 85°C
Accuracy
1%
Termination Style
Molex 4 Pin
Unit Weight
120g
Factory Pack Qty
6
Datasheet
Product Datasheet
Fastron FJTY220D80P, Single Phase Intelligent Phase or Burst Control Module with 2 second Soft Start, 4-20mA,0-10V,0-5V,10K POT Input, 220VAC, 80 Amp Per Phase, Voltage Regulator
4-20mA,0-10V, 0-5V or 10K POT Proportional Phase Control Input
Ratings from 25A to 80 Amp @ 180-280 VAC
SCR output for heavy industrial loads
Instantaneous turn-on output
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Specification
Trent part Number
FJTY220D80P
Switching Type
Phase Angle (Random Crossing)/ Burst Fire (10 cycles)
Control Voltage
4-20mA,0-10V,0-5V,10K POT Proportional Input
Load Current
80 Amp (rms)
Surge Capability
690Amp (peak)
Special Feature
Single Phase Proportional Controller + 2 Second Soft Start + Selectable Half Wave control
Mounting Style
Panel Mount
Load Voltage Range
170-220VAC +15% (253VAC Max)
Max Non Repetitive Peak Voltage
600 Vp
Termination Style
Barrier Strip Screw
Dimensions
105 x 80 x 55mm
Unit Weight
400g
Factory Pack Qty
20
Datasheet
FJTY Series Voltage Regulators
Fastron FRTD-6-250-500 Resistance Temperature Detectors (RTD's)
Class B Accuracy
Pt100 output
Teflon Screened Cable
Low Long Term Drift
Rated for -50 to 350 Deg C Max
250 x 6mm
MIMS
Recommended to use BSP Fitting for mounting
Specification
Fastron Part Number
FRTD-6-250-500
Sensor Type
RTD - Resistance Temperature Detectors
No of Wires
3
Shaft Length
250mm
Shaft Thickness
6mm
Accuracy
Class B
Cable length
500cm
Cable Type
Teflon/Teflon
Terminal Head Type
N/A
Maximum Temperature
-50 to 350 Deg C
Special Feature
N/A
Mounting Style
BSP Bayonet or Flange Fitting Recommended
Weight
300g
Factory Pack Qty
1
Datasheet
Datasheet
Crydom A2450G, Solid State Relay, Single Phase 90-280VAC Control, 50A, 24-280VAC Load, w/status LED
Features
• Ratings from 25A to 125 Amp @ 24-280 VAC
• SCR output for heavy industrial loads
• Zero voltage or instantaneous turn-on outputs
• UL/CSA/VDE Approved, CE Compliant to EN60950-1
• Improved SEMS screw and washer
• Redesigned housing with anti-rotation barriers
• AC & DC control types
• Direct bond copper substrate
• EMC compliant to Level 3
• Direct power lead frame
• Epoxy free design
Spec
Crydom Part Number
A2450G
Switching Type
Zero Crossing
ROHS
Yes (Details)
Control Voltage
90 - 280VAC
Load Current
50 Amp (rms)
Surge Capability
597 Amp (peak)
Special Feature
LED Status Indicator
Mounting Style
Panel Mount
Load Voltage Range
24-280VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
75g
Factory Pack Qty
20
Datasheet
Product Datasheet
Please note Changes from Gen 3 to Gen 4 (current) package design here
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Fastron Electronics FESCT-075-1200-1-IP65, 1200Amp Measurement, 1 Amp Output Split Core CT's, Class 1, 10VA, w/10M Flying leads, ø 75mm Aperture
Features
Quick Release Split Core System
10m Flying Leads
ø 75mm
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.60/3kV
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurement, 1 Amp Outputs
Specification
Fastron Electronics Part Number
FESCT-075-1200-1-IP65
Technology
Split Core AC Current Transformer
Ratio
1200/5A
Aperture Size
ø 75mm
VA Rating
10VA
Accuracy Class
Class 1
Output
1 Amp (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Dimensions
180x138x52mm
Mounting Style
Panel Mount
Operating Temperature Range
-35°C / 55°C
Continuous Current (max)
1200Amp x 1.2
Termination Style
10M Twisted Pair 0.34mm^2
Unit Weight
2000g
Factory Pack Qty
9
Datasheet
Product Datasheet
Application Notes
Installation Guide
Crydom D2475, Solid State Relay, Single Phase 3-32VDC Control, 75A, 24-280VAC Load
Features
• Ratings from 25A to 125 Amp @ 24-280 VAC
• SCR output for heavy industrial loads
• Zero voltage or instantaneous turn-on outputs
• UL/CSA/VDE Approved, CE Compliant to EN60950-1
• Improved SEMS screw and washer
• Redesigned housing with anti-rotation barriers
• AC & DC control types
• Direct bond copper substrate
• EMC compliant to Level 3
• Direct power lead frame
• Epoxy free design
Spec
Crydom Part Number
D2475
Switching Type
Zero Crossing
ROHS
Yes (Details)
Control Voltage
3-32VDC
Load Current
40 Amp (rms)
Surge Capability
954 Amp (peak)
Special Feature
None
Mounting Style
Panel Mount
Load Voltage Range
24-280VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
75g
Factory Pack Qty
20
Datasheet
Product Datasheet
Please note Changes from Gen 3 to Gen 4 (current) package design here
Alternatives
See HD48125 or Contact Us for Possible Replacement
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies