Fastron Electronics GTD-DA6-D-11, Signal Conditioner/Voltage Transducer, 4-20mA input, 22-60VAC/DC aux, Dual 4-20mA outputs
Adjustable Zero and Span Setting
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space
Specification
Fastron Electronics Part Number
GTD-DA6-D-11
Conditioned Output
2 x 4-20mA
Input
4-20mA
Over Range
x 1.5
Operating Temperature
0 - 60°C
Load Voltage
22 - 60VDC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
DIN Rail Mount
Case Material
PC - UL 94 V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
Crydom HS501DR + MCBC4825CF, Single Phase Proportional Burst Controller with Heatsink, 10 Cycles, 0-10VDC Input, 90-530VAC, 9 Amps
Features
Proportional Phase Control Input
Ratings from 25A to 90 Amp @ 380-530 VAC
SCR output for heavy industrial loads
Zero voltage or instantaneous turn-on outputs
UL/CE/ROHS Compliant
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Spec
Part Number
HS501DR + MCBC4825CF
Switching Type
Burst Fire (Zero Crossing)
ROHS/CE/UL
Yes
Control Voltage
0-10V Proportional Input
Load Current
9 Amp (rms) @ 40 Deg C
Surge Capability
239 Amp (peak)
Special Feature
Proportional Controller + SSR
Mounting Style
DIN Rail or Panel Mount
Load Voltage Range
380-530VAC
Max Non Repetitive Peak Voltage
600 Vp
Termination Style
Screw Terminals
Dimensions
L:79.9mm x W:45mm x D:40.3mm
Unit Weight
296g
Factory Pack Qty
20
Datasheet
HS501DR
MCBC Series
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
84874320 Crouzet C-Lynx Speed Monitoring/Control Relay With SPDT Contacts, 24 - 240 V AC/DC
Pick up this Crouzet HSV Control/Speed Monitoring Relay from the team at Fastron Electronics. Capable of controlling overspeed, operating rate, underspeed, and stopping, this is an industry-leading speed monitoring relay component.
Compatible with either NC or NO sensors, this monitoring/control relay also features adjustable energy monitoring capabilities.
For more information about this product, explore the description, specification and datasheet on this page. Alternatively, the Fastron Electronics team is always happy to assist you with all your technical support requirements. With more than 40 years of experience in energy monitoring and energy management, we are proud to offer the highest quality products, with free shipping available on all purchases over $300AUD.
Looking for an alternative product? Contact Fastron Electronics today to enquire about availability and pricing information. We would be more than happy to help you with your custom project.
Crouzet HSV Speed Monitoring/Control Relay With SP-NO/NC Contacts
DIN Rail Mount 35 mm HSV Part number 84874320 :
Control of overspeed, underspeed, operating rate, stopping
Measurement via discrete sensors - 3-wire PNP or NPN, Namur, voltage 0-30V or volt-free contact type
Works with either NO or NC sensors
Time between pulses adjustable from 0.05 s to 10 min.
Power-on inhibit time, adjustable from 0.6 to 60 s Inhibit time can be managed via an external contact
Specification
Crouzet Part Number
84874320 (Single Phase C-Lynx Speed Monitoring Relay With SPDT Contacts)
Function
Speed Control
Nominal Voltage
24 → 240 V AC/DC
Frequency of Measured Signal
1.5 m Hz minimum, 22 Hz maximum
Measurement Ranges
0,5 s - 1 s - 5 s - 10 s - 1 mn - 5 mn - 10 mn
Digital Output
1 x C/O Relays, 250VAC/DC @ 5 Amp
Min Breaking Current
10mA/5VDC
Inhibit Delay Timing Range
0.6 → 60s (0, +10% of full scale)
Delay on Pickup
50ms
Threshold Crossing Response
15ms
Reset Time (Memory Mode)
50ms
Reset Time (Power Break)
1500ms
Isolation
4kV
Repetition Accuracy
0.5%
Threshold Adjustment Range
10 → 100 % of the range
Termination Style
Screw
Weight
170g
Certification
UL, CSA, ROHS
Factory Pack Qty
1
Over Voltage Category
3 in accordance with IEC/EN 60664-1
Pollution Degree
2 in accordance with IEC/EN 61131-2
Protection rating
IP40 (Front), IP20 (Rear)
Mechanical Resistance
Immunity to vibrations IEC/EN 60068-2-6, test Fc
Immunity to shock IEC/EN 60068-2-27, test Ea
Resistance to HF Interference
Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12
Conducted and radiated emissions
Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure)
Operating Temperature
-20 →+70 °C except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-22
Datasheet
Product Datasheet
GFIN/100M-DR + PMP4850WP, DIN Mount, Proportional Controller, 380-480VAC 50 Amp @ 40 Deg C, Selection for Burst/Phase Angle, 4-20mA, 0-10V, 0-5V Input, Din Rail Mount, with Overvoltage Protection
Selectable Proportional Phase or Burst Control Input
Ratings from 25A to 90 Amp @ 170-600 VAC
SCR output for heavy industrial loads
Zero voltage or Instantaneous turn-on outputs
UL/CE/ROHS Compliant
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Specification
Crydom Part Number
GFIN/100M-DR + PMP4850WP
Switching Type
Phase Angle or Burst (Selectable)
ROHS/CE/UL
Yes
Control Voltage
0 - 10V/0 - 5V/4 - 20mA Proportional Input (Selectable)
Note Requires DC Power Supply for 0-5V/0-10V input modes
Load Current
50 Amp (rms)
Surge Capability
597 Amp (peak)
Special Feature
Proportional Controller + SSR + Overvvoltage Protection
Mounting Style
Panel Mount
Load Voltage Range
345-530VAC
Dielectric Strength
4kV
Termination Style
Terminal Plug
Unit Weight
1000g
Factory Pack Qty
20
Datasheet
PMP24 Series Datasheet
PMP24 Installation/Wiring Guide
GFIN
Equivalent Parts
Contact Us for Possible Replacement
Fastron Electronics AMB-D-V6-D-N, 96x48mm DC Voltmeter, Panel Mount, 0-300V DC Input, 24-60VDC supply, Previously AMB-D-V6-24VDC, Large 4.1 Digit
Adjustable Zero and Span Setting
Adjustable Display Scaling
Large 4.1 Digit 20.3mm (8 Inch) LED Display
250mS Response Time
PC 94 UL V0
Each unit needs just 96 x 48mm Panel Space
90mm Depth
CE Approved
Specification
Fastron Electronics Part Number
AMB-D-V6-D-N
Conditioner Output
N/A
Input
300VDC
Over Range
x 1.5
Operating Temperature
0 - 60°C
Supply Voltage
22-60VDC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Display Type
4.1 Digit RED LED
Mounting Style
96 x 48mm Panel Mount
Case Material
PC - UL 94 V0
Weight
320g
Factory Pack Qty
1
Datasheet
Product Datasheet
Application Notes
Panel Meters Blog Articles
Fastron Electronics GBMA-4-DVO(0-150VDC)-ANNN, 140x420mm Digital Voltmeter, Panel Mount, 0-150V DC Input, 100-240VAC/DC supply, with IR Remote Control
Adjustable Zero and Span Setting
Adjustable Display Scaling
Remote Control Included
Wall Mount
LED Tile Display
Large 4 Digit 100mm (40 Inch) LED Display
250mS Response Time
PC 94 UL V0
100mm Depth
CE Approved
Specification
Fastron Electronics Part Number
GBMA-4-DVO(0-150VDC)-ANNN
Conditioner Output
N/A
Input
0-150VDC
Over Range
x 1.5
Operating Temperature
0 - 60°C
Supply Voltage
100-240VAC/DC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
140 x 420 mm Wall Mount
Case Material
PC - UL 94 V0
Weight
3.6kg
Factory Pack Qty
1
Datasheet
Product Datasheet
Application Notes
Panel Meters Blog Articles
Crydom D5D07, Solid State Relay, DC 3-32VDC control, 7A, 500VDC Load
Features
Ratings from 7A to 100 Amp @ 100-500VDC
Mosfet output for reliable DC switching
Multiple modules can be wired in parallel for higher currents
UL/CSA/VDE Approved, CE Compliant to EN60950-1
Improved SEMS screw and washer
Redesigned housing with anti-rotation barriers
Direct bond copper substrate
EMC compliant to Level 3
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
D5D07
Switching Type
DC Load
ROHS
Yes (Details)
Control Voltage
3.5-32VDC
Load Current
7 Amp DC
Surge Capability (10ms)
19 Amp DC
Special Feature
None
Mounting Style
Panel Mount
Load Voltage Range
0 - 500VDC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
75g
Factory Pack Qty
20
Datasheet
Product Datasheet
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
Equivalent
Contact Us for Possible Replacement
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
BH-50-1-24, Split Core Hall Effect DC Current Transducer, +/-50 Amp DC, +/-10V Bipolar output, 31mm aperture, 24VDC supply
Compact and versatile Split Core DC current sensor, +/-50 Amp DC, +/-10VDC Bipolar or 0-10V Bipolar Analogue Output
Features
⌀31mm Aperture
Split Core
DC Bipolar or Bipolar Measurement
+/-10V analogue output
Busbar, or DIN Rail Mounting
Isolated plastic case recognised according to UL94-V0
Advantages
High isolation between primary and secondary circuits
Easy installation
DIN Rail Mount
Applications
-Automation Systems
Analogue current reading for remote monitoring (e.g. Motor)
-Data Loggers
Self Powered. Will not drain data logger batteries
-Panel Meters
Simple connection displays power consumption
Specification
Fastron Part Number
BH-50-1-24
Technology
DC Hall Effect Current Transducer with Process Output
ROHS
Yes
Supply Voltage
24VDC
Nominal Current (DC)
+/-50 Amp DC
Response Time
< 200mS
Output
Bipolar 0-10V, or Bipolar +/-10VDC Analogue
Isolation
2.5kV (AC, 50Hz, 1 min)
Bandwidth
DC
Mounting Style
DIN Rail Mount
Operating Temperature Range
-40°C / 85°C
Accuracy
1%
Termination Style
Elevator Screw
Unit Weight
120g
Factory Pack Qty
6
Datasheet
Product Datasheet
Eastron Europe DCM230 1-1-1-1 V2, DIN Rail Mount DC kWh Meter, 1000VDC, 85-265VAC aux, Class 1, 45/60/75mV Shunt Connect, w/ 1 x pulse outputs and RS485 Modbus RTU Comms, Single Tariff, MID Approved
45/60/75mV Shunt Connect
RS 485 communication up to 38,400 bit/s as standard
1 x Pulse Outputs (1 Configurable)
Bidirectional Measurement
The meter is intended for measuring, and monitoring single-phase or electrical power network. The meter records DC Current and Voltage (DC Power) value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, energy, power) from the measured signals.
Features :
Accuracy class 1
Measurement of Active and Reactive Power
Modbus RTU communication up to 38,400 bit/s communication
Pulse output as standard
Graphic LCD with illumination
Specification
Eastron Europe Part Number
DCM230 1-1-1-1 V2
Functions
DC Energy Meter
Supply Voltage
85-265VAC
Nominal Measurement Range
5-300VDC,5-600VDC,5-1000VDC (See version 1
Maximum Measurement Range
5-1000VDC
Nominal Current Input
Shunt up to 2000Amp See our DC Current Shunt Section for Suitable Shunt
Pulse Output
1 x Configurable 60/100/200ms
Tariff Input
N/A
Accuracy
Class 1 (I,U,kW,kWh)
Mounting
Din Rail
Real Time Clock
1min/month (30ppm)
Internal Memory
N/A
Dimensions
36mm x 100mm x 66mm (2 modules wide)
Isolation
4kV
RS485
2400-38400 b/s
Weight
250g
Certification
EN 61010-1 Installation Category III
Factory Pack Qty
1
Safety
IP51(Indoor)
Enclosure Material
Noryl with fire protection to UL94-V-O. Self extinguishing
Enclosure Size
DIN 42880 4 Modules
Operating Temperature
-20 →+70 °C
Documents
Product Datasheet
User Manual
Modbus Utility
EEM Meter Setting Software Utility
Fastron FRI 8-01/0.05, Current Monitoring Relay AC 0.05 - 0.5 A, Adjustable delay 0.5 - 10 s, 1 x CO 10 Amp, Universal 24-240VAC 24VDC Aux Supply
FRI 8 Series serves to monitor AC currents up to 16 Amp, and provides Relay alarm output with adjustable delay time 0.5 - 10s.
Features :
Suitable for Current Transformer Monitoring
Flexible adjustment by potentiometer, choise of
6 Models: 0.05 - 0.5 A; 0.1 - 1 A; 0.2 - 2 A; 0.5 - 5 A; 0.8 - 8 A; 1.6 - 16 A Adjustable delay 0.5 - 10 s to eliminate short current peaks
Possible to use current scanning from current transformer - up to 600 A Universal supply AC 24 - 240 V and DC 24 V
Supply is galvanically separated from measured current
Output contact: 1 x changeover 8 A
1-phase, 1-MODULE, DIN rail mounting
Applications :
Heating bars in sliding rails
Heating cables
Indication of current flow
Controlling of 1-phase motor consumption
Specification
Fastron Part Number
FRI 8-01/1
Voltage Range
AC 24 - 240 V, DC 24 V (AC 50 - 60 Hz)
Operating Range
-15 %; ? %
Current Range
0.05 - 0.5 A (AC 50 Hz)
Current Trip Adjustment
Potentiometer
Setting Accuracy
5 %
Burden
max. 1.5 VA
Repeatability
1 %
Temperature Drift
0.1%/??C
Peak Overload (10s)
1.1 x Ipn
Time delay T1
max. 500 ms
Time delay T2
adjustable 0.1-10 s
Output
??
Number of contacts
1x changeover/ SPDT (AgNi / Silver Alloy)
Rating
10 A / AC1
Breaking capacity
2500 VA / AC1, 240 W / DC
Inrush current
10 A
Switching voltage
250 V AC1 / 24 V DC
Min. breaking capacity DC
500 mW
Indication of state
red LED
Mechanical life
1 x 107
Electrical life (AC1)
1 x 105
Other information
??
Operating temperature
-20 ... ? ??C
Storage temperature
-30 ... ? ??C
Electrical strength
4 kV (supply - output)
Operating position
any
Mounting
DIN rail EN 60715
Protection degree
IP 40 from front panel / IP 10 terminals
Overvoltage cathegory
III.
Pollution degree
2
Max. cable size (mm )2
solid wire max. 2x2.5 or 1x4 ; with sleeve max. 1x2.5 or 2x1.5
Dimensions
90 x 17,6 x 64 mm
Weight
69 g
Standards
EN 60255-6, EN 61010-1, RoHS
Datasheet
Product Datasheet
Application Notes
Monitoring relay FRI serves to monitor current level in single phase AC circuits. Due to its fluent adjustment of release current, it is predestined for applications with necessity of current flow indication, and can be used as precedence relay. Output relay is off in normal state. In case the set current level is exceeded, it switches. Multivoltage supply is an advantage.
Crouzet GN Series 84137870, SSR DC 4-32VDC control, 30A, 50VDC Load, with LED Indicator and IP20 Cover
Features
Ratings from 7A to 100 Amp @ 100-500VDC
Mosfet output for reliable DC switching
Multiple modules can be wired in parallel for higher currents
UL/CSA/VDE Approved, CE Compliant to EN60950-1
Improved SEMS screw and washer
Redesigned housing with anti-rotation barriers
Direct bond copper substrate
EMC compliant to Level 3
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
84137870
Switching Type
DC Load
ROHS
Yes (Details)
Control Voltage
4-32VDC
Load Current
30 Amp DC
Surge Capability (10ms)
75 Amp DC
Special Feature
LED status Indicator and KS101 IP cover
Mounting Style
Panel Mount
Load Voltage Range
0 - 50VDC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
75g
Factory Pack Qty
20
Datasheet
Product Datasheet
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
Equivalent
See alternative D1D40K with raised terminals for alternative or D1D80 for higher current alternative. Note both have no IP20 cover, or LED indicator. KS101 IP cover can be purchased here.
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies