Crydom HS151DR-D5D10, Din Rail Mount DC Solid State Relay, with Heatsink 3-32VDC control, 8.2A @ 40 Deg C, 500VDC Load
Features
Ratings from 7A to 100 Amp @ 1-500VDC
Mosfet output for equal load sharing
Zero voltage or instantaneous turn-on outputs
UL/CE/ROHS Compliant
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Spec
Part Number
HS151DR + D5D10
Switching Type
DC Switching
ROHS/CE/UL
Yes
Control Voltage
3.5 - 32VDC
Load Current
8.2 Amp DC @ 40 Deg C
Surge Capability
29 Amp DC
Special Feature
LED Status Indicator
Mounting Style
Panel Mount
Reccomended Load Voltage
1-385 VDC
Max Load Voltage
500 VDC
Termination Style
Screw Terminals
Dimensions
L:97mm x W:45mm x D:142.8mm
Unit Weight
450g
Factory Pack Qty
10
Datasheet
HS151DR Datasheet
Series 1 DC
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Rish Xmer Split Core 3000/5 Amp 195/80 Class 0.5, 30VA Series Current Transformer, 85 x 172mm Aperture
Features
Quick Release Split Core System
Built In Sealable Terminal Covers
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Electronics Part Number
Rish Xmer Split Core 3000/5 195/80
Technology
Split Core AC Current Transformer
Ratio
3000/5
Aperture Size
172 x 85mm
VA Rating
45VA
Accuracy Class
Class 1
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-25°C / 40°C
Continuous Current (max)
Ipn x 1.2
Termination Style
Screw
Unit Weight
2kg
Factory Pack Qty
9
Datasheet
Product Datasheet
Fastron Electronics FGC1-F150-230VAC, AC Contactor, 240VAC Control Voltage, 3 Pole NO, Nominal Current = 150 Amps(AC-3) @ 240/400/500/690V
Contactors are designed to meet the requirements of heavy Duty applications. Contactors may be fitted with auxiliary contacts. Peak current is limited to the value within the contactor making capacity.
Features :
High contact reliability at low voltages
High electrical and mechanical endurance and high switching capacity
Four and Three-pole contactors
Optional auxiliary contacts
Ratings from 6 Amp to 1000 Amp
CE, CB Approved
Advantages :
Saves costs of expensive replacement
Long electrical life
Reduces watt losses during “ON” condition, saves energy
High safety
No risk of dangerous voltage
Less maintenance and downtime
Standard control voltages: 24 V 50/60 Hz, 240 V 50/60 Hz, 415 V 50/60 Hz
Specification
Fastron Electronics Part Number
FGC1-F150-230VAC
Functions
3 Pole Contactor
Nominal Voltage
230/400/500/690VAC @ 50/60Hz
Current Carrying Capacity as per UL
150 Amp Continuous @ 55 Deg C
Main Contacts
3 x NO
Aux Contacts
None
Trip Delay Time
2-10ms
Electrical Life
1,000,000 Ops
Operating Temperature
-25 to 55 Deg C
Mechanical Operations
6,000,000 Ops
Control Voltage
240VAC
Pole Resistance (avg)
0.35m Ohm
Approvals
CE, CB, TUV, LVD
Standards
IEC/EN 60947-4-1, AS/NZ 61009-1
Weight
1.8kg
Enclosure Material
UL94
Factory Pack Qty
1
Datasheet
Product Datasheet
FTH2553ZD3 + HS212, Solid State Relay, and Heatsink Assembly, 3 Phase 4-32VDC Control, 20 Amp per phase @ 40 Deg C, 48-530VAC Load, LED Status Indicator, with IP20 Cover
Features
Ratings from 25A to 50 Amp @ 70-530 VAC
SCR output for heavy industrial loads
Zero voltage or Instantaneous turn-on outputs
UL/CE/ROHS Approved
IP20 Cover Available
AC & DC control types
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Spec
Fastron Part Number
FTH2553ZD3 + HS212DR
Switching Type
Zero Crossing
ROHS/CE/UL
Yes
Control Voltage
4-32VDC
Load Current
3 x 20 Amp (rms) per Phase
Surge Capability
350 Amp (peak)
Special Feature
LED Status Indicator, with IP20 Cover
Mounting Style
Panel Mount
Load Voltage Range
48-530VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
315g
Factory Pack Qty
10
Datasheet
HS212 Datasheet
D53TP Series
3 Phase SSR and Heatsink Mounted
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Fastron Electronics FESCT-075-1200-5-IP65, 1200Amp measurement Split Core CT's, Class 1, 10VA, w/10M Flying leads, ø 75mm Aperture
Features
Quick Release Split Core System
10m Flying Leads
ø 75mm
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.60/3kV
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Electronics Part Number
FESCT-075-1200-5-IP65
Technology
Split Core AC Current Transformer
Ratio
1200/5A
Aperture Size
ø 75mm
VA Rating
10VA
Accuracy Class
Class 1
Output
5 Amp (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Dimensions
180x138x52mm
Mounting Style
Panel Mount
Operating Temperature Range
-35°C / 55°C
Continuous Current (max)
1200Amp x 1.2
Termination Style
10M Twisted Pair 0.34mm^2
Unit Weight
2000g
Factory Pack Qty
9
Datasheet
Product Datasheet
Application Notes
Installation Guide
Rotating Diode for Generators, MSD306R24UB, 3/8" Top Stud, 3/4" Bottom Stud, Cathode Stud
User for Rotating Generator or Motor Applications
310 Amp Rating
Datasheet
Product Datasheet
Crydom HS211 + D2450-10, Panel or slide on Din Rail Solid State Relay 3-32VDC Control Input, LED Status, Random Cross, 24-280VAC Output, 25 Amps
Features
Ratings from 25A to 125 Amp @24-280 VAC
SCR output for heavy industrial loads
Zero voltage or instantaneous turn-on outputs
UL/CE/ROHS Compliant
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Panel Mount
Din Rail Mount
Spec
Part Number
HS211 + D2450-10
Switching Type
Random Crossing
ROHS/CE/UL
Yes
Control Voltage
3-32VDC
Load Current
25 Amp (rms) @ 40 Deg C
Surge Capability
597 Amp (peak)
Special Feature
N/A
Mounting Style
Panel Mount
Load Voltage Range
24-280VAC
Max Non Repetitive Peak Voltage
600 Vp
Termination Style
Screw Terminals
Dimensions
L:81mm x W:45mm x D:73.4mm
Unit Weight
296g
Factory Pack Qty
20
Datasheet
HS211
D2450-10
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Fastron Electronics FESCT-075-1000-5-IP65, 1000Amp Measurement, 5 Amp Output Split Core CT's, Class 1, 7.5VA, w/10M Flying leads, ø 75mm Aperture
Features
Quick Release Split Core System
10m Flying Leads
ø 75mm
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.60/3kV
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurement, 5 Amp Outputs
Specification
Fastron Electronics Part Number
FESCT-075-1000-5-IP65
Technology
Split Core AC Current Transformer
Ratio
1000/5A
Aperture Size
ø 75mm
VA Rating
7.5VA
Accuracy Class
Class 1
Output
5 Amp (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Dimensions
180x138x52mm
Mounting Style
Panel Mount
Operating Temperature Range
-35°C / 55°C
Continuous Current (max)
1000Amp x 1.2
Termination Style
10M Twisted Pair 0.34mm^2
Unit Weight
2000g
Factory Pack Qty
9
Datasheet
Product Datasheet
Application Notes
Installation Guide
Fastron H31/110M + FTH2553ZD3, 3 Phase Solid State Relay, with Heatsink, IP20 Cover, Panel Mount, 25 Amps Per Phase @ 50 Deg C, 530VAC Load, with IP20 Cover
Ratings from 25 to 120 Amp @ 70-480 VAC
SCR output for heavy industrial loads
Zero voltage or Instantaneous turn-on outputs
IP20 Cover Included
AC & DC control types
Direct bond copper substrate
Direct power lead frame
Includes IP20 Cover
Specification
Fastron Part Number
H31/110M + FTH2553ZD3
Switching Type
Zero Crossing
ROHS/CE/UL
Yes
Control Voltage
3-32VDC
Load Current
3 x 25 Amp (rms) @ 50 Deg C
Surge Capability
350 Amp (peak)
Special Feature
LED Status Indicator, with IP20 Cover
Mounting Style
Panel Mount
Load Voltage Range
70-530VAC
Dimensions
L:110 x W:125 x D:180mm
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
2kg
Factory Pack Qty
10
Datasheet
Product Datasheet
H31 Datasheet
Equivalent Parts
Contact Us for Possible Replacement
Magnelab MCT-0016-010, 10 Amp, Loop Powered AC Current Transducer, Average RMS, 4-20mA Output, Accuracy +/-2% (Ripple)
Features
Average RMS Output
Split Core
4-20mA Current Output
Cable Mounting
20-30VDC Loop Powered
Isolated plastic case recognised according to UL94-V0
UL, CE, ROHS Approved
Advantages
Large aperture for cable up to ⌀ 24mm
High isolation between primary and secondary circuits
Easy installation
Applications
Current Measurement
Energy Management
Motor Control
Actuators
Lamp Failure
Specification
Magnelab Part Number
MCT-0016-010
Technology
AC Current Transducer
Protection Class
IP50
Supply Voltage
20-30VDC Loop Powered (10mA)
Load Current (RMS)
10 Amp
Output
4-20mA (Average RMS)
Isolation
3.5kV (AC, 50Hz, 1 min)
Bandwidth
50 - 60Hz
Mounting Style
Din Rail Mount
Operating Temperature Range
-10°C / 65°C
Accuracy
+/-2% Ripple on output
Termination Style
Screw
Aperture
16mm
Approvals
UL, CE, ROHS
Unit Weight
170g
Factory Pack Qty
6
Datasheet
Product Datasheet
F930 Series Programmable True RMS AC or DC Versions, Various Ranges 100mA - 250 Amp AC/DC Current Transducer with 4 Digit LED Display, Selectable Process Level Outputs, Optional RS485 and/or 2 x Relay Outputs
Features
Following on from the success of F916,F921,F920,F922,,F923 Series AC/DC Current Transducers & Trip Modules. We designed a new microcontroller based transducer to take advantage of modern digital methods and the latest generation of LEM ASIC based current sensors. Our transducer can adjust zero, span, and optional Alarms, including dual flasher outputs in both Traditional Relay or Solid State types. Ultimately, there will also be a Power Transducer with one or two analogue outputs & RS485 Comms for import export control applications. Our Transducers are widely used in rail and several other industrial control and automation industries.
Datasheet
Product Datasheet
Crydom DR06D12, Solid State Relay, 4-32VDC control, 12 Amp 1-60VDC Output, Slimline, Din Rail Mount, LED status Indicator
Features
Ratings from 3 Amp, 1-100VDC, 1-60VDC, 24-280VAC, 48-600VAC
DIN Rail Mount
SCR output for reliable AC switching, or Mosfet for DC Switching
Ultra slim package
UL/CSA/VDE Approved, CE Compliant to EN60950-1
EMC compliant to Level 3
Epoxy free design
Spec
Crydom Part Number
DR06D12
Switching Type
DC
ROHS
Yes (Details)
Control Voltage
4-32VDC
Load Current
12 Amp (rms)
Surge Capability (10ms)
60 Amp (peak)
Special Feature
LED Status Indicator
Mounting Style
DIN Rail Mount
Load Voltage Range
1-60VDC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
38g
Factory Pack Qty
20
Datasheet
Product Datasheet
Equivalent
DRA1-CMX60D10
ED06C5
ED06D5
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies