Crydom HS501DR + D5D10, Din Rail Mount DC Solid State Relay, with Heatsink 3-32VDC control, 4.6A @ 40 Deg C, 500VDC Load
Features
Ratings from 7 to 100 Amp @1-500VDC
SCR output
Zero voltage or instantaneous turn-on outputs
UL/CE/ROHS Compliant
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Spec
Part Number
HS501DR + D5D10
Switching Type
DC Switching
ROHS/CE/UL
Yes
Control Voltage
3.5-32VDC
Load Current
4.6 Amp (rms) @ 40 Deg C
Surge Capability
29 Amp (peak)
Special Feature
N/A
Mounting Style
Din Rail or Panel Mount
Recommended Voltage Range
1-385VDC
Max DC Voltage
500V
Termination Style
Screw Terminals
Dimensions
L:79.9mm x W:45mm x D:40.3mm
Unit Weight
296g
Factory Pack Qty
20
Datasheet
HS501DR
Series 1 DC
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
D53TP50D + HS212, Solid State Relay, and Heatsink Assembly, 3 Phase 4-32VDC Control, 20 Amp per phase @ 40 Deg C, 48-530VAC Load, LED Status Indicator
Features
Ratings from 25A to 50 Amp @ 70-530 VAC
SCR output for heavy industrial loads
Zero voltage or Instantaneous turn-on outputs
UL/CE/ROHS Approved
IP20 Cover Available
AC & DC control types
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
D53TP50D + HS212DR
Switching Type
Zero Crossing
ROHS/CE/UL
Yes
Control Voltage
4-32VDC
Load Current
3 x 20 Amp (rms) per Phase
Surge Capability
597 Amp (peak)
Special Feature
LED Status Indicator
Mounting Style
Panel Mount
Load Voltage Range
48-530VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
315g
Factory Pack Qty
10
Datasheet
D53TP Series
3 Phase SSR and Heatsink Mounted
HS212 Datasheet
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Crydom DR2260D20V, Solid State Contactor SSR, Single Phase 4-32VDC Control, 20A, 48-600VAC Load, Din Rail Mount w/status LED
Features
Ratings from 20 Amp up to 30 Amp @ 200 VDC
Mosfet output for heavy industrial loads
UL/CSA/VDE Approved, CE Compliant to EN60950-1
Din Rail Mount with bonded Heat sink
Direct bond copper substrate
EMC compliant to Level 3
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
DR2260D20V
Switching Type
DC Load
ROHS
Yes (Details)
Control Voltage
4 - 32VDC
Load Current (single unit)
20 Amp (rms) @ 45 Deg C Ambient, 18 Amp (rms) @ 50 Deg C Ambient
Load Current (multiple units)
16.5 Amp (rms) @ 40 Deg C Ambient, 13 Amp (rms) @ 50 Deg C Ambient
Surge Capability
286 Amp RMS
Special Feature
None
Mounting Style
DIN Rail Mount
Load Voltage Range
48 - 600VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
298g
Factory Pack Qty
20
Datasheet
Product Datasheet
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Crydom H12D4840DE, Dual Solid State Relay, Two Pole 15-32VDC Control, 2 x 40A, 48-530VAC Load
Features
Ratings from 2 x 25A to 2 x 40 Amp @ 48-480VAC
SCR output for heavy industrial loads
Zero voltage or instantaneous turn-on outputs
UL/CSA/VDE Approved, CE Compliant to EN60950-1
Improved SEMS screw and washer
Redesigned housing with anti-rotation barriers
AC & DC control types
Direct bond copper substrate
EMC compliant to Level 3
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
H12D4840DE
Switching Type
Zero Crossing (Dual)
ROHS
Yes (Details)
Control Voltage
15-32VDC
Load Current
2 x 40 Amp (rms)
Surge Capability
597 Amp (peak)
Special Feature
Dual SSR, 1200V Transient Withstand
Mounting Style
Panel Mount
Load Voltage Range
48-530VAC
EMC Compliant
Level 3
Termination Style
faston
Unit Weight
89g
Factory Pack Qty
20
Datasheet
Product Datasheet
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
Equivalent
See CC4850W3VH
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Crydom DR2260D35V, Solid State Contactor SSR, Single Phase 4-32VDC Control, 35A, 48-600VAC Load, Din Rail Mount
Features
Ratings from 20A to 35 Amp @ 48-660 VAC
Contactor Style for retrofit
SCR output for heavy industrial loads
Zero voltage or instantaneous turn-on outputs
UL/CSA/VDE Approved, CE Compliant to EN60950-1
Improved SEMS screw and washer
Redesigned housing with anti-rotation barriers
AC & DC control types
Direct bond copper substrate
EMC compliant to Level 3
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
DR2260D35V
Switching Type
Zero Crossing
ROHS
Yes (Details)
Control Voltage
4 - 32VDC
Load Current (single unit)
35 Amp (rms) @ 40 Deg C Ambient, 30 Amp (rms) @ 50 Deg C Ambient
Load Current (multiple units)
25 Amp (rms) @ 40 Deg C Ambient, 20 Amp (rms) @ 50 Deg C Ambient
Surge Capability
1290 Amp (peak)
Special Feature
Contactor Style Terminals
Mounting Style
DIN Rail Mount
Load Voltage Range
48 - 660VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
298g
Factory Pack Qty
20
Datasheet
Product Datasheet
Alternatives
SSR Style CKRD4830
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Crydom HS211 + HD4850, Panel or slide on Din Rail Solid State Relay, 3-32VDC Control Input, 90-530VAC Output, 25 Amps
Features
Ratings from 25A to 125 Amp @48-530 VAC
SCR output for heavy industrial loads
Zero voltage or instantaneous turn-on outputs
UL/CE/ROHS Compliant
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Panel Mount
Din Rail Mount
Spec
Part Number
HS211 + HD4850
Switching Type
Zero Crossing
ROHS/CE/UL
Yes
Control Voltage
3-32VDC
Load Current
23 Amp (rms) @ 40 Deg C
Surge Capability
597 Amp (peak)
Special Feature
N/A
Mounting Style
Din Rail or Panel Mount
Load Voltage Range
48-530VAC
Max Non Repetitive Peak Voltage
600 Vp
Termination Style
Screw Terminals
Dimensions
L:81mm x W:45mm x D:73.4mm
Unit Weight
296g
Factory Pack Qty
20
Datasheet
HS211
HD4850
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Crydom HS501DR + D1D20, Din Rail Mount DC Solid State Relay, with Heatsink 3-32VDC control, 13A @ 40 Deg C, 100VDC Load
Features
Ratings from 7 to 100 Amp @1-500VDC
Mosfet output for equal load sharing
Zero voltage or instantaneous turn-on outputs
UL/CE/ROHS Compliant
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Spec
Part Number
HS501DR + D1D20
Switching Type
DC Switching
ROHS/CE/UL
Yes
Control Voltage
3.5-32VDC
Load Current
13 Amp DC @ 40 Deg C
Surge Capability
42 Amp DC
Special Feature
N/A
Mounting Style
Din Rail or Panel Mount
Recommended Voltage Range
1-72VDC
Max DC Voltage
100VDC
Termination Style
Screw Terminals
Dimensions
L:79.9mm x W:45mm x D:40.3mm
Unit Weight
296g
Factory Pack Qty
20
Datasheet
HS501DR
Series 1 DC
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Crydom HS501DR + D5D07, Din Rail Mount DC Solid State Relay, with Heatsink 3-32VDC control, 4.5A @ 40 Deg C, 500VDC Load
Features
Ratings from 7 to 100 Amp @1-500VDC
Mosfet output for equal load sharing
Zero voltage or instantaneous turn-on outputs
UL/CE/ROHS Compliant
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Spec
Part Number
HS501DR + D5D07
Switching Type
DC Switching
ROHS/CE/UL
Yes
Control Voltage
3.5-32VDC
Load Current
4.5 Amp (rms) @ 40 Deg C
Surge Capability
19 Amp (peak)
Special Feature
N/A
Mounting Style
Din Rail or Panel Mount
Recommended Voltage Range
1-385VDC
Max DC Voltage
500VDC
Termination Style
Screw Terminals
Dimensions
L:79.9mm x W:45mm x D:40.3mm
Unit Weight
296g
Factory Pack Qty
20
Datasheet
HS501DR
DC60 Series
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
A53TP50D + HS212DR-F, Solid State Relay, and Heatsink Assembly, 3 Phase 90-280VAC Control, 36 Amp per phase @ 40 Deg C, 48-530VAC Load, LED Status Indicator
Features
Ratings from 25A to 50 Amp @ 70-530 VAC
SCR output for heavy industrial loads
Zero voltage or Instantaneous turn-on outputs
UL/CE/ROHS Approved
IP20 Cover Available
AC & DC control types
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
D53TP50D + HS212DR-F
Switching Type
Zero Crossing
ROHS/CE/UL
Yes
Control Voltage
90-280VAC
Load Current
3 x 36 Amp (rms) per Phase
Surge Capability
597 Amp (peak)
Special Feature
LED Status Indicator
Mounting Style
Din Rail Mount
Load Voltage Range
48-530VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
315g
Factory Pack Qty
10
Datasheet
D53TP Series
3 Phase SSR and Heatsink Mounted
HS212 Datasheet
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Crydom HS201DR + A4850, Din Rail Mount Solid State Relay, 90-280VAC Control Input, 90-530VAC Output, 28 Amps, Solid State Relays + Heatsink
Features
Ratings from 25A to 125 Amp @ 48-530 VAC
SCR output for heavy industrial loads
Zero voltage or instantaneous turn-on outputs
UL/CE/ROHS Compliant
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Spec
Part Number
HS201DR + A4850
Switching Type
Zero Crossing
ROHS/CE/UL
Yes
Control Voltage
90-280VAC
Load Current
28 Amp (rms) @ 40 Deg C
Surge Capability
630Amp (peak)
Special Feature
N/A
Mounting Style
Panel Mount
Load Voltage Range
48-530VAC
Max Non Repetitive Peak Voltage
600 Vp
Termination Style
Screw Terminals
Dimensions
L:81mm x W:45mm x D:115mm
Unit Weight
415g
Factory Pack Qty
20
Datasheets
HS201DR
HA4850
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
HS212DR, Heatsink 110mm, Milled, Drilled and Tapped for 3 Phase & Single Phase SSR, 1°C/W
Specifications
Suitable for 3 x 20 Amp rms output @ 40 Deg C
Panel Mount
Datasheet
Product Datasheet
Heatsink products are mostly made to order and require 2-3 days more to produce.
Crydom D1D80, 3-32VDC Input, 100V, 80Amp DC Output Solid State Relay
Features
Ratings from 7A to 100 Amp @ 100-500VDC
Mosfet output for reliable DC switching
Multiple modules can be wired in parallel for higher currents
UL/CSA/VDE Approved, CE Compliant to EN60950-1
Improved SEMS screw and washer
Redesigned housing with anti-rotation barriers
Direct bond copper substrate
EMC compliant to Level 3
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
D1D80
Switching Type
DC Load
ROHS
Yes (Details)
Control Voltage
3.5-32VDC
Load Current
80 Amp DC
Surge Capability (10ms)
220 Amp DC
Special Feature
None
Mounting Style
Panel Mount
Load Voltage Range
0 - 100VDC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
75g
Factory Pack Qty
20
Datasheet
Product Datasheet
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies