Fastron Electronics SCT-F24-250 250/5 Amp Class 1 Series Current Transformer
Features
Quick Release Split Core System
Cable Mount
5 Amp Output
Self Powered
Rated System Voltage 0.60/3kV
0.9M Flying Leads
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
SCT-F24-250-5A
Technology
Split Core AC Current Transformer
Ratio
250/5 Amp
Aperture Size
ø 24 mm
VA Rating
N/A
Accuracy Class
Class 1
Output
5 Amp (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
250Amp x 1.2
Termination Style
0.9M Flying leads
Unit Weight
100g
Factory Pack Qty
9
Datasheet
Product Datasheet
Application Notes
Installation Guide
Fastron Electronics BTCD/A-M1-A2-EI, PID Controller 96x96mm, 15-50VDC, 4-20mA output, 2 Alarms, Retransmission, Multirange TC/RTD/4-20mA Input
4-digit displays suit most industries including Temperature, Humidity, Pressure (0.5s response)
Drip-proof / Dust-proof IP56 (front panel only)
CE Approved
Each unit needs just 80 mm depth panel space
Optional Pattern Control Feature
Specification
Fastron Part Number
BTCD/A-M1-A2-EI
Control Output
4-20mA
Input
Multirange 4-20mA/RTD/Thermocouple (other linear inputs to be specified at time of order)
Option 1
2nd Alarm
Option 2
Event Input (2 x SV), 4-20mA Retransmission
Mounting Style
96 x 96mm Panel Mount
Load Voltage Range
15-50VDC
Termination Style
Screw
Weight
600g
Factory Pack Qty
1
CE
Yes
Datasheet
BTC Series Brochure
BTC Series User Manual
BTC Series RS485 Comms Manual
Fine Tuning PID Adjustments
Fastron Electronics GAT-D-A Multirange Input/Output Signal Conditioner or Transmitter
Adjustable Zero and Span Setting
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space
Specification
Fastron Electronics Part Number
GAT-D-A
Control Output (Multirange)
0-5V,0-10V,0-10mA,0-20mA,4-20mA
Input (Mutirange)
0-50mV,0-5V,1-5V,0-10V,0-1mA,0-20mA,4-20mA
Over Range
x 1.5
Operating Temperature
0 - 60°C
Load Voltage
90 - 280VAC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
DIN Rail Mount
Case Material
PC - UL 94 V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
Fastron Electronics BTCR/R-M1-A2-DS-C5, PID Controller 48x96mm, 15-50VDC, Relay Output 2 Alarms, SSR Cooling, RS485 Modbus Comms, Multirange TC/RTD/4-20mA Input
4-digit displays suit most industries including Temperature, Humidity, Pressure (0.5s response)
Dust-proof IP56 (front panel only)
Optional 32-step pattern (for SV and time) is a standard feature
CE Approved
Each unit needs just 80 mm depth panel space
Specification
Fastron Electronics Part Number
BTCR/R-M1-A2-DS-C5
Control Output
Relay 3 Amp (Resistive)
Input
Multirange TC/RTD/4-20mA (Optional Linear voltage/current other than 4-20mA. Refer to datasheet)
Option 1
2nd Alarm
Option 2
RS485 Modbus RTU, SSR Cooling
Mounting Style
48 x 96mm Panel Mount
Load Voltage Range
15-50VDC
Termination Style
Screw
Weight
450g
Factory Pack Qty
1
Yes
UL
Yes
CE
Yes
Datasheet
BTC Series Brochure
BTC Series User Manual
BTC Series RS485 Comms Manual
Fine Tuning PID Adjustments
Fastron TC5-S-1A-2-T/R-2 PID Controller, 100-240VAC with 2 3 Amp Relay Alarms, K,E,J Thermocouple, Pt100 or Cu20, Optional Linear Current/Voltage, 48x48mm,4-20mA Output
4-digit displays (0.5s response)
Drip-proof / Dust-proof IP66 (front panel only)
Input signals can be converted to insulated -0-10V, Relay, 12VDC (SSR) and 4 to 20 mA DC outputs available
Each unit needs just 75 mm depth panel space
Now available will full Multirange input (K,E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, 96x48mm,4-20mA Output)
Specification
Fastron Part Number
TC5-S-1A-2-T/R-2
Control Output
4-20mA
Input
Multirange Type,K,E,J, Pt100, Cu50/(Optional)Linear Current 4(0)-20mA/(Optional)Linear Voltage 0-10(5)V
Option 1
2 3 Amp Relay Alarms standard (Excludes 48x48mm with SSR/Relay output)
Mounting Style
48 x 48mm Panel Mount
Supply Voltage
100 - 240VAC +/-10%
Termination Style
Screw
Sampling Time
100ms
Weight
150-270g
Factory Pack Qty
10
Datasheet
TC5 Datasheet and User Manual
FBS LCD 24/4M, 24VDC Surge Protection Device for IT Systems, LPZ 0A-2 of higher, 10kA
Specifications
Telebahn part number
FBS LCD 24/4M
Nominal Voltage
24VDC
No of Poles
4
Category IEC / EN / VDE
Type 2
Location of use
Communication/Signal Lines
Protection modes
L1+/L1-, L2+/L2- , for
Additional Remote Contacts
NO
Protective element
MOV
No Fault/Fault Indication
N/A
Surge discharge rating
Per pole 10kA (8/20uS)10KA) Max, 20kA (8/20uS)2.5KA) Nominal
Internal protection and safety
Thermal disconnector in each MOV
Weight
120g
Standards
IEC 61643-21; EN 61643.21; GB 18802.21
Datasheet
Product Datasheet
GDT/MOV/TVS Tester
SPD Tester
TX4L-U-D-D-2-96-N-N-N-N-N-N, Temp Controller, 96x96mm, 100-240VAC, Mutirange Input, 4-20mA Output, 2 Alarms
Mutirange Input
4-digit displays suit most industries including Temperature, Humidity, Pressure (0.5s response)
Drip-proof / Dust-proof IP66 (front panel only)
UL/CE Approved
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 70 mm depth panel space
EC Compliant
Specification
Fastron Part Number
TX4L-U-D-D-2-96-N-N-N-N-N-N
Control Output 1 (Heat)
4-20mA
Control Output 2 (Cool)
4-20mA
Input
Multirange (refer to datasheet) TC/RTD, 0-50mA/0-50mV
Alarm
Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)
Option 1
2nd Alarm Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)
Option 2
N/A
Mounting Style
96x96mm Panel Mount
Supply Voltage
85 - 265VAC
Termination Style
Screw
Weight
450g
Factory Pack Qty
1
ROHS
Yes
UL
Yes
CE
Yes
Datasheet
TX4L Series Instruction Manual
F920-A-XX-XX-XX - Signal Conditioner and +/-15VDC Bipolar Power Supply with Adjustable High and Low C/O Relay Alarm. +/- 4V Bipolar Input, For External LEM Hall Effect Sensor
Features
Isolated measurement of AC or DC currents using a Hall effect transducer with external aperture.
Incorporates an integrated input level display and power supply.
Wide measurement range available
Choice of standard outputs
Wide range isolated DC input supply
DIN Rail mounting
Signal Conditioned AC Average RMS or DC measurement output
On board bar graph display
User adjustable zero offset and span controls
Zero insertion loss in current measurement path
Earth leakage via differential Ipn for nominal Input ‘01’
Applications
Process control
Transportation
Petrochemical
Industrial
Earth Leakage
Energy Monitoring/Measurement
Automation
Delivery
Delivery in 3-5 days for small qty, Otherwise 4-6 weeks
Datasheet
Datasheet
Fastron FC5-S-W-1-G-4, 24VDC PID Controller with 1 Alarm, K,E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, Relay + 12VDC Output
4-digit displays (0.5s response)
Drip-proof / Dust-proof IP66 (front panel only)
Input signals can be converted to insulated -0-10V, Relay, 12VDC (SSR) and 4 to 20 mA DC outputs available
Each unit needs just 75 mm depth panel space
Specification
Fastron Part Number
FC5-S-W-1-G-4
Control Output
Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)/SSR 12VDC @20mA
Input
Multirange Type K,E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input
Option 1
1 Alarm standard
Mounting Style
48 x 48 Panel Mount
Supply Voltage
24VDC +/-15%
Termination Style
Screw
Sampling Time
100ms
Weight
150-270g
Factory Pack Qty
10
Datasheet
Datasheet
User Manual
Modbus Protocol
FC5 Communication Protocol
Fastron FC5-L-1A-2-G-2 PID Controller, 100-240VAC with 2 Relay Alarms, E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, 96x96mm,4-20mA Output
4-digit displays (0.5s response)
Drip-proof / Dust-proof IP66 (front panel only)
Input signals can be converted to insulated -0-10V, Relay, 12VDC (SSR) and 4 to 20 mA DC outputs available
Each unit needs just 75 mm depth panel space
Fastron Part Number
FC5-L-1A-2-G-2
Control Output
4-20mA
Input
Multirange Type,K,E,J, Pt100, Cu50/(Optional)Linear Current 4(0)-20mA/(Optional)Linear Voltage 0-10(5)V
Option 1
2 Relay Alarms standard (Excludes 96x96mm with SSR/Relay output)
Mounting Style
96x96mm Panel Mount
Supply Voltage
100 - 240VAC +/-10%
Termination Style
Screw
Sampling Time
100ms
Weight
150-270g
Factory Pack Qty
10
Datasheet & User Manual
Datasheet
User Manual
FC5 Communication Protocol
Fastron Electronics SCT-F36-630-5A, 5 Amp, 630Amp Measurement, Class 1 Split Core CT's
Features
Quick Release Split Core System
Cable Mount
5 Amp Output
Self Powered
Rated System Voltage 0.60/3kV
0.9M Flying Leads
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
SCT-F36-630-5A
Technology
Split Core AC Current Transformer
Ratio
630/5 Amp
Aperture Size
ø 35 mm
VA Rating
N/A
Accuracy Class
Class 1
Output
5 Amp (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
630Amp x 1.2
Termination Style
0.9M Flying leads
Unit Weight
400g
Factory Pack Qty
9
Datasheet
Product Datasheet
Stocked Split Core CT's Listing
Application Notes
Installation Guide
Types of Current Transformers - Blog
Cable Losses and CT's
High Accuracy or High Burden Requirements for CT's
Fastron F312 Series Proportional Phase Control Solid State Relay Controller
Proportional Phase Controller for SSR switching
Ratings from 25A to 90 Amp @ 90-600 VAC
Use any DC Control Solid State Relay
Use any Solid State Contactor
Instantaneous turn-on outputs
Specification
Fastron Part Number
F312 Series
Switching Type
Phase Angle or Burst (Selectable)
ROHS/CE/UL
Yes
Control Voltage
0 - 10V/0 - 5V/4 - 20mA/POT Input (at time of order)
Load Current
N/A based on SSR
Surge Capability
N/A based on SSR
Special Feature
Proportional Controller for SSR
Mounting Style
DIN Rail Mount
Load Voltage Range
90-415VAC
Dielectric Strength
4kV
Termination Style
Screw Terminal
Unit Weight
360g
Factory Pack Qty
20
Datasheet
Product Datasheet
F312 User Manual
Product Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
Equivalent Parts