LT 4000-S/SP24 C/L Hall Effect Current Sensor, Ipn = 3300 Amp, Isn = 660mA, +/-24VDC Supply, Busbar, X = 0.5%, panel mount
Heavy Item - No Free ShippingLEM LT 4000-S/SP24 C/L Hall Effect Current Sensor, Ipn = 3300 Amp, Isn = 660mA, +/-24VDC Supply, Busbar, X = 0.5%, panel mount Features Bipolar and insulated current measurement up tp 6000 Amp Current output Bandwidth DC to 100kHz Closed loop (compensated) current transducer Panel mounting Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low offset drift over temperature Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Applications Windmill Inverters Test and Measurement Substations AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Application Domain Industrial Standards EN 50178:1997 IEC61010-1:2010 UL 508:2010 Specification LEM Part Number LT 4000-S/SP24 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/- 15 VDC to +/- 24 VDC Bipolar, Isolated Load Current (RMS + DC) 3300 Amp Measurement Range +/- 6000 Amp Output 660 mA Isolation 6 kV Bandwidth DC-100 kHz Mounting Style Busbar Mount Operating Temperature Range -10°C / 85°C Accuracy 0.5% Termination Style M5 threaded studs Unit Weight 12.1kg Factory Pack Quantity 1 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
LT 2005-T C/L Hall Effect Current Sensor, Ipn = 2000 Amp, Isn = 400mA, +/-24VDC Supply, X = 0.3%, Busbar mount
Free Aus Post Shipping for $300 SpendLEM LT 2005-T C/L Hall Effect Current Sensor, Ipn = 2000 Amp, Isn = 400mA, +/-24VDC Supply, X = 0.3%, Busbar mount Features Bipolar and insulated current measurement up tp 3000 Amp Current output Bandwidth DC to 100kHz Closed loop (compensated) current transducer Panel mounting Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low offset drift over temperature Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Applications Windmill Inverters Test and Measurement Substations AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Application Domain Industrial Standards EN 50178:1997 IEC61010-1:2010 UL 508:2010 Specification LEM Part Number LT 2005-T Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/- 15 VDC to +/- 24 VDC Bipolar, Isolated Load Current (RMS + DC) 2000 Amp Measurement Range +/- 3000 Amp Output 400 mA Isolation 6 kV Bandwidth DC-100 kHz Mounting Style Busbar Mount Operating Temperature Range -10°C / 85°C Accuracy 0.3% Termination Style M5 theaded studs Unit Weight 4.4kg Factory Pack Quantity 4 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
LV 25P/SP17, C/L Hall Effect Voltage Sensor 10mA@10-500V, 25mA out, X = 0.9%
Free Aus Post Shipping for $300 SpendLEM LV Series Closed Loop AC/DC Hall Effect Voltage Sensor Features Bandwidth DC to 25kHz Multi Range through pin selection Closed loop transducer using Hall effect Compact and versatile PCB Mount Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number LV 25-P/SP17 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-12..15 VDC Bipolar, Isolated Primary Nominal Current (RMS + DC) 10 mA Measurement Range 10 - 700V (0 -14mA) Output 25 mA Isolation 2.5 kV Bandwidth DC-25 kHz Mounting Style PCB Mount Operating Temperature Range -40°C / 90°C Accuracy 0.9% Termination Style Through Hole PCB Unit Weight 22g Factory Pack Quantity 25 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
DK 100 C5, Hall Effect DC Current Transducer, 50, 75, 100A DC, 0-5V unipolar output, 20-50VDC supply
Free Aus Post Shipping for $300 SpendLEM DK 100 C5, Hall Effect DC Current Transducer, 50, 75, 100A DC, 0-5V unipolar output, 20-50VDC supply Compact and versatile Split Core DC current sensor, selectable 50, 75, 100 Amp DC. Choice of output types: 0-20mA, 4-20 mA, 0-5 V or 0-10 V Features ⌀19.1mm Aperture DC Unipolar Measurement 0-5V voltage output Busbar, or panel mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification LEM Part Number DK 100 C5 Technology DC Current Transformer with Process Output ROHS Yes Supply Voltage 20-50VDC Nominal Current (RMS + DC) 50,75,100 Amp Selectable Response Time < 100ms Output 0-5V Analogue Isolation 3kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 2% Termination Style 2 x UNC8 Cylindric Head Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
-
LTC 200-S/SP1, C/L Hall Effect Current Sensor, 200 Amp, 200mA Output, +/-15..24V, Panel Mount, w/ busbar, X = 0.5%, ø27.5mm
Free Aus Post Shipping for $300 SpendLEM LTC Series Open Loop AC/DC Hall Effect Sensor Features Bipolar and insulated current measurement up tp 400 Amp Current output Bandwidth DC to 100kHz Closed loop (compensated) current transducer Panel mounting Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low offset drift over temperature Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Applications Railway Equipment Windmill Inverters Test and Measurement Substations AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Application Domain Industrial Standards EN 50178:1997 IEC61010-1:2010 UL 508:2010 Specification LEM Part Number LTC 200-S/SP1 Technology Closed Loop Hall Effect Aperture ø27.5mm ROHS Yes Supply Voltage +/- 15 VDC to +/- 24 VDC Bipolar, Isolated Load Current (RMS + DC) 200 Amp Measurement Range +/- 400 Amp Output 200 mA Isolation 12 kV Bandwidth DC-100 kHz Mounting Style Panel Mount Operating Temperature Range -10°C / 85°C Accuracy 0.5% Termination Style Faston 45° 6.3 x 0.8mm and M4 threaded studs Unit Weight 300g Factory Pack Quantity 6 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition Accessories For Feet Kit or Busbar Kit see datasheet or LEM accessories for more details
-
DK 200 B5, Split Core Hall Effect DC Current Transducer, 100, 150, 200A DC, 0-5V unipolar output, 20-50VDC supply
Free Aus Post Shipping for $300 SpendLEM DK 200 B5, Split Core Hall Effect DC Current Transducer, 100, 150, 200A DC, 0-5V unipolar output, 20-50VDC supply Compact and versatile Split Core DC current sensor, selectable 100, 150, 200 Amp DC. Choice of output types: 4-20 mA, 0-5 V or 0-10 V Features Split Core DC Unipolar Measurement 0-5V voltage output Busbar, or panel mounting Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for busbar/cable up to 21.7mm sqr High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification LEM Part Number DK 200 B5 Technology DC Current Transformer with Process Output ROHS Yes Supply Voltage 20-20VDC Nominal Current (RMS + DC) 100,150,200 Amp Selectable Response Time < 100ms Output 0-5V Analogue Isolation 3kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 2% Termination Style 2 x UNC8 Cylindric Head Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
LTC 1000-TF C/L Hall Effect Current Sensor, 1000 Amp, 200mA Output, +/-15..24V, Panel Mount, w/ busbar & feet, X = 0.4%
Free Aus Post Shipping for $300 SpendLEM LTC 1000-TF Open Loop AC/DC Hall Effect Sensor Features Bipolar and insulated current measurement up tp 3000 Amp Current output Bandwidth DC to 100kHz Closed loop (compensated) current transducer Panel mounting Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low offset drift over temperature Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Applications Railway Equipment Windmill Inverters Test and Measurement Substations AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Application Domain Industrial Standards EN 50178:1997 IEC61010-1:2010 UL 508:2010 Specification LEM Part Number LTC 1000-TF Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/- 15 VDC to +/- 24 VDC Bipolar, Isolated Load Current (RMS + DC) 1000 Amp Measurement Range +/- 3000 Amp Output 200 mA Isolation 13.4 kV Bandwidth DC-100 kHz Mounting Style Busbar Mount and Panel Mount (with feet) Operating Temperature Range -10°C / 85°C Accuracy 0.4% Termination Style Faston 45° 6.3 x 0.8mm and M5 threaded studs Unit Weight 1270g Factory Pack Quantity 6 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition Accessories For Feet Kit or Busbar Kit see datasheet or LEM accessories for more details
-
777302, E-STOP Safety Relay 24-240VAC/DC, 3 x NO Safety Contacts, 1 x NC Auxiliary Contact, PNOZ X2.8P C 24-240VAC/DC 3n/o 1n/c
Free Aus Post Shipping for $300 SpendPilz 777302, E-STOP Safety Relay 24-240VAC/DC, 3 x NO Safety Contacts, 1 x NC Auxiliary Contact, PNOZ X2.8P C 24-240VAC/DC 3n/o 1n/c Safety Relay for Monitoring E-STOP Pushbuttons, safety gates and light barriers. Safety Features: Positive guides relay outputs, 3 x NO Safety Contacts, 1 x NC Auxiliary Contact Connection options for: E-Stop Pushbutton Safety Gate limit switch Reset button Light barriers LED Indicator for; Status channel 1/2 Supply Voltage Plug In connection terminals (cage clamp terminal or screw terminal) Redundant Circuit with in built monitoring Failsafe operation in case of component failure Correct Open/Close Operation is tested automatically in each on-off cycle Specification Pilz Part Number 777302, E-STOP Safety Relay PNOZ X2.8P C 24-240VAC/DC 3n/o 1n/c Function E-Stop Relay for E-stop, Gate or Lighting Supply Voltage 24 - 240 VAC/DC Relay Outputs 3 x NO Safety Contacts, 1 x NC Auxiliary Contact maximum Relay Current Safety Contacts 6 Amp, Auxiliary Contact 4 Amp Switch on Delay 340ms Delay on Energisation 10ms Termination Style Screw Weight 250g Certification UL Factory Pack Qty 1 Application Certification In accordance with EN 60947-5-1, EN 60204-1 and VDE 0113-1 Applications 2 in accordance with IEC/EN 61131-2 Protection rating IP40 (Front), IP20 (Rear) Datasheet Product Datasheet User Manual
-
LTC 350-T C/L Hall Effect Current Sensor, 350 Amp, 175mA Output, +/-15..24V, Panel Mount, w/ busbar, X = 0.3%
Free Aus Post Shipping for $300 SpendLEM LTC 350-T Open Loop AC/DC Hall Effect Sensor Features Bipolar and insulated current measurement up tp 1200 Amp Current output Bandwidth DC to 100kHz Closed loop (compensated) current transducer Panel mounting Insulated plastic case recognized according to UL 94-V0 With Busbar Advantages Very good linearity High accuracy Low offset drift over temperature Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Applications Railway Equipment Windmill Inverters Test and Measurement Substations AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Application Domain Industrial Standards EN 50178:1997 IEC61010-1:2010 UL 508:2010 Specification LEM Part Number LTC 350-T Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/- 15 VDC to +/- 24 VDC Bipolar, Isolated Load Current (RMS + DC) 350 Amp Measurement Range +/- 1200 Amp Output 175 mA Isolation 12 kV Bandwidth DC-100 kHz Mounting Style Busbar Mount Operating Temperature Range -10°C / 85°C Accuracy 0.5% Termination Style Faston 45° Nickel Plated Unit Weight 650g Factory Pack Quantity 6 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition Accessories For Feet Fixing kit see Part # 93.34.43.100.0
-
777307, E-STOP Safety Relay 48-240VAC/DC, 2 x NO Safety Contacts, 1 x NC Auxiliary Contact, PNOZ X2P 48-240VAC/DC 2n/o
Pilz 777307, E-STOP Safety Relay 48-240VAC/DC, 2 x NO Safety Contacts, 1 x NC Auxiliary Contact, PNOZ X2P 48-240VAC/DC 2n/o Safety Relay for Monitoring E-STOP Pushbuttons, safety gates and light barriers. Safety Features: Positive guides relay outputs, 2 x NO Safety Contacts, 1 x NC Auxiliary Contact Connection options for: E-Stop Pushbutton Safety Gate limit switch Reset button Light barriers LED Indicator for; Status channel 1/2 Supply Voltage Plug In connection terminals (cage clamp terminal or screw terminal) Redundant Circuit with in built monitoring Failsafe operation in case of component failure Correct Open/Close Operation is tested automatically in each on-off cycle Specification Pilz Part Number 777307, E-STOP Safety Relay PNOZ X2P 48-240VAC/DC 2n/o Function E-Stop Relay for E-stop, Gate or Lighting Supply Voltage 48 - 240 VAC/DC Relay Outputs 2 x NO Safety Contacts, 1 x NC Auxiliary Contact maximum Relay Current Safety Contacts 6 Amp, Auxiliary Contact 4 Amp Switch on Delay 340ms Delay on Energisation 10ms Termination Style Screw Weight 250g Certification UL Factory Pack Qty 1 Application Certification In accordance with EN 60947-5-1, EN 60204-1 and VDE 0113-1 Applications 2 in accordance with IEC/EN 61131-2 Protection rating IP40 (Front), IP20 (Rear) Datasheet Product Datasheet User Manual
$617.00
$728.06 inclGST -
DK 300 B420, Split Core Hall Effect DC Current Transducer, Multirange 150, 225, 300A DC, 4-20mA unipolar output, 20-50VDC supply
LEM DK 300 B420, Split Core Hall Effect DC Current Transducer, Multirange 150, 225, 300A DC, 4-20mA unipolar output, 20-50VDC supply Compact and versatile Split Core DC current sensor, selectable 150, 225, 300 Amp DC. Choice of output types: 4-20 mA, 0-5 V or 0-10 V Features Split Core DC Unipolar Measurement 0-10V Voltage output Busbar or panel mounting Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for busbar/cable up to 21.7mm sqr High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification LEM Part Number DK 300 B420 Technology DC Current Transformer with Process Output ROHS Yes Supply Voltage 20-20VDC Nominal Current (RMS + DC) 150,225,300 Amp Selectable Response Time < 100ms Output 4-20mA Analogue Isolation 3kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 2% Termination Style 2 x UNC8 Cylindric Head Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
$1,214.00
$1,432.52 inclGST