Search results for "텔레@CASHFILTER365!!국내거래소fds뚫어주는곳트론리플전송대행"
-
ATM-DAO(20-4mA)-D-1, Signal Converter, 20-4mA Input, 22-60VAC/DC Aux, 4-20mA output
Free Aus Post Shipping for $300 SpendSignal Transmitter ATM-DAO(20-4mA)-D-1, Signal Converter, 20-4mA Input, 22-60VAC/DC Aux, 4-20mA output Adjustable Zero and Span Setting Digital DIsplay 250mS Response Time PC 94 UL V0 Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type) or 0-10V/0-5V (For Direct Voltage Type) Each unit needs just 50mm x 120mm depth DIN Rail cabinet space Specification Fastron Electronics Part Number ATM-DAO(20-4mA)-D-1 Control Output 4-20mA Input 20-4mA Over Range x 1.2 Operating Temperature 0 - 60°C Load Voltage 24VDC Span Adjustment Range +/-10% Zero Adjustment Range +/-5% Termination Style Screw Mounting Style DIN Rail Mount Case Material PC - UL 94 V0 Weight 170g Factory Pack Qty 1 Datasheet Product Datasheet
Free Aus Post Shipping for $300 Spend$295.00
$348.10 inclGST -
FEFN201-25-T, 2 Stage 3 Phase + N EMC (RFI) Line Filter for Inverter input, 25 Amp, 520VAC, Excellent Attenuation
Fastron FEFN201-25-T, 2 Stage 3 Phase + N EMC (RFI) Line Filter for Inverter input, 25 Amp, 520VAC, Excellent Attenuation Features Line filter suitable for 3 Phase + N systems with inverters or other noisy equipment Wide Temperature Range Characteristics Designed for demanding applications Protection against interference voltage from the mains Possible interferences generated in the equipment are strongly attenuated Suitable for use in equipment according to UL 1238, CSA22.2N).8, IEC/EN 60939 Line filter suitable for low current Inverter such as PV or battery storage systems Specification Schurter Part Number FEFN201-25-T Rated Voltage 520V 3 Phase Rated Current 25Amp @ 40 Deg C Filter Stages 2 Stage Operating Temperature -40°C to 100°C Filter Type Very High Symmetrical and Asymmetrical Attenuation Leakage Current 0.5mA Mounting Panel Mount Material Metal Termination Style Screw Weight 1.3kg Factory Pack Qty 4 Protection Class Suitable for equipment according to IEC/UL 60950 Isolation 1.3 - 2.75kV VDE/UL/CSA/ROHS Yes Datasheet Product Datasheet
$159.00
$187.62 inclGST -
FRS7-B+C 37.5/440 (3+0)R, Class I,II / Type 1,2 / B,C, Surge Protection Device (SPD), 3 Pole 37.5kA (12.5kA per pole), 440VAC, DIN Rail Mount, With Remote Contacts, L/N-PE, L-PEN, L-N, N-PE High Energy MOV and GDT
Trent FRS7-B+C 37.5/440 (3+0)R, Class I,II / Type 1,2 / B,C, Surge Protection Device (SPD), 3 Pole 37.5kA (12.5kA per pole), 440VAC, DIN Rail Mount, With Remote Contacts, L/N-PE, L-PEN, L-N, N-PE High Energy MOV and GDT Specifications Trent part number FRS7-B+C 37.5/440 (3+0)R Nominal Voltage (Un) L-L 400VAC Maximum Voltage (Uc) L-L 440VAC No of Poles 3 Voltage Protection Level (Up) < 2.2kV Category IEC / EN / VDE Class I,II / Type 1,2 / B,C Location of use Main Distribution Boards Protection modes L/N-PE, L-PEN, L-N, N-PE High Energy MOV and GDT Additional Remote Contacts YES Protective element MOV + GDT Surge discharge rating Imax up to 50 kA, or 12.5kA per pole Internal protection and safety Thermal disconnector in each MOV Standards IEC/EN 61643-11 Datasheet Product Datasheet
$169.00
$199.42 inclGST -
FBS RK 24 ST-II, Slim Surge Protection Device For RS485, 2 Pole, 24VDC, 5kA per line @ Imax(8/20uS)(KA), -40 to +80 Deg C Operation; YD/T 1542, Nominal Discharge 5kA, Maximum Discharge 10kA, LPZ 1 -2 or higher, Slim 7mm Wide Module
FBS RK 24 ST-II, Slim Surge Protection Device For RS485, 2 Pole, 24VDC, 5kA per line @ Imax(8/20uS)(KA), -40 to +80 Deg C Operation; YD/T 1542, Nominal Discharge 5kA, Maximum Discharge 10kA, LPZ 1 -2 or higher, Slim 7mm Wide Module Application IT Systems Coarse and FIne Protection Industrial Control System Measurement System Device Control Specifications Trent part number FBS RK 24 ST-II Nominal Voltage 24VDC No of Poles 4 Category IEC / EN / VDE LPZ 0 -2 or higher Location of use IT Communications Line/signals Protection modes TX+/TX-/RX+/RX-/GND Additional Remote Contacts N/A Protective element MOV No Fault/Fault Indication N/A Surge discharge rating Per pole 5kA (8/20uS)9KA) Max, 10kA (8/20uS)9KA) Nominal Internal protection and safety Thermal disconnector in each MOV Weight 50g Standards IEC61643-21; GB 18802.21 ; YD/T 1542 Datasheet Product Datasheet GDT/MOV/TVS Tester SPD Tester
$49.00
$57.82 inclGST -
FBS RK 5 TC-DI, Slim Surge Protection Device For RS485 2 Pole, 5VDC, 5kA per line @ Imax(8/20uS)(KA), -40 to +80 Deg C Operation; YD/T 1542, Nominal Discharge 5kA, Maximum Discharge 10kA, LPZ 1 -2 or higher, Slim 7mm Wide Module
FBS RK 5 TC-DI, Slim Surge Protection Device For RS485 2 Pole, 5VDC, 5kA per line @ Imax(8/20uS)(KA), -40 to +80 Deg C Operation; YD/T 1542, Nominal Discharge 5kA, Maximum Discharge 10kA, LPZ 1 -2 or higher, Slim 7mm Wide Module Application IT Systems Coarse and FIne Protection Industrial Control System Measurement System Device Control Specifications Trent part number FBS RK 5 RS-II Nominal Voltage 5VDC No of Poles 4 Category IEC / EN / VDE LPZ 0 -2 or higher Location of use IT Communications Line/signals Protection modes TX+/TX-/RX+/RX-/GND Additional Remote Contacts N/A Protective element MOV No Fault/Fault Indication N/A Surge discharge rating Per pole 5kA (8/20uS)9KA) Max, 10kA (8/20uS)9KA) Nominal Internal protection and safety Thermal disconnector in each MOV Weight 50g Standards IEC61643-21; GB 18802.21 ; YD/T 1542 Datasheet Product Datasheet GDT/MOV/TVS Tester SPD Tester
$49.00
$57.82 inclGST -
DTC1-A/M-TR, DIN Rail Mount Process Transmitter with Alarm Function, Multirange TC/RTD/4-20mA, 85-265VAC, 4-20mA output
Fastron DTC1-A/M-TR, DIN Rail Mount Process Transmitter with Alarm Function, Multirange TC/RTD/4-20mA, 85-265VAC, 4-20mA output Filter Time Constant Function Converter function 2 Input 1 Output, and 1 Input Two Output Versions available 4-digit display. Suit most industries including Temperature, Humidity, Pressure (0.5s response) CE Approved Each unit needs just 22.5mm width Din Rail space EC Compliant (Details) Various specials available for unique applications. Specification Fastron Part Number DTC1-A/M-TR Transmitter Output 4-20mA Input Multirange RTD/K/J/R/S/B/E/T/4-20mA/N/W1/W2 Alarm Relay 3A(Resistive), 1A(Inductive load cos ??=0.4), 240VAC/30VDC Options None Mounting Style 22.5 x 75mm Din Rail Mount Supply Voltage 85 - 265VAC Termination Style Screw Weight 230g Factory Pack Qty 1 CE Yes ?? Selection Chart Datasheet DTC1 Brochure DTC1User Manual DTC1 User Manual Comms versions Alarm Table DTC1 (Program Control Version) User Manual
$209.00
$246.62 inclGST -
FRSS-485-24VDC, Surge Protection Device For RS422/RS485 Devices 2 Pole Unbalanced , Un = 24VDC, Uc = 30VDC, 5kA per line @ Imax(8/20uS)(KA), -40 to +80 Deg C Operation; YD/T 1542, Nominal Discharge 5kA, Maximum Discharge 10kA, Slim 18mm Wide Module
FRSS-485-24VDC, Surge Protection Device For RS422/RS485 Devices 2 Pole, Un = 24VDC, Uc = 30VDC, 5kA per line @ Imax(8/20uS)(KA), -40 to +80 Deg C Operation; For Unbalanced RS485/RS422, Nominal Discharge 5kA, Maximum Discharge 10kA, LPZ 1 -2 or higher, Slim 18mm Wide Module Application IT Systems Coarse and Fine Protection Industrial Control System Measurement System Device Control 2 Pole Unbalanced RS422/RS485 Systems Specifications Trent part number FRSS-485-24VDC Nominal Voltage (Un) 24VDC Maximum Permissable Voltage (Uc) 30VDC No of Poles 2 Location of use IT Communications Line/signals Protection modes TX+/TX-/RX+/RX-/PE Additional Remote Contacts N/A Protective element MOV No Fault/Fault Indication N/A Surge discharge rating Per pole 5kA (8/20uS) Nominal, 10kA (8/20uS) Max Nominal Internal protection and safety Thermal disconnector in each MOV Weight 150g Standards IEC61643-21; GB 18802.21 ; YD/T 1542 Datasheet Product Datasheet GDT/MOV/TVS Tester SPD Tester
$60.00
$70.80 inclGST -
MFC500-16-416F3, Thyristor Diode Module, 500 Amp, 1600V, to Replace TD425N
Techsem MFC500-16-416F3, Thyristor Diode Module, 500 Amp, 1600V, to Replace TD425N Features Thyristor for line frequency Pressure Contact Technology Electrically insulated base plate Industrial standard package Long-term stability 3600V Isolation 60mm Base Width Applications Power Converter Line rectifying 50/60 Hz Deep Cycle Applications Controlled Rectifiers Softstart AC motor control AC power control Lighting and temperature control Specification Infineon Part Number MFC500-16-416F3 Vrrm 1600V Diode Configuration Thyristor Diode Module IF(av) @ 85 Deg C 425 Amp Package Size W:60mm L:144mm D:52mm Itsm 14.5 kA VF(to) 0.8V Tj(max) 125°C rF 0.34mΩ I(gt) @ 25 Deg C 250mA Terminals M10 Screw Hole Centres 80mm x 48mm(M6) Gate Terminals Spade (A 2.8 - 0.8 DIN 46244) R th(j-c) 0.078°C/W R th(c-h) 0.02°C/W Weight 1500g Mounting Torque 6 Nm (12 Nm Terminals) Factory Pack Qty 2 Certification UL Listed, ROHS Techsem Headquarters China Datasheet Product Datasheet
$325.00
$383.50 inclGST -
DTCV5-A/M-TR, DIN Rail Mount Process Transmitter with Alarm Function, 0-5V Input, 85-265VAC, 4-20mA Output
Fastron DTCV5-A/M-TR, DIN Rail Mount Process Transmitter with Alarm Function, 0-5V Input, 85-265VAC, 4-20mA Output Filter Time Constant Function Converter function 2 Input 1 Output, and 1 Input Two Output Versions available 4-digit display. Suit most industries including Temperature, Humidity, Pressure (0.5s response) CE Approved Each unit needs just 22.5mm width Din Rail space EC Compliant (Details) Various specials available for unique applications. Specification Fastron Part Number DTCV5-A/M-TR Transmitter Output 4-20mA Input 0-5V Alarm Relay 3A(Resistive), 1A(Inductive load cos ??=0.4), 240VAC/30VDC Options None Mounting Style 22.5 x 75mm Din Rail Mount Supply Voltage 85 - 265VAC Termination Style Screw Weight 230g Factory Pack Qty 1 CE Yes ?? Selection Chart Datasheet DTC1 Brochure DTC1User Manual DTC1 User Manual Comms versions Alarm Table DTC1 (Program Control Version) User Manual
$209.00
$246.62 inclGST