Fastron Electronics AM5A-A-DV1-A Digital Panel Meter & Transmitter
Adjustable Zero and Span Setting
Adjustable Display Scaling
Large 5 Digit 20.3mm (8 Inch) LED Display
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 96 x 48mm Panel Space
90mm Depth
Specification
Fastron Electronics Part Number
AM5P-C4225A-NAN
Signal Conditioned Output
4-20mA
Input
0 - 50mVDC
Over Range
x 1.5
Operating Temperature
0 - 60°C
Supply Voltage
110- 240VAC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
96 x 48mm Panel Mount
Case Material
PC - UL 94 V0
Weight
320g
Factory Pack Qty
1
Datasheet
Product Datasheet
User Manual
Application Notes
Panel Meters Blog Articles
Fastron FDV-500-V05-12, DC Voltage Transducer, Din Rail Mount, 0-500VDC, 5V output, 12VDC Supply Voltage, 150mS Response
150mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 5V DC output (for voltage output type)
Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space
Specification
Fastron Part Number
FDV-500-V05-12
Analogue Output
5V
Input
0 - 500VDC
Measurement Range
120%
Overload
150% Continuous
Operating Temperature
-30 - 70°C
Operating Voltage
12VDC +/-15%
Accuracy
1%
Response Time
150mS
Voltage Isolation (1 min)
2.5kV
Termination Style
Screw
Mounting Style
DIN Rail Mount
Safety
CE, UL94V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
Fastron Electronics HF121-12/0.4-25-14%K, 25kVar 400VAC 14% Detuned Reactor for Power Factor Correction Capacitor Banks, 3.07mH(400VAC) 4.914mH(525VAC)
Specification
Technical Features
HF121-12/0.4-25-14%K
Electrical
Voltage
400V System/525V Capacitor
Network Frequency
50/60Hz
Nominal Power
12.5,25,40,50kvar
Inductance
3.07mH(400VAC) 4.914mH(525VAC)
Value of p%
14% (134 / 160Hz)
Type of Conductor
Aluminium/Copper(optional)
Tolerance L
5%
Linearity (5% L)
1.8 x In
Isolation Voltage
kV
Maximum Room Temperature
-10 to 45 Deg C
Internal isolation
Class F(155°C), Class H (180°C Optional)
Maximum Overload
Permanent
1.17 x In
Temporary
2 x In
Safety
Protection Thermostat
Opens at 90 °C
Degree Protection
IP00
Installation
Indoor
Standards
EN-60289, IEC60076
Weight
21kg
Datasheet
Product Datasheet
Installation Guide
HF121 Series Installation Guide
Crydom D53TP50DH + KS300, SSR 3 Phase 4-32VDC Control, 50A, 48-530VAC Load, LED Status Indicator, Cover + HSP-3 Thermal pad.
Features
Ratings from 25A to 50 Amp @ 70-480 VAC
SCR output for heavy industrial loads
Zero voltage or Instantaneous turn-on outputs
UL/CE/ROHS Approved
IP20 Cover Available
AC & DC control types
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
D53TP50DH + KS300
Switching Type
Zero Crossing
ROHS/CE/UL
Yes
Control Voltage
4-32VDC
Load Current
50 Amp (rms) per Phase
Surge Capability
597 Amp (peak)
Special Feature
LED Status Indicator + IP20 Cover + Thermal Pad
Mounting Style
Panel Mount
Load Voltage Range
48-530VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
315g
Factory Pack Qty
10
Datasheet
Product Datasheet
Equivalent
Contact Us for Possible Replacement
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Fastron Electronics BTCR/A-M-A3-EI, PID Controller 48x96mm, 85-265VAC, 4-20mA output 3 Alarms, Event input (2xSV ), Multirange TC/RTD/4-20mA Input
4-digit displays suit most industries including Temperature, Humidity, Pressure (0.5s response)
Dust-proof IP56 (front panel only)
Optional 32-step pattern (for SV and time) is a standard feature
CE Approved
Each unit needs just 80 mm depth panel space
Specification
Fastron Electronics Part Number
BTCR/A-M-A3-EI
Control Output
4-20mA
Input
Multirange TC/RTD/4-20mA (Optional Linear voltage/current other than 4-20mA. Refer to datasheet)
Option 1
2nd and 3rd Alarm
Option 2
Event Input (2 x SV)
Mounting Style
48 x 96mm Panel Mount
Load Voltage Range
100-240VAC
Termination Style
Screw
Weight
450g
Factory Pack Qty
1
CE
Yes
Datasheet
BTC Series Brochure
BTC Series User Manual
BTC Series RS485 Comms Manual
Fine Tuning PID Adjustments
Rishabh Rish Con P 4WUB 100-500V 1/5A 60-300U 20 D, Active Power/Reactive Power/Apparrent Power/Phase Angle/Power Factor Transducer 4 wire, 100-500V, 5Amp measurement,60-300VAC/DC Supply, 2 x 0-20mA/4-20mA/0-10V output, with display
Measures Active Power/Phase Angle/Power Factor
Measures Apparent/Reactive/Active Power
Digital output setting 0-20mA/4-20mA/0-10V
Dual output version available
300mS response time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 43.75 x 100.9 mm depth DIN Rail cabinet space
Specification
Rishabh Part Number
Rish P 4WUB 100-500V 1/5A 60-300U 20 D
Functions
Power/Phase Angle/Power Factor Transducer 4 wire
Measurement Output
4-20mA/0-20mA/0-10V User Selectable
Input
57 - 500VAC 50/60Hz
Overload (Continuous)
120%
Overload (1 second)
150%
Operating Temperature
-40 - 70°C
Supply Voltage
60 - 300VAC, or 24-60VAC/DC
Accuracy
0.2%
Response Time
300mS
Termination Style
Screw
Mounting Style
DIN Rail Mount
Safety
IP40/IP20 EN60529 Protection Class II EN61010
Weight
400g
Factory Pack Qty
1
Datasheet
Product Datasheet
Technical Support
Rish Con P setup procedure blog
Rishabh Rish Con-I(5A)-F-H-O1A1-O200-D-Z-Z, AC Current Transducer, Input Programmable True RMS 50Hz, 1A-5A Full Scale, 4-20mA, 60-300VAC/DC Supply, with display
Digital output setting 0-20mA/4-20mA/0-10V
Dual output version available
300mS response time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 43.75 x 100.9 mm depth DIN Rail cabinet space
Specification
Rishabh Part Number
Rish Con-I(5A)-F-H-O1A1-O200-D-Z-Z
Measurement Output
4-20mA/0-20mA/0-10V User Selectable
Input
1 - 5 Amp 50/60Hz
Overlaod (Continuous)
120%
Overload (1 second)
150%
Operating Temperature
-40 - 70°C
Supply Voltage
60 - 300VAC
Accuracy
0.2%
Response Time
300mS
Termination Style
Screw
Mounting Style
DIN Rail Mount
Safety
IP40/IP20 EN60529 Protection Class II EN61010
Weight
400g
Factory Pack Qty
1
Datasheet
Product Datasheet
Technical Support
Rish Con P setup procedure blog
Fastron Electronics FESCT-055-400-5-IP65, 400Amp Measurement, 5 Amp Output Split Core CT's, Class 1, w/10M Flying leads, ø 55mm Aperture
Features
Quick Release Split Core System
10m Flying Leads
ø 55mm
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.60/3kV
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurement, 5 Amp Outputs
Specification
Fastron Electronics Part Number
FESCT-055-400-5-IP65
Technology
Split Core AC Current Transformer
Ratio
400/5A
Aperture Size
ø 55mm
VA Rating
2.5VA
Accuracy Class
Class 1
Output
5 Amp (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Dimensions
180x138x52mm
Mounting Style
Panel Mount
Operating Temperature Range
-35°C / 55°C
Continuous Current (max)
400Amp x 1.2
Termination Style
10M Twisted Pair 0.34mm^2
Unit Weight
2000g
Factory Pack Qty
9
Datasheet
Product Datasheet
Application Notes
Installation Guide
Crydom B614F-2T, Single Phase Half Controlled Rectifier Bridge, 42.5 Amp, 480VAC Line
Features
For AC or DC Variable Voltage Output Up to 15KW
Electrically insulated base plate
Industrial standard package
2500V Isolation
UL Recognized E72445
Applications
Power Supplies
Rectifier for drives applications
Rectifiers for UPS
Battery Chargers
Spec
Crydom Part Number
B612F-2T
AC Line voltage
480V
Device Configuration
Single Phase Half Controlled Rectifier Bridge,
DC Output @ 85 Deg C
42.5 Amp
Package Size
W:31.7mm L:63.5mm D:19.7mm
Itsm
250 A
VF
1.65V
Tj(max)
125°C
rF
Not Published
Terminals
Faston (6.3mm)
Hole Centres
48.2mm (M5)
Gate Terminals
Faston (6.3mm)
R th(j-c)
0.9°C/W
R th(c-h)
Not Published
Weight
42.5g
Isolation
2.5kV
Factory Pack Qty
20
Certification
UL Listed
Crydom Headquarters
United States
Datasheet
Product Datasheet
Alternatives
See PSD51/18 for higher rated equivalent
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Rishabh Rish Con M-22132, Class 0.5 Power Transducer 4 wire, 20-480V L-L, 5Amp measurement, 85-253VAC/90-320VDC Supply, 4 x Analogue -20-20mA/4-20mA/-10-10V output, USB Programming Port, Modbus RTU Comms, 750 OHM Load Resistance, without display
Measures Active Power/Phase Angle/Power Factor
Measures Apparent/Reactive/Active Power
Analogue output setting 0-20mA/4-20mA/0-10V
300mS response time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 122.5 x 66 x 106.5mm depth DIN Rail cabinet space
Specification
Rishabh Part Number
Rish Con M-22132
Functions
Active Power/Phase Angle/Power Factor Transducer 4 wire
Measurement Output
4 x 4-20mA/0-20mA/0-10V User Selectable
Relay Output
N/A
Relay Type
Voltage Free Contact, 0.5 Amp @ 250VAC
Input
20 - 480VAC L-L 50/60Hz
Overload (Continuous)
120%
Overload (1 second)
150%
Operating Temperature
-10 - 55°C
Supply Voltage
85-253VAC/90-320VDC
Accuracy
0.2%
Response Time
300mS
Termination Style
Screw
Mounting Style
DIN Rail Mount
Mounting Size
122.5 x 66 x 106.5mm
Safety
IP40/IP20 EN60529 Protection Class II EN61010
Weight
400g
Factory Pack Qty
1
Datasheet
Product Datasheet
Product User Manual
Technical Support
Rish Con P setup procedure blog
FPT-135 4000/1A 5P20 15VA Protection Class CT, 4000/1A, Class 5P20 15VA, 135 x 81mm Aperture
Features
Built In Sealable Terminal Covers
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
VDE0414-44-1, GB1208-2006, EN 60044-1 and IEC 61869-2
Applications
Protection Relays
Safety Equipment
Fault Monitoring
??
Specification
Fastron Electronics Part Number
FPT-135 4000/1A 5P20 15VA
Technology
Protection Class Current Transformer
Ratio
4000/5
Aperture Size
81 x 135mm
VA Rating
15VA
Accuracy Class
Class 5P20
Output
1 Amp AC (?%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-10??C / 50??C
Continuous Current (max)
4000Amp x 1.3
Termination Style
Screw
Stanbards
VDE0414-44-1, GB1208-2006, EN 60044-1 and IEC 61869-2
Unit Weight
7kg
Factory Pack Qty
1
??
Datasheet
Product Installation Guide and Datasheet
??
FPT-135 750/5A 5P35 5VA Protection Class CT, 750/5A, Class 5P35 5VA, 135 x 81mm Aperture
Features
Built In Sealable Terminal Covers
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
VDE0414-44-1, GB1208-2006, EN 60044-1 and IEC 61869-2
Applications
Protection Relays
Safety Equipment
Fault Monitoring
??
Specification
Fastron Electronics Part Number
FPT-135 750/5A 5P35 5VA
Technology
Protection Class Current Transformer
Ratio
750/5
Aperture Size
81 x 135mm
VA Rating
5VA
Accuracy Class
Class 5P35
Output
5 Amp AC (?%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-10??C / 50??C
Continuous Current (max)
750Amp x 1.3
Termination Style
Screw
Stanbards
VDE0414-44-1, GB1208-2006, EN 60044-1 and IEC 61869-2
Unit Weight
7kg
Factory Pack Qty
1
??
Datasheet
Product Installation Guide and Datasheet
??