Fastron Electronics SCT-F36-400, 0.333V, 400Amp measurement Split Core CT's Class 1, 35mm Aperture
Features
Quick Release Split Core System
Cable Mount
0.333V Output
Self Powered
Rated System Voltage 0.60/3kV
0.9M Flying Leads
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
SCT-F36-400
Technology
Split Core AC Current Transformer
Ratio
400/0.333V
Aperture Size
ø 35 mm
VA Rating
N/A
Accuracy Class
Class 1
Output
0.333V (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
400Amp x 1.2
Termination Style
0.9M Flying leads
Unit Weight
400g
Factory Pack Qty
9
Datasheet
Product Datasheet
Stocked Split Core CT's Listing
Application Notes
Installation Guide
Types of Current Transformers - Blog
Cable Losses and CT's
High Accuracy or High Burden Requirements for CT's
Fastron Electronics Fast ONE SVG 100kvar-400V-4W, 400VAC L-L Static Var Generator(SVG)/Inverter for Reactive Power Correction and Compensation, Wall Mounted
For Automatic Switching of Power Factor Correction Capacitors according to changing site conditions.
Features
Automatic Power Factor Correction up to Cos φ = 0.99
Auto rotation of same capacitors for long life
Overtemperature Alarm
Optional RS485 Comms
IEC 654-1, UL Approved
3 Year Fastron Electronics Warranty
Modular Construction for Rack or Wall Mount Installtions
Perfect for Residential Applications
Stack multiple modules for larger Power Factor Correction Requirements
Specification
Fastron Part Number
Fast ONE SVG 100kvar-400V-4W
Mounting
Wall Mounted
Function
Reactive Power Correction
Configuration
4 Wire
Nominal Voltage (Un)
400VAC Line to Line 50Hz
Switch Delay Time
Instant Correction/Inverter Based
Desired Power Factor
0.99 IND - 0.99 CAP
LCD Display Accuracy
Voltage +/-0.5%, Frequency +/-0.1%, Power +/-1% Energy Class 1
Phase Angle Error
+/- 1% at I > 3% of range
Comms
RS485 (Optional)
Termination Style
Screw
Dimensions
540x278x540mm
Weight
40kg
Certification
EN 61000-6-4:2007+A1:2011
EN 61000-6-2:2005
EN 61000-3-2:2014
EN 61000-3-3:2013+A1:2019
Factory Pack Qty
1
Material of housing
PC/ABS Unflammable, according to UL 94 V-0, & Stainless Steel Painted RAL 1013
Enclosure protection
IP21
Safety
According to EN 61 010-1, installation category III Pollution degree 2
Operating Temperature
-20...55 °C
Datasheet
Datasheet
User Manual
Fastron GFIN/150M-DR, GFIN Heatsink for Solid State Relays, 150mm long with DIN Rail Clip 0.78 Deg C per Watt
DIN Rail or Panel Mount heat sink types
Suitable for SSR Mounting
Pre drilled for single or 3 phase SSR
Raw Finish
Specification
Fastron Part Number
GFIN/150M-DR
Mounting Type
Din Rail
Suitable SSR Rating
60/75 Amp
Dimensions (without SSR)
L:150mm x W:67mm x 88.5mm
Thermal Impedance
0.78°C/W
Unit Weight
1000g
Factory Pack Qty
10
Datasheet
Product Datasheet
Trent HS211A, Panel Mount Heat Sink, 2.7 Deg C per Watt (Heatsink Only). Suitable for 44x 57mm SSR only.
Features
Panel Mount heat sink
Suitable for SSR Mounting
Pre drilled for single or Dual SSR
Panel Mount only
Spec
Fastron Part Number
HS211A
Mounting Type
Panel Mount Only
Suitable SSR Rating
25 Amp
Dimensions (without SSR)
L:80mm x W:50mm x D:50mm
Thermal Impedance
2.7°C/W
Load Current @ 40 Deg C
21 Amp
Load Current @ 50 Deg C
17 Amp
Unit Weight
120g
Factory Pack Qty
10
Datasheet
Product Datasheet
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Fastron FDH2548ZA4 + HS211B, Panel Mount Solid State Relay, 90-280VAC Control Input, 70-480VAC Output, 21 Amps
Features
Ratings from 25A to 125 Amp @24-280 VAC
SCR output for heavy industrial loads
Zero voltage or instantaneous turn-on outputs
UL/CE/ROHS Compliant
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Panel Mount
Spec
Part Number
FDH2548ZA4 + HS211B
Switching Type
Zero Crossing
Control Voltage
90-280VAC
Load Current
21 Amp (rms) @ 40 Deg C
Surge Capability
239 Amp (peak)
Special Feature
IP20 Cover
Mounting Style
Panel Mount
Load Voltage Range
70-480VAC
Max Non Repetitive Peak Voltage
600 Vp
Termination Style
Screw Terminals
Dimensions
L:81mm x W:45mm x D:73.4mm
Unit Weight
296g
Factory Pack Qty
20
Datasheet
HS211A
FDH
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Iskra Doo K08MG-10-24VDC, AC Miniature Contactor 240/400/500/690V, with 24VDC Control Voltage, 4 Pole 4 x NO, Nominal Current = 15.5 Amps
Capacitor duty contactors are designed to meet the requirements of capacitor duty applications. Contactors are fitted with a block of three auxiliary contacts connected in series with six quick discharge damping resistors, two per each phase. Peak current is limited to the value within the contactor making capacity.
Features :
High contact reliability at low voltages
High electrical and mechanical endurance and high switching capacity
Four and Three-pole contactors
Optional auxiliary contacts
Ratings from 6 Amp to 1000 Amp
UL, CSA Approved
Advantages :
Saves costs of expensive replacement
Long electrical life
Reduces watt losses during “ON” condition, saves energy
High safety
No risk of dangerous voltage
Less maintenance and downtime
Standard control voltages: 24 V 50/60 Hz, 240 V 50/60 Hz, 415 V 50/60 Hz
Specification
Iskra Doo Part Number
K08MG-10-24VDC
Functions
4 Pole Contactor 4 x NO
Nominal Voltage
230/400/500/690VAC @ 50/60Hz
Current Carrying Capacity as per UL
15.5 Amp Continuous @ 55 Deg C
Auxiliary Contacts
Optional
Trip Delay Time
2-10ms
Electrical Life
200,000 Ops
Operating Temperature
-25 to 40 Deg C
Mechanical Operations
10.000,000 Ops
Control Voltage
24VDC
Power Dissipation
0.36W
Approvals
UL, CSA, CE
Standards
IEC/EN 60947-4-1, AS/NZ 61009-1
Weight
200g
Enclosure Material
UL94
Factory Pack Qty
1
Datasheet
Product Datasheet
Contactor Catalogue
Iskra Contactor Catalogue
MS Power MSD240N16UB, Rectifier Diode 240 Amp, 1600V, 3/4" UNF 2A, Cathode stud
Features
Full blocking capability over wide temperature range
Hermetic metal case with glass insulator
Threaded stud
Applications
Power Supplies
Uncontrolled Rectifiers
Oil Cooled Circuits
Battery Chargers
Specification
MS Power Part Number
MSD240N16UB
Vrrm
1600V
Diode Configuration
Cathode Stud
IF(av) @ 100 Deg C
320 Amp
IF(av) @ 125 Deg C
240 Amp
Itsm
6 kA
VF(to)
0.85V
Tj(max)
180°C
rF
0.6mΩ
Termination Style (Tail)
8.3mm Round Lug
Termination Style (Stud)
3/4" 16 UNF
Tail Length to Stud
200mm
R th(j-c)
0.19°C/W
R th(c-h)
0.03°C/W
Weight
250g
Mounting Torque
26 Nm
Factory Pack Qty
8
Country Of Origin
China
MS Power Headquarters
Germany
Datasheet
Product Datasheet
RISHABH DMM 612 Digital Multimeter Basic Accuracy: 0.4%, AVERAGE RMS MEASUREMENT, Dual display measurement
Features
Ultra Safe Design
Average RMS Measurement
0.4% Accuracy
0.1% Resolution
0.05% Resolution
Hand Held
UL Listed
Auto Power Off
Measurement Parameters
Voltage : 100uV to 1000V AC/DC
Current : 10uA to 10Amp AC/DC
Higher Currents with various CT's
Capacitance from 1pF to 40mF
Resistance form 100mΩ to 66 MΩ
Diode measurement and continuity testing
Hold Measurement
Relative Measurement
Duty Cycle % Measurement
Temperature Measurement with Type K Thermocouple
Peak Value Measurement
Specification
RISHABH Part Number
RISHABH DMM 612
Voltage Measurement Range
0.0001 - 1000 VAC/DC Average RMS
Impedance Measurement Range
100mΩ - 66MΩ
Current Measurement Range
0.00001 - 10 Amp AC/DC Average RMS
Isolation
4.26kV
Bandwidth
DC & 20Hz to 2kHz
Battery Voltage
3VDC
Temp Measurement Range
1 - 1300 Deg C
Frequency Measurement Range
0.01Hz to 10kHz
Weight
500g
Factory Pack Qty
1
EMC
EN61326: 2002 Class B
Safety Standards
IEC 61010-1-2010 and IEC 61557, 1000V CAT III/600V CAT IV
Datasheet
Datasheet
User Manual
Crydom LND2425, Solid State Relay, Single Phase 3-32VDC Control, 75A, 24-280VAC Load, Low Noise, Low EMC/RFI
Features
• Ratings from 25A to 75 Amp @ 24-280 VAC
• SCR output for heavy industrial loads
• Zero voltage or instantaneous turn-on outputs
• UL/CSA/VDE Approved, CE Compliant to EN60950-1
• Improved SEMS screw and washer
• Redesigned housing with anti-rotation barriers
• AC & DC control types
• Direct bond copper substrate
• EMC compliant to Level 3
• Direct power lead frame
• Epoxy free design
Spec
Crydom Part Number
LND2425
Switching Type
Zero Crossing
ROHS
Yes (Details)
Control Voltage
3-32VDC
Load Current
25 Amp (rms)
Surge Capability
297 Amp (peak)
Special Feature
None
Mounting Style
Panel Mount
Load Voltage Range
24-280VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
75g
Factory Pack Qty
20
Datasheet
Product Datasheet
Please note Changes from Gen 3 to Gen 4 (current) package design here
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Fastron H71/110M & FCR-400-40R, Three Phase Proportional Phase Control Module with Heatsink, 4-20mA,0-10V,500K POT Input, 400VAC, 13 Amp Per Phase @ 40 Deg C
4-20mA,0-10V, or 500K POT Proportional Phase Control Input
Ratings from 25A to 80 Amp @ 180-280 VAC
SCR output for heavy industrial loads
Instantaneous turn-on output
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Specification
Trent part Number
H71/110M & FCR-400-40R
Switching Type
Phase Angle (Random Crossing)
Control Voltage
4-20mA,0-10V,500K POT Proportional Input
Load Current
11 Amp (rms) @ 50 Deg C, 13 Amp Per phase @ 40 Deg C
Surge Capability
500Amp (peak)
Special Feature
3 Phase Proportional Controller + SSR/3 Phase Voltage Regulator
Mounting Style
Panel Mount
Load Voltage Range
180-400VAC +10%
Max Non Repetitive Peak Voltage
600 Vp
Termination Style
Barrier Strip Screw
Dimensions
105 x 80 x 55mm
Unit Weight
1kg
Factory Pack Qty
20
Datasheet
FCR-400-40R
Product Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
Fastron ST8080A+, Refrigeration/Chiller Controller, 75x34.5mm (71x29mm Cutout), 240VAC, 2 x Relay Outputs, NTC Sensor
3-digit display suit refrigeration temperatures to 1 Degree
Drip-proof / Dust-proof IP64 (front panel only)
Each unit needs just 71 x 29mm panel space
3 minute delay protection
Automatic 15 minutes ON, 30 minutes OFF on sensor failure
Overtemperature Alarm including 10 Amp Relay, Buzzer and LED Blinking
Ultra High temperature 99 - 120 Deg C Displays "HH"
Specification
Fastron Part Number
ST8080A+
Control Output
1 x SPDT Relay 10A(Resistive) for Compressor, 1 x SPDT Relay 10A(Resitive) for Defrost
Input
NTC Probe (Included with 2 Meter wire length)
Alarm
230VAC 10 Amp Relay Contact
Mounting Style
75 x 34.5mm Panel Mount (71 x 29mm Cutout)
Supply Voltage
240VAC
Termination Style
Screw
Weight
150g
Factory Pack Qty
1
Datasheet
Download Datasheet