Fastron Electronics Fast ONE SVG 100kvar-400V-4W, 400VAC L-L Static Var Generator(SVG)/Inverter for Reactive Power Correction and Compensation, Wall Mounted
For Automatic Switching of Power Factor Correction Capacitors according to changing site conditions.
Features
Automatic Power Factor Correction up to Cos φ = 0.99
Auto rotation of same capacitors for long life
Overtemperature Alarm
Optional RS485 Comms
IEC 654-1, UL Approved
3 Year Fastron Electronics Warranty
Modular Construction for Rack or Wall Mount Installtions
Perfect for Residential Applications
Stack multiple modules for larger Power Factor Correction Requirements
Specification
Fastron Part Number
Fast ONE SVG 100kvar-400V-4W
Mounting
Wall Mounted
Function
Reactive Power Correction
Configuration
4 Wire
Nominal Voltage (Un)
400VAC Line to Line 50Hz
Switch Delay Time
Instant Correction/Inverter Based
Desired Power Factor
0.99 IND - 0.99 CAP
LCD Display Accuracy
Voltage +/-0.5%, Frequency +/-0.1%, Power +/-1% Energy Class 1
Phase Angle Error
+/- 1% at I > 3% of range
Comms
RS485 (Optional)
Termination Style
Screw
Dimensions
540x278x540mm
Weight
40kg
Certification
EN 61000-6-4:2007+A1:2011
EN 61000-6-2:2005
EN 61000-3-2:2014
EN 61000-3-3:2013+A1:2019
Factory Pack Qty
1
Material of housing
PC/ABS Unflammable, according to UL 94 V-0, & Stainless Steel Painted RAL 1013
Enclosure protection
IP21
Safety
According to EN 61 010-1, installation category III Pollution degree 2
Operating Temperature
-20...55 °C
Datasheet
Datasheet
User Manual
Fastron Electronics Fast ONE SVG 70kvar-400V-4W, 400VAC L-L Static Var Generator(SVG)/Inverter for Reactive Power Correction and Compensation, 3 Phase 4 Wire, Wall Mounted
For Automatic Switching of Power Factor Correction Capacitors according to changing site conditions.
Features
Automatic Power Factor Correction up to Cos φ = 0.99
Overtemperature Alarm
Optional RS485 Comms
IEC 654-1, UL Approved
5 Year Fastron Electronics Warranty
Modular Construction for Rack or Wall Mount Installtions
Perfect for Residential Applications
Stack multiple modules for larger Power Factor Correction Requirements
Specification
Fastron Part Number
Fast ONE SVG 70kvar-400V-4W
Mounting
Wall Mounted
Function
Reactive Power Correction
Configuration
4 Wire
Nominal Voltage (Un)
400VAC Line to Line 50Hz
Switch Delay Time
Instant Correction/Inverter Based
Desired Power Factor
0.99 IND - 0.99 CAP
LCD Display Accuracy
Voltage +/-0.5%, Frequency +/-0.1%, Power +/-1% Energy Class 1
Phase Angle Error
+/- 1% at I > 3% of range
Comms
RS485 (Optional)
Termination Style
Screw
Dimensions
486x220x610mm
Weight
60kg
Certification
EN 61000-6-4:2007+A1:2011
EN 61000-6-2:2005
EN 61000-3-2:2014
EN 61000-3-3:2013+A1:2019
Factory Pack Qty
1
Material of housing
PC/ABS Unflammable, according to UL 94 V-0, & Stainless Steel Painted RAL 1013
Enclosure protection
IP21
Safety
According to EN 61 010-1, installation category III Pollution degree 2
Operating Temperature
-20...55 °C
Datasheet
Datasheet
User Manual
Fastron GFIN/150M-DR, GFIN Heatsink for Solid State Relays, 150mm long with DIN Rail Clip 0.78 Deg C per Watt
DIN Rail or Panel Mount heat sink types
Suitable for SSR Mounting
Pre drilled for single or 3 phase SSR
Raw Finish
Specification
Fastron Part Number
GFIN/150M-DR
Mounting Type
Din Rail
Suitable SSR Rating
60/75 Amp
Dimensions (without SSR)
L:150mm x W:67mm x 88.5mm
Thermal Impedance
0.78°C/W
Unit Weight
1000g
Factory Pack Qty
10
Datasheet
Product Datasheet
Trent HS211A, Panel Mount Heat Sink, 2.7 Deg C per Watt (Heatsink Only). Suitable for 44x 57mm SSR only.
Features
Panel Mount heat sink
Suitable for SSR Mounting
Pre drilled for single or Dual SSR
Panel Mount only
Spec
Fastron Part Number
HS211A
Mounting Type
Panel Mount Only
Suitable SSR Rating
25 Amp
Dimensions (without SSR)
L:80mm x W:50mm x D:50mm
Thermal Impedance
2.7°C/W
Load Current @ 40 Deg C
21 Amp
Load Current @ 50 Deg C
17 Amp
Unit Weight
120g
Factory Pack Qty
10
Datasheet
Product Datasheet
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Fastron FDH2548ZA4 + HS211B, Panel Mount Solid State Relay, 90-280VAC Control Input, 70-480VAC Output, 21 Amps
Features
Ratings from 25A to 125 Amp @24-280 VAC
SCR output for heavy industrial loads
Zero voltage or instantaneous turn-on outputs
UL/CE/ROHS Compliant
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Panel Mount
Spec
Part Number
FDH2548ZA4 + HS211B
Switching Type
Zero Crossing
Control Voltage
90-280VAC
Load Current
21 Amp (rms) @ 40 Deg C
Surge Capability
239 Amp (peak)
Special Feature
IP20 Cover
Mounting Style
Panel Mount
Load Voltage Range
70-480VAC
Max Non Repetitive Peak Voltage
600 Vp
Termination Style
Screw Terminals
Dimensions
L:81mm x W:45mm x D:73.4mm
Unit Weight
296g
Factory Pack Qty
20
Datasheet
HS211A
FDH
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Fastron FDH2548ZD3 + HS211B, Panel Mount Solid State Relay, 3-32 Control Input, 48-480VAC Output, 21 Amp
Features
Ratings from 25A to 125 Amp @24-280 VAC
SCR output for heavy industrial loads
Zero voltage or instantaneous turn-on outputs
UL/CE/ROHS Compliant
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Panel Mount
Spec
Part Number
FDH2548ZD3 + HS211B
Switching Type
Zero Crossing
Control Voltage
3-32VDC
Load Current
21 Amp (rms) @ 40 Deg C
Surge Capability
239 Amp (peak)
Special Feature
IP20 Cover
Mounting Style
Panel Mount
Load Voltage Range
70-480VAC
Max Non Repetitive Peak Voltage
600 Vp
Termination Style
Screw Terminals
Dimensions
L:81mm x W:45mm x D:73.4mm
Unit Weight
296g
Factory Pack Qty
20
Datasheet
HS211A
FDH
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Rishabh CT 300/5 Class 0.5 10VA 62/30 (50), 300/5 Amp, Class 0.5 Current Transformer HIGH BURDEN
Features
DIN Rail Mounting Clip Included
Built In Sealable Terminal Covers
Mounting Feet Supplied
Narrow Width (45mm)
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Rishabh Part Number
CT 300/5 Class 0.5 10VA 62/30 (50)
Technology
AC Current Transformer
Ratio
300/5
Aperture Size
28mm or 10x30mm Busbar
VA Rating
30VA
Accuracy Class
Class 0.5
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Din Rail Mount
Operating Temperature Range
-30°C / 85°C
Continuous Current (max)
300Amp x 1.2
Termination Style
Screw
Unit Weight
400g
Factory Pack Qty
9
Datasheet
Product Datasheet
Iskra Doo K08M-10-240VAC Miniature Contactor 240/400/500/690V, with 240VAC Control Voltage, 4 Pole 4 x NO, Nominal Current = 15.5 Amps
Capacitor duty contactors are designed to meet the requirements of capacitor duty applications. Contactors are fitted with a block of three auxiliary contacts connected in series with six quick discharge damping resistors, two per each phase. Peak current is limited to the value within the contactor making capacity.
Features :
High contact reliability at low voltages
High electrical and mechanical endurance and high switching capacity
Four and Three-pole contactors
Optional auxiliary contacts
Ratings from 6 Amp to 1000 Amp
UL, CSA Approved
Advantages :
Saves costs of expensive replacement
Long electrical life
Reduces watt losses during “ON” condition, saves energy
High safety
No risk of dangerous voltage
Less maintenance and downtime
Standard control voltages: 24 V 50/60 Hz, 240 V 50/60 Hz, 415 V 50/60 Hz
Specification
Iskra Doo Part Number
K08M-10-240VAC
Functions
4 Pole Contactor 4 x NO
Nominal Voltage
230/400/500/690VAC @ 50/60Hz
Current Carrying Capacity as per UL
15.5 Amp Continuous @ 55 Deg C
Auxiliary Contacts
Optional Snap on
Trip Delay Time
2-10ms
Electrical Life
200,000 Ops
Operating Temperature
-25 to 40 Deg C
Mechanical Operations
10.000,000 Ops
Control Voltage
240VAC
Power Dissipation
0.36W
Approvals
UL, CSA, CE
Standards
IEC/EN 60947-4-1, AS/NZ 61009-1
Weight
200g
Enclosure Material
UL94
Factory Pack Qty
1
Datasheet
Product Datasheet
Contactor Catalogue
Iskra Contactor Catalogue
Iskra Doo K08MG-10-24VDC, AC Miniature Contactor 240/400/500/690V, with 24VDC Control Voltage, 4 Pole 4 x NO, Nominal Current = 15.5 Amps
Capacitor duty contactors are designed to meet the requirements of capacitor duty applications. Contactors are fitted with a block of three auxiliary contacts connected in series with six quick discharge damping resistors, two per each phase. Peak current is limited to the value within the contactor making capacity.
Features :
High contact reliability at low voltages
High electrical and mechanical endurance and high switching capacity
Four and Three-pole contactors
Optional auxiliary contacts
Ratings from 6 Amp to 1000 Amp
UL, CSA Approved
Advantages :
Saves costs of expensive replacement
Long electrical life
Reduces watt losses during “ON” condition, saves energy
High safety
No risk of dangerous voltage
Less maintenance and downtime
Standard control voltages: 24 V 50/60 Hz, 240 V 50/60 Hz, 415 V 50/60 Hz
Specification
Iskra Doo Part Number
K08MG-10-24VDC
Functions
4 Pole Contactor 4 x NO
Nominal Voltage
230/400/500/690VAC @ 50/60Hz
Current Carrying Capacity as per UL
15.5 Amp Continuous @ 55 Deg C
Auxiliary Contacts
Optional
Trip Delay Time
2-10ms
Electrical Life
200,000 Ops
Operating Temperature
-25 to 40 Deg C
Mechanical Operations
10.000,000 Ops
Control Voltage
24VDC
Power Dissipation
0.36W
Approvals
UL, CSA, CE
Standards
IEC/EN 60947-4-1, AS/NZ 61009-1
Weight
200g
Enclosure Material
UL94
Factory Pack Qty
1
Datasheet
Product Datasheet
Contactor Catalogue
Iskra Contactor Catalogue
Iskra Doo MOD3 3NM 315A, 3 Pole Moulded Case Circuit Breaker (MCCB) Thermal and Magnetic Release Adjustable Type 65kA 315 Amp, 400/690VAC
Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
3 Pole Disconnect
65kA Short Circuit Rating @400VAC
Suitable for Main Incoming Breaker
Standards :
IEC/EN 60898,60947-3
IP20 (IP40 Installed) IEC 61008
AS/NZ 61009-1
Specification
Iskra Doo Part Number
MOD3 3NM 315A
Functions
3 Pole MCCB
Nominal Voltage
400/690VAC @ 50/60Hz
Nominal Current Range
315 Amps RMS
Trip Delay Time
< 50ms
Rated Impulse Voltage
8kV
Operating Temperature
-25 to 50 Deg C
Mechanical Operations
20,000 Ops
Insulation Voltage
800V
Short Circuit Current
65kA @ 400VAC, 20kA @ 690VAC
Approvals
KEMA EUR, CE
Standards
IEC/EN 60898-1,IEC/EN 60947-3, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1
Weight
5.1g
Enclosure Material
UL94
Factory Pack Qty
1
Datasheet
Product Datasheet