Fastron TTH-33-DB-1, Temperature and Humidity Sensor and Transmitter, 190 x 18-19mm w/1m Cable, Can replace GEFRAN TRANSMICOR T211
2 x 4-20mA Output 2 Wire
Humidity Measurement for RH 0 to 100 %
Long Term Stability <2% RH per year
Temp Measurement for 0 to 100 Deg C Max
190 x 18mm with 1M Cable
20 Second Response Time
12-30VDC Supply 150mA max
Thin Film Capacitor and Pt100 Temp Sensing Elements
Suitable replacement for Mecatherm T211-XH-954
Specification
Fastron Part Number
TTH-33-DB-1
Sensor Type
RTD (Temperature) & Thin Film Capacitor (Humidity)
No of Wires
2
Shaft Length
190mm
Shaft Thickness
18-19mm
Approvals
CE, ROHS
Cable length
1 Meter
Temperature Range
0 to 100 Deg C
Mounting Style
Through Hole
Weight
45g
Factory Pack Qty
1
Datasheet
Datasheet
Installation Guide
Wiring Diagram
Fastron FES2151-FD-420E, Solid Core AC Current Transducer, Multirange 0-100A,150A, 200A, Self Powered, Average RMS 4-20mA Output. 1% Accuracy (FCS2151-SD-420E)
Compact and versatile current switches for detection of AC Currents, Multirange 0-10Amp, 0-20Amp, 0-50Amp via jumper, 4-20mA True RMS output
Features
Average RMS 4-20mA output
Multirange selector
Panel mounting
Eliminates insertion loss
Isolated plastic case recognised according to UL94-V0
Advantages
Highly accurate low current measurement down to 1Amp
High isolation between primary and secondary circuits
Easy installation
Applications
Fault Detection
Motor or Fan Protection
Application Domain
Energy and Automation
Specification
Fastron Part Number
FES2151-FD-420E
Technology
Solid Core Solid Core AC Current Transducer
Range
0-100Amp, 0-150Amp, 0-200Amp via jumper
Supply Voltage
Self Powered
Load Current (RMS)
1Amp to 200 Amp
Output
4-20mA Average RMS
Isolation
2kV (AC, 50Hz, 1 min)
Bandwidth
50/60Hz
Mounting Style
Panel Mount
Operating Temperature Range
-25°C / 70°C
Accuracy
1%
Termination Style
Screw Terminals
Unit Weight
200g
Certifications
UL E320368, CE, Rohs compliant
Datasheet
Product Datasheet
Installation Guide
Trent F170H0069 Series Fuse Indicator for NH Fuses
Features
To Suit trent or Bussmann Nh Fuse with Indicator
Applications
Fault Monitoring/Detection
Specification
Trent Part Number
F170H0069
Contact Rating
1 Amp 250VAC
Operating Temperature Range
-40°C / 125°C
Unit Weight
30g
Factory Pack Qty
10
Datasheet
Iskra Doo MT440-SSUDAAAAA, Multifunction Power Transducer, Class 0.5, 4 Wire, 600V 1/5/10Amp AC Input 50/60Hz, 24-300VDC or 40-276VAC Aux Input, 4 Programmable Analogue Outputs, RS485 + USB Comms
Class 0.5 (EN 60688)
USB Comms as standard
Up to 4 I/O Modules (analogue output, Multiple break point, non-linear characterstics
Automatic range of nominal current up to 12.5 A (Includes 5A/1A CT Input) and nominal voltage up to 600 V L-N
Adjustable tariff clock, display of electric energy consumption in optional currency
RMS values of currents and voltages
Measurements of active, reactive, apparent power and power factor
Measurements of energy in all 4 quadrants Average values of measurands per interval
Certified ship version available
The Power Transducer is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals.
Features :
Measurement of instantaneous values of more than 50 quantities (U, I, P, Q, S, PF, PA, f, f, MD, etc.).
Accuracy class 0.5
32 Adjustable Alarms
Input frequency 50/60 Hz or 400 Hz
RS 232/RS485 communication up to 115,200 bit/s (Optional) or USB communication as standard
MODBUS RTU communication protocol
Up to 4 inputs or outputs (pulse outputs, alarm outputs, tariff inputs)
Universal Supply 24-300VDC or 40-276VAC
Automatic range of nominal current up to 12.5 A and nominal voltage up to 600 V
User-friendly PC MiQen software
Specification
Iskra Doo Part Number
MT440-SSUDAAAAA
Functions
3 Phase Power Transducer
Supply Voltage
24-300VDC or 40-276VAC
Nominal Measurement Range
600V L-N, 1/5/10 Amp
Maximum Measurement Range
600V L-N, 12.5 Amp
Alarm
N/A
Tariff Input
N/A
Output
4 x Analogue
Accuracy
Class 0.5 (I,U,F,PF,θ,THD) Class 1(Active), Class 2 (Reactive)
Battery Backup
N/A
Real Time Clock
1min/month (30ppm)
Isolation
3.5kV
Comms
USB (standard) RS485 2400-115200 b/s (RS232 Optional)
Weight
370g
Enclosure Material
UL94,
Factory Pack Qty
1
EU Directives
EN61010, EN60688,EN61326-1,60529,60068-2-1/-2/-6/-27/-30
Safety
Protection Class II
600V rms, installation category II
300V rms, installation category III
Pollution Degree 2 in compliance with SIST EN 61010-1:2002
Enclosure Material
PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0
Enclosure Protection
IP20
Shock Withstand
300g 8ms Pulse . 6 Shocks in each of 3 axes
Vibration Withstand
0.7g, 3...100Hz, 1oct/min 10 cycles in each of three axes
Operating Temperature
-20 →+70 °C
Datasheet
Product Datasheet
Software
MiQen Setting Software
MIPACK Programmer
Fastron TTH-33-SA1-1, Temperature and Humidity Sensor and Transmitter, 150 x 6mm w/1m Cable
2 x 4-20mA Output 2 Wire
Humidity Measurement for RH 0 to 100 %
Long Term Stability <2% RH per year
Temp Measurement for 0 to 100 Deg C Max
150 x 6mm with 1M Cable
20 Second Response Time
12-30VDC Supply 150mA max
Thin Film Capacitor and Pt100 Temp Sensing Elements
Suitable replacement for Mecatherm T211-XH-954
Specification
Fastron Part Number
TTH-33-SA1-1
Sensor Type
RTD (Temperature) & Thin Film Capacitor (Humidity)
No of Wires
2
Shaft Length
150mm
Shaft Thickness
6mm
Approvals
CE, ROHS
Cable length
1 Meter
Temperature Range
0 to 100 Deg C
Mounting Style
Through Hole
Weight
45g
Factory Pack Qty
1
Datasheet
Datasheet
Installation Guide
Wiring Diagram
MS Power MSD403R18UB, Rectifier Diode 400 Amp, 1800V, 3/4"UNF 16 2A, Anode stud
Features
Full blocking capability over wide temperature range
Hermetic metal case with glass insulator
Threaded stud
Applications
Power Supplies
Uncontrolled Rectifiers
Oil Cooled Circuits
Battery Chargers
Specification
MS Power Part Number
MSD403R18UB
Vrrm
1800V
Diode Configuration
Anode Stud
IF(av) @ 100 Deg C
480 Amp
IF(av) @ 120 Deg C
400 Amp
Itsm
9.2 kA
VF(to)
0.85V
Tj(max)
180°C
rF
0.51mΩ
Termination Style (Tail)
10.6mm Round Lug
Termination Style (Stud)
3/4' UNF 16 2A
Tail Length to Stud
200mm
R th(j-c)
0.13°C/W
R th(c-h)
0.04°C/W
Weight
250g
Mounting Torque
26 Nm
Factory Pack Qty
8
Country Of Origin
China
MS Power Headquarters
Germany
Datasheet
Product Datasheet
FT500160P, 5000/5 Amp Split Core CT, Class 1 15VA Series Current Transformer
Features
Quick Release Split Core System
Built In Sealable Terminal Covers
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Electronics Part Number
FT500160P
Technology
Split Core AC Current Transformer
Ratio
5000/5
Aperture Size
80 x 160mm
VA Rating
15VA
Accuracy Class
Class 0.5
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-10°C / 50°C
Continuous Current (max)
4000Amp x 1.2
Termination Style
Screw
Approvals
UL, CE
Unit Weight
1150g
Factory Pack Qty
1
Datasheet
Product Datasheet
Installation Guide
Fastron Electronics FESCT-3000-3000, 3000Amp 0.333V Class 1 Measurement Split Core CT's, 1M Flying Leads, 76x127mm Aperture
Features
Quick Release Split Core System
1m Flying Leads
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.60/3kV
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Electronics Part Number
FESCT-3000-3000
Technology
Split Core AC Current Transformer
Ratio
3000/0.333V
Aperture Size
76x127mm
VA Rating
N/A
Accuracy Class
Class 1
Output
0.333VAC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 55°C
Continuous Current (max)
3000Amp x 1.2
Termination Style
Terminals
Unit Weight
3000g
Factory Pack Qty
9
Datasheet
Product Datasheet
Application Notes
Installation Guide
Northern Design Power Rail IP 350-M2 Three Phase Power Meter
5 Amp CT Input
Modbus TCP communication
True RMS values of currents and voltages
Power Quality Measurements
The meter is intended for measuring, and monitoring single-phase or electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, Hours Run, Peak Demand etc to the 30th Harmonic) from the measured signals.
Features :
Accuracy class 1
Measurement of Active and Reactive Power
Modbus TCP communication
Pulse output as standard
Graphic LCD with illumination
Specification
Northern Design Part Number
Power RailIP 350-M2
Functions
Three Phase Energy Meter
Supply Voltage
230V L-N, 5 Amp +/-15% < 5VA
Nominal Measurement Range
415V L-L 230V L-N, 5 Amp +/-15%
Maximum Measurement Range
480V L-L 230V L-N, 5 Amp +/-15%
Nominal Current Input
5 Amp AC
Pulse Output
3 x NO Voltage Free Contacts 100mA @ 100VAC/DC
Accuracy
Class 1 (I,U,F,PF,) Class 2 (Reactive)
Mounting
Din Rail
Real Time Clock
1min/month (30ppm)
Internal Memory
N/A
Dimensions
106mm x 90mm x 58mm (6 modules wide)
Isolation
3.5kV
Comms
Modbus TCP Ethernet
Weight
250g
Certification
EN 61010-1 Installation Category III
Factory Pack Qty
1
Enclosure Material
Noryl with fire protection to UL94-V-O. Self extinguishing
Enclosure Size
DIN 42880 6 Modules
Operating Temperature
-20 →+70 °C
Datasheet
Product Datasheet
Product Manual
Product Comms Manual
Option Links
Application Notes
CT Cable Losses
Meter Accuracy at Low Current
Current Input Isolation
Temperature Sensor Plug Round, Wire Fitting for use with Thermocouple
Rated for 220 Deg C
For Thermocouple
Suitable for internal oven use
Datasheet