Search results for "tg탤 banonpi 신용불량자소액작업대출 바넌피유심내구제 군산시기초수급자비대면소액대출 kt소액급전내구제대출 휴대폰내구제비대면"
-
F923 AC Series Current Transducer with Adjustable High and Low Solid State Relay Alarm
F923 Series AC Current Transducer with Process Outputs & High and Low Sold State Alarm Features Isolated measurement of AC currents using internal Hall effect transducer. Incorporates an integrated input level display and power supply. Wide measurement range available Choice of standard outputs Wide range isolated DC input supply DIN Rail mounting Signal Conditioned AC measurement output On board bar graph display User adjustable zero offset and span controls Zero insertion loss in current measurement path Earth leakage via differential Ipn for nominal Input ‘01’ Applications Process control Transportation Petrochemical Industrial Earth Leakage Energy Monitoring/Measurement Automation Delivery Delivery in 3-5 days for small qty. Otherwise 4-6 weeks Specification Oztherm Part Number F923-X-XX-AC-XX Functions Single Phase AC Current Transducer Supply Voltage 9-36VDC Nominal Measurement Range 0-8 Amp (Sensor dependant) Maximum Measurement Range 8 Amp Alarm C/O Relay 2Amp @ 40VDC, 2Amp @ 60VAC Response Time 250mS Accuracy @ 25 Deg C Class 1 Bandwidth DC - 1kHz linearity < 0.15% Isolation 2.5kV Comms N/A Weight 250g Enclosure Size 79 x 60 x 85mm Factory Pack Qty 1 EU Directives N/A Safety Protection Class II 600V rms, installation category II 300V rms, installation category III Pollution Degree 2 in compliance with SIST EN 61010-1:2002 Enclosure Material Polyamide non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP40 Shock Withstand 300g 8ms Pulse . 6 Shocks in each of 3 axes Vibration Withstand 0.7g, 3...100Hz, 1oct/min 10 cycles in each of three axes Operating Temperature -20 →+70 °C Datasheet Product Datasheet
$552.00 - $595.00
-
TC Cable 1M PVC Laid Flat, Per Meter, ANSI Standard
Thermocouple Cable per Meter, PVC Laid Flat 7/0.2mm, ANSI Standard Features CE, ANSI, ROHS Approved Colour Codes Datasheet Thermocouple Cable Brochure
$2.30
$2.71 inclGST -
Sprint 350 3P4W 100 Amp RS232, Three Phase Revenue Grade Meter for Small Commercial Applications, 100 Amp Direct Connect, RS232 Comms, NMI NMI 14/2/84
Heavy Item - No Free ShippingSecure Sprint 350 3P4W 100 Amp RS232, Three Phase Revenue Grade Meter for Small Commercial Applications, 100 Amp Direct Connect, RS232 Comms, NMI NMI 14/2/84 Three Phase Revenue Grade Meter for small commercial applications Usage The meter is intended for measuring, monitoring three-phase electrical power network in residental, or small commercial applications for billing purposes. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals. Specification Secure Part Number Sprint 350 3P4W 100 Amp Functions Commercial Billing Meter with LCD Display Nominal Measurement/Supply Range 3 x 100/240/400VAC, 10/100 Amp 50Hz Maximum Measurement Range 460VAC, 10/100 Amp 50Hz 4 Quadrant Measurement Import/Export Tariff Input N/A Accuracy Class 1 Comms RS232 (Optional 4G available) Weight 2000g Certification CIEC/AS 62052-11, IEC/AS 62053-21, NMI M6-1 Factory Pack Qty 1 Safety IP53 Enclosure Material Engineering Plastic Optional RTC,Load Profile, RS485 Interface, Outputs Operating Temperature -40 →+80 °C Datasheet Datasheet IGC meters MT860 MT830/831 ICG Meter Shortform
-
FP060080P, 600/5 Amp Split Core CT, Class 0.5 2.5VA Clip On AC Current Transformer, 50 x 80mm Aperture, Dimension 145 x 159 x 37mm
Free Aus Post Shipping for $300 SpendFP060080P, 600/5 Amp Split Core CT, Class 1 3VA Series Clip On Current Transformer Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number FP060080P Technology Split Core AC Clip On Current Transformer Ratio 600/5 Aperture Size 50 x 80mm VA Rating 2.5VA Accuracy Class Class 0.5 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -10°C / 50°C Continuous Current (max) 600Amp x 1.2 Termination Style Screw Approvals CE Unit Weight 1150g Factory Pack Qty 1 Datasheet Product Datasheet Installation Guide
-
ART-B22-D125-SP3 + AI-PMUL, Single Phase Rogowski Coil Set, Class 1, User Selectable 0.333v, 0.166v, True RMS 4-20mA, 0-20mA, 0-10V, 0-5V Outputs, Sensitivity, and Measurement Range, 17.5cm Diameter
Free Aus Post Shipping for $300 SpendLEM ART-B22-D125-SP3 + AI-PMUL, Single Phase Rogowski Coil Set, Class 1, User Selectable 0.333v, 0.166v, True RMS 4-20mA, 0-20mA, 0-10V, 0-5V Outputs, Sensitivity, and Measurement Range, 12.5cm Diameter The universal Rogowski coil integrator AI-PMUL complements LEM’s flexible clip-around coil ART and ARU range. The design is based on digital processing to give combined dynamic range, accuracy and versatility of use. It offers a wide range of output signals both RMS and instantaneous. AI-PMUL is DIN rail mounted and can be stacked for multiphase application without spacing thanks to its low power dissipation. Input signal Accuracy Class 1 (IEC 61869-2) [1]. Linearity error ≤ 0.10 %. Protection degree IP2X. 35 mm DIN rail mounted. Push-in terminals. 4 selectable true RMS output signals: 0…20 mA, 4…20 mA, 0…5 V, 0…10 V. 2 selectable instantaneous output signals: 225 mV, 333 mV. 6 selectable sensitivities depending on Rogowski coil: 22.5, 70, 80, 85, 100, 120 mV/kA at 50 Hz. 12 selectable ranges: 100, 200, 300, 400, 500, 600, 800, 1000, 1500, 2000, 4000, 5000 A. Ambient operating temperature −25...+70 °C. Advantages Compact design for DIN rail assembly High accuracy Class 1 (IEC 61869-2) Setup by user via Select / Edit buttons Clear status indication via bi-color led Applications MV/LV substations on LV side: Transformer Condition Monitoring Power metering: current measurement for active power calculation Building sub-metering: energy efficiency monitoring, consumption analysis and cost allocation Power quality monitoring: electrical loads and distribution system equipment Fault Detection, Isolation and Repair (FDIR): isolate the site of the fault Remote Terminal Units (RTU) Phasor Measurement Units (PMU) Standards IEC 61010-1: 2010 UL EMC: IEC 61326-1:2012 Options Cross Power Plug-in: side contacts to stack up to 3 Integrator modules and use only one power supply. Specification LEM Part Number AI-PMUL + ART-B22-D125-SP3 Function Single Phase AC Current Measurement Measuring Range Selectable 5000,4000,2000,1500,1000,800,600,500,400,300,200,100Amp Sensitivity Selectable 22.5,70,80,85,100,120mV/kA @ 50 Hz Output Selectable; Signal Conditioned True RMS 0-20mA, True RMS 4-20mA, True RMS 5V, True RMS 10V or 225mV, 333mV Direct Output (1 Amp output coming soon) Frequency Measuring Range 50-1500Hz (15th Harmonic) Operating Voltage 10-32VDC Accuracy 1% from 25 to 5000 Amp Current Consumption 100mA (max) Dimensions 100mm x 78mm x 15mm (Integrator), 12.5cm Diameter (Coils) Mounting Din Rail Mount Integrator to Coil cable 3M Twisted and Screened Integrator to Meter cable User Supplied Shielded cable 1.5mm sqr, up to 6m long Operating Temperature -25°C - 70°C Storage Temperature -45°C to 80°C Isolation (50Hz, 1 min) 1.5kV True RMS Response Time 160-190ms Termination Style Push-in for 1.5mm sqr wire Weight 58g Factory Pack Qty 1 Certifications UL, ROHS Datasheet AI-PMUL Datasheet ART Series Datasheet Application Notes User Notice 1) The Rogowski coil can measure any primary current as there is no saturation effect. 2) Not tested given that in the worst case (load = 0 Ohm i.e. short circuit on the output) the peak dissipated power remains low (< 2 Watts) 3) Frequency bandwidth and phase shift modelling schematic can be provided on request. 4) Referring to the main phase offset of 90 ° (a Rogowski coil is a derivative current transducer) 5) Considering a primary conductor of at least ⌀ 15 mm, perpendicular and in contact with the Rogowski coil. 6) Considering an external conductor of at least ⌀ 15 mm the same current level than internal conductor, perpendicular and in contact with the Rogowski coil.
-
THST6416D-24-850-RS485, Split Core Bipolar Hall Effect DC Current Transducer, +/-850 Amp DC, RS485 Modbus RTU output, 64x16mm aperture, 24VDC supply
Free Aus Post Shipping for $300 SpendTHST6416D-24-850-RS485, Split Core Bipolar Hall Effect DC Current Transducer, +/-850 Amp DC, RS485 Modbus RTU output, 64x16mm aperture, 24VDC supply Compact and versatile Split Core Bipolar DC current sensor, +/-850 Amp DC, Modbus RS485output Features Modbus RTU (RS485)output 64 x 16mm Aperture Split Core DC Measurement Busbar, or DIN Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Mount Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number THST6416D-24-850-RS485 Technology DC Hall Effect Current Transducer with Processoutput ROHS Yes Supply Voltage 24VDC Nominal Current (DC) 0-850 Amp Response Time < 200mS Output RS485 Modbus RTU Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Screw Unit Weight 500g Factory Pack Qty 6 Datasheet Product Datasheet
-
SM61IoT-2100M0, Datalogger with Internal Web page, Universal 20-40VAC, 20-60VDC Supply, 2 Relays, Modbus TCP/RTU,MQTT,HTTP/TCP/UDP/FTP/RS485/RS232/USB Comms
Free Aus Post Shipping for $300 SpendLumel SM61IoT-2100M0, Datalogger with Internal Web page, Universal 20-40VAC, 20-60VDC Supply, 2 Relays, Modbus, Email Alarm Feature TCP/RTU,MQTT,HTTP/TCP/UDP/FTP/RS485/RS232/USB Comms MQTT protocol for IoT Applications Internal Web page 1GB Flash Memory (Optional 8GB) USB/RS232/RS485/Ethernet Comms as standard Modbus TCP/RTU,MQTT,HTTP/TCP/UDP/FTP Protocols Universal 20-40VAC, 20-60VDC Supply Relays Alarms (Optional Digital Alarms) Email Alarms Features : Built in Web Page and FTP Server 2 RS485 Ports or 1 x RS485 and 1 x RS232 Ports 2 Relay Alarms Real Time Clock Simultaneous Interrogation of Data Password Data Access Email Alarm Function Specification Lumel Part Number SM61IoT-2100M0 Functions Communication Datalogger and Alarm Unit Supply Voltage 20-40VAC, 20-60VDC Protocols TCP/RTU,MQTT,HTTP/TCP/UDP/FTP Communication Ports RS485/RS232,RS485,USB,Ethernet RS485/RS232 Baud Rate 1200,2400,4800,9600,19200,38400,57600,115200 bit/s USB Baud Rate 115200 bit/s Ethernet Baud Rate 10,100 Mbit/s Real Time Clock 1min/month (30ppm) Isolation 3.5kV Weight 250g Language English/Polish Market Factory Pack Qty 1 EU Directives EN61000, EN61010 Safety Protection Class II Enclosure Material PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP20 Operating Temperature -20 →+70 °C Datasheet Product Datasheet User Manual
-
THST6416D-24-2000-RS485, Split Core Bipolar Hall Effect DC Current Transducer, +/-2000 Amp DC, RS485 Modbus RTU output, 64x16mm aperture, 24VDC supply
Free Aus Post Shipping for $300 SpendTHST6416D-24-2000-RS485, Split Core Bipolar Hall Effect DC Current Transducer, +/-2000 Amp DC, RS485 Modbus RTU output, 64x16mm aperture, 24VDC supply Compact and versatile Split Core Bipolar DC current sensor, +/-1000 Amp DC, Modbus RS485output Features Modbus RTU (RS485)output 64 x 16mm Aperture Split Core DC Measurement Busbar, or DIN Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Mount Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number THST6416D-24-2000-RS485 Technology DC Hall Effect Current Transducer with Processoutput ROHS Yes Supply Voltage 24VDC Nominal Current (DC) 0-2000 Amp Response Time < 200mS Output RS485 Modbus RTU Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Screw Unit Weight 500g Factory Pack Qty 6 Datasheet Product Datasheet
-
HAZ 20000-SBI, O/L Current Transducer, 20000 Amp, +/-15VDC supply, +/-20mA Output
Free Aus Post Shipping for $300 SpendLEM HAZ 20000-SBI, O/L Current Transducer, 20000 Amp, +/-15VDC supply, +/-20mA Output For the electronic measurement of currents: DC, AC, pulsed, mixed, with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit). Features Instantaneous output version +/-10V, +/-20mA True RMS output versions 4-20mA, 0-10V putput Hall effect measuring principle Galvanic isolation between primary and secondary circuit Instantaneous voltage output Isolation voltage 17kV Rms /50 Hz /1min Low power consumption Package in PBT meeting UL 94-V0 Instantaneous voltage output Advantages Easy installation Small size and space savings Only one design for wide Ratings range High immunity against external interference Applications Battery supplied applications Uninterruptible Power Supplies (UPS) Power supplies for welding and telecom applications Application domain Industrial Traction Specification LEM Part Number HAZ 20000-SBI Technology Open Loop Hall Effect ROHS Yes Supply Voltage +/- 15VDC Load Current (RMS + DC) 20000 Amp Overload Rating 30000 At Output +/-20 mA Instantaneous Isolation 17kV (AC, 50Hz, 1 min) Bandwidth DC-3kHz Mounting Style Busbar Mount Operating Temperature Range -25°C / 85°C Accuracy 1% Termination Style F2023A (FUJICON) Unit Weight 6kg Factory Pack Qty 2 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition 2026 Application Guide
-
THST18244D-24-1000-RS485, Split Core Bipolar Hall Effect DC Current Transducer, +/-1000Amp DC, +24VDC Supply, 182 x 44 Square aperture, RS485 Modbus RTU Measurement Only
Free Aus Post Shipping for $300 SpendTHST18244D-24-1000-RS485, Split Core Bipolar Hall Effect DC Current Transducer, 1000Amp DC, +24VDC Supply, 182 x 44 Square aperture, RS485 Modbus RTU Measurement Only Compact and versatile Split Core Bipolar DC current sensor, +/-1000 Amp DC, Modbus RS485output Features Modbus RTU (RS485)output 182 x 44mm Aperture Split Core DC Measurement Busbar, or DIN Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Mount Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number THST18244D-24-1000-RS485 Technology DC Hall Effect Current Transducer with Processoutput ROHS Yes Supply Voltage 24VDC Nominal Current (DC) 0-1000 Amp Response Time < 200mS Output RS485 Modbus RTU Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Screw Unit Weight 500g Factory Pack Qty 6 Datasheet Product Datasheet
-
THST18244D-24-2000-RS485, Split Core Bipolar Hall Effect DC Current Transducer, +/-2000Amp DC, +24VDC Supply, 182 x 44 Square aperture, RS485 Modbus RTU Measurement Only
Free Aus Post Shipping for $300 SpendTHST18244D-24-2000-RS485, Split Core Bipolar Hall Effect DC Current Transducer, 2000Amp DC, +24VDC Supply, 182 x 44 Square aperture, RS485 Modbus RTU Measurement Only Compact and versatile Split Core Bipolar DC current sensor, +/-2000 Amp DC, Modbus RS485output Features Modbus RTU (RS485)output 182 x 44mm Aperture Split Core DC Measurement Busbar, or DIN Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Mount Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number THST18244D-24-2000-RS485 Technology DC Hall Effect Current Transducer with Processoutput ROHS Yes Supply Voltage 24VDC Nominal Current (DC) 0-2000 Amp Response Time < 200mS Output RS485 Modbus RTU Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Screw Unit Weight 3kg Factory Pack Qty 6 Datasheet Product Datasheet
-
HAZ 10000-SBI, O/L Current Transducer, 10000 Amp, +/-20mA Instant Output, +/-15VDC supply
Free Aus Post Shipping for $300 SpendLEM HAZ 10000-SBI, O/L Current Transducer, 10000 Amp, +/-20mA Instant Output, +/-15VDC supply For the electronic measurement of currents: DC, AC, pulsed, mixed, with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit). Features Instantaneous output version +/-10V, +/-20mA True RMS output versions 4-20mA, 0-10V putput Hall effect measuring principle Galvanic isolation between primary and secondary circuit Instantaneous voltage output Isolation voltage 17kV Rms /50 Hz /1min Low power consumption Package in PBT meeting UL 94-V0 Instantaneous voltage output Advantages Easy installation Small size and space savings Only one design for wide Ratings range High immunity against external interference Applications Battery supplied applications Uninterruptible Power Supplies (UPS) Power supplies for welding and telecom applications Application domain Industrial Traction Specification LEM Part Number HAZ 10000-SBI Technology Open Loop Hall Effect ROHS Yes Supply Voltage +/- 15VDC Load Current (RMS + DC) 12000 Amp Overload Rating 30000 At Output +/-20 mA Instantaneous Isolation 17kV (AC, 50Hz, 1 min) Bandwidth DC-3kHz Mounting Style Busbar Mount Operating Temperature Range -25°C / 85°C Accuracy 1% Termination Style F2023A (FUJICON) Unit Weight 6kg Factory Pack Qty 2 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition 2026 Application Guide