Temperature Sensor Socket Round, Wire Fitting for use with Thermocouple
Rated for 220 Deg C
For Type Thermocouple
Panel Mount
Datasheet
Thermocouple Connectors Brochure
Temperature Sensor K Socket Flat Pins, Wire Fitting for use with Thermocouple
Rated for 220 Deg C
For Type Thermocouple
Panel Mount
Datasheet
Thermocouple Connectors Brochure
Temperature Sensor Plug Flat, Wire Fitting for use with Thermocouple
Rated for 220 Deg C
For Thermocouple
Suitable for internal oven use
Datasheet
Thermocouple Connectors Brochure
Schurter 3-122-073, V-Lock IEC Appliance Plug C13/F, Black, for 3 x 1.5m sqr/14AWG Maximum wire size 8.3mm Type
Features
Panel Mount : Snap-in Mounting from Front Side
Appliance Inlet C13/F Plug acc to IEC 60320-1
Screw On Mounting
70 °C pin Temperature
Characteristics
UL 60320-1, CSA C22.2 no. 60320-1 (for hot conditions) pin-temperature 120 °C, 10A, Protection Class I
Other Pin versions available on request
Types for enhanced glow wire test requirements acc. IEC 60695-2- 12 and -13 for the use in unattended household equipment acc. IEC 60335-1
Specification
Schurter Part Number
3-122-073
Rated Voltage
250V
Rated Current
10A (CE) 15A (UL/CSA)
Operating Temperature
-25°C to 70°C
Mounting
Wire Screw Mount
Material
Thermoplastic, black, UL 94V-0
Termination Style
C13 Female to Screw Terminal
Weight
40g
Factory Pack Qty
1
Protection Class
From front side IP30 acc. to IEC 60529
Isolation
2kV
VDE/UL/CSA/CE/ROHS
Yes
Datasheet
Product Datasheet
Fastron FES521-FP-420E, Split Core AC Current Transducer, Multirange 10A, 20A, 50A, Average RMS 4-20mA Output. 1% Accuracy (FCS521-FP-420E)
Compact and versatile current switches for detection of AC Currents, Multirange 0-10Amp, 0-20Amp, 0-50Amp via jumper, 4-20mA True RMS output
Features
True RMS 4-20mA output
Multirange selector
Panel mounting
Eliminates insertion loss
Isolated plastic case recognised according to UL94-V0
Advantages
Highly accurate low current measurement down to 1Amp
High isolation between primary and secondary circuits
Easy installation
Applications
Fault Detection
Motor or Fan Protection
Application Domain
Energy and Automation
Specification
Fastron Part Number
FES521-FP-420E
Technology
Split Core AC Current Transducer
Range
Selectable 0-10Amp, 0-20Amp, 0-50Amp via jumper
Supply Voltage
Self Powered
Load Current (RMS)
1Amp to 50 Amp
Output
4-20mA Average RMS
Isolation
2kV (AC, 50Hz, 1 min)
Bandwidth
50/60Hz
Mounting Style
Panel Mount
Operating Temperature Range
-25°C / 70°C
Accuracy
1%
Termination Style
Screw Terminals
Unit Weight
200g
Certifications
UL E320368, CE, Rohs compliant
Datasheet
Product Datasheet
Installation Guide
Schurter 1241.1104.7091 MCS switch 18mm Round Panel Mount Yellow
Description
Momentary action switch available with custom lettering, and in different colours
Snap in Assembly
Pin connections for Soldering
Characteristics
PES Thermoplastic Housing PBT Thermoplastic Bezel
Contacts material CuZn37 3 um Ni 2um Au; CuZn37 2.5 um Ag
Wide range of colours, lettering - Switching voltage max. 48 VDC, switching current max. 125 mA
Varnished Version Colour adjustments to customer housings possible, as standard
13/14mm Aperture Round, and Square versions available.
Specification
Schurter Part Number
1241.1104.7091
Switching Type
Momentary
Switch Size
Square 4 x 18mm (13 x 18mm total)
Switch Colour
Yellow
Housing Colour
Black
Nominal Voltage
5-48VDC
Rated Power
0.72W
Rated Actuations
1-5 Million
Nominal Current (AC/DC)
125mA
Contact Resistance ON/OFF
<50m Ohm/ >100 M Ohm
Dimensions
ø18 x 13mm
Operating Temperature Range
-25°C / 60°C
Termination
Solder Terminals
IP Protection Rating
65 (Snap in)
Mounting
Snap in
Unit Weight
40g
Factory Pack Qty
10
Datasheet
Product Datasheet
Fastron Electronics SCT-F36-300-5A, 5 Amp, 300Amp measurement Split Core CT's
Features
Quick Release Split Core System
Cable Mount
5 Amp Output
Self Powered
Rated System Voltage 0.60/3kV
0.9M Flying Leads
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
SCT-F36-300-5A
Technology
Split Core AC Current Transformer
Ratio
300/5 Amp
Aperture Size
ø 35 mm
VA Rating
N/A
Accuracy Class
Class 1
Output
5 Amp (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
300Amp x 1.2
Termination Style
0.9M Flying leads
Unit Weight
400g
Factory Pack Qty
9
Datasheet
Product Datasheet
Stocked Split Core CT's Listing
Application Notes
Installation Guide
Types of Current Transformers - Blog
Cable Losses and CT's
High Accuracy or High Burden Requirements for CT's
GFIN/100M-DR + PMP2450WP DIN Mount, Proportional Controller, 170-280VAC 50 Amp @ 40 Deg C, Selection for Burst/Phase Angle, 4-20mA, 0-10V, 0-5V Input, Din Rail Mount, with Overvoltage Protection
Selectable Proportional Phase or Burst Control Input
Ratings from 25A to 90 Amp @ 170-600 VAC
SCR output for heavy industrial loads
Zero voltage or Instantaneous turn-on outputs
UL/CE/ROHS Compliant
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Specification
Crydom Part Number
GFIN/100M-DR + PMP2450WP
Switching Type
Phase Angle or Burst (Selectable)
ROHS/CE/UL
Yes
Control Voltage
0 - 10V/0 - 5V/4 - 20mA Proportional Input (Selectable)
Note Requires DC Power Supply for 0-5V/0-10V input modes
Load Current
50 Amp (rms)
Surge Capability
597 Amp (peak)
Special Feature
Proportional Controller + SSR + Overvvoltage Protection
Mounting Style
Panel Mount
Load Voltage Range
170-280VAC
Dielectric Strength
4kV
Termination Style
Terminal Plug
Unit Weight
1000g
Factory Pack Qty
20
Datasheet
PMP24 Series Datasheet
PMP24 Installation/Wiring Guide
GFIN
Equivalent Parts
Contact Us for Possible Replacement
LEM ART-B22-D70-SP3 + AI-PMUL Single Phase Rogowski Coil Set, Class 1, User Selectable 0.333v, 0.166v, True RMS 4-20mA, 0-20mA, 0-10V, 0-5V Outputs, Sensitivity, and Measurement Range, 7cm Diameter
The universal Rogowski coil integrator AI-PMUL complements LEM’s flexible clip-around coil ART and ARU range. The design is based on digital processing to give combined dynamic range, accuracy and versatility of use. It offers a wide range of output signals both RMS and instantaneous. AI-PMUL is DIN rail mounted and can be stacked for multiphase application without spacing thanks to its low power dissipation.
Input signal
Accuracy Class 1 (IEC 61869-2) [1].
Linearity error ≤ 0.10 %. Protection degree IP2X.
35 mm DIN rail mounted.
Push-in terminals.
4 selectable true RMS output signals: 0…20 mA, 4…20 mA, 0…5 V, 0…10 V.
2 selectable instantaneous output signals: 225 mV, 333 mV.
6 selectable sensitivities depending on Rogowski coil: 22.5, 70, 80, 85, 100, 120 mV/kA at 50 Hz.
12 selectable ranges: 100, 200, 300, 400, 500, 600, 800, 1000, 1500, 2000, 4000, 5000 A.
Ambient operating temperature −25...+70 °C.
Advantages
Compact design for DIN rail assembly
High accuracy Class 1 (IEC 61869-2)
Setup by user via Select / Edit buttons
Clear status indication via bi-color led
Applications
MV/LV substations on LV side: Transformer Condition Monitoring
Power metering: current measurement for active power calculation
Building sub-metering: energy efficiency monitoring, consumption analysis and cost allocation
Power quality monitoring: electrical loads and distribution system equipment
Fault Detection, Isolation and Repair (FDIR): isolate the site of the fault
Remote Terminal Units (RTU)
Phasor Measurement Units (PMU)
Standards
IEC 61010-1: 2010
UL
EMC: IEC 61326-1:2012
Included Options
Cross Power Plug-in: side contacts to stack up to 3 Integrator modules and use only one power supply.
Specification
LEM Part Number
ART-B22-D70-SP3 + AI-PMUL
Function
Single Phase AC Current Measurement
Measuring Range
Selectable 5000,4000,2000,1500,1000,800,600,500,400,300,200,100Amp
Sensitivity
Selectable 22.5,70,80,85,100,120mV/kA @ 50 Hz
Output
Selectable; Signal Conditioned True RMS 0-20mA, True RMS 4-20mA, True RMS 5V, True RMS 10V or 225mV, 333mV Direct Output (1 Amp output coming soon)
Frequency Measuring Range
50-1500Hz (15th Harmonic)
Operating Voltage
10-32VDC
Accuracy
1% from 25 to 5000 Amp
Current Consumption
100mA (max)
Dimensions
100mm x 78mm x 15mm (Integrator), 7cm Diameter (Coils)
Mounting
Din Rail Mount
Integrator to Coil cable
3M Twisted and Screened
Integrator to Meter cable
User Supplied Shielded cable 1.5mm sqr, up to 6m long
Operating Temperature
-25°C - 70°C
Storage Temperature
-45°C to 80°C
Isolation (50Hz, 1 min)
1.5kV
True RMS Response Time
160-190ms
Termination Style
Push-in for 1.5mm sqr wire
Weight
58g
Factory Pack Qty
1
Certifications
UL, ROHS
Datasheet
AI-PMUL Datasheet
ART Series Datasheet
Applicaton Notes
User Notice
1) The Rogowski coil can measure any primary current as there is no saturation effect.
2) Not tested given that in the worst case (load = 0 Ohm i.e. short circuit on the output) the peak dissipated power remains low (< 2 Watts)
3) Frequency bandwidth and phase shift modelling schematic can be provided on request.
4) Referring to the main phase offset of 90 ° (a Rogowski coil is a derivative current transducer)
5) Considering a primary conductor of at least ⌀ 15 mm, perpendicular and in contact with the Rogowski coil.
6) Considering an external conductor of at least ⌀ 15 mm the same current level than internal conductor, perpendicular and in contact with the Rogowski coil.
LEM CAB 500-C/SP5, Fluxgate Automotive Battery Sensor, +/-500Amp Measurement, 12VDC Supply, 24.2mm ø Aperture, Accuracy = 0.5%, Unlimited Overcurrent Capability, Cable Mount, Programmable Can Bus ID
Features
Transducer using Fluxgate technology
+/-530Amp Measurement
12VDC Supply
Accuracy = 0.5%
Wide Temperature Range -40 to 105°C
Unlimited Overcurrent Capability
Panel Mount
CAN Bus ID (Programmable)
Nanocrystalline Magnetic Core
Advantages
No Offset Error
High Accuracy
Low Linearity Error
Full Galvanic Seperation
Austomotive Applications
Hybrid and Electric Vehicle Battery Packs
Conventional Lead Acid Batteries
Accurate measurement for battery management applications
Specification
LEM Part Number
CAB 500-C/SP5
Technology
DC Hall Effect
Protection Class
See Datasheet
Supply Voltage
8 - 16VDC
Load Current (RMS)
-530 to 530 Amp
Output
CAN.C Bus (500kbps) ver 2.0A/B
CAN Bus ID
Programmable
Electrostatic Discharge Voltage
4kV at pinout
Isolation
2.5kV (50Hz, 1min)
Aperture
ø 24.2mm
Mounting Style
Panel Mount
Operating Temperature Range
-40 to 105°C
Accuracy
0.5%
Termination Style
Tyco=AMP P/N:1 473672-1
Unit Weight
67g
Factory Pack Qty
1
Datasheet
Product Datasheet