Rish Xmer 86-40 (45) 50/5 Class 1 1.5VA ⌀ 51mm or 61 x 12mm Busbar
Heavy Item - No Free ShippingRishabh Rish Xmer 86-40 (45) 50/5 Class 1 1.5VA ⌀ 51mm or 61 x 12mm Busbar, Currentr Transformer Features Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Rishabh Part Number Rish Xmer 86-40 (45) 50/5 Class 1 1.5VA Technology AC Current Transformer Ratio 50/5 Aperture Size ⌀ 51mm or 61 x 12mm Busbar VA Rating 1.5VA Accuracy Class Class 1 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -30°C / 85°C Continuous Current (max) 50Amp x 1.2 Termination Style Screw Unit Weight 0.9kg Factory Pack Qty 9 Datasheet Product Datasheet
-
DK 20 C10 U, Hall Effect DC Current Transducer, 5, 10, 20A DC, 0-10V unipolar output, 20-50VDC supply
Free Aus Post Shipping for $300 SpendLEM DK 20 C10 U, Hall Effect DC Current Transducer, 5, 10, 20A DC, 0-10V unipolar output, 20-50VDC supply Compact and versatile Split Core DC current sensor, selectable 5, 10, 20 Amp DC. Choice of output types: 0-20mA, 4-20 mA, 0-5 V or 0-10 V Features ⌀19.1mm Aperture DC Unipolar Measurement 0-10V voltage output Busbar, or panel mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification LEM Part Number DK 20 C10 U Technology DC Current Transformer with Process Output ROHS Yes Supply Voltage 20-50VDC Nominal Current (RMS + DC) 5,10,20 Amp Selectable Response Time < 100ms Output 0-5V Analogue Isolation 3kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 2% Termination Style 2 x UNC8 Cylindric Head Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
Rish Xmer 104-80 (45) 1500/5 Class 0.5, 20VA, ⌀ 65mm or 85 x 12mm Busbar
Heavy Item - No Free ShippingRishabh Rish Xmer 104-80 (45) 1500/5 Class 0.5 Series Current Transformer Features Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Rishabh Part Number Rish Xmer 104-80 (45) 1500/5 Class 0.5 Technology AC Current Transformer Ratio 1500/5 Aperture Size ⌀ 65mm or 85 x 12mm Busbar VA Rating 20VA Accuracy Class Class 0.5 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -30°C / 85°C Continuous Current (max) 1500Amp x 1.2 Termination Style Screw Unit Weight 0.9kg Factory Pack Qty 9 Datasheet Product Datasheet
-
Rish Xmer 140-100H (45) 2500/5 Class 0.5, 45VA, ⌀ 86mm or 101 x 31mm Busbar
Heavy Item - No Free ShippingRishabh Rish Xmer 140-100H (45) 2500/5 Class 0.5 Series Current Transformer Features Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Rishabh Part Number Rish Xmer 140-100H (45) 2500/5 Class 0.5 Technology AC Current Transformer Ratio 2500/5 Aperture Size ⌀ 86mm or 101 x 31mm Busbar VA Rating 45VA Accuracy Class Class 0.5 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -30°C / 85°C Continuous Current (max) 2500Amp x 1.2 Termination Style Screw Unit Weight 1.2kg Factory Pack Qty 9 Datasheet Product Datasheet
-
DC-0-5-420B-1.0, Hall Effect DC Current Transducer, 0-5 Amp DC, 4-20mA Bipolar output, 24VDC supply
DC-0-5-420B-1.0, Hall Effect DC Current Transducer, 0-5 Amp DC, 4-20mA Bipolar output, 24VDC supply Compact and versatile Split Core DC current sensor, 0-5 Amp DC, 4-20 mA Bipolar Output Other measurement ranges available on request Features ⌀20mm Aperture DC Bipolar Measurement 4-20mA analogue output Busbar, or DIN Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number DC-0-5-420B-1.0 Technology DC Hall Current Sensor with Process Output ROHS Yes Supply Voltage 24VDC Nominal Current (DC) 0-5 Amp Response Time < 1uS Output Bipolar 4-20mA Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Terminals Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet
$385.00
$454.30 inclGST -
H-5-2-24, Split Core Hall Effect DC Current Transducer, 0-5 Amp DC, 4-20mA unipolar output, 31mm aperture, 24VDC supply
H-5-2-24, Split Core Hall Effect DC Current Transducer, 0-5 Amp DC, 4-20mA unipolar output, 31mm aperture, 24VDC supply Compact and versatile Split Core DC current sensor, 0-10 Amp DC, 4-20mA Unipolar Output Features ⌀31mm Aperture Split Core DC Unipolar Measurement 4-20mA analogue output Busbar, or DIN Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Mount Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number H-5-2-24 Technology DC Hall Effect Current Transducer with Process Output ROHS Yes Supply Voltage 24VDC Nominal Current (DC) 0-5 Amp Response Time < 200mS Output Unipolar 4-20mA Analogue Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Screw Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet
$415.00
$489.70 inclGST -
FTCK-5-PLAS-3000-B, Type K Class B, Thermocouple, Plastic Industry Style x 4.8mm Probe w/ 3000mm Screened Teflon/Braided SS cable, -20 to 1000 Deg C
Free Aus Post Shipping for $300 SpendFastron FTCK-5-PLAS-3000-B 4.8mm Type K Metal Sheath Thermocouple with Spring Bayonet Cap Quick Release Fitting for Plastic Industry Class B Accuracy Teflon SS Braided Cable Low Long Term Drift Rated for -20 to 850 Deg C Max Spring Cable Connection 20 x 4.8mm MIMS Specification Fastron Part Number FTCK-5-PLAS-3000-B Sensor Type Type K Thermocouple No of Wires 2 Probe Length 20mm Sheath Thickness 5mm Sheath Material SS304 Stainless Steel Accuracy Class B Approvals N/A Cable length 3 Meters Cable Type Teflon/Braided Stainless Steel with Spring Bayonet Cap Temperature Range -20 to 350 Deg C Special Feature Quick Release Fitting, Strain Relief Spring Cable Mounting Style Quick Release Fitting Weight 300g Factory Pack Qty 1 Datasheet Datasheet
-
HO 8-NP-0000 Kit 5P, Evaluation Kit 5pcs with PCB
Free Aus Post Shipping for $300 SpendLEM HO 8-NP-0000 Kit 5P Series Open Loop AC/DC Hall Effect Sensor Features Open loop multi-range current transducer Multirange through PCB routing Voltage output Single power supply +5 V Overcurrent detect 2.93 × IP N (peak value) Galvanic separation between primary and secondary circuit Low power consumption Compact design for THT PCB mounting Factory calibrated Dedicated parameter settings available on request Advantages Low offset drift Over-drivable Vref Creepage / clearance > 8 mm Fast response Applications AC variable speed and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Combiner box Solar inverter on DC side of the inverter (MPPT). Standards IEC 61800-1: 1997 IEC 61800-2: 2015 IEC 61800-3: 2004 IEC 61800-5-1: 2007 IEC 62109-1: 2010 UL 508: 2013. Application Domain Industrial. Specification LEM Part Number HO 8-NP-0000 Technology Open Loop Hall Effect Aperture N/A ROHS Yes Supply Voltage 5 VDC Load Current (RMS + DC) 8 Amp Measurement Range +/-20 Amp Output 2.5 Vref Isolation 4.3 kV Bandwidth DC-250 kHz Mounting Style Surface Mount Operating Temperature Range -40°C / 105°C Accuracy 1% Termination Style PCB Surface Mount Unit Weight 34g Factory Pack Quantity 25 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
FT063080P, 630/5 Amp Split Core CT, Class 0.5 2.5VA AC Current Transformer, 50 x 80mm Aperture, Dimension 145 x 159 x 37mm
Free Aus Post Shipping for $300 SpendFT063080P, 630/5 Amp Split Core CT, Class 1 3VA Series Current Transformer Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number FT063080P Technology Split Core AC Current Transformer Ratio 630/5 Aperture Size 50 x 80mm VA Rating 3VA Accuracy Class Class 1 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -10°C / 50°C Continuous Current (max) 630Amp x 1.2 Termination Style Screw Approvals UL, CE Unit Weight 1150g Factory Pack Qty 1 Datasheet Product Datasheet Installation Guide
-
SDM630MCT-LORAWAN-MID-AU915, DIN Rail Mount kWh Meter, 3 Phase, 240VAC aux, Class 1, 1/5 Amp CT Connect, w/ 2 x pulse outputs and LoRaWaN AU915 Wireless Comms
SDM630MCT-LORAWAN-MID-AU915, DIN Rail Mount kWh Meter, 3 Phase, 240VAC aux, Class 1, 1/5 Amp CT Connect, w/ 2 x pulse outputs and LoRaWaN AU915 Wireless Comms 1/5 Amp CT Input LoRaWaN AU915 Optional Mbus Model available True RMS values of currents and voltages 1 x Configurable Pule Output (via Display Menu or Modbus) 1 x Fixed Pulse Output (1000imp/kwh) The meter is intended for measuring, and monitoring single-phase or 3 phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power to the 30th Harmonic) from the measured signals. Features : Accuracy class 1 Measurement of Active and Reactive Power Modbus RTU communication up to 38,400 bit/s communication Pulse output as standard Graphic LCD with illumination Specification Eastron Europe Part Number SDM630MCT-LORAWAN-MID-AU915 Functions Three Phase Energy Meter Supply Voltage 230V L-N +/-15% < 5VA Nominal Measurement Range 415V L-L 230V L-N, 1/5 Amp +/-15% Maximum Measurement Range 480V L-L 230V L-N, 1/5 Amp Nominal CT Current Input 1/5 Amp Pulse Output 2 x Passive, (1 x Configurable 60/100/200ms) Tariff Input N/A Accuracy Class 1 (I,U,F,kW,kWh) Class 2 (Reactive) Mounting Din Rail Real Time Clock 1min/month (30ppm) Internal Memory N/A Dimensions 72mm x 100mm x 66mm (4 modules wide) Isolation 4kV Comms LoRaWaN AS915 Weight 150g Certification EN 61010-1 Installation Category III Factory Pack Qty 1 Safety IP51(Indoor) Enclosure Material Noryl with fire protection to UL94-V-O. Self extinguishing Enclosure Size DIN 42880 4 Modules Operating Temperature -20 →+70 °C Documents Product Datasheet User Manual Modbus Protocol Setup Video - CT Ratio Unlock Modbus Utility EEM Meter Setting Software Utility
$339.00
$400.02 inclGST -
Xmer CT Split 105/50SC 200/5 Class 1 3.75VA, 43 x 55mm Aperture
Free Aus Post Shipping for $300 SpendXmer CT Split 105/50SC 200/5 Class 1 3.75VA, 43 x 55mm Aperture Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Rishabh Part Number Xmer CT Split 105/50SC 200/5 Class 1 3.75VA Technology Split Core AC Current Transformer Ratio 200/5 Aperture Size 43 x 55mm VA Rating 3.755VA Accuracy Class Class 1 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -30°C / 85°C Continuous Current (max) 200Amp x 1.2 Termination Style Screw Unit Weight 800g Factory Pack Qty 9 Datasheet Product Datasheet
-
TRIB-22D-R-240-NC, 22mm LED Pushbutton & Indicator RED 240VAC, NORMALLY CLOSED, Plastic, IEC60947-5-1
TRIB-22D-R-240-NC, 22mm LED Pushbutton & Indicator RED 240VAC, NORMALLY CLOSED, Plastic, IEC60947-5-1 Pushbutton Indicator Switches are a combinations of LED indicator Series and Momentary Pushbutton Switches. LED Will activate while the contacts are connected. Widely Used for Rugged Industrial Applications Including Critical Machinery requiring safe operation by the user. Features : 240VAC or 24AC/DC (400VAC Special Orders) 1 Pole Momentary LED Illumination Rated for 6 Amp @ 240VAC, or 0.3 Amp @ 240VDC Ø 22.5mm Cutout Standards : IP40 IEC60947-5-1 CE Specification TRENT Part Number TRIB-22D-R-240-NC Functions Momentary (Normally Closed) Nominal Voltage 240VAC @ 50/60Hz Impulse Voltage Wear Resistance 6kV Illumination Type RED LED Short Circuit Protection (Fuse) Recommend 10A gG Fuse Nominal Current Range AC 6 Amp @240VAC Nominal Current Range DC 0.3 Amp @ 240VDC Mechanical Compression Force at Closing 20N Mechanical Compression Force at Closing 8N Humidity 35-85% Approvals CE Standards IP40, IEC60947-5-1 Weight Enclosure Material UL94V0 Factory Pack Qty 1 TRENT(Fastron) Head Office Australia Datasheet Product Datasheet
$19.00
$22.42 inclGST