TT 50-SD, Current Transformer, 50 Amp, 16,66mA Output
Free Aus Post Shipping for $300 SpendLEM TT 50-SD Series Current Transformer (, Obsolete) Features Quick Release Split Core System Ø 8 mm sensing aperture for noncontact measurementMounting Feet Supplied Self Powered Cable output (1m) Rated System Voltage 0.30/3.5kV Isolated plastic case recognized according to UL 94-V0 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification LEM Part Number TT 50-SD Technology Split Core AC Current Transformer Ratio 50/16.66mA Aperture Size ? 8mm Protection Degree IP40 Accuracy Class Class 1 Output 16.66 mA AC (+20%) Isolation 3.5kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -30°C / 85°C Continuous Current (max) 50Amp x 1.2 Termination Style 1m Flying Lead Unit Weight 80g Factory Pack Qty 9 Datasheet Product Datasheet Alternatives This part is , Obsolete. Contact Us for Possible Replacement for replacement
-
ESCT-TA24-100A/100mA + HY-2.0, 100A/100mA Measurement, Class 1 Split Core CT's
Free Aus Post Shipping for $300 SpendEastron Europe Electronics ESCT-TA24-100A/100mA + HY-2.0, 100A/100mA Measurement, Class 1 Split Core CT's Features Quick Release Split Core System Cable Mount 100mAmp Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads with HY-2.0 Connector Applications Eastron Modular Metering Equipment Energy Monitoring Load Balancing Power Quality Measurements Specification Eastron Europe Part Number ESCT-TA24-100A/100mA + HY-2.0 Technology Split Core AC Current Transformer Ratio 100/100mA Aperture Size ø 24 mm VA Rating 1VA Accuracy Class Class 1 Output 100mA (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 100Amp x 1.2 Termination Style 0.9M Flying leads with HY-2.0 Connector Unit Weight 100g Factory Pack Qty 9 Datasheet Product Datasheet Application Notes Installation Guide CRJ-31 Connector User Guide
-
FT025080P, 250/5 Amp Split Core CT, Class 1 1.5VA AC Current Transformer, 50 x 80mm Aperture, Dimension 145 x 159 x 37mm
Free Aus Post Shipping for $300 SpendFT025080P, 250/5 Amp Split Core CT, Class 1 1.5VA Series Current Transformer Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number FT025080P Technology Split Core AC Current Transformer Ratio 250/5 Aperture Size 50 x 80mm VA Rating 1.5VA Accuracy Class Class 1 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -10°C / 50°C Continuous Current (max) 250Amp x 1.2 Termination Style Screw Approvals UL, CE Unit Weight 1150g Factory Pack Qty 1 Datasheet Product Datasheet Installation Guide
-
ESCT-TA24-200A/100mA + HY-2.0, 200A/100mA Measurement, Class 1 Split Core CT's
Free Aus Post Shipping for $300 SpendEastron Europe Electronics ESCT-TA24-200A/100mA + HY-2.0, 200A/100mA Measurement, Class 1 Split Core CT's Features Quick Release Split Core System Cable Mount 100mAmp Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads with HY-2.0 Connector Applications Eastron Modular Metering Equipment Energy Monitoring Load Balancing Power Quality Measurements Specification Eastron Europe Part Number ESCT-TA24-200A/100mA + HY-2.0 Technology Split Core AC Current Transformer Ratio 200/100mA Aperture Size ø 24 mm VA Rating 1VA Accuracy Class Class 1 Output 100mA (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 200Amp x 1.2 Termination Style 0.9M Flying leads with HY-2.0 Connector Unit Weight 100g Factory Pack Qty 9 Datasheet Product Datasheet Application Notes Installation Guide CRJ-31 Connector User Guide
-
VA90B, Touch Pad Multimeter For Average RMS, 0-1000V AC/DC, Linear Frequency, AC/DC uA/mA/10A, -200 to 1000 Deg C, 0- 60 MOhm, 0-60mF, Diode Test, Continuity Test
Free Aus Post Shipping for $300 SpendVA Instruments VA90A, Touch Pad Multimeter For Average RMS, 0-1000V AC/DC, Linear Frequency, AC/DC uA/mA/10A, -200 to 1000 Deg C, 0- 60 MOhm, 0-60mF, Diode Test, Continuity Test For Testing of: Touch Pad Multimeter For True RMS AC/DC Voltage 0-1000V Linear Frequency AC/DC uA/mA/10A Temperature -200 to 1000 Deg C Resistance 0- 60 MOhm Capacitance 0-60mF Diode Test Continuity Test TTL Frequency/Duty Auto Range True RMS Measurement Display Counts 6000, IP67 AUTO Back Light USB Chargeable Li Batteries 190 x 190 x 40mm USB Comms & Free App IP67 Specification Datasheet Datasheet
-
ESCT-TA24-150A/100mA + HY-2.0, 150A/100mA Measurement, Class 1 Split Core CT's
Free Aus Post Shipping for $300 SpendEastron Europe Electronics ESCT-TA24-150A/100mA + HY-2.0, 150A/100mA Measurement, Class 1 Split Core CT's Features Quick Release Split Core System Cable Mount 100mAmp Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads with HY-2.0 Connector Applications Eastron Modular Metering Equipment Energy Monitoring Load Balancing Power Quality Measurements Specification Eastron Europe Part Number ESCT-TA24-150A/100mA + HY-2.0 Technology Split Core AC Current Transformer Ratio 150/100mA Aperture Size ø 24 mm VA Rating 1VA Accuracy Class Class 1 Output 100mA (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 150Amp x 1.2 Termination Style 0.9M Flying leads with HY-2.0 Connector Unit Weight 100g Factory Pack Qty 9 Datasheet Product Datasheet Application Notes Installation Guide CRJ-31 Connector User Guide
-
VA311B, 1000Amp AC/DC Clamp Meter. For True RMS Power Measurements, Ranges 1000VDC/700VAC/1000 Amp AC/600/1000uF/100Khz, with Diode test, Continuity Test, AUTO RANGING
Free Aus Post Shipping for $300 SpendVA Instruments VA311B, 1000Amp AC/DC Clamp Meter. For True RMS Power Measurements, Ranges 1000VDC/700VAC/1000 Amp AC/1000Amp DC/600/1000uF/100Khz, with Diode test, Continuity Test, AUTO RANGING For Testing of: 1000Amp AC/DC Clamp-On Meter For True RMS Power Measurements. Ranges: DC Voltage 6/60/1000VAC +/-0.8%+5) AC Voltage 6/60/600/700VAC AC Current 600/1000A +/-3%+5 Resistance 600 Ohm/6Kohm/60KOhm/600KOhm +/-1%+3 Capacitance 600nF/6uF/60uF/600uF/1000uF +/-4%+5 Frequency 40/600/6K/60K/100KHz +/-0.1%+2 ADP Measurement 600mV +/-3%+5 Diode Test Continuity Test AUTO & MANUAL RANGING 225x86x32mm 40mm Diameter Jaw Requires 3 x AAA Batteries Specification Datasheet Datasheet
-
KNL18-01-415VAC AC Contactor 240/400/500/690V, Overload 144(10s), 170(5s), 200(1s), 500(0.001s) (each pole), 415VAC Control Voltage, 4 Pole 3 x NO, 1 x NC Nominal Current = 18 Amps
Free Aus Post Shipping for $300 spendIskra Doo KNL18-01-415VAC AC Contactor 240/400/500/690V, Overload 144(10s), 170(5s), 200(1s), 500(0.001s) (each pole), 415VAC Control Voltage, 4 Pole 3 x NO, 1 x NC Nominal Current = 18 Amps Capacitor duty contactors are designed to meet the requirements of capacitor duty applications. Contactors are fitted with a block of three auxiliary contacts connected in series with six quick discharge damping resistors, two per each phase. Peak current is limited to the value within the contactor making capacity. Features : High contact reliability at low voltages High electrical and mechanical endurance and high switching capacity Four and Three-pole contactors Optional auxiliary contacts Ratings from 6 Amp to 1000 Amp UL, CSA Approved Advantages : Saves costs of expensive replacement Long electrical life Reduces watt losses during “ON” condition, saves energy High safety No risk of dangerous voltage Less maintenance and downtime Standard control voltages: 24 V 50/60 Hz, 240 V 50/60 Hz, 415 V 50/60 Hz Specification Iskra Doo Part Number KNL18-01-415VAC Functions 4 Pole Contactor with Aux contacts Nominal Voltage 230/400/500/690VAC @ 50/60Hz Current Carrying Capacity as per UL 18 Amp Continuous @ 55 Deg C Overload Capability 144(10s), 170(5s), 200(1s), 500(0.001s) Auxiliary Contacts 3 x NO, 1 x NO Trip Delay Time 2-10ms Electrical Life 200,000 Ops Operating Temperature -25 to 40 Deg C Mechanical Operations 10.000,000 Ops Control Voltage 415VAC Power Dissipation 0.36W Approvals UL, CSA Standards IEC/EN 60947-4-1, AS/NZ 61009-1 Weight 200g Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet Contactor Catalogue Iskra Contactor Catalogue
-
FT030080P, 300/5 Amp Split Core CT, Class 1 1.5VA AC Current Transformer, 50 x 80mm Aperture, Dimension 145 x 159 x 37mm
Free Aus Post Shipping for $300 SpendFT030080P, 300/5 Amp Split Core CT, Class 1 1.5VA Series Current Transformer Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number FT030080P Technology Split Core AC Current Transformer Ratio 300/5 Aperture Size 50 x 80mm VA Rating 1.5VA Accuracy Class Class 1 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -10°C / 50°C Continuous Current (max) 300Amp x 1.2 Termination Style Screw Approvals UL, CE Unit Weight 1150g Factory Pack Qty 1 Datasheet Product Datasheet Installation Guide
-
A24125, Solid State Relay, Single Phase 90-280VAC Control, 125A, 24-280VAC Load
Free Aus Post Shipping for $300 SpendCrydom A24125, Solid State Relay, Single Phase 90-280VAC Control, 125A, 24-280VAC Load Features • Ratings from 25A to 125 Amp @ 24-280 VAC • SCR output for heavy industrial loads • Zero voltage or instantaneous turn-on outputs • UL/CSA/VDE Approved, CE Compliant to EN60950-1 • Improved SEMS screw and washer • Redesigned housing with anti-rotation barriers • AC & DC control types • Direct bond copper substrate • EMC compliant to Level 3 • Direct power lead frame • Epoxy free design Spec Crydom Part Number A24125 Switching Type Zero Crossing ROHS Yes (Details) Control Voltage 90 - 280VAC Load Current 125 Amp (rms),90 Amp Continuous Surge Capability 1670 Amp (peak) Special Feature None Mounting Style Panel Mount Load Voltage Range 24-280VAC EMC Compliant Level 3 Termination Style Screw Unit Weight 75g Factory Pack Qty 20 Datasheet Product Datasheet Notifications Please note Changes from Gen 3 to Gen 4 (current) package design here App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies
-
KNL38G-00 + NPLG-01, AC Contactor 240/400/500/690V, Overload 304(10s), 320(5s), 350(1s), 900(0.001s) (each pole), 24VDC Control Voltage, 4 Pole 3 x NO 1 x NC, Nominal Current = 38 Amps
Free Aus Post Shipping for $300 SpendIskra Doo KNL38G-00 + NPLG-01, AC Contactor 240/400/500/690V, Overload 304(10s), 320(5s), 350(1s), 900(0.001s) (each pole), 24VDC Control Voltage, 4 Pole 3 x NO 1 x NC, Nominal Current = 38 Amps Capacitor duty contactors are designed to meet the requirements of capacitor duty applications. Contactors are fitted with a block of three auxiliary contacts connected in series with six quick discharge damping resistors, two per each phase. Peak current is limited to the value within the contactor making capacity. Features : High contact reliability at low voltages High electrical and mechanical endurance and high switching capacity Four and Three-pole contactors Optional auxiliary contacts Ratings from 6 Amp to 1000 Amp UL, CSA Approved Advantages : Saves costs of expensive replacement Long electrical life Reduces watt losses during “ON” condition, saves energy High safety No risk of dangerous voltage Less maintenance and downtime Standard control voltages: 24 V 50/60 Hz, 240 V 50/60 Hz, 415 V 50/60 Hz Specification Iskra Doo Part Number KNL38G-00 + NPLG-01 Functions 4 Pole Contactor with (3 x NO, 1 x NC) with 1 x NO Aux Contacts Nominal Voltage 230/400/500/690VAC @ 50/60Hz Current Carrying Capacity as per UL 38 Amp Continuous @ 55 Deg C Overload Capability 304(10s), 320(5s), 350(1s), 900(0.001s) Auxiliary Contacts 1 x NO (+Optional Snap On 4 Pole NPL3) Trip Delay Time 2-10ms Electrical Life 200,000 Ops Operating Temperature -25 to 55 Deg C Mechanical Operations 10.000,000 Ops Control Voltage 24VDC Power Dissipation 2.3W Approvals UL, CSA Standards IEC/EN 60947-4-1, AS/NZ 61009-1 Weight 200g Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet Contactor Catalogue Iskra Contactor Catalogue
-
FWS298N1600 AC Switch, Water Cooled, Standard Water Cooler, 1600VAC, 2000Amp RMS Continous, 12mm x 13.7mm Nipples
Heavy Item - No Free ShippingFWS298N1600 AC Switch, Water Cooled, Standard Water Cooler, 1600VAC, 1000Amp RMS Continuous, 12mm x 13.7mm Nipples 550 Amp RMS Output using T430N16KOF Brass inlets and outlets for hose, along with plug. Pressure Tested to 300 mbar Specification Thermal Rating based on 40°C max inlet water temperature. Type No Litres/min Device Rck deg C/W mbar kg FWS298N1600 4 T430N16KOF 0.10 190 3.5kg 4 T720N16KOF 0.08 190 4 T1190N16KOF 0.08 190 Type No Maximum Junction Temp Itsm RMS Current Vvrm Dimensions FWS298N1600 125 Deg C 5200 A²/s 550 Amp 1700V 196x247x110mm Approx Datasheet Product Datasheet