Search results for "24�üҾױ������� �Ų� banonpi �ٳ��� �������ɳ����� �ɸ��Թ��� �۾��������ſ� �������� �ź��ڻ����ڱݴ�������"
-
HAZ 10000-SBI, O/L Current Transducer, 10000 Amp, +/-20mA Instant Output, +/-15VDC supply
Free Aus Post Shipping for $300 SpendLEM HAZ 10000-SBI, O/L Current Transducer, 10000 Amp, +/-20mA Instant Output, +/-15VDC supply For the electronic measurement of currents: DC, AC, pulsed, mixed, with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit). Features Instantaneous output version +/-10V, +/-20mA True RMS output versions 4-20mA, 0-10V putput Hall effect measuring principle Galvanic isolation between primary and secondary circuit Instantaneous voltage output Isolation voltage 17kV Rms /50 Hz /1min Low power consumption Package in PBT meeting UL 94-V0 Instantaneous voltage output Advantages Easy installation Small size and space savings Only one design for wide Ratings range High immunity against external interference Applications Battery supplied applications Uninterruptible Power Supplies (UPS) Power supplies for welding and telecom applications Application domain Industrial Traction Specification LEM Part Number HAZ 10000-SBI Technology Open Loop Hall Effect ROHS Yes Supply Voltage +/- 15VDC Load Current (RMS + DC) 12000 Amp Overload Rating 30000 At Output +/-20 mA Instantaneous Isolation 17kV (AC, 50Hz, 1 min) Bandwidth DC-3kHz Mounting Style Busbar Mount Operating Temperature Range -25°C / 85°C Accuracy 1% Termination Style F2023A (FUJICON) Unit Weight 6kg Factory Pack Qty 2 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
HAZ 6000-SBI, O/L Hall Effect Current Sensor, +/-20mA Instant Output, +/-15VDC Supply
Free Aus Post Shipping for $300 SpendLEM HAZ 6000-SBI, O/L Hall Effect Current Sensor, +/-20mA Instant Output, +/-15VDC Supply For the electronic measurement of currents: DC, AC, pulsed, mixed, with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit). Features Instantaneous output version +/-10V, +/-20mA True RMS output versions 4-20mA, 0-10V output Hall effect measuring principle Galvanic isolation between primary and secondary circuit Instantaneous voltage output Isolation voltage 17kV Rms /50 Hz /1min Low power consumption Package in PBT meeting UL 94-V0 Instantaneous voltage output Advantages Easy installation Small size and space savings Only one design for wide Ratings range High immunity against external interference Applications Battery supplied applications Uninterruptible Power Supplies (UPS) Power supplies for welding and telecom applications Application domain Industrial Traction Specification LEM Part Number HAZ 6000-SBI Technology Open Loop Hall Effect ROHS Yes Supply Voltage +/- 15VDC Load Current (RMS + DC) 6000 Amp Overload Rating 30000 At Output +/-20 mA Instantaneous Isolation 17kV (AC, 50Hz, 1 min) Bandwidth DC-3kHz Mounting Style Busbar Mount Operating Temperature Range -25°C / 85°C Accuracy 1% Termination Style F2023A (FUJICON) Unit Weight 6kg Factory Pack Qty 2 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
FGM6-4P-1600M 1250A, 4 Pole Moulded Case Circuit Breaker (MCCB) Thermal & Magnetic, Fixed Type ICS=65kA 1250 Amp, 400/690VAC
Heavy Item - No Free ShippingTrent FGM6-4P-1600M 1250A, 4 Pole Moulded Case Circuit Breaker (MCCB) Thermal & Magnetic, Fixed Type 65kA 1250 Amp, 400/690VAC Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a dis connector in case of electric shock Features : 4 Pole Disconnect 65kA Short Circuit Rating @400VAC Suitable for Main Incoming Breaker Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGM6-4P-1600M 1250A Functions 4 Pole MCCB Nominal Voltage 400/690VAC @ 50/60Hz Nominal Current Range 1250 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 8kV Operating Temperature -25 to 50 Deg C Mechanical Operations 20,000 Ops Insulation Voltage 800V Short Circuit Current 65kA Approvals KEMA EUR, CE Standards IEC/EN 60898-1,IEC/EN 60947-3, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 12.9kg Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet
-
FGM6S-4P-400M 400A, 4 Pole Moulded Case Circuit Breaker (MCCB) Thermal, Adjustable Type ICS=60kA 400 Amp, 400/690VAC
Heavy Item - No Free ShippingTrent FGM6S-4P-400M 400A, 4 Pole Moulded Case Circuit Breaker (MCCB) Thermal, Adjustable Type 60kA 400 Amp, 400/690VAC Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : 4 Pole Disconnect 60kA Short Circuit Rating @400VAC Suitable for Main Incoming Breaker Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGM6S-4P-400M 400A Functions 4 Pole MCCB Nominal Voltage 400/690VAC @ 50/60Hz Nominal Current Range 400 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 8kV Operating Temperature -25 to 50 Deg C Mechanical Operations 20,000 Ops Insulation Voltage 800V Short Circuit Current (Ics) 60kA Approvals KEMA EUR, CE Standards IEC/EN 60898-1,IEC/EN 60947-3, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 5.1kg Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet
-
ART-B22-D175-SP3 + AI-P1A - 3 Pcs, 3 Phase Rogowski Coil Set, 1 Amp AC, Sensitivity, and Measurement Range, 17.5cm Diameter, 3M Integrator Cable
Free Aus Post Shipping for $300 SpendLEM ART-B22-D175-SP3 + AI-P1A - 3 Pcs, 3 Phase Rogowski Coil Set, 1 Amp AC, Sensitivity, and Measurement Range, 17.5cm Diameter, 3M Integrator Cable The universal Rogowski coil integrator AI-P1A complements LEM’s flexible clip-around coil ART and ARU range. The design is based on digital processing to give combined dynamic range, accuracy and versatility of use. It offers a wide range of output signals both RMS and instantaneous. AI-P1A is DIN rail mounted and can be stacked for multiphase application without spacing thanks to its low power dissipation. Input signal Accuracy Class 1 (IEC 61869-2) [1]. Linearity error ≤ 0.10 %. Protection degree IP2X. 35 mm DIN rail mounted. Push-in terminals. 1 Amp instantaneous output. 6 selectable sensitivities depending on Rogowski coil: 22.5, 70, 80, 85, 100, 120 mV/kA at 50 Hz. 12 selectable ranges: 100, 200, 300, 400, 500, 600, 800, 1000, 1500, 2000, 4000, 5000 A. Ambient operating temperature −25...+70 °C. Advantages Compact design for DIN rail assembly High accuracy Class 1 (IEC 61869-2) Setup by user via Select / Edit buttons Clear status indication via bi-color led Applications MV/LV substations on LV side: Transformer Condition Monitoring Power metering: current measurement for active power calculation Building sub-metering: energy efficiency monitoring, consumption analysis and cost allocation Power quality monitoring: electrical loads and distribution system equipment Fault Detection, Isolation and Repair (FDIR): isolate the site of the fault Remote Terminal Units (RTU) Phasor Measurement Units (PMU) Standards IEC 61010-1: 2010 UL EMC: IEC 61326-1:2012 Options Cross Power Plug-in: side contacts to stack up to 3 Integrator modules and use only one power supply. Specification LEM Part Number ART-B22-D175 + AI-P1A-SP3 - 3 Pcs Function 3 Phase AC Current Measurement Measuring Range Selectable 5000,4000,2000,1500,1000,800,600,500,400,300,200,100Amp Sensitivity Selectable 22.5,70,80,85,100,120mV/kA @ 50 Hz Output 1 Amp output Frequency Measuring Range 50-1500Hz (15th Harmonic) Operating Voltage 10-32VDC Accuracy 1% from 25 to 5000 Amp Current Consumption 100mA (max) Dimensions 100mm x 78mm x 15mm (Integrator), 7cm Diameter (Coils) Mounting Din Rail Mount Integrator to Coil cable 3M Twisted and Screened Integrator to Meter cable User Supplied Shielded cable 1.5mm sqr, up to 6m long Operating Temperature -25°C - 70°C Storage Temperature -45°C to 80°C Isolation (50Hz, 1 min) 1.5kV True RMS Response Time 160-190ms Termination Style Push-in for 1.5mm sqr wire Weight 58g Factory Pack Qty 1 Certifications UL, ROHS Datasheet AI-P1A Datasheet ART Series Datasheet Application Notes User Notice 1) The Rogowski coil can measure any primary current as there is no saturation effect. 2) Not tested given that in the worst case (load = 0 Ohm i.e. short circuit on the output) the peak dissipated power remains low (< 2 Watts) 3) Frequency bandwidth and phase shift modelling schematic can be provided on request. 4) Referring to the main phase offset of 90 ° (a Rogowski coil is a derivative current transducer) 5) Considering a primary conductor of at least ⌀ 15 mm, perpendicular and in contact with the Rogowski coil. 6) Considering an external conductor of at least ⌀ 15 mm the same current level than internal conductor, perpendicular and in contact with the Rogowski coil.
-
FGM6-3P-1250M 1250A, 3 Pole Moulded Case Circuit Breaker (MCCB) Thermal & Magnetic, Fixed Type ICS=50kA 1250 Amp, 400/690VAC
Heavy Item - No Free ShippingTrent FGM6-3P-1250M 1250A, 3 Pole Moulded Case Circuit Breaker (MCCB) Thermal & Magnetic, Fixed Type 50kA 1250 Amp, 400/690VAC Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a dis connector in case of electric shock Features : 3 Pole Disconnect 50kA Short Circuit Rating @400VAC Suitable for Main Incoming Breaker Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGM6-3P-1250M 1250A Functions 3 Pole MCCB Nominal Voltage 400/690VAC @ 50/60Hz Nominal Current Range 1250 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 8kV Operating Temperature -25 to 50 Deg C Mechanical Operations 20,000 Ops Insulation Voltage 800V Short Circuit Current 50kA Approvals KEMA EUR, CE Standards IEC/EN 60898-1,IEC/EN 60947-3, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 10.9kg Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet
-
FGM6-3P-1250M 1000A, 3 Pole Moulded Case Circuit Breaker (MCCB) Thermal & Magnetic, Fixed Type ICS=50kA 1000 Amp, 400/690VAC
Heavy Item - No Free ShippingTrent FGM6-3P-1250M 1000A, 3 Pole Moulded Case Circuit Breaker (MCCB) Thermal & Magnetic, Fixed Type 50kA 1000 Amp, 400/690VAC Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a dis connector in case of electric shock Features : 3 Pole Disconnect 50kA Short Circuit Rating @400VAC Suitable for Main Incoming Breaker Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGM6-3P-1250M 1000A Functions 3 Pole MCCB Nominal Voltage 400/690VAC @ 50/60Hz Nominal Current Range 1000 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 8kV Operating Temperature -25 to 50 Deg C Mechanical Operations 20,000 Ops Insulation Voltage 800V Short Circuit Current 50kA Approvals KEMA EUR, CE Standards IEC/EN 60898-1,IEC/EN 60947-3, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 10.9kg Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet
-
HAZ 4000-SBI, O/L Hall Effect Current Transducer, 4000A, +/-20mA Instant Output, +/-15VDC supply
Free Aus Post Shipping for $300 SpendLEM HAZ 4000-SBI, O/L Hall Effect Current Transducer, 4000A, +/-20mA Instant Output, +/-15VDC supply For the electronic measurement of currents: DC, AC, pulsed, mixed, with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit). Features Instantaneous output version +/-10V, +/-20mA True RMS output versions 4-20mA, 0-10V output Hall effect measuring principle Galvanic isolation between primary and secondary circuit Instantaneous voltage output Isolation voltage 17kV Rms /50 Hz /1min Low power consumption Package in PBT meeting UL 94-V0 Instantaneous voltage output Advantages Easy installation Small size and space savings Only one design for wide Ratings range High immunity against external interference Applications Battery supplied applications Uninterruptible Power Supplies (UPS) Power supplies for welding and telecom applications Application domain Industrial Traction Specification LEM Part Number HAZ 4000-SBI Technology Open Loop Hall Effect ROHS Yes Supply Voltage +/- 15VDC Load Current (RMS + DC) 4000 Amp Overload Rating 30000 At Output +/-20 mA Instantaneous Isolation 17kV (AC, 50Hz, 1 min) Bandwidth DC-3kHz Mounting Style Busbar Mount Operating Temperature Range -25°C / 85°C Accuracy 1% Termination Style F2023A (FUJICON) Unit Weight 6kg Factory Pack Qty 2 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
HS211 + MCBC4825DL, Single Phase Proportional Burst Controller with Heatsink, 20 Cycles, 4-20mA Input, 90-530VAC, 24 Amps
Free Aus Post Shipping for $300 SpendCrydom HS211 + MCBC4825DL, Single Phase Proportional Burst Controller with Heatsink, 20 Cycles, 4-20mA Input, 90-530VAC, 24 Amps Features Proportional Phase Control Input Ratings from 25A to 90 Amp @ 380-530 VAC SCR output for heavy industrial loads Zero voltage or instantaneous turn-on outputs UL/CE/ROHS Compliant Direct bond copper substrate Direct power lead frame Epoxy free design Panel Mount Din Rail Mount Spec Part Number HS211 + MCBC4825DL Switching Type Burst Fire (Zero Crossing) ROHS/CE/UL Yes Control Voltage 4-20mA Proportional Input Load Current 24 Amp (rms) @ 40 Deg C Surge Capability 239 Amp (peak) Special Feature Proportional Controller + SSR Mounting Style Din Rail or Panel Mount Load Voltage Range 380-530VAC Max Non Repetitive Peak Voltage 600 Vp Termination Style Screw Terminals Dimensions L:81mm x W:45mm x D:73.4mm Unit Weight 296g Factory Pack Qty 20 Datasheet HS211 MCBC Series Notifications Please note Changes from Gen 3 to Gen 4 (current) package design here App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies
-
FGM6-3P-1600M 1600A, 3 Pole Moulded Case Circuit Breaker (MCCB) Thermal & Magnetic, Fixed Type ICS=65kA 1600 Amp, 400/690VAC
Heavy Item - No Free ShippingTrent FGM6-3P-1600M 1600A, 3 Pole Moulded Case Circuit Breaker (MCCB) Thermal & Magnetic, Fixed Type 65kA 1600 Amp, 400/690VAC Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a dis connector in case of electric shock Features : 3 Pole Disconnect 65kA Short Circuit Rating @400VAC Suitable for Main Incoming Breaker Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGM6-3P-1600M 1600A Functions 3 Pole MCCB Nominal Voltage 400/690VAC @ 50/60Hz Nominal Current Range 1600 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 8kV Operating Temperature -25 to 50 Deg C Mechanical Operations 20,000 Ops Insulation Voltage 800V Short Circuit Current 65kA Approvals KEMA EUR, CE Standards IEC/EN 60898-1,IEC/EN 60947-3, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 12.9kg Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet
-
FGM6S-4P-630M 630A, 4 Pole Moulded Case Circuit Breaker (MCCB) Thermal, Adjustable Type ICS=60kA 630 Amp, 400/690VAC
Heavy Item - No Free ShippingTrent FGM6S-4P-630M 630A, 4 Pole Moulded Case Circuit Breaker (MCCB) Thermal, Adjustable Type 60kA 630 Amp, 400/690VAC Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : 4 Pole Disconnect 75kA Short Circuit Rating @400VAC Suitable for Main Incoming Breaker Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGM6S-4P-630M 630A Functions 4 Pole MCCB Nominal Voltage 400/690VAC @ 50/60Hz Nominal Current Range 630 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 8kV Operating Temperature -25 to 50 Deg C Mechanical Operations 20,000 Ops Insulation Voltage 800V Short Circuit Current 60kA Approvals KEMA EUR, CE Standards IEC/EN 60898-1,IEC/EN 60947-3, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 6.9kg Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet
-
HAZ 20000-SB, Hall Effect Current Transducer, 20000A, +/-10V Instant Output, +/-15V supply
Free Aus Post Shipping for $300 SpendLEM HAZ 20000-SB, Hall Effect Current Transducer, 20000A, +/-10V Instant Output, +/-15V supply For the electronic measurement of currents: DC, AC, pulsed, mixed, with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit). Features Instantaneous output version +/-10V, +/-20mA True RMS output versions 4-20mA, 0-10V putput Hall effect measuring principle Galvanic isolation between primary and secondary circuit Instantaneous voltage output Isolation voltage 17kV Rms /50 Hz /1min Low power consumption Package in PBT meeting UL 94-V0 Instantaneous voltage output Advantages Easy installation Small size and space savings Only one design for wide Ratings range High immunity against external interference Applications Battery supplied applications Uninterruptible Power Supplies (UPS) Power supplies for welding and telecom applications Application domain Industrial Traction Specification LEM Part Number HAZ 20000-SB Technology Open Loop Hall Effect ROHS Yes Supply Voltage +/- 15VDC Load Current (RMS + DC) 20000 Amp Overload Rating 30000 At Output +/-10 V Instantaneous Isolation 17kV (AC, 50Hz, 1 min) Bandwidth DC-3kHz Mounting Style Busbar Mount Operating Temperature Range -25°C / 85°C Accuracy 1% Termination Style F2023A (FUJICON) Unit Weight 6kg Factory Pack Qty 2 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition