Search results for "루이비통카드홀더 싸싸숴러닷컴 sssreo 탤ㄹh문의 홍콩명품커스텀급 정동급 제주도최고퀄리티 미러급 레플리카 구찌보스턴백"
-
HBD41AB, Hermetic Battery Switch with Black Handle, SPST 1 x 400 Amp 1000VDC, Flange Mount 70mm Wide, M10 Terminations, OHSA
Free Aus Post Shipping for $300 SpendHBD41AB, Hermetic Battery Switch with Black Handle, SPST 1 x 400 Amp 1000VDC, Flange Mount 70mm Wide, M10 Terminations, OHSA DC battery switches are designed to be placed in between the battery and load. Suitable for any medium voltage DC application which requires up to 400Amp Continuous or 2000 Amp Overload for 1 minute. Features : 1 Pole Disconnect Suitable for 1000VDC Battery/Solar Isolation Standards : OSHA IP65 (Front) IP20 (Terminals) CE Approved Specification Iskra Systemi Part Number HBD41AB Functions 1 Pole DC SPST Disconnect Switch, ON/OFF Black Handle Nominal Voltage 1000VDC Nominal Current 1 x 400 Amp DC Rated Impulse Voltage 5kV (1 min) Rated Insulation Voltage 1000VDC Short Circuit Current 2kA (1 min) Mounting Outdoor/Indoor Panel Mount Panel Size 120 x 84.3mm Termination M10 Stud Standards OSHA, CE Weight 700g Enclosure Material Zytel Factory Pack Qty 10 Datasheet Product Datasheet
-
CTSC CLIP 600/5 Amp CLIP Splitcore CT 5VA, Class 1, 38mm Aperture
Free Aus Post Shipping for $300 SpendHobut CTSC CLIP 600/5 Series Current Transformer Features Low Price Point Split Core 1m Flying Leads Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Flame Retardent UL94V0 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Site Measurements Specification Hobut Part Number CTSC CLIP 600/5 Technology Split Core AC Current Transformer Ratio 600/5 Aperture Size ⌀ 40mm VA Rating 5VA Accuracy Class Class 1 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount Operating Temperature Range -30°C / 80°C Continuous Current (max) 600Amp x 1.2 Termination Style Screw Unit Weight 800g Factory Pack Qty 9 Datasheet Product Datasheet
-
Xmer CT Split 105/50SC 150/5 Class 1, 1.75VA, 43 x 55mm Aperture
Free Aus Post Shipping for $300 SpendXmer CT Split 105/50SC 150/5 Class 1, 1.75VA, 43 x 55mm Aperture Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Rishabh Part Number Xmer CT Split 105/50SC 150/5 Class 1 1.75VA Technology Split Core AC Current Transformer Ratio 150/5 Aperture Size 43 x 55mm VA Rating 1.75VA Accuracy Class Class 1 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -30°C / 85°C Continuous Current (max) 150Amp x 1.2 Termination Style Screw Unit Weight 800g Factory Pack Qty 9 Datasheet Product Datasheet
-
FT010030P, 100/5 Amp Split Core CT, Class 1 1VA AC Current Transformer, 20 x 30mm Aperture, Dimension 90 x 40 x 110mm
Free Aus Post Shipping for $300 SpendFT010030P, 100/5 Amp Split Core CT, Class 1 1VA AC Current Transformer, 20 x 30mm Aperture, Dimension 90 x 40 x 110mm Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number FT010030P Technology Split Core AC Current Transformer Ratio 100/5 Aperture Size 20 x 30mm VA Rating 1VA Accuracy Class Class 1 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -10°C / 50°C Continuous Current (max) 100Amp x 1.2 Termination Style Screw Approvals UL, CE Unit Weight 1150g Factory Pack Qty 1 Datasheet Product Datasheet Installation Guide
-
VA315, 1000Amp AC Clamp-On Meter. For True RMS Power Measurements, Ranges 1000VDC/700VAC/1000 Amp AC/600/1000uF/100Khz, with Diode test, Continuity Test, AUTO & MANUAL RANGING
Free Aus Post Shipping for $300 SpendVA Instruments VA315, 1000Amp AC Clamp-On Meter. For True RMS Power Measurements, Ranges 1000VDC/700VAC/1000 Amp AC/600/1000uF/100Khz, with Diode test, Continuity Test, AUTO & MANUAL RANGING For Testing of: 1000Amp AC Clamp-On Meter For True RMS Power Measurements. Ranges: DC Voltage 6/60/1000VAC +/-0.8%+5) AC Voltage 6/60/600/700VAC AC Current 600/1000A +/-3%+5 Resistance 600 Ohm/6Kohm/60KOhm/600KOhm +/-1%+3 Capacitance 600nF/6uF/60uF/600uF/1000uF +/-4%+5 Frequency 40/600/6K/60K/100KHz +/-0.1%+2 ADP Measurement 600mV +/-3%+5 Diode Test Continuity Test AUTO RANGING 225x86x32mm 40mm Diameter Jaw Requires 3 x AAA Batteries Specification Datasheet Datasheet
-
CTSC CLIP 800/5 Amp CLIP Splitcore CT 5VA, Class 1, 38mm Aperture
Free Aus Post Shipping for $300 SpendHobut CTSC CLIP 800/5 CLIP Series Current Transformer Features Low Price Point Split Core 1m Flying Leads Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Flame Retardent UL94V0 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Site Measurements Specification Hobut Part Number CTSC CLIP 800/5 Technology Split Core AC Current Transformer Ratio 800/5 Aperture Size ⌀ 40mm VA Rating 5VA Accuracy Class Class 1 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount Operating Temperature Range -30°C / 80°C Continuous Current (max) 800Amp x 1.2 Termination Style Screw Unit Weight 800g Factory Pack Qty 9 Datasheet Product Datasheet
-
HAR 1000-S O/L Current Transducer, 1000 Amp, +/-15V Supply, 54 x 18mm Square Aperture, +/-5V Output
Free Aus Post Shipping for $300 SpendHAR 1000-S O/L Hall Effect Current Sensor, 1000Amp, +/-15V Supply, 54 x 18mm Square aperture, +/-5V Output Specification LEM Part Number HAR 1000-S Technology Open Loop Hall Effect Aperture 18 x 54mm Square ROHS Yes Supply Voltage +/-15 VDC Bipolar, Isolated Load Current (RMS + DC) 50 Amp Measuring Range (Non Continuous) 2500 Amp Output +/-4 V Isolation 2.1 kV Bandwidth DC-10 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 70°C Accuracy 1% Termination Style Burndy SMS6GE4 Unit Weight 400g Factory Pack Quantity 10 Datasheet Product Datasheet
-
Xmer CT Split 105/50SC 500/5 Class 1 5VA, 43 x 55mm Aperture
Free Aus Post Shipping for $300 SpendXmer CT Split 105/50SC 500/5 Class 1 5VA, 43 x 55mm Aperture Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Rishabh Part Number Xmer CT Split 105/50SC 500/5 Class 1 5VA Technology Split Core AC Current Transformer Ratio 400/5 Aperture Size 43 x 55mm VA Rating 5VA Accuracy Class Class 1 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -30°C / 85°C Continuous Current (max) 500Amp x 1.2 Termination Style Screw Unit Weight 800g Factory Pack Qty 9 Datasheet Product Datasheet
-
Xmer CT Split 105/50SC 300/5 Class 1 5VA, 43 x 55mm Aperture
Free Aus Post Shipping for $300 SpendXmer CT Split 105/50SC 300/5 Class 1 3.75VA, 43 x 55mm Aperture Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Rishabh Part Number Xmer CT Split 105/50SC 200/5 Class 1 3.75VA Technology Split Core AC Current Transformer Ratio 300/5 Aperture Size 43 x 55mm VA Rating 5VA Accuracy Class Class 1 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -30°C / 85°C Continuous Current (max) 300Amp x 1.2 Termination Style Screw Unit Weight 800g Factory Pack Qty 9 Datasheet Product Datasheet
-
ESCT-TA24-100A/100mA + HY-2.0, 100A/100mA Measurement, Class 1 Split Core CT's
Free Aus Post Shipping for $300 SpendEastron Europe Electronics ESCT-TA24-100A/100mA + HY-2.0, 100A/100mA Measurement, Class 1 Split Core CT's Features Quick Release Split Core System Cable Mount 100mAmp Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads with HY-2.0 Connector Applications Eastron Modular Metering Equipment Energy Monitoring Load Balancing Power Quality Measurements Specification Eastron Europe Part Number ESCT-TA24-100A/100mA + HY-2.0 Technology Split Core AC Current Transformer Ratio 100/100mA Aperture Size ø 24 mm VA Rating 1VA Accuracy Class Class 1 Output 100mA (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 100Amp x 1.2 Termination Style 0.9M Flying leads with HY-2.0 Connector Unit Weight 100g Factory Pack Qty 9 Datasheet Product Datasheet Application Notes Installation Guide CRJ-31 Connector User Guide
-
FT025080P, 250/5 Amp Split Core CT, Class 1 1.5VA AC Current Transformer, 50 x 80mm Aperture, Dimension 145 x 159 x 37mm
Free Aus Post Shipping for $300 SpendFT025080P, 250/5 Amp Split Core CT, Class 1 1.5VA Series Current Transformer Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number FT025080P Technology Split Core AC Current Transformer Ratio 250/5 Aperture Size 50 x 80mm VA Rating 1.5VA Accuracy Class Class 1 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -10°C / 50°C Continuous Current (max) 250Amp x 1.2 Termination Style Screw Approvals UL, CE Unit Weight 1150g Factory Pack Qty 1 Datasheet Product Datasheet Installation Guide
-
ESCT-TA24-200A/100mA + HY-2.0, 200A/100mA Measurement, Class 1 Split Core CT's
Free Aus Post Shipping for $300 SpendEastron Europe Electronics ESCT-TA24-200A/100mA + HY-2.0, 200A/100mA Measurement, Class 1 Split Core CT's Features Quick Release Split Core System Cable Mount 100mAmp Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads with HY-2.0 Connector Applications Eastron Modular Metering Equipment Energy Monitoring Load Balancing Power Quality Measurements Specification Eastron Europe Part Number ESCT-TA24-200A/100mA + HY-2.0 Technology Split Core AC Current Transformer Ratio 200/100mA Aperture Size ø 24 mm VA Rating 1VA Accuracy Class Class 1 Output 100mA (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 200Amp x 1.2 Termination Style 0.9M Flying leads with HY-2.0 Connector Unit Weight 100g Factory Pack Qty 9 Datasheet Product Datasheet Application Notes Installation Guide CRJ-31 Connector User Guide