Crydom D2475-10, Solid State Relay, Single Phase 3-32VDC Control, 75A, 24-280VAC Load, Random Crossing
Features
• Ratings from 25A to 125 Amp @ 24-280 VAC
• SCR output for heavy industrial loads
• Zero voltage or instantaneous turn-on outputs
• UL/CSA/VDE Approved, CE Compliant to EN60950-1
• Improved SEMS screw and washer
• Redesigned housing with anti-rotation barriers
• AC & DC control types
• Direct bond copper substrate
• EMC compliant to Level 3
• Direct power lead frame
• Epoxy free design
Spec
Crydom Part Number
D2475-10
Switching Type
Random Crossing
ROHS
Yes (Details)
Control Voltage
3-32VDC
Load Current
40 Amp (rms)
Surge Capability
954 Amp (peak)
Special Feature
None
Mounting Style
Panel Mount
Load Voltage Range
24-280VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
75g
Factory Pack Qty
20
Datasheet
Product Datasheet
Please note Changes from Gen 3 to Gen 4 (current) package design here
Alternatives
See HD48125-10 or Contact Us for Possible Replacement
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Fastron Electronics FESCT-075-1000-1-IP65, 1000Amp Measurement, 1 Amp Output Split Core CT's, Class 1, 7.5VA, 7.5VA, w/10M Flying leads, ø 55mm Aperture
Features
Quick Release Split Core System
10m Flying Leads
ø 75mm
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.60/3kV
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurement, 1 Amp Outputs
Specification
Fastron Electronics Part Number
FESCT-075-1000-1-IP65
Technology
Split Core AC Current Transformer
Ratio
1000/5A
Aperture Size
ø 75mm
VA Rating
7.5VA
Accuracy Class
Class 1
Output
1 Amp (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Dimensions
180x138x52mm
Mounting Style
Panel Mount
Operating Temperature Range
-35°C / 55°C
Continuous Current (max)
1000Amp x 1.2
Termination Style
10M Twisted Pair 0.34mm^2
Unit Weight
2000g
Factory Pack Qty
9
Datasheet
Product Datasheet
Application Notes
Installation Guide
C100N+100R, RC Snubber Network 275VAC, Class X2, 100uF 100 Ohm
These snubber neworks are suitable for transient supression in small contactors, bridge rectifers, or solid state relays switching AC or DC Loads. Easily connected or lugged to solid stage relay or power module terminals. See EMC filters, and Metal Oxide Varistors sections for additional supression components.
As and added bonus, these Snubber Networks Improve the Power Factor of switched loads.
Datasheet
Product Datasheet
Infineon T298N08TOF Thyristor(SCR) Capsule
Features
Very low forward voltage drop
Very low leakage current
International standard package
41/14 Package
Press Mounted
Double or Single Sided Cooling
Applications
Power Supplies
Rectifier for drives applications
Controlled Rectifiers
AC Switch
Battery Chargers
Phase Controllers
Water Cooled AC switches
Power Factor Correction
Specification
Infineon Part Number
T298N08TOF
Vrrm
800V
SCR Configuration
Thyristor(SCR) Capsule PUK
IF(av) @ 85 Deg C
298 Amp
Package Size
ø41 x 14mm
Itsm
4.9 kA
VF(to)
.85V
Tj(max)
125°C
rF
0.9mΩ
Gate Terminals
Faston 4.8 x 0.8mm & 2.8 x 0.8mm
R th(j-c) (double sided cooled 180°sin)
0.088°C/W
R th(c-h) (double sided cooled)
0.015°C/W
Weight
300g
Clamping Force
3 - 6kN
Factory Pack Qty
12
Certification
ROHS
Infineon Headquarters
Germany
Datasheet
Product Datasheet
Alternatives
, Obsolete, See
T430N16TOF
Heatsink
Heatsink Profiles
Crydom HS211 + RPC2440, Single Phase Proportional Phase Controller with Heatsink, for 500K - 1M POT input, 90-280VAC, 27 Amps
Features
Potentiometer Proportional Phase Control Input
Ratings from 25A to 40 Amp @ 180-280 VAC
SCR output for heavy industrial loads
Zero voltage or instantaneous turn-on outputs
UL/CE/ROHS Compliant
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Panel Mount
Din Rail Mount
Spec
Part Number
HS211 + RPC2440
Switching Type
Phase Angle (Random Crossing)
ROHS/CE/UL
Yes
Control Voltage
10M Ohm Potnentiometer Proportional Input
Load Current
27 Amp (rms) @ 40 Deg C
Surge Capability
597 Amp (peak)
Special Feature
Proportional Controller + SSR
Mounting Style
Din Rail or Panel Mount
Load Voltage Range
180-280VAC
Max Non Repetitive Peak Voltage
600 Vp
Termination Style
Screw Terminals
Dimensions
L:81mm x W:45mm x D:73.4mm
Unit Weight
296g
Factory Pack Qty
20
Datasheet
HS211
RPC2440
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Fastron FC5-S-1U-1-G-2-C PID Controller, 100-240VAC with 1 Alarm, RS485, K,E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, 48x48mm,0-10V Output
4-digit displays (0.5s response)
Drip-proof / Dust-proof IP66 (front panel only)
Input signals can be converted to insulated -0-10V, Relay, 12VDC (SSR) and 4 to 20 mA DC outputs available
Each unit needs just 75 mm depth panel space
Specification
Fastron Part Number
FC5-S-1U-1-G-2-C
Control Output
0-10V
Input
Multirange K,E,J,N,T,S,R,B Thermocouple, PT100/Cu20 RTD Input/Linear Current 4(0)-20mA/Linear Voltage 0-10(5)V
Option 1
1 Alarm, RS485 standard (Excludes 48x48mm with SSR/Relay output)
Mounting Style
48 x 48mm Panel Mount
Supply Voltage
100 - 240VAC +/-10%
Termination Style
Screw
Sampling Time
100ms
Weight
150-270g
Factory Pack Qty
10
Datasheet
Datasheet
User Manual
Modbus Protocol
FC5 Communication Protocol
Fastron Electronics GT-AV6-D-4, AC Voltage Transducer, 0-300V AC input, 22-60VDC aux, 0-10V Average RMS output
Adjustable Zero and Span Setting
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space
Specification
Fastron Electronics Part Number
GT-AV6-D-4
Control Output
0-10V Average RMS
Input
0-300VAC
Over Range
x 1.5
Operating Temperature
0 - 60°C
Load Voltage
22-60VDC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
DIN Rail Mount
Case Material
PC - UL 94 V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
Crouzet 88974142, Millenium 3 Essential PLC XD10-6I/4O S, 6 x On/Off inputs, Incl 4 analogue inputs, 4 Solid State outputs incl 1 x PWM output, 24 VDC, EXPANDABLE
Highly visible blue LCD with 4 lines of 18 characters and configurable backlighting
Allow the use of the entire library of specific functions blocs of the software workshop
Extended temperature range (-20 °C →+70 °C)
Analogue inputs 0-10 VDC, Potentiometer, NTC, LDR (0-20 mA/Pt100 with converters)
Open to XN network communication extensions, digital I/O, analogue, Pt100 extensions
HMI Screens Available
Specification
Crouzet Part Number
88974142 (XD10-6I/4O S)
Analogue Inputs
0-10VDC (x4)
Digital Inputs
12/24VDC (4.4mA @ 12VDC) (x6)
Digital Outputs
4 x SSR 12/24VDC @ 500mA (x4)
PWM SSR Output
12-24VDC @ 500mA (x1)
Expandable
Yes
LCD Display
Yes
Mounting Style
DIN Rail Mount (71.2mm)
Supply Voltage Range
24VDC (21.6 - 28.8VDC)
Termination Style
Screw
Weight
250g
Certification
CE, UL, CSA, GL
Factory Pack Qty
1
Over Voltage Category
3 in accordance with IEC/EN 60664-1
Pollution Degree
2 in accordance with IEC/EN 61131-2
Protection rating
IP40 (Front), IP20 (Rear)
Mechanical Resistance
Immunity to vibrations IEC/EN 60068-2-6, test Fc
Immunity to shock IEC/EN 60068-2-27, test Ea
Resistance to HF Interference
Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12
Conducted and radiated emissions
Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure)
Operating Temperature
-20 →+70 °C except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-22
Datasheet
XD10-6I/4O Brochure
XD10-6I/4O Datasheet
Software
Crouzet Touch Soft V6.00.02.173
Software M3-soft-AC9-V3.1.2.0_ML
Remote Control Software CVD_PC_V2_3_01_02
Crouzet Soft EVO EM4 1.12.01.14
Crydom Series 1 HA4890, Solid State Relay, Single Phase 90-280VAC Control, 90A, 48-530VAC Load
Features
Ratings from 25A to 125 Amp @ 48-530VAC
SCR output for heavy industrial loads
Zero voltage or instantaneous turn-on outputs
UL/CSA/VDE Approved, CE Compliant to EN60950-1
Improved SEMS screw and washer
Redesigned housing with anti-rotation barriers
AC & DC control types
Direct bond copper substrate
EMC compliant to Level 3
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
HA4890
Switching Type
Zero Crossing
ROHS
Yes (Details)
Control Voltage
90-280VAC
Load Current
90 Amp (rms)
Surge Capability
1145 Amp (peak)
Special Feature
None
Mounting Style
Panel Mount
Load Voltage Range
48-530VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
75g
Factory Pack Qty
20
Datasheet
Product Datasheet
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
Equivalent
See HA48125 for stocked equivalent.
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
SDM630Modbus-MID-V2-CL1 (SDM630-M), DIN Rail Mount kWh Meter, 3 Phase, Class 1, 100 Amp Direct Connect input, w/ 2 x pulse outputs and RS485 Comms, MID Approved
3 x 100 amp Direct Connect
RS 485 communication up to 38,400 bit/s as standard
Optional Mbus Model available
True RMS values of currents and voltages
2 x Pulse Outputs (1 Configurable)
The meter is intended for measuring, and monitoring single-phase or electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power to the 30th Harmonic) from the measured signals.
Features :
Accuracy class 1
Measurement of Active and Reactive Power
Modbus RTU communication up to 38,400 bit/s communication
Pulse output as standard
Graphic LCD with illumination
Specification
Eastron Europe Part Number
SDM630Modbus-MID-V2-CL1 (SDM630-M)
Functions
Three Phase Energy Meter
Supply Voltage
NA
Nominal Measurement Range
415V L-L 230V L-N, 100 Amp
Maximum Measurement Range
480V L-L 230V L-N, 100 Amp
Nominal Current Input
Direct connect 3 x 100 Amp
Pulse Output
2 x Passive, (1 x Configurable 60/100/200ms)
Tariff Input
N/A
Accuracy
Class 1 (I,U,F,kW,kWh) Class 2 (Reactive)
Mounting
Din Rail
Real Time Clock
1min/month (30ppm)
Internal Memory
N/A
Dimensions
72mm x 100mm x 66mm (4 modules wide)
Isolation
4kV
RS485
2400-38400 b/s (400ms Response Time)
Weight
150g
Certification
EN 61010-1 Installation Category III
Factory Pack Qty
1
Safety
IP51(Indoor)
Enclosure Material
Noryl with fire protection to UL94-V-O. Self extinguishing
Enclosure Size
DIN 42880 4 Modules
Operating Temperature
-20 →+70 °C
Documents
Product Datasheet
User Manual
Modbus Protocol
Alternatives
WM3-6 230DB
Modbus Utility
EEM Meter Setting Software Utility
Shinko PCA1R10010 Series Digital Indicating Controllers
Program control, Fixed Point Control function are standard features
5-digit displays suit most industries including Temperature, Humidity, Pressure (0.5s response)
Time Signal Output
Drip-proof / Dust-proof IP66 (front panel only)
16-step, 16 Patterns with Interlinking pattern is a standard feature
UL/CSA Approved
Each unit needs just 60 mm depth panel space
EC Compliant (Details)
Applications
Kiln Controller
Timed Heatsink Process
Food Industry
Oven Controller
Furnace Controller
Specification
Shinko Part Number
PCA1R10010
Control Output
Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)
Number of Steps
16
Number of Patterns
16
Interlinkable
Yes
Input
Multirange (refer to datasheet)
Option 1
4-20mA Retransmission Output
Option 2
None
Mounting Style
96 x 96mm Panel Mount
Load Voltage Range
24VAC/DC
Termination Style
Screw
Weight
270g
Factory Pack Qty
1
ROHS
Yes
UL
Yes
CE
Yes
Datasheet
PCA Series Brochure
PCA Series User Manual
Shinko Product Guide
Fine Tuning Adjustments
Fastron Electronics FESCT-075-1000-5-IP65, 1000Amp Measurement, 5 Amp Output Split Core CT's, Class 1, 7.5VA, w/10M Flying leads, ø 75mm Aperture
Features
Quick Release Split Core System
10m Flying Leads
ø 75mm
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.60/3kV
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurement, 5 Amp Outputs
Specification
Fastron Electronics Part Number
FESCT-075-1000-5-IP65
Technology
Split Core AC Current Transformer
Ratio
1000/5A
Aperture Size
ø 75mm
VA Rating
7.5VA
Accuracy Class
Class 1
Output
5 Amp (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Dimensions
180x138x52mm
Mounting Style
Panel Mount
Operating Temperature Range
-35°C / 55°C
Continuous Current (max)
1000Amp x 1.2
Termination Style
10M Twisted Pair 0.34mm^2
Unit Weight
2000g
Factory Pack Qty
9
Datasheet
Product Datasheet
Application Notes
Installation Guide