Search results for "텔레@cashfilter365「:업비트코인추적테더트론매입"
-
TSFNO-105, 105 Deg C, NO Thermal Switch 10 Deg C Hysteresis, +/-2% Tolerance, Flange Mount
105 Deg C Normally Open, Thermal Switch 10 Deg C Hysteresis, +/-2% Tolerance, Flange Mount, KSD301, R20 Datasheet Product Datasheet
$8.50
$10.03 inclGST -
TSFNO-85, 85 Deg C, NO Thermal Switch 10 Deg C Hysteresis, +/-2% Tolerance, Flange Mount
85 Deg C Normally Open Thermal Switch 10 Deg C Hysteresis, +/-2% Tolerance, Flange Mount, KSD301, R20 Datasheet Product Datasheet
$8.50
$10.03 inclGST -
TSFNC-145, 145 Deg C,NC Thermal Switch 10 Deg C Hysteresis, +/-2% Tolerance, Flange Mount
145 Deg C Normally Closed, Thermal Switch 10 Deg C Hysteresis, +/-2% Tolerance, Flange Mount, KSD301, R20 Datasheet Product Datasheet
$8.50
$10.03 inclGST -
TSFNO-110, 110 Deg C, NO Thermal Switch 10 Deg C Hysteresis, +/-2% Tolerance, Flange Mount
110 Deg C Normally Open, Thermal Switch 10 Deg C Hysteresis, +/-2% Tolerance, Flange Mount, KSD301, R20 Datasheet Product Datasheet
$8.50
$10.03 inclGST -
TSFNO-125, 125 Deg C,NO Thermal Switch 10 Deg C Hysteresis, +/-2% Tolerance, Flange Mount
125 Deg C Normally Open, Thermal Switch 10 Deg C Hysteresis, +/-2% Tolerance, Flange Mount, KSD301, R20 Datasheet Product Datasheet
$8.50
$10.03 inclGST -
81505160, Valve Normally Closed Pressure Sequence 30-120 PSI
81505160 Crouzet Pressure Switch/Valve Normally Closed Pressure Sequence Valve 30-120 PSI Datasheet Product Datasheet
$867.60
$1,023.77 inclGST -
FRI8-01/0.05, Current Monitoring Relay AC 0.05 - 0.5 A, Adjustable delay 0.5 - 10 s, 1 x CO 10 Amp, Universal 24-240VAC 24VDC Aux Supply
Fastron FRI 8-01/0.05, Current Monitoring Relay AC 0.05 - 0.5 A, Adjustable delay 0.5 - 10 s, 1 x CO 10 Amp, Universal 24-240VAC 24VDC Aux Supply FRI 8 Series serves to monitor AC currents up to 16 Amp, and provides Relay alarm output with adjustable delay time 0.5 - 10s. Features : Suitable for Current Transformer Monitoring Flexible adjustment by potentiometer, choise of 6 Models: 0.05 - 0.5 A; 0.1 - 1 A; 0.2 - 2 A; 0.5 - 5 A; 0.8 - 8 A; 1.6 - 16 A Adjustable delay 0.5 - 10 s to eliminate short current peaks Possible to use current scanning from current transformer - up to 600 A Universal supply AC 24 - 240 V and DC 24 V Supply is galvanically separated from measured current Output contact: 1 x changeover 8 A 1-phase, 1-MODULE, DIN rail mounting Applications : Heating bars in sliding rails Heating cables Indication of current flow Controlling of 1-phase motor consumption Specification Fastron Part Number FRI 8-01/1 Voltage Range AC 24 - 240 V, DC 24 V (AC 50 - 60 Hz) Operating Range -15 %; ? % Current Range 0.05 - 0.5 A (AC 50 Hz) Current Trip Adjustment Potentiometer Setting Accuracy 5 % Burden max. 1.5 VA Repeatability 1 % Temperature Drift 0.1%/??C Peak Overload (10s) 1.1 x Ipn Time delay T1 max. 500 ms Time delay T2 adjustable 0.1-10 s Output ?? Number of contacts 1x changeover/ SPDT (AgNi / Silver Alloy) Rating 10 A / AC1 Breaking capacity 2500 VA / AC1, 240 W / DC Inrush current 10 A Switching voltage 250 V AC1 / 24 V DC Min. breaking capacity DC 500 mW Indication of state red LED Mechanical life 1 x 107 Electrical life (AC1) 1 x 105 Other information ?? Operating temperature -20 ... ? ??C Storage temperature -30 ... ? ??C Electrical strength 4 kV (supply - output) Operating position any Mounting DIN rail EN 60715 Protection degree IP 40 from front panel / IP 10 terminals Overvoltage cathegory III. Pollution degree 2 Max. cable size (mm )2 solid wire max. 2x2.5 or 1x4 ; with sleeve max. 1x2.5 or 2x1.5 Dimensions 90 x 17,6 x 64 mm Weight 69 g Standards EN 60255-6, EN 61010-1, RoHS Datasheet Product Datasheet Application Notes Monitoring relay FRI serves to monitor current level in single phase AC circuits. Due to its fluent adjustment of release current, it is predestined for applications with necessity of current flow indication, and can be used as precedence relay. Output relay is off in normal state. In case the set current level is exceeded, it switches. Multivoltage supply is an advantage.
$57.00
$67.26 inclGST -
FRT8-2T/W240, Double Delay On Timer 12-240 V AC/DC, 0.1s - 10 Days, 2 x SPDT 16 Amp
Fastron FRT8-2T/W240, Double Delay On Timer 12-240 V AC/DC, 0.1s - 10 Days, 2 x SPDT 16 Amp Features : Multi-range (0.1s - 10days) Multi-voltage 12 →240 V AC/DC LED status indicator Possibility of external load connection in parallel to the control input Double Delay On Energisation Specification Fastron Part Number FRT8-2T/W240 Function Delay On Timer Nominal Voltage 12 → 240 V AC/DC Digital Output 2 x C/O (SPDT) (Changeover -Single Pole), 250VAC/DC @ 16 Amp Min Breaking Current 10mA/12VDC Timing Ranges Selectable 1s - 10 Days Minimum Pulse Duration 30ms/100ms with load Repeatability 0.5% Reset Time 120ms Isolation 4kV Repetition Accuracy 0.5% Threshold Adjustment Range 10 → 100 % of the range Termination Style Screw Weight 80g Factory Pack Qty 1 Certification CE, RoHS Over Voltage Category 3 in accordance with IEC/EN 60664-1 Pollution Degree 2 in accordance with IEC/EN 61131-2 Protection rating IP40 (Front), IP20 (Rear) Mechanical Resistance Immunity to vibrations IEC/EN 60068-2-6, test Fc Immunity to shock IEC/EN 60068-2-27, test Ea Resistance to HF Interference Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12 Conducted and radiated emissions Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure) Operating Temperature -20 →+70 °C except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-22 Datasheet Product Datasheet Fastron Monitoring/Time Relays Catalogue For items in our catalogue which are not listed online please Contact Us for Possible Replacement
$62.00
$73.16 inclGST -
MSD83N16MB, Rectifier Diode 85 Amp, 1600V, M8 x 1.25 w/tail, Cathode stud
MS Power MSD83N16MB Series Stud Mount Rectifier Diode Features Full blocking capability over wide temperature range Hermetic metal case with glass insulator Threaded stud Applications Power Supplies Uncontrolled Rectifiers Oil Cooled Circuits Battery Chargers Specification MS Power Part Number MSD83N16MB Vrrm 1600V Diode Configuration Cathode Stud IF(av) @ 140 Deg C 85 Amp Itsm 1.15 kA VF(to) 0.85V Tj(max) 180°C rF 3mΩ Termination Style (Tail) 8.2mm Round Lug Termination Style (Stud) M8 x 1 Tail Length to Stud 158mm R th(j-c) 0.55°C/W R th(c-h) 0.20°C/W Weight 40g Mounting Torque 4 Nm Factory Pack Qty 10 Country Of Origin China MS Power Headquarters Germany Datasheet Product Datasheet
$23.90
$28.20 inclGST -
CWA2450E, Solid State Relay, Single Phase 18-36VAC Control, 50A, 24-280VAC Load
Crydom CWA2450E, Solid State Relay, Single Phase 18-36VAC Control, 50A, 24-280VAC Load Features Ratings from 25A to 125 Amp @ 24-280VAC SCR output for heavy industrial loads Zero voltage or instantaneous turn-on outputs UL/CSA/VDE Approved, CE Compliant to EN60950-1 Improved SEMS screw and washer Redesigned housing with anti-rotation barriers AC & DC control types Direct bond copper substrate EMC compliant to Level 3 Direct power lead frame Epoxy free design Spec Crydom Part Number CWA2450E, Switching Type Zero Crossing ROHS Yes (Details) Control Voltage 18-36VAC Load Current 50 Amp (rms) Surge Capability 850 Amp (peak) Special Feature LED Status Indicator, High Surge, Internal Over Voltage Protection Mounting Style Panel Mount Load Voltage Range 24-280VAC EMC Compliant Level 3 Termination Style Screw Unit Weight 75g Factory Pack Qty 20 Datasheet Product Datasheet Notifications Please note Changes from Gen 3 to Gen 4 (current) package design here Equivalent See CWU4850 for stocked equivalent (no overvoltage protection). App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies
$134.00
$158.12 inclGST -
H36/3000R, Heatsink 250mm x 40mm profile, 3000mm long. Raw finish. 0.49 Deg C per Watt @ 200mm
Free Aus Post Shipping for $300 SpendH36/3000R, Heatsink 250mm x 40mm profile, 3000mm long. Raw finish. 0.49 Deg C per Watt @ 200mm Product datasheet
-
Power Rail 350-M2, kWh Meter, 3 Phase, DIN Rail, 240VAC aux, Class 1, 5Amp input, w/ pulse output, Power quality measurements
Free Aus Post Shipping for $300 SpendNorthern Design Power Rail 350-M2 Three Phase Power Meter 5 Amp CT Input Optional RS 232/RS 485 communication up to 19,200 bit/s True RMS values of currents and voltages Power Quality Measurements The meter is intended for measuring, and monitoring single-phase or electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, Hours Run, Peak Demand etc to the 30th Harmonic) from the measured signals. Features : Accuracy class 1 Measurement of Active and Reactive Power Optional MODBUSRS 232/RS 485 communication up to 19,200 bit/s communication Pulse output as standard Graphic LCD with illumination Specification Northern Design Part Number Power Rail 350-M2 Functions Three Phase Energy Meter Supply Voltage 230V L-N, 5 Amp +/-15% < 5VA Nominal Measurement Range 415V L-L 230V L-N, 5 Amp +/-15% Maximum Measurement Range 480V L-L 230V L-N, 5 Amp +/-15% Nominal Current Input 5 Amp AC Pulse Output 3 x NO Voltage Free Contacts 100mA @ 100VAC/DC Accuracy Class 1 (I,U,F,PF,) Class 2 (Reactive) Mounting Din Rail Real Time Clock 1min/month (30ppm) Internal Memory N/A Dimensions 106mm x 90mm x 58mm (6 modules wide) Isolation 3.5kV RS232/RS485 (Optional 1200-19200 b/s) Weight 150g Certification EN 61010-1 Installation Category III Factory Pack Qty 1 Enclosure Material Noryl with fire protection to UL94-V-O. Self extinguishing Enclosure Size DIN 42880 6 Modules Operating Temperature -20 →+70 °C Datasheet Product Datasheet Product Manual Product Comms Manual Option Links Application Notes CT Cable Losses Meter Accuracy at Low Current Current Input Isolation
Free Aus Post Shipping for $300 Spend$298.00
$351.64 inclGST