Crydom ED06D5, EMR plug in Solid State Relay, 5-15VDC control, 5 Amp 1-48V DC output
Features
Ratings 5 Amp @ 60/80VDC
Plug in EMR relay style
Motor controller rated
Mosfet output for reliable DC switching
Multiple modules can be wired in parallel for higher currents
UL/CSA/VDE Approved, CE Compliant to EN60950-1
EMC compliant to Level 3
Epoxy free design
Spec
Crydom Part Number
ED06D5
Switching Type
DC Load
ROHS
Yes (Details)
Control Voltage
5-15VDC
Load Current
5 Amp DC
Surge Capability (10ms)
60 Amp DC
Special Feature
Plug in EMR style
Mounting Style
EMR Base
Load Voltage Range
1 - 48VDC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
11g
Factory Pack Qty
20
Datasheet
Product Datasheet
Socket
DRSED
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
MS Power MSD83N16MB Series Stud Mount Rectifier Diode
Features
Full blocking capability over wide temperature range
Hermetic metal case with glass insulator
Threaded stud
Applications
Power Supplies
Uncontrolled Rectifiers
Oil Cooled Circuits
Battery Chargers
Specification
MS Power Part Number
MSD83N16MB
Vrrm
1600V
Diode Configuration
Cathode Stud
IF(av) @ 140 Deg C
85 Amp
Itsm
1.15 kA
VF(to)
0.85V
Tj(max)
180°C
rF
3mΩ
Termination Style (Tail)
8.2mm Round Lug
Termination Style (Stud)
M8 x 1
Tail Length to Stud
158mm
R th(j-c)
0.55°C/W
R th(c-h)
0.20°C/W
Weight
40g
Mounting Torque
4 Nm
Factory Pack Qty
10
Country Of Origin
China
MS Power Headquarters
Germany
Datasheet
Product Datasheet
MS Power MSD83R16UB, Rectifier Diode 83 Amp, 1600V, 1/4" UNF, Anode stud
Features
Full blocking capability over wide temperature range
Hermetic metal case with glass insulator
Threaded stud
Applications
Power Supplies
Uncontrolled Rectifiers
Oil Cooled Circuits
Battery Chargers
Specification
MS Power Part Number
MSD83R16UB
Vrrm
1600V
Diode Configuration
Anode Stud
IF(av) @ 140 Deg C
85 Amp
Itsm
1.15 kA
VF(to)
0.85V
Tj(max)
180°C
rF
3mΩ
Termination Style (Tail)
8.2mm Round Lug
Termination Style (Stud)
1/4" 28UNF 2A
Tail Length to Stud
158mm
R th(j-c)
0.55°C/W
R th(c-h)
0.20°C/W
Weight
40g
Mounting Torque
4 Nm
Factory Pack Qty
10
Country Of Origin
China
MS Power Headquarters
Germany
Datasheet
Product Datasheet
Crydom CWA2450E, Solid State Relay, Single Phase 18-36VAC Control, 50A, 24-280VAC Load
Features
Ratings from 25A to 125 Amp @ 24-280VAC
SCR output for heavy industrial loads
Zero voltage or instantaneous turn-on outputs
UL/CSA/VDE Approved, CE Compliant to EN60950-1
Improved SEMS screw and washer
Redesigned housing with anti-rotation barriers
AC & DC control types
Direct bond copper substrate
EMC compliant to Level 3
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
CWA2450E,
Switching Type
Zero Crossing
ROHS
Yes (Details)
Control Voltage
18-36VAC
Load Current
50 Amp (rms)
Surge Capability
850 Amp (peak)
Special Feature
LED Status Indicator, High Surge, Internal Over Voltage Protection
Mounting Style
Panel Mount
Load Voltage Range
24-280VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
75g
Factory Pack Qty
20
Datasheet
Product Datasheet
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
Equivalent
See CWU4850 for stocked equivalent (no overvoltage protection).
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Rishabh CT 50/5 Class 1 1VA 50/21 (30) Series Current Transformer
Features
DIN Rail Mounting Clip Included
Built In Sealable Terminal Covers
Mounting Feet Supplied
Narrow Width (45mm)
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Rishabh Part Number
CT 50/5 Class 1 1VA 50/21 (30)
Technology
AC Current Transformer
Ratio
50/5
Aperture Size
⌀ 21mm or 20x10mm Busbar
VA Rating
1VA
Accuracy Class
Class 1
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Din Rail Mount
Operating Temperature Range
-30°C / 85°C
Continuous Current (max)
150Amp x 1.2
Termination Style
Screw
Unit Weight
300g
Factory Pack Qty
9
Datasheet
Product Datasheet
HS103DR-A53TP50D, Solid State Relay, and Heatsink Assembly, 3 Phase 90-280VAC Control, 19.33 Amp per phase @ 40 Deg C, 48-530VAC Load, LED Status Indicator @ 40 Deg C
Features
Ratings from 25A to 50 Amp @ 70-530 VAC
SCR output for heavy industrial loads
Zero voltage or Instantaneous turn-on outputs
UL/CE/ROHS Approved
IP20 Cover Available
AC & DC control types
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
HS103DR + A53TP50D
Switching Type
Zero Crossing
ROHS/CE/UL
Yes
Control Voltage
90-280VAC
Load Current
3 x 21 Amp (rms) per Phase
Surge Capability
597 Amp (peak)
Special Feature
LED Status Indicator
Mounting Style
Din Rail Mount
Load Voltage Range
48-530VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
315g
Factory Pack Qty
10
Datasheet
HS103DR
A53TP Series
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Gigavac GX46CDB, Contactor SPST-NO, 600+ AMP, 12-800VDC, 12VDC Coil, Coil Screw M4, SPST-NO Auxiliary Contact, IP67, IP69K
Features
Hermetically Sealed (Patented) rated to 175 Deg C
UL1604 for Class I & II Div 2 and Class III for use in hazardous locations
IP67 & IP69K
SAE J1171 External ignition protection
ISO8846 Protection against ignition around flammable gasses
CE Approved
High Efficiency Dual DC Coils - Very low 12,24,48VDC continuous coil power with no EMI emissions or cross-talk on your system control power
Ideal for battery powered systems or where low power is needed
PWM option provides additional drive control flexibility
Built in Coils suppression for all DC Coils
Flexible package for installation
Chassi level power terminals
Salt Fog MIL-STD-810
Specification
Gigavac Part Number
GX46CDB
Main Contact Type
SPST-NO
Auxiliary Contact Type
SPST-NO
Coil Voltage
24VDC
Load Current
600+ Amp
Mechanical Life @ 0 Amp
1,000,000 Operations
Dielectric at Sea Level (leakage <1mA)
2.2kV rms
Control Input Terminals
M4 Screw
Aux Contact Terminals
M4 Coil Screw
Special Feature
Hermetically Seal rated to 175 Deg C
Mounting Style
Panel Mount (M5)
Load Voltage Range
12-800VDC
Standards
UL1604, IP67, IP69K, SAE J1171, ISO8846
Termination Style
M8
Unit Weight
900g
Factory Pack Qty
1
Datasheet
Product Datasheet
Northern Design Multicube Modular Master Single and 3 Phase Power Meter with Logger and Modbus TCP/IP Comms, NEW WEB PAGE VERSION
Up to 20 Meters in 1 with additional modules
Minimum 2 x 3 Phase Circuits with measurement module
Master Unit of Modular Multicube System
Optional 12 way pulse/alarm digital output modules
Nominal current up to 0.383V (For 0.333V CT Input) and nominal voltage up to 240V L-N 415V L-L
Graphic Display
Optional RS485 or Ethernet communication up to 19,200 bit/s
True RMS measurement of currents and voltages
The meter is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, reactive power, power factor, harmonics, etc.) from the measured signals.
Features :
20 Meters in same space as 4 traditional meters
Expandable to 20 x 3 Phase or 60 x Single Phase Circuits
Accuracy class 1
In Built Logger
Simple Menu
Optional MODBUS TCP/IP/Ethernet communication
5 Year Warranty
240V AC power supply
Specification
Northern Design Part Number
Multicube Modular Master with Logger and TCP/IP
Functions
kWh Meter, Energy Meter, Power Quality, Network Recorder
Supply Voltage
240VAC < 15VA
Nominal Measurement Range
415V L-L 240V L-N, 0.333V
Maximum Measurement Range
480V L-L 280V L-N, 0.383V
Display
Graphic LCD
Pulse Output
12 (Optional)
Accuracy
Class 1 (kW,kWh) Class 1(Active), Class 2 Reactive
Ethernet
Yes
Logger
Yes
Isolation
2.11kV
RS232/RS485
Modbus TCP/IP
Weight
900g
Certification
EN 61010-1 Installation Category III
Factory Pack Qty
1
Environment
IP54
Safety
Protection Class II
Enclosure Material
ABS with fire protection to UL94-V-O. Self extinguishing
EnclosureSize
164 x 96mm x 100mm
Terminals
Rising Cage 4mm² (12 AWG) cable max
Humidity
< 75% Non Condensing
Operating Temperature
-20 →+70 °C
Datasheet
Product brochure
User manual
Wiring Diagram
Suitable 0.333V CT's
Split Core CT's
Schurter 3-122-074, V-Lock IEC Appliance Plug C13/F, Black, for 3 x 1.5m sqr/14AWG Maximum wire size
Features
Panel Mount : Snap-in Mounting from Front Side
Appliance Inlet C13 Plug acc to IEC 60320-1
Screw On Mounting
70 °C pin Temperature
Characteristics
UL 60320-1, CSA C22.2 no. 60320-1 (for hot conditions) pin-temperature 120 °C, 10A, Protection Class I
Other Pin versions available on request
Types for enhanced glow wire test requirements acc. IEC 60695-2- 12 and -13 for the use in unattended household equipment acc. IEC 60335-1
Specification
Schurter Part Number
3-122-074
Rated Voltage
250V
Rated Current
10A (CE) 15A (UL/CSA)
Operating Temperature
-25°C to 70°C
Mounting
Wire Screw Mount
Material
Thermoplastic, black, UL 94V-0
Termination Style
C13 Female Screw Terminal
Weight
40g
Factory Pack Qty
1
Protection Class
From front side IP30 acc. to IEC 60529
Isolation
2kV
VDE/UL/CSA/CE/ROHS
Yes
Datasheet
Product Datasheet