FPT-100 1500/5A 5P20 5VA, Protection Class CT, 1500/5A, Class 5P20 15VA, 103 x 64mm Aperture
Features
Built In Sealable Terminal Covers
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
VDE0414-44-1, GB1208-2006, EN 60044-1 and IEC 61869-2
Applications
Protection Relays
Safety Equipment
Fault Monitoring
Specification
Fastron Electronics Part Number
FPT-100 1500/5A 5P20 5VA
Technology
Protection Class Current Transformer
Ratio
1500/5
Aperture Size
103 x 64mm
VA Rating
15VA
Accuracy Class
Class 5P20
Output
5 Amp AC
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-10 Deg C / 50 Deg C
Continuous Current (max)
1500Amp x 1.3
Termination Style
Screw
Stanbards
VDE0414-44-1, GB1208-2006, EN 60044-1 and IEC 61869-2
Unit Weight
1.5 kg
Factory Pack Qty
1
Datasheet
Product Installation Guide and Datasheet
Fastron Electronics FEFC203-80-T, 2 Stage EMI (RFI) Input [Inverter] Output [NON Inverter] Sine Wave Filter for 3-phase systems, 80 Amp, 400VAC
Features
Suitable alternative to Schaffner FN3258(Input) or FN5020(Output) Series
3 phase Output Sine wave filter with high attenuation
400VAC +10%
Applications
Input of VSD Drives or Controlled Rectifiers
Diesel Generator Output
CNC Machinese
Elevators
Power Supplies
For Industrial Applications
Suitable for use in equipment according to IEC/UL 60950
Medical Version Available
Specification
Fastron Part Number
FEFC203-80-T
Rated Voltage
400V
Rated Current
80A
Filter Stages
2 Stage (3 Phase 3 wire)
Operating Temperature
-25°C to 85°C
Filter Type
Excellent Attenuation for Sine Wave Output, Moderate Attenuation for input Line Filtering
Leakage Current
N/A
Mounting
Panel Mount - Case 32-7
Material
Metal
Termination Style
Screw
Weight
4.5kg
Factory Pack Qty
1
Protection Class
From front side IP 40 acc. to IEC 60529
Isolation
2.2kV
CE, ROHS
Yes
Datasheet
Product Datasheet
TRENT TGD-2PL C 16-10kA, 2 Pole Miniature Bidirectional DC Circuit Breaker C Curve 16 Amp, 10kA, 500VDC
Miniature DC Circuit Breakers are used for over current (overload and short circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
< 50mS Trip Delay Time
2 Pole Disconnect
10kA Short Circuit Rating
Suitable for Isolation
Customised versions available
Type B, C, D Curve available
Bidirectional
Standards :
IEC/EN 60898
IEC/EN/AS60898-1
IP20 (IP40 Installed) IEC 61008
CE,CB, RCM (Pending)
Specification
TRENT Part Number
TGD-2PL C 16-10kA
Functions
2 Pole MCB - C Curve
Nominal Voltage
500VDC @ 50/60Hz
Nominal Current Range
16 Amps RMS
Trip Delay Time
< 50ms
Rated Impulse Voltage
6kV
Operating Temperature
-25 to 40 Deg C
Mechanical Operations
10,000 Ops
Insulation Voltage
690V
Breaking Capacity
10kA
Approvals
CE,CB, RCM (Pending)
Standards
IEC/EN/AS60898-1, IP20 (IP40 Installed) IEC 61008 ;
Weight
350g
Enclosure Material
UL94
Factory Pack Qty
1
TRENT Headquarters
Australia
Datasheet
Product Datasheet
Fastron Electronics F13FT-2PL 12A 24VDC Series Dual 12 Amp DPDT Form C AC/DC Relay, 240VAC Coil, PCB or Socket Mount
Features
2 x 12 Amp @ 250VAC or 30VDC
PCB or Socket Mount
Changeover Contact
Compatible with Omron G2R-2-S Series
UL Approved
CE Compliant to IEC 60664
IP20
Suits F13F-2Z-C4 Socket
Specification
Fastron Part Number
F13FT-2PL 12A 24VDC
Switching Type
2 x 30VDC or 250VAC C/O DPDT Form C
Approvals
UL,CE
Control Voltage
24VDC
Load Current
2 x 12 Amp (rms)
Special Feature
LED Status Indicator
Load Voltage Range
0-250VAC, 0-30VDC
Isolation
2.5kV
Termination Style
PCB or Socket Mount
Unit Weight
38g
Factory Pack Qty
20
Datasheet
Relay Datasheet
Replacement Socket
F13F-2Z-C4
Fastron Electronics FEFC203-200-T, 2 Stage EMI (RFI) Input [Inverter] Output [NON Inverter] Sine Wave Filter for 3-phase 3 wire systems, 200 Amp, 400VAC
Features
Suitable alternative to Schaffner FN3258(Input) or FN5020(Output) Series
3 phase Input [Inverter] Output [NON Inverter] Sine Wave Filter with standard attenuation
400VAC +10%
Applications
Input of VSD Drives or Controlled Rectifiers
Diesel Generator Output
CNC Machinese
Elevators
Power Supplies
For Industrial Applications
Suitable for use in equipment according to IEC/UL 60950
Medical Version Available
Specification
Fastron Part Number
FEFC203-200-T
Rated Voltage
400V
Rated Current
200A
Filter Stages
2 Stage (3 Phase 3 wire)
Operating Temperature
-25°C to 85°C
Filter Type
Excellent Attenuation for Sine Wave Output, Moderate Attenuation for input Line Filtering
Leakage Current
N/A
Mounting
Panel Mount - Case 32-7
Material
Metal
Termination Style
Screw
Weight
4.5kg
Factory Pack Qty
1
Protection Class
From front side IP 40 acc. to IEC 60529
Isolation
2.2kV
CE, ROHS
Yes
Datasheet
Product Datasheet
Fastron FPC1-AUX-20-CTS Auxiliary Contact for FPC1 Series NON HUM FREE Contactors 2 x NO, 5 Amp @ 230VAC/ 1 Amp @ 130VDC. Side/Din Rail Mount
Features
UL94V0
IP20
Specification
Fastron Part Number
FPC1-AUX-20-CTS
Switching Type
2 x SPST NO
Approvals
CE
Coil Voltage
N/A
Load Rating
5 Amp @ 230VAC/ 1 Amp @ 130VDC
Special Feature
Auxiliary Contact for NON HUM FREE Contactors
Mounting Style
DIN Rail Mount
Load Voltage Range
N/A
Isolation
4kV
Unit Weight
40g
Factory Pack Qty
120
Datasheet
Datasheet
Auxiliary Contacts Selection Guide
Trent FGM6DC-2PL-320 250A, 2 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 20kA 250 Amp, 1000VDC
Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
2 Pole Disconnect
20kA Short Circuit Rating @1000VDC
Suitable for DC Power Systems Including Solar and Battery
Standards :
IEC/EN 60947-3
IP20 (IP40 Installed) IEC 61008
Specification
Trent Part Number
FGM6DC-2PL-320 250A
Functions
2 Pole DC MCCB
Nominal Voltage
1000VDC
Nominal Current Range
250 Amps
Trip Delay Time
< 50ms
Rated Impulse Voltage
12kV
Operating Temperature
-35 to 70 Deg C
Electrical Operations
5,000 Ops
Insulation Voltage
1500V
Short Circuit Current Ics=Icu (Ics/Icu)
20kA
Approvals
CE
Standards
GB/T14048.2, IEC/EN 60947-3, IP20 (IP40 Installed)
Weight
2.2kg
Enclosure Material
UL94
Factory Pack Qty
1
Datasheet
Product Datasheet
CE Declaration
Trent FGM6DC-2PL-320 200A, 2 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 20kA 200 Amp, 1000VDC
Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
< 50mS Trip Delay Time
2 Pole Disconnect
20kA Short Circuit Rating @400VAC
Suitable for DC Power Systems Including Solar and Battery
Standards :
IEC/EN 60947-3
IP20 (IP40 Installed) IEC 61008
Specification
Trent Part Number
FGM6DC-2PL-320 200A
Functions
2 Pole DC MCCB
Nominal Voltage
1000VDC
Nominal Current Range
200 Amps
Trip Delay Time
< 50ms
Operating Temperature
-35 to 70 Deg C
Electrical Operations
5,000 Ops
Insulation Voltage
1500V
Short Circuit Current Ics=Icu (Ics/Icu)
20kA
Approvals
CE
Standards
GB/T14048.2, IEC/EN 60947-3, IP20 (IP40 Installed)
Weight
2.2kg
Enclosure Material
UL94
Factory Pack Qty
1
Datasheet
Product Datasheet
CE Declaration
SI-102-4-1-H, Signal Isolator/Conditioner, 0-10V input, 85-300VAC/DC aux, 2 x 0-10V outputs, Fixed zero and span
Fixed Zero and Span Setting
150mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space
Specification
Fastron Electronics Part Number
SI-102-4-1-H
Control Output
2 x 0-10V
Input
0-10V
Over Range
x 1.5
Operating Temperature
0 - 60°C
Load Voltage
85-300VAC/DC
Span Adjustment Range
Fixed
Zero Adjustment Range
Fixed
Termination Style
Screw
Mounting Style
DIN Rail Mount
Case Material
PC - UL 94 V0
Weight
170g
Factory Pack Qty
1
Datasheet