MT440-SSUDAANNA, Multifunction Power Transducer, Class 0.5, 4 Wire, 600V L-N, 1/5/10Amp AC Input 50/60Hz, 24-300VDC or 40-276VAC Aux Input, 2 Programmable analogue outputs, RS485 & USB Comms
Free Aus Post Shipping for $300 SpendIskra Doo MT440-SSUDAANNA, Multifunction Power Transducer, Class 0.5, 4 Wire, 600V L-N, 1/5/10Amp AC Input 50/60Hz, 24-300VDC or 40-276VAC Aux Input, 2 Programmable analogue outputs, RS485 & USB Comms Class 0.5 (EN 60688) USB Comms as standard Up to 4 I/O Modules (analogue output, Multiple break point, non-linear characterstics Automatic range of nominal current up to 12.5 A (Includes 5A/1A CT Input) and nominal voltage up to 600 V L-N Adjustable tariff clock, display of electric energy consumption in optional currency RMS values of currents and voltages Measurements of active, reactive, apparent power and power factor Measurements of energy in all 4 quadrants Average values of measurands per interval Certified ship version available The Power Transducer is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals. Features : Measurement of instantaneous values of more than 50 quantities (U, I, P, Q, S, PF, PA, f, f, MD, etc.). Accuracy class 0.5 32 Adjustable Alarms Input frequency 50/60 Hz or 400 Hz RS 232/RS485 communication up to 115,200 bit/s (Optional) or USB communication as standard MODBUS RTU communication protocol Up to 4 inputs or outputs (pulse outputs, alarm outputs, tariff inputs) Universal Supply 24-300VDC or 40-276VAC Automatic range of nominal current up to 12.5 A and nominal voltage up to 600 V User-friendly PC MiQen software Specification Iskra Doo Part Number MT440-SSUDAANNA Functions 3 Phase Power Transducer Supply Voltage 24-300VDC or 40-276VAC Nominal Measurement Range 600V L-N, 1/5/10 Amp Maximum Measurement Range 600V L-N, 12.5 Amp Alarm N/A Tariff Input N/A Output(s) 2 x Analogue Accuracy Class 0.5 (I,U,F,PF,θ,THD) Class 1(Active), Class 2 (Reactive) Battery Backup N/A Real Time Clock 1min/month (30ppm) Isolation 3.5kV Comms USB (standard) RS232 2400-115200 b/s (RS485 Optional) Weight 370g Enclosure Material UL94, Factory Pack Qty 1 EU Directives EN61010, EN60688,EN61326-1,60529,60068-2-1/-2/-6/-27/-30 Safety Protection Class II 600V rms, installation category II 300V rms, installation category III Pollution Degree 2 in compliance with SIST EN 61010-1:2002 Enclosure Material PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP20 Shock Withstand 300g 8ms Pulse . 6 Shocks in each of 3 axes Vibration Withstand 0.7g, 3...100Hz, 1oct/min 10 cycles in each of three axes Operating Temperature -20 →+70 °C Datasheet Product Datasheet Software MiQen Setting Software MIPACK Programmer
-
DK 20 C420 U, Hall Effect DC Current Transducer, 5, 10, 20A DC, 4-20mA Unipolar Output, 20-50VDC supply
Free Aus Post Shipping for $300 SpendLEM DK 20 C420 U, Hall Effect DC Current Transducer, 5, 10, 20A DC, 4-20mA Unipolar Output, 20-50VDC supply Compact and versatile Split Core DC current sensor, selectable 5, 10, 20Amp DC. Choice of output types: 0-20mA, 4-20 mA, 0-5 V or 0-10 V Features ⌀19.1mm Aperture DC Bipolar Measurement 4-20mA analogue output Busbar, or panel mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification LEM Part Number DK 100 C420 U Technology DC Current Transformer with Process Output ROHS Yes Supply Voltage 20-50VDC Nominal Current (RMS + DC) 5,10,20 Amp Selectable Response Time < 100ms Output Unipolar 4-20mA Analogue Isolation 3kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 2% Termination Style 2 x UNC8 Cylindric Head Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
RQS40L024DC0T, Quad Output Relay, 4 x 5 Amp C/O, 250VAC/30VDC Load, 24VDC Coil
Free Aus Post Shipping for $300 SpendRelequick RQS40L024DC0T Series Quad 4 x 5Amp Din Rail Mount AC/DC Relay, 24VDC Coil Features 4 x 5 Amp @ 250VAC or 30VDC DIN Rail Mount Changeover Contact Ultra slim package CE Compliant to IEC 60664 IP67 Suits SQB41D00T Socket Specification Relequick Part Number RQS40L024DC0T Switching Type 4 x 30VDC/250VAC C/O No of Pins 14 Approvals UL, CE Control Voltage 24VDC Load Current 4 x 5 Amp (rms) Special Feature LED Status Indicator Mounting Style DIN Rail Mount Load Voltage Range 0-250VAC, 0-30VDC Termination Style PCB or Socket Mount Unit Weight 38g Factory Pack Qty 20 Datasheet Relay Datasheet
-
BH-25-2-24, Split Core Hall Effect DC Current Transducer, +/-25 Amp DC, 4-20mA Bipolar output, 31mm aperture, 24VDC supply
BH-25-2-24, Split Core Hall Effect DC Current Transducer, +/-25 Amp DC, 4-20mA Bipolar output, 31mm aperture, 24VDC supply Compact and versatile Split Core DC current sensor, +/-25 Amp DC, 4-20mA Bipolar Output Features ⌀31mm Aperture Split Core DC Bipolar Measurement 4-20mA analogue output Busbar, or DIN Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Mount Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number BH-25-2-24 Technology DC Hall Effect Current Transducer with Process Output ROHS Yes Supply Voltage 24VDC Nominal Current (DC) +/-25 Amp DC Response Time < 200mS Output Bipolar 4-20mA Analogue Isolation 2.5kV (AC, 25Hz, 1 min) Bandwidth DC Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Screw Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet
$425.00
$501.50 inclGST -
BH-10-2-24, Split Core Hall Effect DC Current Transducer, +/-10 Amp DC, 4-20mA Bipolar output, 31mm aperture, 24VDC supply
BH-10-2-24, Split Core Hall Effect DC Current Transducer, +/-10 Amp DC, 4-20mA Bipolar output, 31mm aperture, 24VDC supply Compact and versatile Split Core DC current sensor, +/-10 Amp DC, 4-20mA Bipolar Output Features ⌀31mm Aperture Split Core DC Bipolar Measurement 4-20mA analogue output Busbar, or DIN Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Mount Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number BH-10-2-24 Technology DC Hall Effect Current Transducer with Process Output ROHS Yes Supply Voltage 24VDC Nominal Current (DC) +/-10 Amp DC Response Time < 200mS Output Bipolar 4-20mA Analogue Isolation 2.5kV (AC, 10Hz, 1 min) Bandwidth DC Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 2% Termination Style Elevator Screw Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet
$425.00
$501.50 inclGST -
MT550-SSHFNAASS (DIN), Multifunction Power Transducer, Class 0.1, 4 Wire, 50-500V L-N, 5A AC Input 16-400Hz, 70-300VDC or 80-276VAC Aux Input, 2 Programmable analogue outputs, 2 Pulse Outputs, USB, Ethernet, RS485 Comms
Free Aus Post Shipping for $300 SpendIskra Doo MT550-SSHFNAASS (DIN), Multifunction Power Transducer, Class 0.1, 4 Wire, 50-500V L-N, 5A AC Input 16-400Hz, 70-300VDC or 80-276VAC Aux Input, 2 Programmable analogue outputs, 2 Pulse Outputs, USB, Ethernet, RS485 Comms Class 0.1 Active, Class 0.2 Reactive (EN 60688) RS485 Comms as standard Up to 4 I/O Modules (analogue output, Multiple break point, non-linear characterstics Automatic range of nominal current up to 12.5 A (Includes 5A/1A CT Input) and nominal voltage up to 600 V L-N Adjustable tariff clock, display of electric energy consumption in optional currency RMS values of currents and voltages Measurements of active, reactive, apparent power and power factor Measurements of energy in all 4 quadrants Average values of measurands per interval Certified ship version available The Power Transducer is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals. Features : Measurement of instantaneous values of more than 140 quantities (U, I, P, Q, S, PF, PA, f, f, MD, etc.). Accuracy Class 0.5s Active, Class 0.2 Reactive (EN 60688), Class 0.1 on Comms 32 Adjustable Alarms Input frequency 50/60 Hz or 400 Hz RS 232/RS485 communication up to 115,200 bit/s (Optional) or USB communication as standard MODBUS RTU communication protocol Up to 4 inputs or outputs (pulse outputs, alarm outputs, tariff inputs) Universal Supply 24-300VDC or 40-276VAC Automatic range of nominal current up to 12.5 A and nominal voltage up to 600 V User-friendly PC MiQen software Optional Remote Display Support Specification Iskra Doo Part Number MT550-SSHFNAASS (DIN) Functions 3 Phase Power Transducer Supply Voltage 24-300VDC or 40-276VAC Nominal Measurement Range 500V L-N, 5 Amp Maximum Measurement Range 600V L-N, 12.5 Amp Alarm N/A Tariff Input N/A Output(s) 2 x Analogue Accuracy Class 0.2 (I,U,F,PF,θ,THD) Class 0.1(Active), Class 0.2 (Reactive) Battery Backup N/A Real Time Clock 1min/month (30ppm) Terminations EU Style Clamp Terminals Isolation 3.5kV Comms USB (standard) RS232 2400-115200 b/s (RS485 Optional) Weight 900g Enclosure Material UL94, Factory Pack Qty 1 EU Directives EN61010, EN60688,EN61326-1,60529,60068-2-1/-2/-6/-27/-30 Safety Protection Class II 600V rms, installation category II 300V rms, installation category III Pollution Degree 2 in compliance with SIST EN 61010-1:2002 Enclosure Material PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP20 Shock Withstand 300g 8ms Pulse . 6 Shocks in each of 3 axes Vibration Withstand 0.7g, 3...100Hz, 1oct/min 10 cycles in each of three axes Operating Temperature -20 →+70 °C Datasheet Product Datasheet Software MiQen Setting Software
-
FTA-050-420B-24, Hall Effect DC Current Transducer, +/-50 Amp , 4-20mA Bipolar Output, 24VDC supply, 21mm Aperture
FTA-050-420B-24, Hall Effect DC Current Transducer, +/-50 Amp , 4-20mA Bipolar Output, 24VDC supply, 21mm Aperture Compact and versatile Split Core DC current sensor, +/-50 Amp , 4-20mA Bipolar Output Features ⌀21mm Aperture DC Bipolar Measurement 4-20mA Instantaneous output 120mS Response (for 0- +/-10mA ~+/-10A AC) 10uS Response (0-+/-50A ~+/-100A AC) Panel mount Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number FTA-050-420B-24 Technology DC Hall Effect Current Transducer with Instant Output Yes Supply Voltage 24VDC Nominal Current (RMS + DC) +/-50 Amp Response Time < 10uS Output Bipolar 4-20mA Instant Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Aperture 20mm Mounting Style Panel Mount Operating Temperature Range -10°C / 85°C Accuracy 1% Termination Style 4 Pin Plug (Included) Unit Weight 300g Factory Pack Qty 6 Datasheet Product Datasheet
$285.00
$336.30 inclGST -
SKiiP 24AC12T4V1, IGBT Trench 4, H Bridge, 50Amp, 1200V
Semikron SKiiP 24AC12T4V1, IGBT Trench 4, H Bridge, 50Amp, 1200V Features IGBT & Diode Rectifier with Chopper/Brake Pressure Contact Technology Electrically insulated base plate Press Mounted Style 2500V Isolation 61mm Base Width Applications Frequency Converter Line rectifying 50/60 Hz Deep Cycle Applications Controlled Rectifiers Inverter Drives Specification Semikron Part Number SKiiP 24AC12T4V1 Vces 1200V Transistor Configuration H Bridge IGBT Module Ic(nom) @ 80 Deg C 90 Amp Package Size W:81.5mm L:58.5mm D:16mm Terminals M6 Screw Mounting 2 x M12 Weight 100g Mounting Torque 5 Nm (4 Nm Terminals) Factory Pack Qty 10 Certification UL Listed, ROHS Semikron Headquarters Germany Datasheet Product Datasheet Alternatives No Alternative
$174.00
$205.32 inclGST -
FTA-050-010-24, Hall Effect DC Current Transducer, +/-50 Amp , +/-10VDC Output, 24VDC supply, 21mm Aperture
FTA-050-010-24, Hall Effect DC Current Transducer, +/-50 Amp , +/-10VDC Output, 24VDC supply, 21mm Aperture Compact and versatile Split Core DC current sensor, +/-50 Amp , +/-10VDC Bipolar Output Features ⌀21mm Aperture DC Bipolar Measurement +/-10VDC Instantaneous output 120mS Response (for 0- +/-10mA ~+/-10A AC) 10uS Response (0-+/-50A ~+/-100A AC) Busbar, or panel mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number FTA-050-010-24 Technology DC Hall Effect Current Transducer with Instant Output Yes Supply Voltage 24VDC Nominal Current (RMS + DC) +/-50 Amp Response Time < 10uS Output Bipolar +/-10VDC Analogue Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Aperture 20mm Mounting Style Panel Mount Operating Temperature Range -10°C / 85°C Accuracy 1% Termination Style 4 Pin Plug (Included) Unit Weight 300g Factory Pack Qty 6 Datasheet Product Datasheet
$285.00
$336.30 inclGST -
MG73BQ 3 Phase 4 Wire or Single Phase Voltage Monitoring Relay With DPDT Contacts, Undervoltage, Selectable Overvoltage, 3 x 120-240 VAC
Free Aus Post Shipping for $300 SpendGIC Controls MG73BQ 3 Phase 4 Wire or Single Phase Voltage Monitoring Relay With DPDT Contacts, Undervoltage, Selectable Overvoltage, 3 x 120-240 VAC Relay control, on 3-phase networks : Overvoltage between phases, Undervoltage between phases Overvoltage between phases and neutral, Undervoltage between phases and neutral, Loss of neutral Multi-voltage Products Controls its own supply voltage True RMS measurement LED status indication 3-phase voltage controllers which monitor : Undervoltage, adjustable from -20 to -2 % of Un Overvoltage, adjustable from 2 to 20 % of Un Measurements are taken between neautral and Phases for MG73BQ MG73BQ and between Phases and Neutral for the H3USN Faults are signalled via LEDs, distinguishing the origin of the fault (one LED for the upper threshold, one LED for the lower threshold). Set the selector switch to the 3-phase network voltage Un. The position of this selector switch is only taken into account when the unit is powered up. If the switch position changes while the unit is operating, all the LEDs flash but the product continues to work normally with the voltage selected on energisation prior to the change of position. The LEDs return to their normal state if the switch is reset to its initial position defined before the last energisation. Specification GIC Controls Part Number MG73BQ (3 Phase 4 Wire/Single Phase Monitoring Relay With DPDT Contacts) Function Undervoltage/Overvoltage between phases Nominal Voltage 3 x 120 → 3 x 240 V ∿ Digital Outputs 2 x C/O Relays, 250VAC/DC @ 5 Amp Min Breaking Current 10mA/5VDC Timing Range 0.3 → 30s (0, +10%) Delay on Pickup 500ms Alarm Delay on Time (max) 200ms Reset Time 1500ms Fixed Hysteresis 2% of Un Maximum Measurement Cycle Time 150ms/True RMS Measurement Measurement Accuracy 1% Supply Voltage Range Same as Measurement 3 x 220 → 3 x 480 V ∿ Termination Style Screw Weight 170g Certification CE, UL, CSA, GL, ROHS Factory Pack Qty 1 Over Voltage Category 3 in accordance with IEC/EN 60664-1 Pollution Degree 2 in accordance with IEC/EN 61131-2 Protection rating IP40 (Front), IP20 (Rear) Mechanical Resistance Immunity to vibrations IEC/EN 60068-2-6, test Fc Immunity to shock IEC/EN 60068-2-27, test Ea Resistance to HF Interference Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12 Conducted and radiated emissions Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure) Operating Temperature -20 →+70 °C except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-22 Datasheet Product Datasheet
-
FTA-400-420-24, Hall Effect DC Current Transducer, 0-400 Amp , 4-20mA Unipolar Output, 24VDC supply, 21mm Aperture
FTA-400-420-24, Hall Effect DC Current Transducer, 0-400 Amp , 4-20mA Unipolar Output, 24VDC supply, 21mm Aperture Compact and versatile Split Core DC current sensor, 0-400 Amp , 4-20mA Unipolar Output Features ⌀21mm Aperture DC Unipolar Measurement 4-20mA Instantaneous output 120mS Response (for 0- 0-10mA ~0-10A AC) 10uS Response (0-0-400A ~0-400A AC) Panel mount Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number FTA-400-420-24 Technology DC Hall Effect Current Transducer with Instant Output Yes Supply Voltage 24VDC Nominal Current (RMS + DC) 0-400 Amp Response Time < 10uS Output Unipolar 4-20mA Instant Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Aperture 20mm Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Molex 4 Pin Unit Weight 300g Factory Pack Qty 6 Datasheet Product Datasheet
$285.00
$336.30 inclGST -
KD6 40100M2, Datalogger with Internal Web page, Universal 85-253VAC, 90-300VDC, 4 x Programmable Analogue Inputs, Modbus TCP/RTU,HTTP/NTP/FTP/RS485/USB Comms, csv File Datalogging
Free Aus Post Shipping for $300 SpendLumel KD6 40100M2, Datalogger with Internal Web page, Universal 85-253VAC, 90-300VDC, 4 x Programmable Analogue Inputs, Modbus TCP/RTU,HTTP/NTP/FTP/RS485/USB Comms, csv File Datalogging Independent logging System Internal Web page 8GB Flash Memory USB/RS485/Ethernet Comms as standard Modbus TCP/RTU,HTTP/NTP/FTP Protocols Universal 85-253VAC, 90-300VDC Supply Optional 6 x Relay outputs Optional Binary Inputs and Outputs Optional Additional 4 Analogue Inputs Specification Lumel Part Number KD6 40100M2 Functions Communication Data logger and Internal Web page Supply Voltage 90-300VDC or 85-253VAC Protocols TCP/RTU/HTTP/NTP/FTP Communication Ports RS485/USB,Ethernet RS485/RS232 Baud Rate 1200,2400,4800,9600,19200,38400,57600,115200 bit/s USB Baud Rate 115200 bit/s Ethernet Baud Rate 10,100 Mbit/s Real Time Clock 1min/month (30ppm) Isolation 3.5kV Weight 600g Factory Pack Qty 1 EU Directives EN61000, EN61010 Safety Protection Class II Enclosure Material PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP20 Operating Temperature -20 →+70 °C Datasheet Product Datasheet User Manual