Infineon TD162N16KOF, Thyristor Diode Module, 162 Amp, 1600V
Features
Thyristor for line frequency
Pressure Contact Technology
Electrically insulated base plate
Industrial standard package
Long-term stability
3600V Isolation
34mm Base Width
Applications
Power Converter
Line rectifying 50/60 Hz
Deep Cycle Applications
Controlled Rectifiers
Softstart AC motor control
AC power control
Lighting and temperature control
Specification
Infineon Part Number
TD162N16KOF
Vrrm
1600V
Diode Configuration
Thyristor Diode Module
IF(av) @ 85 Deg C
162 Amp
Package Size
W:34mm L:94mm D:30mm
Itsm
5.2 kA
VF(to)
0.85V
Tj(max)
125°C
rF
0.95mΩ
I(gt) @ 25 Deg C
150mA
Terminals
M6 Screw
Hole Centres
80mm (M6)
Gate Terminals
Spade (A 2.8 - 0.8 DIN 46244)
R th(j-c)
0.1°C/W
R th(c-h)
0.03°C/W
Weight
310g
Mounting Torque
6 Nm (6 Nm Terminals)
Factory Pack Qty
8
Certification
UL Listed, ROHS
Infineon Headquarters
Germany
Datasheet
Product Datasheet
Alternatives
See MCD162-16io1 for IXYS Solder Bonded Alternative, or MFC182-16-216F3B
Westcode-IXYS-Littlefuse MCC312-16io1, Dual Thyristor Module, 330 Amp, 1600V
Features
Thyristor for line frequency
Pressure Contact Technology
Electrically insulated base plate
Industrial standard package
Long-term stability
3600V Isolation
50mm Base Width
Applications
Power Converter
Line rectifying 50/60 Hz
Deep Cycle Applications
Controlled Rectifiers
Soft start AC motor control
AC power control
Lighting and temperature control
Specification
Westcode-IXYS-Littlefuse Part Number
MCC312-16io1
Vrrm
1600V
Diode Configuration
Dual Thyristor Module
IF(av) @ 85 Deg C
320 Amp
Package Size
W:50mm L:115mm D:52mm
Itsm
9.6 kA
VF(to)
0.8V
Tj(max)
125°C
rF
0.68mΩ
I(gt) @ 25 Deg C
150mA
Terminals
M8 Screw
Hole Centres
80mm x 48mm(M6)
Gate Terminals
Spade (A 2.8 - 0.8 DIN 46244)
R th(j-c)
0.12°C/W
R th(c-h)
0.04°C/W
Weight
680g
Mounting Torque
5 Nm (12 Nm Terminals)
Factory Pack Qty
10
Certification
UL Listed, ROHS
IXYS Headquarters
United States
Datasheet
Product Datasheet
Alternatives
TT330N16KOF
Crydom HS201DR, Panel and DIN Rail Mount Heatsink, 27 Amp @ 40 Deg C, 2°C/W
Features
DIN Rail or Panel Mount heat sink types
Suitable for SSR Mounting
Pre drilled for single or Dual SSR
Black anodised for professional look
Spec
Crydom Part Number
HS201DR
Mounting Type
Panel and Din Rail Mount
Suitable SSR Rating
40/50 Amp
Dimensions (without SSR)
L:81mm x W:45mm x D:80mm
Thermal Impedance
2°C/W
Load Current @ 40 Deg C
28 Amp
Load Current @ 50 Deg C
23 Amp
Unit Weight
437g
Factory Pack Qty
10
Datasheet
Product Datasheet
Crydom HA4850E, Solid State Relay, Single Phase 18-36VAC Control, 50A, 48-530VAC Load
Features
Ratings from 25A to 125 Amp @ 48-480VAC
SCR output for heavy industrial loads
Zero voltage or instantaneous turn-on outputs
UL/CSA/VDE Approved, CE Compliant to EN60950-1
Improved SEMS screw and washer
Redesigned housing with anti-rotation barriers
AC & DC control types
Direct bond copper substrate
EMC compliant to Level 3
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
HA4850E
Switching Type
Zero Crossing
ROHS
Yes (Details)
Control Voltage
24VAC (18-36VAC)
Load Current
50 Amp (rms)
Surge Capability
597 Amp (peak)
Special Feature
None
Mounting Style
Panel Mount
Load Voltage Range
48-530VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
75g
Factory Pack Qty
20
Datasheet
Product Datasheet
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Lumel S4AO-1200E0 RS485 Quad Analogue Output Module
4 Analogue outputs in a single module
RS485 Comms to 4-20mA
Extend Analogue Outputs on Mini PLC's
0.05% Resolution
Din Rail Mount
CE Marking
Specification
Lumel Part Number
S4AO-1200E0
Analogue Output
4-20mA
Input
RS485 Comms
Isolation
300V
Power Consumption
< 7VA
Mounting Style
Din Rail Mount
Supply Voltage Range
20...40VAC, 20...60VDC
Termination Style
Screw
Response Time
500ms (read)/1000ms (write)
Weight
200g
Factory Pack Qty
1
ROHS
Yes
CE
Yes
Datasheet
User Manual
Application Notes
Northern Design Multicube Modular Single and 3 Phase Measurement Module
Up to 20 Meters in 1 with additional modules. Requires multicube modular master unit
Minimum 2 x 3 phase or 1 x single phase circuits with measurement module
Alternative master with logger
Optional pulse output modules
Requires Multicube Modular Master or Multicube Master with Logger
Optional 12 way pulse/alarm digital output modules
Nominal current up to 0.383V (For 0.333V CT Input) and nominal voltage up to 240V L-N 415V L-L
Graphic Display
Optional RS485 or Ethernet communication up to 19,200 bit/s
True RMS measurement of currents and voltages
The meter is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, reactive power, power factor, harmonics, etc.) from the measured signals.
Features :
Dual 3 phase Measurement Module
2 x 3 Phase or 6x Single Phase Circuits
Accuracy class 1
Simple Menu
Optional MODBUS RTU RS485 communication up to 19,200 bit/s or Ethernet communication
5 Year Warranty
240V AC power supply
Specification
Northern Design Part Number
Multicube Modular Master
Functions
kWh Meter, Energy Meter, Power Quality
Supply Voltage
240VAC < 15VA
Nominal Measurement Range
415V L-L 240V L-N, 0.333V
Maximum Measurement Range
480V L-L 280V L-N, 0.383V
Display
Graphic LCD
Pulse Output
12
Accuracy
Class 1 (kW,kWh) Class 1(Active), Class 2 Reactive
Ethernet
Optional
Real Time Clock
1min/month (30ppm)
Isolation
2.11kV
RS232/RS485
N/A (Optional 2400-19200 b/s)
Weight
150g
Certification
EN 61010-1 Installation Category III
Factory Pack Qty
1
Environment
IP54
Safety
Protection Class II
Enclosure Material
ABS with fire protection to UL94-V-O. Self extinguishing
EnclosureSize
164 x 96mm x 29mm
Terminals
Rising Cage 4mm² (12 AWG) cable max
Humidity
< 75% Non Condensing
Operating Temperature
-20 →+70 °C
Datasheet
Product brochure
User manual
Wiring Diagram
Suitable 0.333V CT's
Split Core CT's
Northern Design Multicube Modular Digital Output Module
Up to 12 Pulse or Alarm outputs. Requires multicube modular master unit
Minimum 2 x 3 Phase Circuits with measurement module
Alternative master with logger
Optional pulse output modules
Requires Multicube Modular Master or Multicube Master with Logger
Optional 12 way pulse/alarm digital output modules
Nominal current up to 0.383V (For 0.333V CT Input) and nominal voltage up to 240V L-N 415V L-L
Graphic Display
Optional RS485 or Ethernet communication up to 19,200 bit/s
True RMS measurement of currents and voltages
The meter is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, reactive power, power factor, harmonics, etc.) from the measured signals.
Features :
Dual 3 phase Measurement Module
2 x 3 Phase or 6x Single Phase Circuits
Accuracy class 1
Simple Menu
Optional MODBUS RTU RS485 communication up to 19,200 bit/s or Ethernet communication
5 Year Warranty
240V AC power supply
Specification
Northern Design Part Number
Multicube Modular Master
Functions
kWh Meter, Energy Meter, Power Quality
Supply Voltage
240VAC < 15VA
Nominal Measurement Range
415V L-L 240V L-N, 0.333V
Maximum Measurement Range
480V L-L 280V L-N, 0.383V
Display
Graphic LCD
Pulse Output
12 (Optional)
Accuracy
Class 1 (kW,kWh) Class 1(Active), Class 2 Reactive
Ethernet
Optional
Real Time Clock
1min/month (30ppm)
Isolation
2.11kV
RS232/RS485
N/A (Optional 2400-19200 b/s)
Weight
150g
Certification
EN 61010-1 Installation Category III
Factory Pack Qty
1
Environment
IP54
Safety
Protection Class II
Enclosure Material
ABS with fire protection to UL94-V-O. Self extinguishing
EnclosureSize
164 x 96mm x 29mm
Terminals
Rising Cage 4mm² (12 AWG) cable max
Humidity
< 75% Non Condensing
Operating Temperature
-20 →+70 °C
Datasheet
Product brochure
User manual
Wiring Diagram
Suitable 0.333V CT's
Split Core CT's
Northern Design Multicube Modular Master Single and 3 Phase Power Meter with RS485
Up to 20 Meters in 1 with additional modules
Minimum 2 x 3 Phase Circuits with measurement module
Master Unit of Modular Multicube System
Optional 12 way pulse/alarm digital output modules
Nominal current up to 0.383V (For 0.333V CT Input) and nominal voltage up to 240V L-N 415V L-L
Graphic Display
Optional RS485 or Ethernet communication up to 19,200 bit/s
True RMS measurement of currents and voltages
The meter is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, reactive power, power factor, harmonics, etc.) from the measured signals.
Features :
20 Meters in same space as 4 traditional meters
Expandable to 20 x 3 Phase or 60 x Single Phase Circuits
Accuracy class 1
In Built Logger
Simple Menu
Optional MODBUS RTU RS485 communication up to 19,200 bit/s or Ethernet communication
5 Year Warranty
240V AC power supply
Specification
Northern Design Part Number
Multicube Modular Master with Logger
Functions
kWh Meter, Energy Meter, Power Quality, Network Recorder
Supply Voltage
240VAC < 15VA
Nominal Measurement Range
415V L-L 240V L-N, 0.333V
Maximum Measurement Range
480V L-L 280V L-N, 0.383V
Display
Graphic LCD
Pulse Output
12 (Optional)
Accuracy
Class 1 (kW,kWh) Class 1(Active), Class 2 Reactive
Ethernet
Optional
Logger
Optional
Isolation
2.11kV
RS232/RS485
Modbus RTU RS485 2400-19200 b/s
Weight
900g
Certification
EN 61010-1 Installation Category III
Factory Pack Qty
1
Environment
IP54
Safety
Protection Class II
Enclosure Material
ABS with fire protection to UL94-V-O. Self extinguishing
EnclosureSize
164 x 96mm x 100mm
Terminals
Rising Cage 4mm² (12 AWG) cable max
Humidity
< 75% Non Condensing
Operating Temperature
-20 →+70 °C
Datasheet
Product brochure
User manual
Wiring Diagram
Suitable 0.333V CT's
Split Core CT's
Northern Design Multicube Modular RS485 Comms Module
Requires Multicube Modular Master or Multicube Master with Logger
Up to 20 Meters in 1 with additional modules
Minimum 2 x 3 Phase Circuits with measurement module
Master Unit of Modular Multicube System
Optional master with logger
Optional pulse output modules
Optional 12 way pulse/alarm digital output modules
Nominal current up to 0.383V (For 0.333V CT Input) and nominal voltage up to 240V L-N 415V L-L
Graphic Display
Modbus RS485 up to 19,200 bit/s
True RMS measurement of currents and voltages
The meter is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, reactive power, power factor, harmonics, etc.) from the measured signals.
Features :
20 Meters in same space as 4 traditional meters
20 x 3 Phase or 60 x Single Phase Circuits
Accuracy class 1
Simple Menu
MODBUS RTU RS485 communication up to 19,200 bit/s
5 Year Warranty
240V AC power supply
Specification
Northern Design Part Number
Multicube Modular RS485 Comms Module
Functions
kWh Meter, Energy Meter, Power Quality
Supply Voltage
240VAC < 15VA
Nominal Measurement Range
415V L-L 240V L-N, 0.333V
Maximum Measurement Range
480V L-L 280V L-N, 0.383V
Display
Graphic LCD
Pulse Output
12 (Optional)
Accuracy
Class 1 (kW,kWh) Class 1(Active), Class 2 Reactive
Ethernet
Optional
Real Time Clock
1min/month (30ppm)
Isolation
2.11kV
RS232/RS485
2400-19200 b/s
Weight
175g
Certification
EN 61010-1 Installation Category III
Factory Pack Qty
1
Environment
IP54
Safety
Protection Class II
Enclosure Material
ABS with fire protection to UL94-V-O. Self extinguishing
EnclosureSize
164 x 96mm x 29mm
Terminals
Rising Cage 4mm² (12 AWG) cable max
Humidity
< 75% Non Condensing
Operating Temperature
-20 →+70 °C
Datasheet
Product brochure
User manual
Wiring Diagram
Suitable 0.333V CT's
Split Core CT's
Northern Design Multicube Modular TCP/IP Comms Module NEW WEB PAGE VERSION, with Internal logger
Requires Multicube Modular Master or Multicube Master with Logger
Up to 20 Meters in 1 with additional modules
Minimum 2 x 3 Phase Circuits with measurement module
Master Unit of Modular Multicube System
Optional master with logger
Optional 12 way pulse/alarm digital output modules
Nominal current up to 0.383V (For 0.333V CT Input) and nominal voltage up to 240V L-N 415V L-L
Graphic Display
Modbus RTU Ethernet communication up to 19,200 bit/s
True RMS measurement of currents and voltages
The meter is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, reactive power, power factor, harmonics, etc.) from the measured signals. NEW WEB PAGE VERSION
Features :
NEW WEB PAGE VERSION
20 Meters in same space as 4 traditional meters
20 x 3 Phase or 60 x Single Phase Circuits
Accuracy class 1
Simple Menu
MODBUS RTU RS485 communication up to 19,200 bit/s
5 Year Warranty
240V AC power supply
Specification
Northern Design Part Number
Multicube Modular Master
Functions
kWh Meter, Energy Meter, Power Quality
Supply Voltage
240VAC < 15VA
Nominal Measurement Range
415V L-L 240V L-N, 0.333V
Maximum Measurement Range
480V L-L 280V L-N, 0.383V
Display
Graphic LCD
Pulse Output
12 (Optional)
Accuracy
Class 1 (kW,kWh) Class 1(Active), Class 2 Reactive
Ethernet
2400-19200 b/s
Real Time Clock
1min/month (30ppm)
Isolation
2.11kV
RS232/RS485
Optional
Weight
175g
Certification
EN 61010-1 Installation Category III
Factory Pack Qty
1
Environment
IP54
Safety
Protection Class II
Enclosure Material
ABS with fire protection to UL94-V-O. Self extinguishing
EnclosureSize
164 x 96mm x 29mm
Terminals
Rising Cage 4mm² (12 AWG) cable max
Humidity
< 75% Non Condensing
Operating Temperature
-20 →+70 °C
Datasheet
Product brochure
User manual
Wiring Diagram
Suitable 0.333V CT's
Split Core CT's