Search results for "multimeter"
-
FESCTHY-3000-1250-100mV, 1250Amp 100mV Class 1 Measurement Split Core CT's, 1M Flying Leads, HY2.0 Connection, 76x127mm Aperture
Fastron Electronics FESCTHY-3000-1250, 1250Amp 100mV Class 1 Measurement Split Core CT's, 1M Flying Leads, 76x127mm Aperture Features Quick Release Split Core System 1m Flying Leads Mounting Feet Supplied Self Powered Rated System Voltage 0.60/3kV Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Β Specification Fastron Electronics Part Number FESCTHY-3000-1250 Technology Split Core AC Current Transformer Ratio 1200/100mV Aperture Size 76x127mm VA Rating N/A Accuracy Class Class 1 Output 100mVAC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15Β°C / 55Β°C Continuous Current (max) 1250Amp x 1.2 Termination Style Terminals Unit Weight 3000g Factory Pack Qty 9 Β Datasheet Product Datasheet Installation Guide FESCTHY InstallΒ Guide
$208.00
$245.44 inclGST -
F921 AC Series Current Transducer, 100mA to 400 Amp Range with Adjustable High and Low C/O Relay Alarm
F921 Series AC Current Transducer with Process Outputs & High and Low C/O Alarm Features Isolated measurement of AC currents using internal Hall effect transducer. Incorporates an integrated input level display and power supply. Wide measurement range available Choice of standard outputs Wide range isolated DC input supply DIN Rail mounting Signal Conditioned AC measurement output On board bar graph display User adjustable zero offset and span controls Zero insertion loss in current measurement path Earth leakage via differential Ipn for nominal Input β01β Applications Process control Transportation Petrochemical Industrial Earth Leakage Energy Monitoring/Measurement Automation Delivery Delivery in 3-5 days for small qty. Otherwise 4-6 weeks Specification Oztherm Part Number F921-X-XX-AC-XX Functions Single Phase AC Current Transducer Supply Voltage 9-36VDC Nominal Measurement Range 0-400 Amp (Sensor dependant) Maximum Measurement Range 0-2500 Amp (with HAX 2500-S external Sensor) Alarm C/O Relay 4Amp @ 30VDC, 0.5Amp @ 150VAC Response Time 250mS Accuracy @ 25 Deg C Class 1 Bandwidth DC - 1kHz linearity < 0.15% Isolation 2.5kV Comms N/A Weight 250g Enclosure Size 79 x 60 x 85mm Factory Pack Qty 1 EU Directives N/A Safety Protection Class II 600V rms, installation category II 300V rms, installation category III Pollution Degree 2 in compliance with SIST EN 61010-1:2002 Enclosure Material Polyamide non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP40 Shock Withstand 300g 8ms Pulse . 6 Shocks in each of 3 axes Vibration Withstand 0.7g, 3...100Hz, 1oct/min 10 cycles in each of three axes Operating Temperature -20 β+70 Β°C Datasheet Product Datasheet
$595.00
$702.10 inclGST -
F923 DC Series Current Transducer with Adjustable High and Low C/O Relay Alarm
F923 Series DC Current Transducer with Process Outputs & High and Low C/O Alarm Features Isolated measurement of DC currents using internal Hall effect transducer. Incorporates an integrated input level display and power supply. Wide measurement range available Choice of standard outputs Wide range isolated DC input supply DIN Rail mounting Signal Conditioned DC measurement output On board bar graph display User adjustable zero offset and span controls Zero insertion loss in current measurement path Earth leakage via differential Ipn for nominal Input β01β Applications Process control Transportation Petrochemical Industrial Earth Leakage Energy Monitoring/Measurement Automation Delivery Delivery in 3-5 days for small qty. Otherwise 4-6 weeks Specification Oztherm Part Number F923-X-XX-DC-XX Functions Single Phase AC Current Transducer Supply Voltage 9-36VDC Nominal Measurement Range 0-8 Amp (Sensor dependant) Maximum Measurement Range 8 Amp Alarm C/O Relay 4Amp @ 30VDC, 0.5Amp @ 150VAC Response Time 250mS Accuracy @ 25 Deg C Class 1 Bandwidth DC - 1kHz linearity < 0.15% Isolation 2.5kV Comms N/A Weight 250g Enclosure Size 79 x 60 x 85mm Factory Pack Qty 1 EU Directives N/A Safety Protection Class II 600V rms, installation category II 300V rms, installation category III Pollution Degree 2 in compliance with SIST EN 61010-1:2002 Enclosure Material Polyamide non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP40 Shock Withstand 300g 8ms Pulse . 6 Shocks in each of 3 axes Vibration Withstand 0.7g, 3...100Hz, 1oct/min 10 cycles in each of three axes Operating Temperature -20 β+70 Β°C Datasheet Product Datasheet
$552.00 - $595.00
-
SCT-F36-600-5A, 5 Amp, 600Amp Measurement, Class 1 Split Core CT's
Fastron Electronics SCT-F36-600-5A, 5 Amp, 600Amp measurement Split Core CT's Features Quick Release Split Core System Cable Mount 5 Amp Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number SCT-F36-600-5A Technology Split Core AC Current Transformer Ratio 600/5 Amp Aperture Size ΓΈ 35 mm VA Rating N/A Accuracy Class Class 1 Output 5 Amp (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15Β°C / 45Β°C Continuous Current (max) 600Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 400g Factory Pack Qty 9 Datasheet Product Datasheet Stocked Split Core CT's Listing Application Notes Installation Guide Types of Current Transformers - Blog Cable Losses and CT's High Accuracy or High Burden Requirements for CT's
$66.50
$78.47 inclGST -
SCT-F36-300-5A, 5 Amp, 300Amp Measurement, Class 1 Split Core CT's
Fastron Electronics SCT-F36-300-5A, 5 Amp, 300Amp measurement Split Core CT's Features Quick Release Split Core System Cable Mount 5 Amp Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number SCT-F36-300-5A Technology Split Core AC Current Transformer Ratio 300/5 Amp Aperture Size ΓΈ 35 mm VA Rating N/A Accuracy Class Class 1 Output 5 Amp (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15Β°C / 45Β°C Continuous Current (max) 300Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 400g Factory Pack Qty 9 Datasheet Product Datasheet Stocked Split Core CT's Listing Application Notes Installation Guide Types of Current Transformers - Blog Cable Losses and CT's High Accuracy or High Burden Requirements for CT's
$66.50
$78.47 inclGST -
AM5S-C-N2-D-N, 48x24mm Digital Totaliser 7kHz, NPN 12VDC, 22-60VAC/DC supply
Free Aus Post Shipping for $300 SpendFastron Electronics AM5S-C-N2-D-N, 48x24mm Digital Totaliser 7kHz, NPN 12VDC, 22-60VAC/DC supply Large 5 Digit 0.4 Inch LED Display 250mS Response Time PC 94 UL V0 Input signals can be NPN, PNP, or 24VDC Pulses depending on the model used Each unit needs just 48 x 24mm Panel Space 86.2mm Depth Specification Fastron Electronics Part Number AM5S-C-N2-D-N Input NPN 12VDC Measurement Range 0 - 7kHz Operating Temperature 0 - 60Β°C Load Voltage 22-60VAC/DC Termination Style Screw Mounting Style 48 x 24mm Panel Mount Case Material PC - UL 94 V0 Safety Approvals CE Weight 320g Factory Pack Qty 1 Β Datasheet Product Datasheet Application Notes Panel Meters Blog Articles
Free Aus Post Shipping for $300 Spend$129.00
$152.22 inclGST -
SCT-F24-150-40mA(SCT-F24-150-040A), 40mA, 150Amp Measurement, Class 1 Split Core CT's
Fastron Electronics SCT-F24-150-040A, 40mA, 150Amp measurement Split Core CT's, Class 1 Series Current Transformer Features Quick Release Split Core System Cable Mount 40mA Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Β Specification Fastron Part Number SCT-F24-150-40mA(SCT-F24-150-040A) Technology Split Core AC Current Transformer Ratio 150/40mA Aperture Size ΓΈ 24 mm VA Rating N/A Accuracy Class Class 1 Output 40mAmp (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15Β°C / 45Β°C Continuous Current (max) 150Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 100g Factory Pack Qty 9 Β Datasheet Product Datasheet Application Notes Installation Guide
$50.50
$59.59 inclGST -
RCS-1200-800 0.333V, 3 Phase 800Amp AC Measurement 4 Inch β Rogowski Coils with Integrator, Class 1
RCS-1200-800 0.333V, 3 Phase 800Amp AC Measurement 4 Inch β Rogowski Coils with Integrator, Class 1 Flexible Current Sensor System: The RCS-1200 three-phase flexible rope CT from Magnelab converts AC input current of up to 5000 amperes to an AC output of 0.333 volt. A 9 to 36 VDC power supply is required to operate these coils. The RCS-1200 comes with an integrator which includes flexible strain relief cables. Included is an 12 inch circumference rope CT with Integrator, and 8 feet of twisted pair (600V) output leads. Magnelab Coils come with 10 year warranty Suitable Alternative to Solar Edge CTRC-07500-1000 Β Specification Magnelab Part Number RCS-1200-800 Function AC Current Measurement Nominal Measurement Current 800 Amp RMS Measurement Range 10% - 130% if Ipn Frequency Measuring Range 50-1500Hz (15th Harmonic) Operating Voltage 9 - 36VDC Accuracy 1% from 25 to 1000 Amp Phase Angle < 0.5 Degrees Coil Diameter (β) 4 Inch Coil Circumference 12 Inch Integrator to Coil Cable 8 Feet Shielded Maximum Voltage 600V (on bare conductor) Operating Temperature -15Β°C to 65Β°C Storage Temperature -45Β°C to 80Β°C Power Consumption < 2VA Overload 20,000 Amp (continuous) Termination Style Screw Weight 1200g Certification CE Factory Pack Qty 1 Certifications UL Recognized E96927 to IEEE C57.13, CAN/CSA 60044-1 Meets UL STD 61010-1, CAN/CSA C22.2 No. 61010 CE ROHS Datasheet Product Datasheet Application Notes RCS/RCT Series Installation Guide
$790.00
$932.20 inclGST -
SCT-F36-400-40mA, 40mA, 400Amp Measurement, Class 1 Split Core CT's
Fastron Electronics SCT-F36-400-40mA, 40mA, 400Amp Measurement, Class 1 Split Core CT's Features Quick Release Split Core System Cable Mount 40mA Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Β Specification Fastron Part Number SCT-F36-400-40mA Technology Split Core AC Current Transformer Ratio 400/040 Amp Aperture Size ΓΈ 35 mm VA Rating N/A Accuracy Class Class 1 Output .40 Amp (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15Β°C / 45Β°C Continuous Current (max) 400Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 400g Factory Pack Qty 9 Β Datasheet Product Datasheet Stocked Split Core CT's Listing Application Notes Installation Guide Types of Current Transformers - Blog Cable Losses and CT's High Accuracy or High Burden Requirements for CT's
$66.50
$78.47 inclGST -
LC32F1 4-36VAC/DC, Hours Run Meter 90-264VAC, 37x24mm Panel Mount, with two Mounting Holes Bezel
GIC Controls, LC32F1 4-36VAC/DC, Hours Run Meter 90-264VAC, 37x24mm Panel Mount, with two Mounting Holes Bezel Β Features IP40 (IP66 with Gasket) 4-36VAC/DC 6 Digit Display 99999.9 Hours 37x24mm Panel Mount Two Mounting Hole Bezel RectangularΒ Cutout UL Approved Datasheet Product Datasheet
$35.00
$41.30 inclGST -
FP010080P/40mA, 100/40mA Split Core CT, Class 1, Series Clip On Current Transformer
FP010080P/40mA, 100/40mAΒ Split Core CT, Class 1,Β Series Clip On Current Transformer Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Β Specification Fastron Part Number FP010080P/40mA Technology Split Core AC Clip On Current Transformer Ratio 100/40mA Aperture Size 50 x 80mm VA Rating 1.5VA Accuracy Class Class 1 Output 40mAΒ Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -10Β°C / 50Β°C Continuous Current (max) 100Amp x 1.2 Termination Style Screw Approvals CE Unit Weight 1150g Factory Pack Qty 1 Β Datasheet Product Datasheet Installation Guide Β
$112.00
$132.16 inclGST -
TRT-22D-Y-400, 22mm LED NTC Thermometer AMBER 0-100β 200-400VAC, Plastic, IP40, IEC60947-5-1
TRT-22D-Y-400, 22mm LED NTC Thermometer AMBER 0-100β 200-400VAC, Plastic, IP40, IEC60947-5-1 LED indicator Series will activate while the contacts are connected to the rated voltage. Widely Used for Rugged Industrial Applications Including Critical Machinery requiring safe operation and visual Indication by the user. Features : 200-400VAC Supply 0-100β Measurement NTC Input LED Illumination Γ 22.5mm Cutout Long Life LED Replacement Beads Available RED, GREEN, AMBER, BLUE, or Clear\White Colour Standards : IP40 IEC60947-5-1 CE Specification TRENT Part Number TRT-22D-Y-400 Functions LED Frequency Meter Measurement Range 0-0-100β Nominal Voltage 400VAC @ 50/60Hz Impulse Voltage Wear Resistance 6kV Illumination Type Amber LED Short Circuit Protection (Fuse) Recommend 10A gG Fuse Mechanical Compression Force at Closing 20N Mechanical Compression Force at Closing 8N Humidity 35-85% Approvals CE Standards IP65, IEC60947-5-1 Weight Enclosure Material UL94V0 Factory Pack Qty 1 TRENT(Fastron) Head Office Australia Β Datasheet Product Datasheet
$25.00
$29.50 inclGST