Northern Design Rail310-M2 Series 3 x Single Phase Multifunction Meter
5 Amp CT Input
Optional RS 232/RS 485 communication up to 19,200 bit/s
RMS values of currents and voltages
Measurements of active, reactive power, power factor, average current and voltage
The meter is intended for measuring, and monitoring single-phase or electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc to the 30th Harmonic) from the measured signals.
Features :
Accuracy class 1
Measurement of Active and Reactive Power
RS 232/RS 485 communication up to 19,200 bit/scommunication
Optional MODBUS communication protocol
Graphic LCD with illumination
Multilingual support
User-friendly PC MiQen software
Specification
Northern Design Part Number
Rail310-M2
Functions
3 x Single Phase Energy Meter
Supply Voltage
230V L-N, 5 Amp +/-15% < 5VA
Nominal Measurement Range
3 x 230V L-N, 5 Amp +/-15%
Maximum Measurement Range
3 x 230V L-N, 5 Amp +/-15%
Nominal Current Input
5 Amp AC
Pulse Output
3 x NO Voltage Free Contacts 100mA @ 70VDC/33VAC
Tariff Input
N/A (Optional)
Accuracy
Class 1 (I,U,F,PF,) Class 2 (Reactive)
Mounting
Din Rail
Real Time Clock
1min/month (30ppm)
Internal Memory
N/A
Dimensions
106mm x 90mm x 58mm (6 modules wide)
Isolation
3.5kV
RS232/RS485
1200-19200 b/s (Optional)
Weight
325g
Certification
EN 61010-1 Installation Category III
Factory Pack Qty
1
Enclosure Material
Noryl with fire protection to UL94-V-O. Self extinguishing
Northern Design Head Office
United Kingdom
Operating Temperature
-20 →+70 °C
Datasheet
Product Datasheet
Product Manual
Fastron Electronics BTCD/A-M-A2-DA, PID Controller 96x96mm, 85-265VAC, 4-20mA output 2 Alarms, 4-20mA Cooling, Multirange TC/RTD/4-20mA Input
4-digit displays suit most industries including Temperature, Humidity, Pressure (0.5s response)
Drip-proof / Dust-proof IP56 (front panel only)
CE Approved
Each unit needs just 80 mm depth panel space
Optional Pattern Control Feature
Specification
Fastron Part Number
BTCD/A-M-A2-DA
Control Output
4-20mA
Input
Multirange 4-20mA/RTD/Thermocouple (other linear inputs to be specified at time of order)
Option 1
2nd Alarm
Option 2
4-20mA Cooling
Mounting Style
96 x 96mm Panel Mount
Load Voltage Range
100-240VAC
Termination Style
Screw
Weight
600g
Factory Pack Qty
1
CE
Yes
Datasheet
BTC Series Brochure
BTC Series User Manual
BTC Series RS485 Comms Manual
Fine Tuning PID Adjustments
Shinko RAU-O Series Signal Conditioners
Universal Input (Thermocouple, RTD, DC Current, DC Voltage, Potentiometer) Signal Conditioner 100-240 VAC, 4-20mA output
4-digit display. Suit most industries including Temperature, Humidity, Pressure (0.25s response)
Tropicalised Version Available
UL/CSA Approved
Input signals can be converted to insulated 4 to 20 mA DC output (0.25s Response)
Each unit needs just 22.5mm width Din Rail space
EC Compliant (Details)
Specification
Shinko Part Number
RAU-O
Control Output
4-20mA Output
Input
Universal (TC, RTD, DC Amp, DC Volt, POT)
Special Function
3 Port Isolation for noisy environments
Option
RS485 Comms
Mounting Style
22.5 x 75mm Din Rail Mount
Supply Voltage
100 - 240VAC
Termination Style
Screw
Weight
230g
Factory Pack Qty
1
ROHS
Yes
UL
Yes
CE
Yes
Datasheet
RA Series Brochure
RA Series User Manual
Delivery 2-3 weeks delivery if not in stock
Crydom D2440D, Dual Solid State Relay, Two Pole 4-15VDC Control, 2 x 40A, 24-280VAC Load
Features
Ratings from 2 x 25A to 2 x 40 Amp @ 24-530 VAC
SCR output for heavy industrial loads
Zero voltage or instantaneous turn-on outputs
UL/CSA/VDE Approved, CE Compliant to EN60950-1
Improved SEMS screw and washer
Redesigned housing with anti-rotation barriers
AC & DC control types
Direct bond copper substrate
EMC compliant to Level 3
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
D2440D
Switching Type
Zero Crossing (Dual)
ROHS
Yes (Details)
Control Voltage
4-15VDC
Load Current
2 x 40 Amp (rms)
Surge Capability
597 Amp (peak)
Special Feature
Dual SSR
Mounting Style
Panel Mount
Load Voltage Range
24-280VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
75g
Factory Pack Qty
20
Datasheet
Product Datasheet
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
VFD13AMS43ANSAA, 3 Phase Variable Frequency Drive, 460VAC, 13 Amp (Normal Duty)/15.7 Amp (Heavy Duty), 460VAC L-L, 0.1-599 Hz, 207x109x187mm
Features
3 Phase VFD/VSD
4-20mA, 0-5V, 0-10V Proportional Input Control
7 x Digital Input
2 x STO Inputs
Fully enclosed IP20 (Optional IP40)
Small frame Size
Applications
Fan Motor Control
Production Lines
Transportation
Controlled Power Applications
Suitable for extreme environments such as mining
Specification
Delta Part Number
VFD13AMS43ANSAA
Rated Operation Temperature
50°C (With Derating)
Configuration
3 Phase AC Drive
Control Voltage
4-20mA, 0-20mA, 0-10V
Digital Inputs
7 x Mix / 2 x STO
Load Current
13 Amp(Normal Duty) / 15.7 Amp(Heavy Duty) Per Phase
Control Range
0.1-599 Hz
Dimensions
207x109x187mm
Mounting Style
Panel Mount
Supply Voltage Range
323-528VAC
Soft Start
0-6000s
Termination Style
Screw
Unit Weight
2.5kg
Factory Pack Qty
1
Datasheet
MS300 Brochure
User Manual
RTR Energia REG12DPR1400000 PR-14D.12 8/10/12 Step Automatic Reactive Power Controller, 3 Phase
Isolated Switching of Power Factor Correction Contactors
Cos ϕ Setting 0.80 to 0.95 CAP
Single CT Sensing
1A/5A Programmable Primary and secondary CT Ratio
Backlit LCD Display
Various Program Combinations
IP40
Up to 12 steps
Measurement System - Automatic/Manual
230VAC Aux Supply
Overvoltage and Under/Overcompensation management
Overtemperature alarm
Specification
RTR Energia Part Number
PR-14D.12
Function
Reactive Power Correction
Nominal Voltage (Un)
90-550V L to L, 11-300V L-N
Supply Voltage
90-550V L to L, 15VA (max) 45-65Hz
Relay Rating
250VAC/6Amp NO
Switch Delay Time
1s - 999s User Adjustable
Fan Alarm
1 x 250VAC/6Amp NO
Temperature Alarm
1 x 250VAC/6Amp NO
Re-connection Delay Time
1s - 999s User Adjustable
Desired Power Factor
0.85 IND - 0.95 CAP
Number of Output Relays
14 (12 steps, fan and temperature alarm)
Smallest Capacitor Current
50mA
CT Input Range
0.05 - 5.5 Amp
LCD Display Accuracy
Voltage +/-0.5%, Frequency +/-0.1%, Power +/-1% Energy Class 1
Phase Angle Error
+/- 1% at I > 3% of range
Comms
RS485 Target PFC (Optional)
Termination Style
Screw
Weight
700g
Certification
IEC 654-1
Factory Pack Qty
1
Material of housing
PC/ABS Unflammable, according to UL 94 V-0
Enclosure protection
IP40 for case, IP20 for terminals
Safety
According to EN 61 010-1, installation category III Pollution degree 2
Operating Temperature
0...60 °C
Datasheet
Product Datasheet/User Manual
Application Notes
Discharge Resistor Usage
Power Factor Correction Blog
Risbabh EM94-Z-V1-H-Z, Panel Mount DC kWh Meter, Class 0.5, 50-150mV Shunt input, 60-300VDC, Single Line LCD Display, 60-300VAC/DC Aux Supply, Internal Logging
2 Pulse/Alarm Outputs
50-150mV Shunt Input, and nominal voltage 60-300VDC
RS 485 communication up to 57,600 bit/s
USB Port
8MB Internal Storage
DC Measurement Only
The meter is intended for measuring, analysing and monitoring DC Power. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current,, energy, power.) from the measured signals.
Features :
96 x 96mm Panel Mount
Accuracy class 0.5
Simple Menu
RS 485 communication up to 57,600 bit/s
USB Comms
8MB Internal Logger
60-300VAC/DC power supply
Specification
Rishabh Part Number
EM94-Z-V1-H-Z
Functions
kWh Meter, Energy Meter
Supply Voltage
60-300VAC/DC
Nominal Measurement Range
60-300VDC
Maximum Measurement Range
60-300VDC
Display
Single Line LCD
Pulse/Relay Output
2
Accuracy
Class 0.5 (Energy)
USB
YES
Real Time Clock
1min/month (30ppm)
Isolation
3.5kV
RS485 Modbus RTU
YES 57,600bps
Weight
450g
Certification
EN 61010-1 Installation Category III
Factory Pack Qty
1
Environment
IP54
Safety
Protection Class II
Enclosure Material
Mablex with fire protection to UL94-V-O. Self extinguishing
EnclosureSize
96 x 96mm x 83.5mm (72mm behind panel)
Terminals
Rising Cage 4mm² (12 AWG) cable max
Humidity
< 75% Non Condensing
Operating Temperature
-20 →+70 °C
Datasheet
Product Datasheet
Software
Software User Manual
Software Download Link
Application Notes
1)Reading Data from Registers -> Download file
2)Maximum Memory Size -> Read below
Max Available Memory Locations in 8MB Size = 273030
Actual parameter stored in Each log (Memory locations used) = Date +time+Number of parameter selected by user
Considering your example for 2 parameters:
Number of parameter selected by user = 2 (kwh & kVA)
Actual parameter stored in Each log = 1(Date) +1(time)+ 2 (Parameters) = 4 (memory locations used per log)
Maximum log that can be stored = Max Memory Location/Actual parameter stored in Each log =273030/4= 68257
Timelog Interval setting = 15 minutes
Log in one day = (60 /Timelog Interval setting) * 24 =(60/15)*24 = 96 Logs
Max Days = Maximum log that can be stored / log in one day = 68257 / 96 = 711 days = 1 Year & 11 Months = 23 Months.
Iskra IKD225-20-R-230VAC, Two Pole 2 x NO Modular Contactor 240VAC 25 Amp, 230VAC 40-500Hz Control Voltage, Hum Free with Manual Overide
Features
25 Amp (rms) @ 240VAC
DIN Rail Mount
Changeover Contact
Slim package
CE Compliant to IEC 60664
IP20
Specification
Fastron Part Number
IKD225-20-R-230VAC 40-500Hz
Switching Type
2 x SPST NO
Approvals
CE
Coil Voltage
230/240VAC/220VDC 40-500Hz
Load Rating
25 Amp
Special Feature
Hum Free, Manual Override
Mounting Style
DIN Rail Mount
Load Voltage Range
230/240VAC 40-500Hz
Isolation
4kV
Termination Style
Screw
Unit Weight
295g
Factory Pack Qty
20
Datasheet
Contactor Datasheet
VX2-USNA-A2, Temp Controller, 48x96mm, 100-240VAC, Multirange Input, SSR Output, 2 Alarms
Multirange Input (Programmable)
4-digit displays suit most industries including Temperature, Humidity, Pressure (0.5s response)
Drip-proof / Dust-proof IP65 (front panel only)
UL/CE Approved
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 60 mm depth panel space
EC Compliant
Specification
Hanyoung Nux Part Number
VX2-USNA-A2
Control Output 1 (Heat)
SSR 12-15VDC @30mA
Control Output 2 (Cool)
N/A
Input
Multirange Type K/J/E/T/R/B/S/L/N/U/W/PLII/PT100/JPT100/4-20mA/0-20mA/1-5V/0-5V/0-10V/0-50mV/0-100mV. Note for Direct Current Input please use 250 Ohm Resistor in Parallel to the input terminals.
Alarm
Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)
Option 1
2nd Alarm Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)
Option 2
N/A
Mounting Style
48 x 96mm Panel Mount
Supply Voltage
85 - 265VAC
Termination Style
Screw
Weight
350g
Factory Pack Qty
1
ROHS
Yes
UL
Yes
CE
Yes
Datasheet
VX Series Brochure
VX Series Instruction Manual
Free Software
Hanyoung Nux TCS Software
Hanyoung Nux TCS Software User Manual
VX Series SB Driver (Windows 7) Not required for Windows 10 or 11
Advanced Energy Thyro-A-3A-400-30-H-RL3, Three Phase SCR Controller 30 Amp 400VAC +10/-57%, Phase(VAR), Burst(TAKT) Fire, SWITCH Operating Modes, Voltage Control, Current Feedback Option
Features
400VAC +10/-57% Line to Line Voltage, Current or Power Control
Smallest footprint on the market
Built in Fuses
3 Phase, Phase Angle & Burst Controller with SWITCH operation mode
SWITCH between Phase(VAR) or Burst(TAKT) control modes
(0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control
Removable Cover
USB Configuration/Bias Setting
Potentiometer Adjustments
Synchronisation Function for Multiple TAKT Sync
Applications
Electrical Ovens, Kilns, or Furnaces
Primary Control of Transformer Loads in Phase or Burst Fire mode
Resistive Loads up to 6:1 Hot/Cold Ratio
AC Soft Starter (VAR Mode Combined with PLC)
Power Regulation Applications
Electric Boilers
Brewery Heating
Industrial Light Dimming
Suitable for extreme environments such as mining
Series Optional Features
For HRL
Current Control/Feedback
Programmable Relay Alarm Output
Load Monitoring
Analogue Output
For HRLP
As above with Power Control Feedback
Communication Options
Standard Thyro Bus Module
BasicBus Module
Specification
Advanced Energy Part Number
Thyro-A-3A-400-30-H-RL3
Approvals
CE, UL508A, EU Directive 2014/35/EU & 2004/108/EC
Control Accuracy
3% at rated voltage
Rated Operating Temperature
45°C
Temperature Derating
0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C
SCR Configuration
Three Phase AC Switch
Control Modes
Phase(VAR), Burst(TAKT), QUick TAKT(QTM), Hybrid(VT on request)
Control Input
4(0)-20mA, 0(1)-5V, 0(2)-10V, POT
Load Current
16 to 1500 Amp @ 45 Deg C (110% @ 35 Deg C Max)
Control Range
0-100%
Options
Conformal Coating for Gas or High Humidity Environments
Mounting Style
Panel Mount
Supply Voltage Range
400VAC +10/-57% (-57% with 24VDC Aux Supply)
Soft Start
Via PLC input
Termination Style
Screw
Unit Weight
2.1 to 74kg
Factory Pack Qty
1
Technical Docs
Brochure
User Manual
2 Leg Control Application Blog
Thyro A Series Quick Installation Guide
Setting Up Comms on Thyro A Series Controllers
Anybus Device Ethernet IP Setup Guide
Crydom HS211 + D5D10, Din Rail Mount DC Solid State Relay, with Heatsink 3-32VDC control, 7.5A @ 40 Deg C, 500VDC Load
Features
Ratings from 7 to 100 Amp @1-500VDC
SCR output
Zero voltage or instantaneous turn-on outputs
UL/CE/ROHS Compliant
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Panel Mount
Din Rail Mount
Spec
Part Number
HS211 + D5D10
Switching Type
DC Switching
ROHS/CE/UL
Yes
Control Voltage
3.5-32VDC
Load Current
7.5 Amp (rms) @ 40 Deg C
Surge Capability
29 Amp (peak)
Special Feature
N/A
Mounting Style
Din Rail or Panel Mount
Recommended Voltage Range
1-385VDC
Max DC Voltage
500V
Termination Style
Screw Terminals
Dimensions
L:81mm x W:45mm x D:73.4mm
Unit Weight
296g
Factory Pack Qty
20
Datasheet
HS211
Series 1 DC
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Infineon D798N12T Rectifier Diode Capsule
Features
Very low forward voltage drop
Very low leakage current
International standard package
48/14 Package
Press Mounted
Double or Single Sided Cooling
Applications
Power Supplies
Rectifier for drives applications
Uncontrolled Rectifiers
Rectifiers for UPS
Battery Chargers
Field Supply for DC Motors
Water Cooled Rectifiers
DC Substation Blocking Diode
Large Generators
Specification
Infineon Part Number
D798N12T
Vrrm
1200V
Diode Configuration
Diode Capsule (PUK)
IF(av) @ 85 Deg C
800 Amp
Package Size
ø48 x 14mm
Itsm
14.8 kA
VF(to)
0.81V
Tj(max)
180°C
rF
0.51mΩ
Gate Terminals
N/A
R th(j-c) (double sided cooled 180°sin)
0.046°C/W
R th(c-h) (double sided cooled)
0.0075°C/W
Weight
110g
Clamping Force
6 - 15kN
Factory Pack Qty
12
Certification
ROHS
Infineon Headquarters
Germany
Datasheet
Product Datasheet
Alternatives
D820N20T
D798N16T
Heatsink