Rishabh CT 300/5 Class 0.5 5VA 50/30 (30) 300/5 Amp Current Transformer 5VA, Class 0.5
Features
DIN Rail Mounting Clip Included
Built In Sealable Terminal Covers
Mounting Feet Supplied
Narrow Width (45mm)
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Rishabh Part Number
CT 300/5 Class 0.5 5VA 50/30 (30)
Technology
AC Current Transformer
Ratio
300/5
Aperture Size
⌀ 26mm or 30x10mm Busbar
VA Rating
5VA
Accuracy Class
Class 0.5
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Din Rail Mount
Operating Temperature Range
-30°C / 85°C
Continuous Current (max)
300Amp x 1.2
Termination Style
Screw
Unit Weight
300g
Factory Pack Qty
9
Datasheet
Product Datasheet
Iskra Doo MC330 S 110V SUNNNP, Panel Mount Mutifunction Meter, Class 1, 110VAC 50/60Hz Measurement, Universal 20-300VDC, 48-265VAC Aux, Internal Logger
Internal 8MB Logger
Automatic range of nominal current up to 12.5 A (Includes 5A/1A CT Input) and nominal voltage up to 500 V L-N
Adjustable tariff clock, display of electric energy consumption in optional currency
Optional RS 232/RS 485 communication up to 115,200 bit/s
RMS values of currents and voltages
Measurements of active, reactive, apparent power and power factor
Measurements of energy in all 4 quadrants Average values of measurands per interval
The meter is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals.
Features :
Internal Logger
Measurement of instantaneous values of more than 60 quantities (U, I, P, Q, S, PF, PA, f, f, MD, etc.). Includes Harmonics
Accuracy class 0.5
Measurement of 20 minimal and maximal values in different time periods
Optional dual tariff inputs and pulse or relay outputs
Wide frequency range from 16 Hz to 400 Hz
RS 232/RS 485 communication up to 115,200 bit/s or Ethernet communication
MODBUS communication protocol
Up to 4 inputs or outputs (pulse outputs, alarm outputs, tariff inputs)
Universal or AC power supply
Graphic LCD 128 x 64 dots with illumination
Automatic range of nominal current up to 5 A and nominal voltage up to 600 V
Multilingual support
User-friendly PC MiQen software
Specification
Iskra Doo Part Number
MC330 S 110V SUNNNP
Functions
Power Quality Meter, Energy Meter
Supply Voltage
Universal 20-300VDC, 48-276VAC
Nominal Measurement Range
110VAC L-N, 5 Amp
Maximum Measurement Range
132V L-N, 12.5 Amp
Alarm
Optional 2 x Relay Output
Tariff Input
Optional 2 x
Analogue Output
Optional 2 x
Accuracy
Class 1 (I,U,F,PF,θ,THD) Class 1(Active), Class 2 (Reactive)
Battery Backup
N/A
Real Time Clock
1min/month (30ppm)
Isolation
3.5kV
Internal Logger
Yes (8MB)
RS232/RS485
N/A Optional
CT Terminations
Through Hole CT
Weight
500g
Certification
UL, CSA, ROHS
Factory Pack Qty
1
EU Directives
Degree on electrical equipment designed for use within certain voltage limits URLRS 53/00 (Directive 73/23/EEC on low voltage): SIST EN 61010-1:2002
Safety Requirement for electrical equipment for measurement, control and laboratory use, part1 : general requirement
Decree on electromagnetic Compatibility (EMC) URLRS 61/00 (Directive 89/336/EEC on electromagnetic compatibility): SIST EN 61036 item 4.5: 1998 Meters for active energy (class 1 and 2)
Safety
Protection Class II
600V rms, installation category II
300V rms, installation category III
Pollution Degree 2 in compliance with SIST EN 61010-1:2002
Enclosure Material
PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0
Enclosure Protection
IP52 (IP00 for terminals) in compliance with SIST EN 60529:1997
Resistance to HF Interference
Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12
Conducted and radiated emissions
Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure)
Operating Temperature
-20 →+70 °C
Datasheet
Product Datasheet
User Manual
LEM HOP 500-SB/SP1 O/L Split Core Hall Effect Current Sensor, 500 Amp, +/-4V Output, 12.5 x 41mm Aperture, +/-12..15V Supply, Panel Mount, X = 2% Open Loop AC/DC Hall Effect Sensor
Features
Bandwidth DC to 8kHz
Open loop transducer using Hall effect
Compact and versatile
Panel mounting-Horizontal or Vertical or Busbar Mounting
Insulated plastic case recognized according to UL 94-V0
Advantages
Very good linearity
Very good accuracy
Low temperature drift
Wide frequency bandwidth
Very low insertion losses
High immunity to external interference
Current overload capability
Low power consumption
Wide dynamic range, nominal 200 to 600 A in one package.
Up to 900 A measurement range
Applications
Power supplies for TELECOM (monitoring and measurement)
Electrical chemistry
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications.
Chopper
Battery supplied applications
Specification
LEM Part Number
HOP 500-SB/SP1
Technology
Open Loop Hall Effect
Aperture
104 x 40mm Square
ROHS
Yes
Supply Voltage
+/-12..15 VDC Bipolar, Isolated
Load Current (RMS + DC)
500 Amp
Measurement Range
+/-1000 Amp
Overload Rating
Contact Us for Possible Replacement
Output
+/-4 V
Isolation
3 kV
Bandwidth
DC-10 kHz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-25°C / 70°C
Accuracy
2%
Termination Style
Molex 5045-04A
Unit Weight
590g
Factory Pack Quantity
4
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
Crouzet Automation 84903020, Three Phase Voltage Control Relay, Phase Sequence or Phase Failure - 17.5 mm EMWS, 208-480 VAC, Self Powered
For Phase Sequence of Phase Failure Monitoring of AC Voltages up to 480VAC
Features:
Control Monitoring of AC voltages
Automatic recognition of AC
Measurement ranges from 288 V to 480 VAC
Choice between under and overvoltage
True RMS measurement
Selectable latching (memory) function
Specification
Crouzet Part Number
84903020 (Three Phase C-Lynx Voltage Monitoring Relay With SPDT Contacts)
Function
Phase Sequence/Phase Failure
Nominal Voltage
1 x 208 - 480 VAC/DC
Digital Outputs
1 x C/O Relays, 250VAC/DC @ 5 Amp
Min Breaking Current
10mA/5VDC
Delay on Threshhold Crossing
0.1 → 3s (0, +10%)
Delay on Pickup
600ms
Alarm Delay on Time (max)
200ms
Reset Time
1500ms
Adjustable Hysteresis
5 - 50% of Threshhold
Maximum Measurement Cycle Time
30ms/True RMS Measurement
Measurement Accuracy
1%
Supply Voltage Range
Same as Measurement 3 x 220 → 3 x 480 V ∿
Termination Style
Screw
Weight
170g
Certification
CE, UL, CSA, GL, ROHS
Factory Pack Qty
1
Over Voltage Category
3 in accordance with IEC/EN 60664-1
Pollution Degree
2 in accordance with IEC/EN 61131-2
Protection rating
IP40 (Front), IP20 (Rear)
Mechanical Resistance
Immunity to vibrations IEC/EN 60068-2-6, test Fc
Immunity to shock IEC/EN 60068-2-27, test Ea
Resistance to HF Interference
Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12
Conducted and radiated emissions
Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure)
Operating Temperature
-20 →+70 °C except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-22
Datasheet
Product Datasheet
Fastron Electronics F41F-1Z-C4-1 24VAC/DC SOCKET ONLY slimline with Spring Terminals for F41F Series Slim Relays
Features
6 Amp @ 1-36 VDC
DIN Rail Mount
Changeover Contact
Ultra slim package
UL Listed
CE Compliant to IEC 60664
IP67
Specification
Fastron Part Number
F41F-1Z-C4 Socket
Switching Type
250VAC or 30VDC Load
Control Input
1-36V AC/DC
Current @ Rated Voltage
6 Amp
Contact Arrangement
1 C/O (Single Pole Changeover)
Approvals
UL, CE
Dimensions
76.6 x 94.7 x 6.2
Ingress Protection
IP20
Relay Type
Fastron F41F Series
Termination Style
Spring
Unit Weight
50g
Factory Pack Qty
100
Datasheet
Datasheet
Suitable Parts
F41F-12-24Z
Fastron Electronics F41F-1Z-C2-4-240VAC, Slimline Relay F41F-60ZS and Socket F41F-1Z-C2-4 with Screw Terminals
Features
6 Amp @ 1-36 VDC
DIN Rail Mount
Changeover Contact
Ultra slim package
UL Listed
CE Compliant to IEC 60664
IP67
Specification
Fastron Part Number
F41F-1Z-C2-4-240VAC
Switching Type
250VAC or 30VDC Load
Control Input
220/240VAC
Current @ Rated Voltage
6 Amp
Contact Arrangement
1 C/O (Single Pole Changeover)
Approvals
UL, CE
Dimensions
76.6 x 94.7 x 6.2
Ingress Protection
IP20
Relay Type
Fastron F41F Series
Termination Style
Screw
Unit Weight
50g
Factory Pack Qty
100
Datasheet
Datasheet
Fastron Electronics F41F-1Z-C2-4, Slimline SOCKET ONLY with Screw Terminals, for F41-60FZS for 220/240VAC Control
Features
6 Amp @ 1-36 VDC
DIN Rail Mount
Changeover Contact
Ultra slim package
UL Listed
CE Compliant to IEC 60664
IP67
Specification
Fastron Part Number
F41F-1Z-C2-4
Switching Type
250VAC or 30VDC Load
Control Input
220/240VAC
Current @ Rated Voltage
6 Amp
Contact Arrangement
1 C/O (Single Pole Changeover)
Approvals
UL, CE
Dimensions
76.6 x 94.7 x 6.2
Ingress Protection
IP20
Relay Type
Fastron F41F Series
Termination Style
Screw
Unit Weight
50g
Factory Pack Qty
100
Datasheet
Datasheet
Suitable Parts
F41F-60ZS
Fastron Electronics F41F-1Z-C4-4 240VAC Socket, Slimline SOCKET ONLY with Spring Terminals, for 220/240VAC Coil F41F Series Slim Relays
Features
6 Amp @ 220/240VAC
DIN Rail Mount
Changeover Contact
Ultra slim package
UL Listed
CE Compliant to IEC 60664
IP67
Specification
Fastron Part Number
F41F-1Z-C4-4 240VAC Socket
Switching Type
250VAC or 30VDC Load
Control Input
220/240VAC
Current @ Rated Voltage
6 Amp
Contact Arrangement
1 C/O (Single Pole Changeover)
Approvals
UL, CE
Dimensions
76.6 x 94.7 x 6.2
Ingress Protection
IP20
Relay Type
Fastron F41F Series
Termination Style
Spring
Unit Weight
50g
Factory Pack Qty
100
Datasheet
Datasheet
Suitable Parts
F41F-60ZS
Schurter 0001.2507, SPT Ceramic 5x20mm Time Lag Fuse 2Amp, 250VAC, 1.5kA, IEC 60127-2
Features
Meets UL and IEC standards
UL Recognized for 250VAC
High breaking capacity of 1.5 kA @ 250VAC
Meets the requirements of IEC 60127-2 for Industrial Medical, Aviation
Applications
Electrical Appliances
Power Supply Adaptors
Switch Mode Power Supplies
Avionics
In-line protection
Specification
Schurter Part Number
0001.2507
Fuse Type
I²t Time lag
Nominal Voltage
250VAC
I²t Rating (Pre-Arcing)
9.2 A²/s
Nominal Current (DC)
2 Amp
Tested Breaking Capacity
1.5kA @250VAC
Dimensions
5 x 20mm
Fuse Holder
0031-2203 Fuse Holders
Mounting Style
Requires fuse holder
Operating Temperature Range
-55°C / 125°C
Watt Loss
0.6W
Unit Weight
1.2g
Factory Pack Qty
10
Datasheet
Product Datasheet
Fuse Holder
0031-2203 Shock Proof Fuse Holders
ISKRA LETRIKA (MAHLE) 16.906.471 AMJ5710 MAHLE DC Motor replacement Brush and Plate
MAHLE Part # MMX724
Specification
ISKRA (MAHLE) Part Number
16.906.471
ISKRA/LETRIKA/MAHLE
16.906.471
Voltage
12VDC
Rotation
Unidirectional
Unit Weight
1.5kg
Factory Pack Qty
1