Fastron HS103DR-FTH6053ZA4, Three Phase Solid State Relay 90-280VAC Control, 3 x 21Amp, 48-530VAC Load, LED Status Indicator, with IP20 Cover
Ratings from 25A to 70 Amp @ 70-530 VAC
SCR output for heavy industrial loads
Zero voltage or Instantaneous turn-on outputs
UL/CE/ROHS Approved
IP20 Cover Available
AC & DC control types
Direct bond copper substrate
Direct power lead frame
Includes IP20 Cover
Specification
Crydom Part Number
HS103DR + FTH6053ZD3
Switching Type
Zero Crossing
ROHS/CE/UL
Yes
Control Voltage
90-280VAC
Load Current
3 x 23 Amp (rms) per Phase
Surge Capability
597 Amp (peak)
Special Feature
LED Status Indicator, with IP20 Cover
Mounting Style
Din Rail Mount
Load Voltage Range
70-530VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
900g
Factory Pack Qty
10
Datasheet
HS103DR
Product Datasheet
Crydom CWA4890P, Solid State Relay, Single Phase 90-280VAC Control, 90A, 48-660VAC Load w/ Overvoltage Varistor
Features
Ratings from 25A to 125 Amp @ 48-660VAC
SCR output for heavy industrial loads
Zero voltage or instantaneous turn-on outputs
UL/CSA/VDE Approved, CE Compliant to EN60950-1
Improved SEMS screw and washer
Redesigned housing with anti-rotation barriers
AC & DC control types
Direct bond copper substrate
EMC compliant to Level 3
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
CWA4890P
Switching Type
Zero Crossing
ROHS
Yes (Details)
Control Voltage
24VAC (18-36VAC)
Load Current
90 Amp (rms)
Surge Capability
1350 Amp (peak)
Special Feature
LED Status Indicator, High Surge, MOV Overvoltage protection
Mounting Style
Panel Mount
Load Voltage Range
48-660VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
75g
Factory Pack Qty
20
Datasheet
Product Datasheet
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Crydom HS301DR + DC60S7, Din Rail Mount DC Solid State Relay, with Heatsink 3-32VDC control, 7A @ 60 Deg C, 60VDC Load
Ratings from 3A to 7 Amp @3-60VDC
SCR output
Zero voltage or instantaneous turn-on outputs
UL/CE/ROHS Compliant
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Spec
Part Number
HS301DR + DC60S7
Switching Type
DC Switching
ROHS/CE/UL
Yes
Control Voltage
3.5-32VDC
Load Current
7 Amp (rms) @ 40 Deg C
Surge Capability
14 Amp (peak)
Special Feature
N/A
Mounting Style
Din Rail or Panel Mount
Recommended Voltage Range
3-60VDC
Max DC Voltage
60VDC
Termination Style
Screw Terminals
Dimensions
L:81mm x W:45mm x D:73.4mm
Unit Weight
296g
Factory Pack Qty
20
Datasheet
HS301DR
DC60 Series
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Crydom B614F-2T, Single Phase Half Controlled Rectifier Bridge, 42.5 Amp, 480VAC Line
Features
For AC or DC Variable Voltage Output Up to 15KW
Electrically insulated base plate
Industrial standard package
2500V Isolation
UL Recognized E72445
Applications
Power Supplies
Rectifier for drives applications
Rectifiers for UPS
Battery Chargers
Spec
Crydom Part Number
B612F-2T
AC Line voltage
480V
Device Configuration
Single Phase Half Controlled Rectifier Bridge,
DC Output @ 85 Deg C
42.5 Amp
Package Size
W:31.7mm L:63.5mm D:19.7mm
Itsm
250 A
VF
1.65V
Tj(max)
125°C
rF
Not Published
Terminals
Faston (6.3mm)
Hole Centres
48.2mm (M5)
Gate Terminals
Faston (6.3mm)
R th(j-c)
0.9°C/W
R th(c-h)
Not Published
Weight
42.5g
Isolation
2.5kV
Factory Pack Qty
20
Certification
UL Listed
Crydom Headquarters
United States
Datasheet
Product Datasheet
Alternatives
See PSD51/18 for higher rated equivalent
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Crydom D5D07, Solid State Relay, DC 3-32VDC control, 7A, 500VDC Load
Features
Ratings from 7A to 100 Amp @ 100-500VDC
Mosfet output for reliable DC switching
Multiple modules can be wired in parallel for higher currents
UL/CSA/VDE Approved, CE Compliant to EN60950-1
Improved SEMS screw and washer
Redesigned housing with anti-rotation barriers
Direct bond copper substrate
EMC compliant to Level 3
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
D5D07
Switching Type
DC Load
ROHS
Yes (Details)
Control Voltage
3.5-32VDC
Load Current
7 Amp DC
Surge Capability (10ms)
19 Amp DC
Special Feature
None
Mounting Style
Panel Mount
Load Voltage Range
0 - 500VDC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
75g
Factory Pack Qty
20
Datasheet
Product Datasheet
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
Equivalent
Contact Us for Possible Replacement
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
FPT-135 5000/5A 5P35 5VA Protection Class CT, 5000/5A, Class 5P35 5VA, 135 x 81mm Aperture
Features
Built In Sealable Terminal Covers
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
VDE0414-44-1, GB1208-2006, EN 60044-1 and IEC 61869-2
Applications
Protection Relays
Safety Equipment
Fault Monitoring
??
Specification
Fastron Electronics Part Number
FPT-135 5000/5A 5P35 5VA
Technology
Protection Class Current Transformer
Ratio
5000/5
Aperture Size
81 x 135mm
VA Rating
5VA
Accuracy Class
Class 5P35
Output
5 Amp AC (?%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-10??C / 50??C
Continuous Current (max)
5000Amp x 1.3
Termination Style
Screw
Stanbards
VDE0414-44-1, GB1208-2006, EN 60044-1 and IEC 61869-2
Unit Weight
7kg
Factory Pack Qty
1
??
Datasheet
Product Installation Guide and Datasheet
??
FPT-135 1500/5A 5P35 5VA Protection Class CT, 1500/5A, Class 5P35 5VA, 135 x 81mm Aperture
Features
Built In Sealable Terminal Covers
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
VDE0414-44-1, GB1208-2006, EN 60044-1 and IEC 61869-2
Applications
Protection Relays
Safety Equipment
Fault Monitoring
??
Specification
Fastron Electronics Part Number
FPT-135 1500/5A 5P35 5VA
Technology
Protection Class Current Transformer
Ratio
1500/5
Aperture Size
81 x 135mm
VA Rating
5VA
Accuracy Class
Class 5P35
Output
5 Amp AC (?%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-10??C / 50??C
Continuous Current (max)
1500Amp x 1.3
Termination Style
Screw
Stanbards
VDE0414-44-1, GB1208-2006, EN 60044-1 and IEC 61869-2
Unit Weight
7kg
Factory Pack Qty
1
??
Datasheet
Product Installation Guide and Datasheet
??
Crydom HS072 + PMP6050WP, Panel Mount Single Phase Proportional Phase Controller with Heatsink, Selectable Input, 480-600VAC, 50 Amps @ 40 Deg C, with Overvoltage Protection
Features
Selectable Proportional Phase or Burst Control Input
Ratings from 25A to 90 Amp @ 170-600 VAC
SCR output for heavy industrial loads
Zero voltage or Instantaneous turn-on outputs
UL/CE/ROHS Compliant
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
HS072 + PMP6050WP
Switching Type
Phase Angle or Burst (Selectable)
ROHS/CE/UL
Yes
Control Voltage
0 - 10V/0 - 5V/4 - 20mA Proportional Input (Selectable)
Note Requires DC Power Supply for 0-5V/0-10V input modes
Load Current
50 Amp (rms)
Surge Capability
716Amp (peak)
Special Feature
Proportional Controller + SSR + Overvoltage Protection
Mounting Style
Panel Mount
Load Voltage Range
420-600VAC
Dielectric Strength
4kV
Termination Style
Terminal Plug
Dimensions
L:139.7 x W:120.1 x 66.8mm
Unit Weight
560g
Factory Pack Qty
20
Datasheet
Product Datasheet
PMP24 Installation/Wiring Guide
HS072
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Crydom HS211 + D2440G, Panel or slide on Din Rail Heatsink, 3-32VDC Control Input, LED Status, 24-280VAC Output, 25 Amps
Features
Ratings from 25A to 125 Amp @24-280 VAC
SCR output for heavy industrial loads
Zero voltage or instantaneous turn-on outputs
UL/CE/ROHS Compliant
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Panel Mount
Din Rail Mount
Spec
Part Number
HS211 + D2440G
Switching Type
Zero Crossing
ROHS/CE/UL
Yes
Control Voltage
4-32VDC
Load Current
25 Amp (rms) @ 40 Deg C
Surge Capability
597 Amp (peak)
Special Feature
LED Status Indicator
Mounting Style
Din Rail or Panel Mount
Load Voltage Range
24-280VAC
Max Non Repetitive Peak Voltage
600 Vp
Termination Style
Screw Terminals
Dimensions
L:81mm x W:45mm x D:73.4mm
Unit Weight
296g
Factory Pack Qty
20
Datasheet
HS211
Series 1 AC
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Oztherm F330 Series 3 Phase SCR Phase Angle Controller Spare Card Set, Can Replace Novatherm C3000 & C3000A
Features
100% Australian Made
3 Phase, Phase Angle Controller or DC Soft Starter
4-20mA, 0-5V, 0-10V or POT input Proportional Phase Control
Fully enclosed IP20
Phase angle switching
Aluminium Frame
Removable perspex Cover
Applications
Electrical Ovens, Kilns, or Furnaces
AC Soft Starter
Controlled Power Applications
Electric Boilers
Brewery Heating
Industrial Light Dimming
Suitable for extreme environments such as mining
Sheet Metal Welding
Available Options
Voltage Regulation AC (A)
Current Limit and Trip AC (C)
Current Limit and Trip DC (CE)
Current Control/Constant Current AC(CC)
Current Control/Constant Current DC(CCE)
Power Limit (PW)
Phase Loss Alarm/Dispable (PH)
Loose Semiconductor Fuses (F)
Internal Semiconductor Fuses (FI)
Thermal Overlad Protection (T)
Special Features
Contact Us for Possible Replacement for customised features
Specification
Oztherm Part Number
F330 Series 3 Phase, Phase Angle Controller
Rated Operationg Temperature
50°C
SCR Configuration
3 Phase AC Swtich
Control Voltage
4-20mA, 0-5V, 0-10V, 10K POT (4-20mA default calibration)
Load Current
N/A
Control Range
0-100%
Special Feature
(Optional) Current Limit & Trip AC or DC, Current Control AC or DC, Voltage Regulation AC, Power Limit, Phase Loss Alarm, Thermal Overload Protection, Fuses
Mounting Style
Panel Mount
Supply Voltage Range
380-440VAC +/-10%
Soft Start
1-20mS
Termination Style
Screw
Unit Weight
up to 10kg
Factory Pack Qty
1
Brochure
F330 Brochure
Technical Docs
Installation and Commissioning Manual
Standard Thyristor Wiring Diagram
Control Card Wiring Diagram F311A1
New CCE option PCB1019-XX Wiring Diagram
Bridge Output Thyristor Wiring Diagram
Primary Transformer Wiring Diagram
Start Delta Wiring Diagram
Calibration Procedure Blog
PDF Copy of Calibration Procedure
Customised models
Customised models list
Contact Us for Possible Replacement for customised features not listed
Shinko ACR13AA/M Series Digital Indicating Controllers
• Program control, converter function are standard features
• 5-digit displays suit most industries including Temperature, Humidity, Pressure (0.5s response)
• Drip-proof / Dust-proof IP66 (front panel only)
• 9-step pattern (for SV and time) is a standard feature
• UL/CSA Approved
• Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
• Each unit needs just 60 mm depth panel space
• EC Compliant (Details)
Specification
Shinko Part Number
ACR13AA/M
Control Output
4 - 20mA
Input
Multirange (refer to datasheet)
Alarm
2 x Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)
Option 1
None
Mounting Style
48 x 96mm Panel Mount
Supply Voltage
100 - 240VAC
Termination Style
Screw
Weight
240g
Factory Pack Qty
1
ROHS
Yes
UL
Yes
CE
Yes
Datasheet
ACR Series Brochure
ACR Series Instruction Manual
ACR Series RS485 Comms Instruction Manual
Delivery 2-3 weeks delivery if not in stock