Search results for "tg@tetherzon$*오다집수수료코인이체구입"
-
FESCT-32-600-100mA, 600Amp/100mA measurement Split Core CT's, Class 1, w/1M Flying Leads, HY2.0 Connection, 32x32mm Aperture
Fastron Electronics FESCT-32-600-100mA, 600Amp measurement Split Core CT's, w/1M Flying Leads, HY2.0 Connection, 32x32mm Aperture, 100mA Class 1 Series Current Transformer Features Quick Release Split Core System 1m Flying Leads Mounting Feet Supplied Self Powered Rated System Voltage 0.60/2kV Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number FESCT-32-600-100mA Technology Split Core AC Current Transformer Ratio 600/100mA Aperture Size 32 x 32mm VA Rating N/A Accuracy Class Class 1 Output 100mA (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 55°C Continuous Current (max) 600Amp x 1.2 Termination Style 1M Twisted Pair 0.34mm^2 Unit Weight 350g Factory Pack Qty 9 Datasheet Product Datasheet Application Notes Installation Guide
$82.50
$97.35 inclGST -
GT-D-C-SP03, 0-300VDC Voltage Transducer/Transmitter, 22-60VAC/DC aux, 4-20mA output
Fastron Electronics GTD-D-C-SP03, 0-300VDC Voltage Transducer/Transmitter, 22-60VAC/DC aux, 4-20mA output Adjustable Zero and Span Setting 250mS Response Time PC 94 UL V0 Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type) Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space Specification Fastron Electronics Part Number GTD-D-C-SP03 Control Output 4-20mA Input 0 - 300VDC Over Range x 1.5 Operating Temperature 0 - 60°C Load Voltage 22 - 60VDC Span Adjustment Range +/-10% Zero Adjustment Range +/-5% Termination Style Screw Mounting Style DIN Rail Mount Case Material PC - UL 94 V0 Weight 170g Factory Pack Qty 1 Datasheet Product Datasheet
$219.00
$258.42 inclGST -
FP300160P, 3000/5 Amp Split Core CT, Class 0.5 15VA, 80 x 160mm Aperture, Dimensions 185 x 53 x 248mm
FP300160P, 3000/5 Amp Split Core CT, Class 0.5 15VA Series Clip On Current Transformer Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Electronics Part Number FP300160P Technology Split Core AC Clip On Current Transformer Ratio 3000/5 Aperture Size 80 x 160mm VA Rating 15VA Accuracy Class Class 0.5 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -30°C / 85°C Continuous Current (max) 2000Amp x 1.2 Certifications CE Termination Style Screw Unit Weight 1150g Factory Pack Qty 1 Datasheet Product Datasheet Installation Guide
$265.00
$312.70 inclGST -
FRTD-PT100-ADH-45-35-0.7-3000, PT100 Surface Temperature Sensor, Adhesive Type, -50 to 180 Deg C, PT100, with Self Ahdhesive surface, 3M Teflon Wire
Fastron FRTD-PT100-ADH-45-35-0.7-3000, PT100 Surface Temperature Sensor , Adhesive Type, -50 to 180 Deg C, PT100, with Self Ahdhesive surface, 3M Teflon Wire, #TC-SEN04-PT100-3-A Class A Accuracy CE, ROHS Pt100 output 3 wire Teflon Cable Rated for -50 to 350 Deg C Max 3000mm Tail 45x35mm Surface Adhesive Probe Specification Fastron Part Number FRTD-PT100-ADH-45-35-0.7-3000 (TC-SEN04-PT100-3-A) Sensor Type RTD - Resistance Temperature Detectors (Adhesive type) No of Wires 3 Sensor Plate DImensions 35x45mm Probe Thickness 0.7mm (35x45mm Surface Plate) Approvals CE, ANSI, ROHS Accuracy Class A Cable length 3 Meter Cable Type Teflon Maximum Temperature -50 to 180 Deg C Special Feature Spring Cable Strain Relief Mounting Style Surface Mount / Adhesive Weight 800g Factory Pack Qty 1 Datasheet Datasheet
$89.00
$105.02 inclGST -
EM94-Z-V3-M-D, Panel Mount DC kWh Meter, Class 0.5, 50-150mV Shunt input, 201-1000VDC, 2 Alarm/Pulse Outputs, RS485 & USB Comms, Single Line LCD Display,12-60VAC/DC Aux Supply, Internal Logging
Free Aus Post Shipping for $300 spendRisbabh EM94-Z-V3-M-D, Panel Mount DC kWh Meter, Class 0.5, 50-150mV Shunt input, 201-1000VDC, 2 Alarm/Pulse Outputs, RS485 & USB Comms, Single Line LCD Display,10-60VAC/DC Aux Supply, Internal Logging 2 Pulse/Alarm Outputs 50-150mV Shunt Input, and nominal voltage 201-1000VDC RS 485 communication up to 57,600 bit/s USB Port 8MB Internal Storage DC Measurement Only The meter is intended for measuring, analysing and monitoring DC Power. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current,, energy, power.) from the measured signals. Features : 96 x 96mm Panel Mount Accuracy class 0.5 Simple Menu RS 485 communication up to 57,600 bit/s USB Comms 8MB Internal Logger 10-60VAC/DC power supply Specification Rishabh Part Number EM94-Z-V1-M-D Functions kWh Meter, Energy Meter Supply Voltage 10-60VAC/DC Nominal Measurement Range 201-1000VDC Maximum Measurement Range 60-300VDC Display Single Line LCD Pulse/Relay Output 2 Accuracy Class 0.5 (Energy) USB YES Real Time Clock 1min/month (30ppm) Isolation 3.5kV RS485 Modbus RTU YES 57,600bps Weight 450g Certification EN 61010-1 Installation Category III Factory Pack Qty 1 Environment IP54 Safety Protection Class II Enclosure Material Mablex with fire protection to UL94-V-O. Self extinguishing EnclosureSize 96 x 96mm x 83.5mm (72mm behind panel) Terminals Rising Cage 4mm² (12 AWG) cable max Humidity < 75% Non Condensing Operating Temperature -20 →+70 °C Datasheet Product Datasheet Software Software User Manual Software Download Link Application Notes 1)Reading Data from Registers -> Download file 2)Maximum Memory Size -> Read below Max Available Memory Locations in 8MB Size = 273030 Actual parameter stored in Each log (Memory locations used) = Date +time+Number of parameter selected by user Considering your example for 2 parameters: Number of parameter selected by user = 2 (kwh & kVA) Actual parameter stored in Each log = 1(Date) +1(time)+ 2 (Parameters) = 4 (memory locations used per log) Maximum log that can be stored = Max Memory Location/Actual parameter stored in Each log =273030/4= 68257 Timelog Interval setting = 15 minutes Log in one day = (60 /Timelog Interval setting) * 24 =(60/15)*24 = 96 Logs Max Days = Maximum log that can be stored / log in one day = 68257 / 96 = 711 days = 1 Year & 11 Months = 23 Months.
Free Aus Post Shipping for $300 spend$309.00
$364.62 inclGST -
SCT-F36-300, 0.333V, 300Amp Measurement, Class 1 Split Core CT's Class 1, 35mm Aperture
Fastron Electronics SCT-F36-300, 0.333V, 300Amp measurement Split Core CT's Class 1, 36mm Aperture Features Quick Release Split Core System Cable Mount 0.333V Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number SCT-F36-300 Technology Split Core AC Current Transformer Ratio 300/0.333V Aperture Size ø 35 mm VA Rating N/A Accuracy Class Class 1 Output 0.333V (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 300Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 400g Factory Pack Qty 9 Datasheet Product Datasheet Stocked Split Core CT's Listing Application Notes Installation Guide Types of Current Transformers - Blog Cable Losses and CT's High Accuracy or High Burden Requirements for CT's
$66.50
$78.47 inclGST -
RCT-2400-Coil, Single Phase, 8 Inch Rogowski Coil. Requires Integrator or suitable Rogowski Coil meter
RCT-2400-Coil, Single Phase, 8 Inch Rogowski Coil. Requires Integrator or suitable Rogowski Coil meter The RCS-2400 Single Phase flexible rope CT from Magnelab converts AC input current to mV/kA output. Included is an 24 inch circumference rope CT with Integrator, and 8 feet of twisted pair (600V) output leads. Note 8 Inch Diameter when not flexed Magnelab Coils come with 10 year warranty Specification Magnelab Part Number RCT-2400-Coil Function AC Current Measurement Nominal Measurement Current (Ipn) N/A Measurement Range 10% - 130% if Ipn Frequency Measuring Range 50-1500Hz (15th Harmonic) Operating Voltage N/A Accuracy 0.5% Phase Angle < 0.5 Degrees Coil Diameter (⌀) 8 Inch Coil Circumference 24 Inch Integrator to Coil Cable 8 Feet Shielded Maximum Voltage 600V (on bare conductor) Operating Temperature -15°C to 65°C Storage Temperature -45°C to 80°C Power Consumption < 2VA Overload 20,000 Amp (continuous) Termination Style Screw Weight 500g Certification CE Factory Pack Qty 1 Certifications UL Recognized E96927 to IEEE C57.13, CAN/CSA 60044-1 Meets UL STD 61010-1, CAN/CSA C22.2 No. 61010 CE ROHS Datasheet Product Datasheet Application Notes RCS/RCT Series Installation Guide
$249.50
$294.41 inclGST -
SCT-F24-100-0.2V, 200mV, 100Amp Measurement, Class 1 Class 1 Split Core CT's for Power Quality Analysers 2mV/Amp
Fastron Electronics SCT-F24-100-0.2V, 200mV, 100Amp Measurement Class 1 Split Core CT's for Power Quality Analysers 2mV/Amp Features Quick Release Split Core System Cable Mount 200mV Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number SCT-F24-100-0.2V Technology Split Core AC Current Transformer Ratio 100/200mV Aperture Size ø 24 mm VA Rating N/A Accuracy Class Class 1 Output 200mV (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 100Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 100g Factory Pack Qty 9 Datasheet Product Datasheet Application Notes Installation Guide
$55.25
$65.20 inclGST -
FDV-200-V05-12, DC Voltage Transducer, Din Rail Mount, 0-200VDC, 0-5V output, 12VDC Supply Voltage, 150mS Response
Free Aus Post Shipping for $300 SpendFastron FDV-200-V05-12, DC Voltage Transducer, Din Rail Mount, 0-200VDC, 0-5V output, 12VDC Supply Voltage, 150mS Response 150mS Response Time PC 94 UL V0 Input signals can be converted to insulated 5V DC output (for voltage output type) Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space Specification Fastron Part Number FDV-200-V05-12 Analogue Output 0-5V Input 0 - 200VDC Measurement Range 120% Overload 150% Continuous Operating Temperature -30 - 70°C Operating Voltage 12VDC +/-15% Voltage Isolation (1 min) 2.5kV Accuracy 1% Response Time 150mS Termination Style Screw Mounting Style DIN Rail Mount Safety CE, UL94V0 Weight 170g Factory Pack Qty 1 Datasheet Product Datasheet
Free Aus Post Shipping for $300 Spend$265.00
$312.70 inclGST -
FESCT-19-100-100mV, 100Amp measurement Split Core CT's, Class 1, w/1M Flying Leads, HY2.0 Connection, 19x19mm Aperture
Fastron Electronics FESCT-19-100-100mV, 100Amp measurement Split Core CT's, Class 1, w/1M Flying Leads, HY2.0 Connection, 19x19mm Aperture Current Transformer Features Quick Release Split Core System 1m Flying Leads Mounting Feet Supplied Self Powered Rated System Voltage 0.60/3kV Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number FESSCT-19-100-100mV Technology Split Core AC Current Transformer Ratio 100/100mV Aperture Size 19 x 19mm VA Rating N/A Accuracy Class Class 1 Output 100mVAC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 55°C Continuous Current (max) 100Amp x 1.2 Termination Style 1M Twisted Pair 0.34mm^2 Unit Weight 350g Factory Pack Qty 9 Datasheet Product Datasheet Application Notes Installation Guide
$72.50
$85.55 inclGST -
SCT-F36-600-040A, 40mA, 600Amp Measurement, Class 1 Split Core CT's
Free Aus Post Shipping for $300 SpendFastron Electronics SCT-F36-600-040A, 40mA, 600Amp Measurement, Class 1 Split Core CT's Features Quick Release Split Core System Cable Mount 40mA Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number SCT-F36-600-040A Technology Split Core AC Current Transformer Ratio 600/40mA Aperture Size ø 35 mm VA Rating N/A Accuracy Class Class 1 Output 5 Amp (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 600Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 400g Factory Pack Qty 9 Datasheet Product Datasheet Stocked Split Core CT's Listing Application Notes Installation Guide Types of Current Transformers - Blog Cable Losses and CT's High Accuracy or High Burden Requirements for CT's
Free Aus Post Shipping for $300 Spend$66.50
$78.47 inclGST -
FDV-150-V05-24, DC Voltage Transducer, Din Rail Mount, 0-150VDC, 0-5V output, 24VDC Supply Voltage, 150mS Response
Fastron FDV-50-V05-24, DC Voltage Transducer, Din Rail Mount, 0-150VDC, 0-5V output, 24VDC Supply Voltage, 150mS Response 150mS Response Time PC 94 UL V0 Input signals can be converted to insulated 5V DC output (for voltage output type) Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space Specification Fastron Part Number FDV-50-V05-24 Analogue Output 0-5V Input 0 - 50VDC Measurement Range 120% Overload 150% Continuous Operating Temperature -30 - 70°C Operating Voltage 24VDC +/-15% Voltage Isolation (1 min) 2.5kV Accuracy 1% Response Time 150mS Termination Style Screw Mounting Style DIN Rail Mount Safety CE, UL94V0 Weight 170g Factory Pack Qty 1 Datasheet Product Datasheet
$265.00
$312.70 inclGST