D2425D, Dual Solid State Relay, Two Pole 4-15VDC Control, 2 x 25A, 24-280VAC Load
Crydom D2425D, Dual Solid State Relay, Two Pole 4-15VDC Control, 2 x 25A, 24-280VAC Load Features Ratings from 2 x 25A to 2 x 40 Amp @ 24-530 VAC SCR output for heavy industrial loads Zero voltage or instantaneous turn-on outputs UL/CSA/VDE Approved, CE Compliant to EN60950-1 Improved SEMS screw and washer Redesigned housing with anti-rotation barriers AC & DC control types Direct bond copper substrate EMC compliant to Level 3 Direct power lead frame Epoxy free design Spec Crydom Part Number D2425D Switching Type Zero Crossing (Dual) ROHS Yes (Details) Control Voltage 4-15VDC Load Current 25 Amp (rms) Surge Capability 250 Amp (peak) Special Feature Dual SSR Mounting Style Panel Mount Load Voltage Range 24-280VAC EMC Compliant Level 3 Termination Style Screw Unit Weight 75g Factory Pack Qty 20 Datasheet Product Datasheet Notifications Please note Changes from Gen 3 to Gen 4 (current) package design here App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies
$147.95
$174.58 inclGST -
Fast ONE Complete AHF 400A-400V, Active Harmonic Filter & Static Var Generator, 400 Amp / 280 Kvar @ 45 Deg C, 3 Phase 3 Wire, 400VAC +/-20%, L:950 x W:950 x H:2200mm
Heavy Item - No Free ShippingFast ONE Complete AHF 400A-400V, Active Harmonic Filter & Static Var Generator, 400 Amp / 280 Kvar @ 45 Deg C, 3 Phase 3 Wire, 400VAC +/-20%, L:950 x W:950 x H:2200mm For Automatic Switching of Power Factor Correction Capacitors according to changing site conditions. and for the filtering or control of Harmonic Distortion Features Automatic Power Factor Correction up to Cos φ = 0.99 Overtemperature Alarm Optional RS485 Comms IEC 654-1, UL Approved 3 Year Fastron Electronics Warranty Modular Construction for Rack or Wall Mount Installations Perfect for Residential Applications Stack multiple modules for larger Power Factor Correction Requirements Specification Fastron Part Number Fast ONE Complete AHF 400A-400V Function Reactive Power Correction & Active Harmonic Filter Configuration 4 x 100 Amp/70Kvar Modules Current /Load Rating 400 Amp per Phase (360 Amp @ 55 Deg C)/280 Kvar Nominal Voltage (Un) 400VAC Line to Line 50Hz Switch Delay Time Instant Correction/Inverter Based Desired Harmonic 0.99 IND - 0.99 CAP LCD Display IGBT Temp, Grid Current Grid THDi, Grid PF, Grid Imbalance PCurrent imbalance < 5% Comms RS485 (Optional) Termination Style Screw Dimensions L:950 x W:950 x H:2200mm Weight 520kg Certification EN 61000-6-4:2007+A1:2011 EN 61000-6-2:2005 EN 61000-3-2:2014 EN 61000-3-3:2013+A1:2019 Factory Pack Qty 1 Material of housing PC/ABS Unflammable, according to UL 94 V-0, & Stainless Steel Painted RAL 1013 Enclosure protection IP21 Safety According to EN 61 010-1, installation category III Pollution degree 2 Operating Temperature -20...55 °C Datasheet AHF Module Datasheet Complete with Enclosure Datasheet User Manual
Heavy Item - No Free Shipping$37,500.00
$44,250.00 inclGST -
H10 Heatsink, Full Lengths or cut to order, Milled or Raw Finish
H10 Heatsink Profile 110mm x 240mm, Various Lengths cut to order, Milled or Raw Finish Datasheet Product Datasheet Heatsink Data New Heatsink Data Book Old Heatsink databook with additional thermal data
$155.00 - $1,030.00
-
FPT-135 1000/1A 5P20 15VA, Protection Class CT, 1000/1A, Class 5P20 15VA, 135 x 81mm Aperture
Heavy Item - No Free ShippingFPT-135 1000/1A 5P20 15VA Protection Class CT, 1000/1A, Class 5P20 15VA, 135 x 81mm Aperture Features Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV VDE0414-44-1, GB1208-2006, EN 60044-1 and IEC 61869-2 Applications Protection Relays Safety Equipment Fault Monitoring ?? Specification Fastron Electronics Part Number FPT-135 1000/1A 5P20 15VA Technology Protection Class Current Transformer Ratio 1000/5 Aperture Size 81 x 135mm VA Rating 15VA Accuracy Class Class 5P20 Output 1 Amp AC (?%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -10??C / 50??C Continuous Current (max) 1000Amp x 1.3 Termination Style Screw Stanbards VDE0414-44-1, GB1208-2006, EN 60044-1 and IEC 61869-2 Unit Weight 7kg Factory Pack Qty 1 ?? Datasheet Product Installation Guide and Datasheet ??
Heavy Item - No Free Shipping$505.00
$595.90 inclGST -
84872142, Single Phase Voltage Control Relay Under/Overvoltage Detection - 17.5 mm MUS, 65-260 VAC/DC Measurement/Supply, Replaces DSR2 Series
Crouzet Automation 84872152, Single Phase Voltage Control Relay Under/Overvoltage Detection - 17.5 mm MUS, 65-260 VAC/DC Measurement/Supply, Replaces DSR2 Series For under and over voltage monitoring of Single phase AC or DC Voltages 65 to 260V Features: Control of AC and DC voltages Automatic recognition of AC/DC Measurement ranges from 65 V to 260 V Choice between under and over voltage True RMS measurement Selectable latching (memory) function Specification Crouzet Part Number 84872142 (Single Phase MUSF Voltage Monitoring Relay With Non-Latching SPDT Contacts) Function Undervoltage/Overvoltage Supply Voltage 65 - 260 VAC/DC Measurement Voltage 1 x 15-600VAC/DC Digital Outputs 1 x C/O Relays, 250VAC/DC @ 5 Amp Min Breaking Current 10mA/5VDC Delay on Threshhold Crossing 0.1 → 3s (0, +10%) Delay on Pickup 600ms Alarm Delay on Time (max) 200ms Reset Time 1500ms Adjustable Hysteresis 5 - 50% of Threshhold Maximum Measurement Cycle Time 30ms/True RMS Measurement Measurement Accuracy 1% Supply Voltage Range Same as Measurement Termination Style Screw Weight 170g Certification CE, UL, CSA, GL, ROHS Factory Pack Qty 1 Over Voltage Category 3 in accordance with IEC/EN 60664-1 Pollution Degree 2 in accordance with IEC/EN 61131-2 Protection rating IP40 (Front), IP20 (Rear) Mechanical Resistance Immunity to vibrations IEC/EN 60068-2-6, test Fc Immunity to shock IEC/EN 60068-2-27, test Ea Resistance to HF Interference Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12 Conducted and radiated emissions Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure) Operating Temperature -20 →+70 °C except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-22 Datasheet Product Datasheet
$267.00
$315.06 inclGST -
SCT-F16-100-5A, 100/5Amp Measurement, Class 1 Split Core CT's
Fastron Electronics SCT-F16-100-5A, 5 Amp Output, 100Amp measurement Split Core Current Transformer Features Quick Release Split Core System Cable Mount 5 Amp Output Self Powered Rated System Voltage 0.60/3kV 0.5M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number SCT-F16-100-5A Technology Split Core AC Current Transformer Ratio 100/5A Aperture Size ø 15 mm VA Rating 1VA Accuracy Class Class 1 Output 5 Amp (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 100Amp x 1.2 Termination Style 0.5M Flying leads Unit Weight 100g Factory Pack Qty 9 Datasheet Product Datasheet Application Notes Installation Guide
$45.00
$53.10 inclGST -
NBR-FR22GR69V40T + RT18-125L Series 40 Amp 690V Semiconductor I²t Fuse Cartridge Style
Trent NBR-FR22GR69V40T + RT18-125L Series 40 Amp 690V Semiconductor I²t Fuse & DIN Rail Fuse Holder Cartridge Style (3pcs) Features Cylindrical Standard Fuses Sizes Wide Range of I²t Ratings up to 125 Amp Quick Release with RT18-125L fuse holder DIN Rail Mount with RT18-125L fuse holder Compatible with all 58 x 21mm fuse holders IEC Standard 60269.1 AND 4 690 V Voltage Rating complying with IEC 33 Applications Solid State Relay Switchboards Bridge rectifier Fusing Protection of High Powered Semiconductors according to I²t Short Circuit Protection DC or AC Motor I²t Protection Battery Fuse Specification Trent Part Number NBR-FR22GR69V40T + RT18-125L Fuse Type I²t gR Class Nominal Voltage 690VAC @ 50Hz I²t Rating (Pre-Arcing) 750 A²/s Nominal Current (RMS + DC) 40 Amp Tested Breaking Capacity 200kA @ 690VAC Dimensions 123 x 76 x 37.5mm Fuse Holder RT18-125L Mounting Style Din Rail Mount Operating Temperature Range -40°C / 125°C Watt Loss 9.5W DC Breaking Capacity 50kA Unit Weight 60g Factory Pack Qty 10 Datasheet RT18-125L Datasheet
$40.00
$47.20 inclGST -
NBR-FR22GR69V20T + RT18-125L Series 20 Amp 690V Semiconductor I²t gR Fuse & DIn Rail Fuse Holder Cartridge Style
Trent NBR-FR22GR69V20T + RT18-125L Series 20 Amp 690V Semiconductor I²t gR Fuse & DIn Rail Fuse Holder Cartridge Style Features Cylindrical Standard Fuses Sizes Wide Range of I²t Ratings up to 20 Amp Quick Release with RT18-125L fuse holder DIN Rail Mount with RT18-125L fuse holder Compatible with all 58 x 21mm fuse holders IEC Standard 60269.1 AND 4 690 V Voltage Rating complying with IEC 33 Applications Solid State Relay Switchboards Bridge rectifier Fusing Protection of High Powered Semiconductors according to I²t Short Circuit Protection DC or AC Motor I²t Protection Battery Fuse Specification Trent Part Number NBR-FR22GR69V20T + RT18-125L Fuse Type I²t gR Class Nominal Voltage 690VAC @ 50Hz I²t Rating (Pre-Arcing) 260 A²/s Nominal Current (RMS + DC) 20 Amp Tested Breaking Capacity 200kA @ 690VAC Dimensions 123 x 76 x 37.5mm Fuse Holder RT18-125L Mounting Style Din Rail Mount Operating Temperature Range -40°C / 125°C Watt Loss 22.8W DC Breaking Capacity 50kA Unit Weight 60g Factory Pack Qty 10 Datasheet RT18-125L Datasheet
$40.00
$47.20 inclGST -
PhMKPg440.3.18.80-84, Power Factor Correction Capacitor, 440VAC 3 Phase, 85 x 265mm IP00 Dry Type (Gas Filled), 18KVAR @ 440VAC, 16.7KVAR @ 415VAC, 3 x 96.2uF
Vishay PhMKPg440.3.18.80-84, Power Factor Correction Capacitor, 440VAC 3 Phase, 85 x 265mm IP00 Dry Type (Gas Filled), 18KVAR @ 440VAC, 16.7KVAR @ 415VAC, 3 x 96.2uF Characteristics and utility 16.7kVar @ 440VAC @ 50 Hz 10.0kvar 10kvar Three phase capacitor DUAL WINDING internally delta connected Discharge resistors Incorporated Reactive power factor correction Dry type Connector type - single sided terminal Indoor mounting Triple safety Overpressure disconnection system Protection by internal fuses Self Healing Construction and materials Low losses metallized self-healing polypropylene film, high density, high temperature and greater dielectric resistance Volt/µ UL 94 V0 Resin Aluminium case with bottom fixing M12x16 Standards IEC 60831-1/2 EN 60831-1/2 Specification Vishay Part Number PhMKPg440.3.18.80-84 Technology Gas Filled, Low Loss, Self Healing Dimensions 85 x 265mm Standards IEC 60831-1/2, EN 60831-1/2 Voltage 440V @ 50Hz Size 85 x 265mm Kvar 18.8 Kvar (16.7KVAR @ 415VAC) Capacitance 3 x 96.2uF Tolerance On Capacitance -5% + 10% (others on request) Current (In) 27.5 Amp Overpressure Disconnection System YES Self Extinguishing Resin YES Internal Fuses YES Self Healing YES Mounting M12 x 16mm (Indoor) Operating Temperature Range 50°C Max, 30°C Mean(1 year), 40°C Mean(24 hrs) Lifetime 120,000 Hours Termination Style Ceramic Busbar/Feed Through Type Unit Weight 1.7kg Factory Pack Quantity 25 Datasheet Product Datasheet Application Notes Discharge Resistor Usage Power Factor Correction Blog
$189.00
$223.02 inclGST -
SCT-F50-250-5A, 5 Amp, 250Amp measurement Split Core CT's
Fastron Electronics SCT-F50-250-5A, 5 Amp, 250Amp measurement Split Core CT's Features Quick Release Split Core System Cable Mount 5 Amp Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number SCT-F50-250-5A Technology Split Core AC Current Transformer Ratio 250/5 Amp Aperture Size ø 50 mm VA Rating N/A Accuracy Class Class 1 Output 5 Amp (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 250Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 1000g Factory Pack Qty 9 Datasheet Product Datasheet Stocked Split Core CT's Listing Application Notes Installation Guide Types of Current Transformers - Blog Cable Losses and CT's High Accuracy or High Burden Requirements for CT's
$110.55
$130.45 inclGST -
TCD-L-1-K HEATING Temp Controller, 96x96mm 230VAC, C/O Relay output, Type K Input. Encoder Control, Digital Display, 0-999 Deg C
TCD-L-1-K HEATING Temp Controller, 96x96mm 230VAC, C/O Relay output, Type K Input. Encoder Control,amp; Digital Display, 0-999 Deg C Pushbutton Encoder Setpoint 3-digit display (0.5s response) Drip-proof / Dust-proof IP66 (front panel only) Input signals can be converted to insulated ON/OFF Relay, output, Optional cooling or time proprtional versions output available Each unit needs just 75 mm depth panel space Specification Fastron Part Number TCD-L-1-K Control Output Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4) Input Type K Thermocouple Control Mode Heating ON/OFF Control Control Range 0- 999 Deg C Mounting Style 96x96mm Panel Mount Supply Voltage 230VAC Termination Style Screw Sampling Time 50ms Weight 270g Factory Pack Qty 1 Datasheet TCD/TCR/FC5 Datasheet TCD/TCR User Manual
$105.00
$123.90 inclGST -
RI61J C 25-10kA, 1 Pole DC Miniature Circuit Breaker Disconnect Switch C Curve 25 Amp, 220VDC, 10kA
Iskra Doo RI61J C 25-10kA, 1 Pole DC Miniature Circuit Breaker Disconnect Switch C Curve 25 Amp, 220VDC, 10kA Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : < 50mS Trip Delay Time 1 Pole Disconnect 10kA Short Circuit Rating Suitable for Isolation Customised versions available Type B, C, D Curve available Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 Specification Iskra Doo Part Number RI61J C25 Functions 1 Pole MCB - C Curve Nominal Voltage 220VDC Nominal Current Range 25 Amp RMS Trip Delay Time < 50ms Rated Frequency 50/60 Hz Operating Temperature -25 to 55 Deg C Rated Operations 10,000 Ops Surge Current 220V Short Circuit Current 10kA Approvals VDE, GOST-R Standards IEC/EN 60898,60947-1/2, IP20 (IP40 Installed) IEC 61008 ; Weight 130g Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet
$19.95