Crydom CKRD6030, Solid State Relay, Single Phase 3.5 - 32VDC Control, 30A, 48-660VAC Load, Din Rail
Features
Ratings from 10A to 30 Amp @ 48-530 VAC
SCR output for heavy industrial loads
Zero voltage or instantaneous turn-on outputs
UL/CSA/VDE Approved, CE Compliant to EN60950-1
Improved SEMS screw and washer
Redesigned housing with anti-rotation barriers
AC & DC control types
Direct bond copper substrate
EMC compliant to Level 3
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
CKRD6030
Switching Type
Zero Crossing
ROHS
Yes (Details)
Control Voltage
4 - 32VDC
Load Current
30 Amp (rms) @ 25 Deg C Ambient, 25.5 Amp (rms) @ 40 Deg C Ambient
Surge Capability
1200 Amp (peak)
Special Feature
None
Mounting Style
DIN Rail Mount
Load Voltage Range
48 - 660VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
280g
Factory Pack Qty
20
Datasheet
Product Datasheet
Alternatives
Contactor Style DR2260D35V
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Crydom ED24C5, EMR plug in Solid State Relay, 18-32VDC control, 5 Amp 24-280VAC output
Features
Ratings 5 Amp @ 24-280VAC
Plug in EMR relay style
Motor controller rated
SCR output for reliable AC switching
Multiple modules can be wired in parallel for higher currents
UL/CSA/VDE Approved, CE Compliant to EN60950-1
EMC compliant to Level 3
Epoxy free design
Spec
Crydom Part Number
ED24C5
Switching Type
AC Load
ROHS
Yes (Details)
Control Voltage
18-32VDC
Load Current
5 Amp DC
Surge Capability (10ms)
60 Amp DC
Special Feature
Plug in EMR style
Mounting Style
EMR Base
Load Voltage Range
24-280VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
38g
Factory Pack Qty
10
Datasheet
Product Datasheet
Socket
DRSED
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Fastron Electronics FESCT-19-250-0.333V, 250Amp measurement Split Core CT's, w/1M Flying leads, 19x19mm Aperture, 0.333v Class 1 Series Current Transformer
Features
Quick Release Split Core System
1m Flying Leads
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.60/3kV
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
FESSCT-19-250-0.333V
Technology
Split Core AC Current Transformer
Ratio
250/0.333V
Aperture Size
19 x 19mm
VA Rating
N/A
Accuracy Class
Class 1
Output
0.333VAC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 55°C
Continuous Current (max)
250Amp x 1.2
Termination Style
1M Twisted Pair 0.34mm^2
Unit Weight
350g
Factory Pack Qty
9
Datasheet
Product Datasheet
Application Notes
Installation Guide
Gigavac GXL14C2AB, Latching Contactor SPST-NO, 350+ AMP, 12-800VDC, 24VDC Coil, 38cm Flying leads, SPST-NO Auxiliary Contact, IP67, IP69K, Low Side Drive Version
Features
Hermetically Sealed (Patented) rated to 175 Deg C
UL1604 for Class I & II Div 2 and Class III for use in hazardous locations
IP67 & IP69K
SAE J1171 External ignition protection
ISO8846 Protection against ignition around flammable gasses
CE Approved
High Efficiency Dual DC Coils - Very low 12,24,48VDC continuous coil power with no EMI emissions or cross-talk on your system control power
Ideal for battery powered systems or where low power is needed
PWM option provides additional drive control flexibility
Built in Coils suppression for all DC Coils
Flexible package for installation
Chassi level power terminals
Salt Fog MIL-STD-810
Specification
Gigavac Part Number
GXL14C2AB
Main Contact Type
SPST-NO
Auxiliary Contact Type
SPST-NO
Coil Voltage
24VDC (Low Side Drive, refer datasheet)
Load Current
350+ Amp
Mechanical Life @ 0 Amp
1,000,000 Operations
Dielectric at Sea Level (leakage <1mA)
2.2kV rms
Control Input Terminals
38cm Flying Leads
Aux Contact Terminals
38cm Flying Leads
Special Feature
Hermetically Seal rated to 175 Deg C
Mounting Style
Panel Mount (M5)
Load Voltage Range
12-800VDC
Standards
UL1604, IP67, IP69K, SAE J1171, ISO8846
Termination Style
M8
Unit Weight
440g
Factory Pack Qty
1
Datasheet
Product Datasheet
Iskra Doo KNL38-00-240VAC, AC Contactor 240/400/500/690V, Overload 304(10s), 320(5s), 350(1s), 900(0.001s) (each pole), 240VAC Control Voltage, 3 Pole 3 x NO, Nominal Current = 38 Amps
Capacitor duty contactors are designed to meet the requirements of capacitor duty applications. Contactors are fitted with a block of three auxiliary contacts connected in series with six quick discharge damping resistors, two per each phase. Peak current is limited to the value within the contactor making capacity.
Features :
High contact reliability at low voltages
High electrical and mechanical endurance and high switching capacity
Four and Three-pole contactors
Optional auxiliary contacts
Ratings from 6 Amp to 1000 Amp
UL, CSA Approved
Advantages :
Saves costs of expensive replacement
Long electrical life
Reduces watt losses during “ON” condition, saves energy
High safety
No risk of dangerous voltage
Less maintenance and downtime
Standard control voltages: 24 V 50/60 Hz, 240 V 50/60 Hz, 415 V 50/60 Hz
Specification
Iskra Doo Part Number
KNL38-00-240VAC
Functions
3 Pole Contactor (3 x NO)
Nominal Voltage
230/400/500/690VAC @ 50/60Hz
Current Carrying Capacity as per UL
38 Amp Continuous @ 55 Deg C
Overload Capability
304(10s), 320(5s), 350(1s), 900(0.001s)
Auxiliary Contacts
Optional Snap On 4 Pole NPL3
Trip Delay Time
2-10ms
Electrical Life
200,000 Ops
Operating Temperature
-25 to 55 Deg C
Mechanical Operations
10.000,000 Ops
Control Voltage
240VAC
Power Dissipation
2.3W
Approvals
UL, CSA
Standards
IEC/EN 60947-4-1, AS/NZ 61009-1
Weight
200g
Enclosure Material
UL94
Factory Pack Qty
1
Datasheet
Product Datasheet
Contactor Catalogue
Iskra Contactor Catalogue
Iskra Doo KNL75-11-240VAC, AC Contactor 240/400/500/690V, 3 Pole 3 x NO, with 1 x NO 1 x NC Aux Contacts, Nominal Current = 75 Amps, 240VAC Coil
Capacitor duty contactors are designed to meet the requirements of capacitor duty applications. Contactors are fitted with a block of three auxiliary contacts connected in series with six quick discharge damping resistors, two per each phase. Peak current is limited to the value within the contactor making capacity.
Features :
High contact reliability at low voltages
High electrical and mechanical endurance and high switching capacity
Four and Three-pole contactors
Optional auxiliary contacts
Ratings from 6 Amp to 1000 Amp
UL, CSA Approved
Advantages :
Saves costs of expensive replacement
Long electrical life
Reduces watt losses during “ON” condition, saves energy
High safety
No risk of dangerous voltage
Less maintenance and downtime
Standard control voltages: 24 V 50/60 Hz, 240 V 50/60 Hz, 415 V 50/60 Hz
Specification
Iskra Doo Part Number
KNL75-11-240VAC
Functions
3 Pole Contactor (3 x NO, with 1 x NO, 1 x NC Aux Contacts)
Nominal Voltage
230/400/500/690VAC @ 50/60Hz
Current Carrying Capacity as per UL
75 Amp Continuous @ 55 Deg C
Auxiliary Contacts
3 x NO, with 1 x NO, 1 x NC Aux Contacts (6 Amp) Optional NDL4-40, 4 Pole Snap On Aux Contacts
Trip Delay Time
2-10ms
Electrical Life
500,000 Ops
Operating Temperature
-25 to 55 Deg C
Mechanical Operations
10.000,000 Ops
Control Voltage
240VAC
Power Dissipation
6W per pole
Approvals
UL, CSA
Standards
IEC/EN 60947-4-1, AS/NZ 61009-1
Weight
950g
Enclosure Material
UL94
Factory Pack Qty
1
Datasheet
Product Datasheet
Contactor Catalogue
Iskra Contactor Catalogue
Iskra Doo KNL90-00-240VAC, AC Contactor 240/400/500/690V, 3 Pole 3 x NO, Nominal Current = 90 Amps, 240VAC Coil
Capacitor duty contactors are designed to meet the requirements of capacitor duty applications. Contactors are fitted with a block of three auxiliary contacts connected in series with six quick discharge damping resistors, two per each phase. Peak current is limited to the value within the contactor making capacity.
Features :
High contact reliability at low voltages
High electrical and mechanical endurance and high switching capacity
Four and Three-pole contactors
Optional auxiliary contacts
Ratings from 6 Amp to 1000 Amp
UL, CSA Approved
Advantages :
Saves costs of expensive replacement
Long electrical life
Reduces watt losses during “ON” condition, saves energy
High safety
No risk of dangerous voltage
Less maintenance and downtime
Standard control voltages: 24 V 50/60 Hz, 240 V 50/60 Hz, 415 V 50/60 Hz
Specification
Iskra Doo Part Number
KNL90-00-240VAC
Functions
3 Pole Contactor (3 x NO)
Nominal Voltage
230/400/500/690VAC @ 50/60Hz
Current Carrying Capacity as per UL
90 Amp Continuous @ 55 Deg C
Auxiliary Contacts
Optional BFX10-40, 4 Pole Snap On Aux Contacts
Trip Delay Time
2-10ms
Electrical Life
1,200,000 Ops
Operating Temperature
-25 to 55 Deg C
Mechanical Operations
15,000,000 Ops
Control Voltage
240VAC
Power Dissipation
9.4W per pole
Approvals
UL, CSA
Standards
IEC/EN 60947-4-1, AS/NZ 61009-1
Weight
1.25kg
Enclosure Material
UL94
Factory Pack Qty
1
Datasheet
Product Datasheet
Contactor Catalogue
Iskra Contactor Catalogue
WL-PROG-CBL, Wi-LEM Mesh Gate Programmaing Cable, Micro Male USB to USB Male
Mesh Gate 6424-L:
Stand-alone gateway which manages the wireless network and collects data periodically sent by the EMN, Wi-Zone and/or Wi-Pulse devices. The Mesh Gate 6424-L family is split into three options according to the number of end nodes allowed in the network.
Mesh Node-L:
Network repeater allowing extented distance between the EMN, WiZone and/or Wi-Pulse devices and the Mesh Gate. A Mesh network provides redundant data paths to the gateway.
Datasheet
Product Datasheet
Specification
Features
Mesh, Star and Star-Mesh Network topologies
Interface RS 232 Modbus RTU (Gateway only) 1) RF frequency range 2)
2405 .. 2480
802.15.4
MHz
Programmable in 16 channels
Channel spacing 5 MHz
Unlicensed ISM band worldwide
Range between Mesh Node-L and Mesh Gate 6424-L
(indoor, line of sight)
140
m
Range to EMN (indoor, line of sight)
30
m
Data rate
250
kbps
Power supply voltage AC adaptor (see page two)
6 to 30
V DC
RF output power
10 dBm (10mW)
General data
PC
Power comsumption
200
TA
Ambient operating temperature
- 10 .. + 55
TS
Storage temperature
- 25 .. + 85
m
Mass Mesh Gate 6424-L
60
Mesh Node-L 151 g
Rish Xmer Split Core 195/80 2500/5 Class 0.5 25VA, 85 x 172mm Aperture
Features
Quick Release Split Core System
Built In Sealable Terminal Covers
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Electronics Part Number
Rish Xmer Split Core 2500/5 195/80
Technology
Split Core AC Current Transformer
Ratio
2500/5
Aperture Size
172 x 85mm
VA Rating
25VA
Accuracy Class
Class 1
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-25°C / 40°C
Continuous Current (max)
Ipn x 1.2
Termination Style
Screw
Unit Weight
2kg
Factory Pack Qty
9
Datasheet
Product Datasheet
LEM LTC 1000-SF/SP14 Series Open Loop AC/DC Hall Effect Sensor
Features
Drop in replacement for LT 1000-SI/SP71 with 4 pin connection (Ground)
Bipolar and insulated current measurement up tp 3000 Amp
Current output
Bandwidth DC to 100kHz
Closed loop (compensated) current transducer
Panel mounting
Insulated plastic case recognized according to UL 94-V0
Advantages
Very good linearity
High accuracy
Low offset drift over temperature
Wide frequency bandwidth
Very low insertion losses
High immunity to external interference
Current overload capability
Low power consumption
Applications
Railway Equipment
Windmill Inverters
Test and Measurement
Substations
AC variable speed drives and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Application Domain
Industrial
Standards
EN 50178:1997
IEC61010-1:2010
UL 508:2010
Specification
LEM Part Number
LTC 1000-SF/SP14
Technology
Closed Loop Hall Effect
Aperture
ø42mm
ROHS
Yes
Supply Voltage
+/- 15 VDC to +/- 24 VDC Bipolar, Isolated
Load Current (RMS + DC)
1000 Amp
Measurement Range
+/- 3000 Amp
Output
250 mA
Isolation
13.4 kV
Bandwidth
DC-100 kHz
Mounting Style
Panel Mount (with Feet to match LT 1000-S/SP71)
Operating Temperature Range
-10°C / 85°C
Accuracy
0.4%
Termination Style
Faston 6.3 x 0.8mm
Unit Weight
900g
Factory Pack Quantity
6
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
Crydom 3F20-4, 3 Phase 4 Wire, 1 Stage EMC (RFI) Line Filter for Power Modules and SSR
Features
Line filter in standard and medical version
1-stage - standard attenuation between 150-250kHz
Characteristics
Designed for standard applications
Protection against interference voltage from the mains Possible interferences generated in the equipment are strongly attenuated
Universal line filter for standard applications
Suitable for use in equipment according to IEC/UL 60950
Other Versions on Request
Version with wire connection
Version with varistor for overvoltage protection
Spec
Sensata Part Number
3F20-4
Rated Voltage
475V rms
Rated Current
N/A
Filter Stages
1 Stage, 3 phase + N
Operating Temperature
-25°C to 100°C
Filter Type
Standard Attenuation
Leakage Current
0.45mA
Mounting
Panel Mount
Material
PolyCarbonate
Termination Style
Flying leads
Weight
80g
Factory Pack Qty
1
Protection Class
N/A
Isolation
N/A
VDE/UL/CSA/ROHS
Yes
Datasheet
Product Datasheet
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies