Fastron FSQF480D25, Solid State Relay, 3 Phase 4-32VDC Control, 25Amp, 24-530VAC Load, IP20
Ratings from 25 to 80 Amp @ 24-530 VAC
SCR output for heavy industrial loads
Zero voltage turn-on
IP20 Cover Integrated
AC & DC control types
Direct bond copper substrate
Direct power lead frame
Includes IP20 Cover
Specification
Trent Part Number
FSQF480D25
Switching Type
Zero Crossing
ROHS/CE
Yes
Control Voltage
4-32VDC
Load Current
25 Amp (rms) per Phase
Surge Capability
300 Amp (peak)
Special Feature
LED Status Indicator, with IP20 Cover
Mounting Style
Panel Mount
Load Voltage Range
24-530VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
385g
Factory Pack Qty
10
Datasheet
Product Datasheet
Equivalent Parts
Contact Us for Possible Replacement
Fastron Electronics BTCD/S-M-A2-DA, PID Controller 96x96mm, 85-265VAC, SSR output 2 Alarms, 4-20mA Cooling, Multirange TC/RTD/4-20mA Input
4-digit displays suit most industries including Temperature, Humidity, Pressure (0.5s response)
Drip-proof / Dust-proof IP56 (front panel only)
CE Approved
Each unit needs just 80 mm depth panel space
Optional Pattern Control Feature
Specification
Fastron Part Number
BTCD/S-M-A2-DA
Control Output
SSR 24VDC @ 30mA
Input
Multirange 4-20mA/RTD/Thermocouple (other linear inputs to be specified at time of order)
Option 1
2nd Alarm
Option 2
4-20mA Cooling
Mounting Style
96 x 96mm Panel Mount
Load Voltage Range
100-240VAC
Termination Style
Screw
Weight
600g
Factory Pack Qty
1
CE
Yes
Datasheet
BTC Series Brochure
BTC Series User Manual
BTC Series RS485 Comms Manual
Fine Tuning PID Adjustments
Fastron Electronics FESCT-055-150-5-IP65, 150Amp Measurement, 5 Amp Output Split Core CT's, Class 1, w/10M Flying leads, ø 55mm Aperture
Features
Quick Release Split Core System
10m Flying Leads
ø 55mm
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.60/3kV
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurement, 5 Amp Outputs
Specification
Fastron Electronics Part Number
FESCT-055-150-5-IP65
Technology
Split Core AC Current Transformer
Ratio
150/5A
Aperture Size
ø 55mm
VA Rating
2.5VA
Accuracy Class
Class 1
Output
5 Amp (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Dimensions
180x138x52mm
Mounting Style
Panel Mount
Operating Temperature Range
-35°C / 55°C
Continuous Current (max)
150Amp x 1.2
Termination Style
10M Twisted Pair 0.34mm^2
Unit Weight
2000g
Factory Pack Qty
9
Datasheet
Product Datasheet
Application Notes
Installation Guide
VX2-UMNA-A2D2, Temp Controller, 48x96mm, 100-240VAC, Multirange Input, Relay Output, 2 Alarms, 2 x SV
Multirange Input (Programmable)
4-digit displays suit most industries including Temperature, Humidity, Pressure (0.5s response)
Drip-proof / Dust-proof IP65 (front panel only)
UL/CE Approved
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 60 mm depth panel space
EC Compliant
Specification
Hanyoung Nux Part Number
VX2-UMNA-A2D2
Control Output 1 (Heat)
Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)
Control Output 2 (Cool)
N/A
Input
Multirange Type K/J/E/T/R/B/S/L/N/U/W/PLII/PT100/JPT100/4-20mA/0-20mA/1-5V/0-5V/0-10V/0-50mV/0-100mV. Note for Direct Current Input please use 250 Ohm Resistor in Parallel to the input terminals.
Alarm
Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)
Option 1
2nd Alarm Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)
Option 2
2 x SV Input (2 Setpoint Selection/External Setting Input)
Mounting Style
48 x 96mm Panel Mount
Supply Voltage
85 - 265VAC
Termination Style
Screw
Weight
350g
Factory Pack Qty
1
ROHS
Yes
UL
Yes
CE
Yes
Datasheet
VX Series Brochure
VX Series Instruction Manual
Free Software
Hanyoung Nux TCS Software
Hanyoung Nux TCS Software User Manual
VX Series SB Driver (Windows 7) Not required for Windows 10 or 11
Fastron FTPS-3-400-40-420, SCR Phase/Burst Controller, 400VAC 3 Wire (400V L-L, 230V L-N), 3 Phase, 4-20/0-20mA/5K POT Input, with In built Fuses, 32 Amps per Phase @ 50 Deg C
Features
Phase Angle, Distributed Burst, and Time Proportional Burst Control Functions
Made in China, Low cost
3 Phase, Phase Angle/Burst Controller
4-20mA Input Proportional Control (0-10V/1-5V/5K POT input on request)
Fully enclosed IP20
Phase Angle or Burst switching
Aluminium Frame
Removable Cover
Applications
Electrical Ovens, Kilns, or Furnaces
HVAC Heaters
Controlled Power Applications
Electric Boilers
Brewery Heating
Industrial Light Dimming
Suitable for HVAC or Industrial Environments
Specification
Fastron Part Number
FTPS-3-400-40-420
Rated Operating Temperature
50°C
SCR Configuration
3 Phase AC Switch
Control Voltage
4-20mA default (0-10V/0-5V/5K POT on request)
Load Current
32 Amps Per Phase @ 50 Deg C
Derating
2% per 1 Deg C (approx)
Control Range
0-100%
Alarms
1 x NO Relay Contact (not available with RS485 Option)
Comms
Optional RS485 Modbus RTU
Special Feature
Internal Fuse
Mounting Style
Panel Mount
Switching Voltage Range
400VAC +/-10%
Supply Voltage
230VAC +/-10%
Delay on Start
Programmable from 0 to 10 seconds
Soft Start
Programmable from 0 to 10 seconds
Termination Style
Screw
Unit Weight
4kg (6kg Packed)
Factory Pack Qty
1
Technical Docs
User Manual
Modbus Register Map
Calibration Procedure
Wiring Detail
VX4-USMA-A2, Temp Controller, 48x48mm, 100-240VAC, Multirange Input, SSR Output, Relay Cooling 2 Alarms
Multirange Input (Programmable)
4-digit displays suit most industries including Temperature, Humidity, Pressure (0.5s response)
Drip-proof / Dust-proof IP66 (front panel only)
UL/CE Approved
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 60 mm depth panel space
EC Compliant
Specification
Hanyoung Nux Part Number
VX4-USMA-A2
Control Output 1 (Heat)
SSR 12-15VDC @30mA
Control Output 2 (Cool)
Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)
Input
Multirange Type K/J/E/T/R/B/S/L/N/U/W/PLII/PT100/JPT100/4-20mA/0-20mA/1-5V/0-5V/0-10V/0-50mV/0-100mV. Note for Direct Current Input please use 250 Ohm Resistor in Parallel to the input terminals.
Alarm
Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)
Option 1
2nd Alarm Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)
Option 2
N/A
Mounting Style
48 x 48mm Panel Mount
Supply Voltage
85 - 265VAC
Termination Style
Screw
Weight
250g
Factory Pack Qty
1
ROHS
Yes
UL
Yes
CE
Yes
Datasheet
VX Series Brochure
VX Series Instruction Manual
Free Software
Hanyoung Nux TCS Software
Hanyoung Nux TCS Software User Manual
VX Series SB Driver (Windows 7) Not required for Windows 10 or 11
Fastron Electronics SCT-F50-500-5A, 5 Amp, 500Amp measurement Split Core CT's
Features
Quick Release Split Core System
Cable Mount
5 Amp Output
Self Powered
Rated System Voltage 0.60/3kV
0.9M Flying Leads
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
SCT-F50-500-5A
Technology
Split Core AC Current Transformer
Ratio
500/5 Amp
Aperture Size
ø 50 mm
VA Rating
N/A
Accuracy Class
Class 1
Output
5 Amp (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
500Amp x 1.2
Termination Style
0.9M Flying leads
Unit Weight
1000g
Factory Pack Qty
9
Datasheet
Product Datasheet
Stocked Split Core CT's Listing
Application Notes
Installation Guide
Types of Current Transformers - Blog
Cable Losses and CT's
High Accuracy or High Burden Requirements for CT's
Techsem MFC250-16-413F3D, Thyristor Diode Module, 250 Amp, 1200V
Features
Thyristor for line frequency
Pressure Contact Technology
Electrically insulated base plate
Industrial standard package
Long-term stability
3600V Isolation
50mm Base Width
Applications
Power Converter
Line rectifying 50/60 Hz
Deep Cycle Applications
Controlled Rectifiers
Softstart AC motor control
AC power control
Lighting and temperature control
Specification
Techsem Part Number
MFC250-16-413F3D
Vrrm
1600V
Diode Configuration
Thyristor Diode Module
IF(av) @ 85 Deg C
250 Amp
Package Size
W:50mm L:115mm D:52mm
Itsm
6.8 kA
VF(to)
0.85V
Tj(max)
125°C
rF
0.8mΩ
I(gt) @ 25 Deg C
180mA
Terminals
M8 Screw
Hole Centres
80mm x 38mm(M6)
Gate Terminals
Spade (A 2.8 - 0.8 DIN 46244)
R th(j-c)
0.12°C/W
R th(c-h)
0.04°C/W
Weight
800g
Mounting Torque
5 Nm (12 Nm Terminals)
Factory Pack Qty
8
Certification
UL Listed, ROHS
Techsem Headquarters
China
Datasheet
Product Datasheet
Alternatives
See MCD312-16io1 for Solder bonded alternative or TD330N12K , TD250N12KOF for pressure contact alternative
Eastron Europe SDM120CTModbus-MID-100mV, DIN Rail Mount kWh Meter, Single Phase, 240VAC aux, Class 1/Class B, 100mV CT Connect, w/ 2 x pulse outputs and RS485 Comms, MID Approved. *Best accuracy for low current measurements
100mV CT Connect
1 x Configurable Pule Output (via Modbus)
1 x Fixed Pulse Output (1000imp/kwh)
RS 485 communication up to 38,400 bit/s as standard
Optional Mbus Model available
True RMS values of currents and voltages
The meter is intended for measuring, and monitoring single-phase or electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power to the 30th Harmonic) from the measured signals.
Features :
Accuracy Class 1
Measurement of Active and Reactive Power
Modbus RTU communication up to 38,400 bit/s communication
Pulse output as standard
Graphic LCD with illumination
Specification
Eastron Europe Part Number
SDM120CTModbus-MID-100mV
Functions
Single Phase Energy Meter
Supply Voltage
230V L-N, 5 Amp +/-15% < 5VA
Nominal Measurement Range
230V L-L 230V L-N, 45 Amp
Maximum Measurement Range
276V L-L 230V L-N, 45 Amp
Nominal Current Input
100mV Amp CT
Pulse Output
1 x 1000imp/kwh, 1 x Configurable 60/100(default)/200ms
Primary CT Ratio
5,10,20,30,40,50,75,100,125,150,200,250,300,400,600 Amp
Accuracy
Class 1/ Class B (I,U,F,kW,kWh) Class 2 (Reactive)
Mounting
Din Rail
Real Time Clock
1min/month (30ppm)
Internal Memory
N/A
Dimensions
24mm x 100mm x 66mm (1 module wide)
Isolation
4kV
RS485
2400-38400 b/s
Weight
150g
Certification
EN 61010-1 Installation Category III
Factory Pack Qty
1
Enclosure Material
Noryl with fire protection to UL94-V-O. Self extinguishing
Enclosure Size
DIN 42880 6 Modules
Operating Temperature
-20 →+70 °C
Datasheet
Product Datasheet
User Manual
Modbus Protocol
Setup Video
Modbus Utility
EEM Meter Setting Software Utility
Fastron TTH-31-DB-3, Air Temperature Sensor and Transmitter, 190 x 18-19mm w/ 3M Cable, Can replace GEFRAN TRANSMICOR T211
4-20mA Output 2 Wire
Temp Measurement for 0 to 100 Deg C Max
190 x 18mm with 3M Cable
20 Second Response Time
12-30VDC Supply 150mA max
Pt100 Temp Sensing Elements
Specification
Fastron Part Number
TTH-31-DB-3
Sensor Type
RTD (Temperature) & Thin Film Capacitor (Humidity)
No of Wires
2
Shaft Length
190mm
Shaft Thickness
18-19mm
Approvals
CE, ROHS
Cable length
1 Meter
Temperature Range
0 to 100 Deg C
Mounting Style
Through Hole
Weight
45g
Factory Pack Qty
1
Datasheet
Datasheet
Installation Guide
Wiring Diagram