Gigavac G64B771, HV Relay, 50kVDC, 10A, SPST-NC, 12VDC Coil, 1,000,000 Cycles, 55kV Isolation, 72" Flying leads
Features
Hermetically Sealed (Patented) rated to 85 Deg C
High Efficiency DC Coils
Gas filled
Small and lightweight
Flexible package for installation
Specification
Gigavac Part Number
G64B771
Main Contact Type
SPST-NC
Auxiliary Contact Type
N/A
Coil Voltage
12VDC
Load Current
10 Amp
Mechanical Life @ 0 Amp
1,000,000 Operations
Nominal Load Voltage
50kV rms
Control Input Terminals
72" Flying Leads
Special Feature
N/A
Mounting Style
Panel Mount (M4)
Peak Voltage
55kVDC
Standards
UL508, NEC 690.11 and 690.12 DC
Termination Style
Screw
Unit Weight
335g
Factory Pack Qty
1
Datasheet
Product Datasheet
RTR Energia EA0525250500000 Power Factor Correction Capacitor, Single Phase, Dry Type 2.5 KVAR, 28.87uF, 525V, 50HZ, 60 x 150mm
Characteristics and utility
2.5 kVar @ 525V @ 50 Hz, 28.87uF.0kvar 10kvar
Discharge resistors Incorporated
Reactive power factor correction
Dry type
Connector type - single sided terminal
Indoor mounting
Safety
Overpressure disconnection system
Protection by internal fuses
Construction and materials
Low losses metallized self-healing polypropylene film, high density, high temperature and greater dielectric resistance Volt/µ
Polyurethane self-extinguishing resin V0, developed under standard UL 94 by RTR Energía
Aluminium case with bottom fixing M12x16
Standards
IEC 60831-1/2
EN 60831-1/2
Specification
RTR Energia Part Number
EA0525250500000
Technology
Dry Type, Low Loss, Self Healing
Dimensions
60 x 150mm
Standards
IEC 60831-1/2, EN 60831-1/2
Voltage
525V @ 50Hz
Kvar
2.5 Kvar
Capacitance
28.87uF
Tolerance On Capacitance
-5% + 10%
Current (In)
4.76 Amp
Overpressure Disconnection System
YES
Self Extinguishing Resin
YES
Internal Fuses
YES
DWCAP system (Patented) internal windings Displacement
YES
Mounting
M12 x 16mm (Indoor)
Operating Temperature Range
50°C Max, 30°C Mean(1 year), 40°C Mean(24 hrs)
Lifetime
120,000 Hours
Termination Style
Filter Type Terminal
Unit Weight
0.5kg
Factory Pack Quantity
25
Datasheet
Product Datasheet
Secure Meters DPM96V360-2, 96mm x 96mm LCD Digital Voltmeter, 3 Phase 0-500VAC Input, 0.5% Accuracy, 40 to 300VAC/DC Supply, IP54 (Optional IP65)
Features
LCD Dual Display
250mS Response Time
PC 94 UL V0
Each unit needs just 96 x 96mm Panel Space
52mm Depth
CE Approved
ROHS and REACH
Specification
Secure Part Number
DPM96V360-2
Frequency Range
45-65 Hz
Accuracy
0.5%
Input
100-500VAC
Over Range
x 1.5
Operating Temperature
0 - 60°C
Supply Voltage
40-300VAC/DC
Termination Style
Screw
Mounting Style
96 x 96mm Panel Mount
Case Material
PC - UL 94 V0
Standards
IP54 (IP65 Optional)
Protection Degree
IEC / EN 61010-1; IEC / EN 61010-2-0301
Weight
450g
Factory Pack Qty
1
Datasheet
Product Datasheet
Manual
DPM Series User Manual
Application Notes
Panel Meters Blog Articles
RTR Energia EA0525660500000 Power Factor Correction Capacitor, Single Phase, Dry Type 8.33 KVAR, 96.2uF, 525V, 50HZ, 85 x 225mm
Characteristics and utility
8.33 kVar @ 525V @ 50 Hz, 96.2uF
Discharge resistors Incorporated
Reactive power factor correction
Dry type
Connector type - single sided terminal
Indoor mounting
Safety
Overpressure disconnection system
Protection by internal fuses
Construction and materials
Low losses metallized self-healing polypropylene film, high density, high temperature and greater dielectric resistance Volt/µ
Polyurethane self-extinguishing resin V0, developed under standard UL 94 by RTR Energía
Aluminium case with bottom fixing M12x16
Standards
IEC 60831-1/2
EN 60831-1/2
Specification
RTR Energia Part Number
EA0525833050000
Technology
Dry Type, Low Loss, Self Healing
Dimensions
85 x 225mm
Standards
IEC 60831-1/2, EN 60831-1/2
Voltage
525V @ 50Hz
Kvar
8.33 Kvar
Capacitance
96.2uF
Tolerance On Capacitance
-5% + 10%
Current (In)
18.5 Amp
Overpressure Disconnection System
YES
Self Extinguishing Resin
YES
Internal Fuses
YES
DWCAP system (Patented) internal windings Displacement
YES
Mounting
M12 x 16mm (Indoor)
Operating Temperature Range
50°C Max, 30°C Mean(1 year), 40°C Mean(24 hrs)
Lifetime
120,000 Hours
Termination Style
Filter Type Terminal
Unit Weight
0.7kg
Factory Pack Quantity
25
Datasheet
Product Datasheet
Application Notes
Discharge Resistor Usage
Power Factor Correction Blog
Fastron Electronics HF121-12/0.4-50-7%K, 50kVar 400VAC(0.76mH) 7% Detuned Reactor for Power Factor Correction Capacitor Banks, 0.76mH(400VAC) 1.229mH(525VAC)
Specification
Technical Features
HF121-12/0.4-50-7%K
Electrical
Voltage
400V/525V
Network Frequency
50/60Hz
Inductance (mH) @ 400VAC
0.76mH
Inductance (mH) @ 525VAC
1.229mH
Nominal Power
50kvar
Value of p%
7% (189Hz)
Type of Conductor
Aluminium/Copper(optional)
Tolerance L
5%
Linearity (5% L)
1.8 x In
Isolation Voltage
kV
Maximum Room Temperature
-10 to 45 Deg C
Internal isolation
Class F(155°C), Class H (180°C Optional)
Maximum Overload
Permanent
1.17 x In
Temporary
2 x In
Safety
Protection Thermostat
Opens at 90 °C
Degree Protection
IP00
Installation
Indoor
Standards
EN-60289, IEC60076
Weight
38kg
Datasheet
Product Datasheet
Installation Guide
HF121 Series Installation Guide
RTR Energia EA0525417500000 Power Factor Correction Capacitor, Single Phase, Dry Type 4.17 KVAR, 525V, 38.46uF, 50HZ, 60 x 150mm
Characteristics and utility
4.17 kVar @ 525V @ 50 Hz, 48.16uF10.0, 38.46uFkvar 10kvar
Discharge resistors Incorporated
Reactive power factor correction
Dry type
Connector type - single sided terminal
Indoor mounting
Safety
Overpressure disconnection system
Protection by internal fuses
Construction and materials
Low losses metallized self-healing polypropylene film, high density, high temperature and greater dielectric resistance Volt/µ
Polyurethane self-extinguishing resin V0, developed under standard UL 94 by RTR Energía
Aluminium case with bottom fixing M12x16
Standards
IEC 60831-1/2
EN 60831-1/2
Specification
RTR Energia Part Number
EA0525417500000
Technology
Dry Type, Low Loss, Self Healing
Dimensions
60 x 150mm
Standards
IEC 60831-1/2, EN 60831-1/2
Voltage
525V @ 50Hz
Kvar
4.17 Kvar
Capacitance
48.164uF
Tolerance On Capacitance
-5% + 10%
Current (In)
7.94 Amp
Overpressure Disconnection System
YES
Self Extinguishing Resin
YES
Internal Fuses
YES
DWCAP system (Patented) internal windings Displacement
YES
Mounting
M12 x 16mm (Indoor)
Operating Temperature Range
50°C Max, 30°C Mean(1 year), 40°C Mean(24 hrs)
Lifetime
120,000 Hours
Termination Style
Filter Type Terminal
Unit Weight
0.5kg
Factory Pack Quantity
25
Datasheet
Product Datasheet
LEM DVL 750 Digital Voltage Transducer, Vpn = 750V, 50mA output, +/-15...24VDC powered, 8.5kV Isolation
Features
Bandwidth DC to 14kHz
Digital Transducer (ASIC based)
Closed loop transducer using Hall effect
Compact and versatile
Panel Mount
Insulated plastic case recognized according to UL 94-V0
Advantages
Very good linearity
High accuracy
Low temperature drift
Wide frequency bandwidth
Very low insertion losses
High immunity to external interference
Voltage overload capability
Low power consumption
Applications
Railway substation or locomotive
AC variable speed drives and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Water Treatment Electronics
Specification
LEM Part Number
DVL 750
Technology
Closed Loop Hall Effect
Aperture
No Aperture
ROHS
Yes
Supply Voltage
+/-15..24 VDC Bipolar, Isolated
Primary Nominal Voltage (RMS + DC)
+/- 750V
Measurement Range
+/- 1125V
Output
50 mA @Vpn
Isolation
8.5 kV
Bandwidth
DC-14 kHz
Mounting Style
Panel Mount
Operating Temperature Range
-40°C / 70°C
Accuracy
1%
Termination Style
M5 Screw
Unit Weight
270g
Factory Pack Quantity
4
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
RTR Energia EA0525083500000 Power Factor Correction Capacitor, Single Phase, Dry Type 0.835 KVAR, 9.59uF, 525V, 50HZ, 60 x 150mm
Characteristics and utility
0.835 kVar @ 525V @ 50 Hz, 9.59uF 10.0kvar 10kvar
Discharge resistors Incorporated
Reactive power factor correction
Dry type
Connector type - single sided terminal
Indoor mounting
Safety
Overpressure disconnection system
Protection by internal fuses
Construction and materials
Low losses metallized self-healing polypropylene film, high density, high temperature and greater dielectric resistance Volt/µ
Polyurethane self-extinguishing resin V0, developed under standard UL 94 by RTR Energía
Aluminium case with bottom fixing M12x16
Standards
IEC 60831-1/2
EN 60831-1/2
Specification
RTR Energia Part Number
EA0525083500000
Technology
Dry Type, Low Loss, Self Healing
Dimensions
60 x 150mm
Standards
IEC 60831-1/2, EN 60831-1/2
Voltage
525V @ 50Hz
Kvar
0.835 Kvar
Capacitance
9.59uF
Tolerance On Capacitance
-5% + 10%
Current (In)
1.58 Amp
Overpressure Disconnection System
YES
Self Extinguishing Resin
YES
Internal Fuses
YES
DWCAP system (Patented) internal windings Displacement
YES
Mounting
M12 x 16mm (Indoor)
Operating Temperature Range
50°C Max, 30°C Mean(1 year), 40°C Mean(24 hrs)
Lifetime
120,000 Hours
Termination Style
Filter Type Terminal
Unit Weight
0.5kg
Factory Pack Quantity
25
Datasheet
Product Datasheet
Application Notes
Discharge Resistor Usage
Power Factor Correction Blog
D44005050000000, Power Factor Correction Capacitor, 3 Phase, DWCAP 5KVAR 440V 50HZ, Dry Type, 70x230mm, 3 x 27.4uF
Characteristics and utility
5 kVar @ 440V @ 50 Hz 12.5.0kvar 12.5kvar
Three phase capacitor DUAL WINDING internally delta connected
Discharge resistors Incorporated
Reactive power factor correction
Dry type
Connector type - single sided terminal
Indoor mounting
True triple safety
Overpressure disconnection system
Protection by internal fuses
DWCAP system (patented) internal windings Displacement
Construction and materials
Low losses metallized self-healing polypropylene film, high density, high temperature and greater dielectric resistance Volt/µ
Polyurethane self-extinguishing resin V0, developed under standard UL 94 by RTR Energía
Aluminium case with bottom fixing M12x16
Standards
IEC 60831-1/2
EN 60831-1/2
Specification
RTR Energia Part Number
D44005050000000
Technology
Dry Type, Low Loss, Self Healing
Dimensions
70 x 230mm
Standards
IEC 60831-1/2, EN 60831-1/2
Voltage
440V @ 50Hz
Kvar
5.0 Kvar
Capacitance
3 x 27.4uF
Tolerance On Capacitance
-5% + 10%
Current (In)
12.03 Amp
Overpressure Disconnection System
YES
Self Extinguishing Resin
YES
Internal Fuses
YES
DWCAP system (Patented) internal windings Displacement
YES
Mounting
M12 x 16mm (Indoor)
Operating Temperature Range
50°C Max, 30°C Mean(1 year), 40°C Mean(24 hrs)
Lifetime
120,000 Hours
Termination Style
Filter Type Terminal
Unit Weight
1.5kg
Factory Pack Quantity
25
Datasheet
Product Datasheet
Application Notes
Discharge Resistor Usage
Power Factor Correction Blog
Voltage Derating Tables
RTR Energia EA0525660500000 Power Factor Correction Capacitor, Single Phase, Dry Type 6.60 KVAR, 525V, 50HZ, 60 x 200mm
Characteristics and utility
6.6 kVar @ 525V @ 50 Hz 10.0kvar 10kvar
Discharge resistors Incorporated
Reactive power factor correction
Dry type
Connector type - single sided terminal
Indoor mounting
Safety
Overpressure disconnection system
Protection by internal fuses
Construction and materials
Low losses metallized self-healing polypropylene film, high density, high temperature and greater dielectric resistance Volt/µ
Polyurethane self-extinguishing resin V0, developed under standard UL 94 by RTR Energía
Aluminium case with bottom fixing M12x16
Standards
IEC 60831-1/2
EN 60831-1/2
Specification
RTR Energia Part Number
EA0525660500000
Technology
Dry Type, Low Loss, Self Healing
Dimensions
60 x 200mm
Standards
IEC 60831-1/2, EN 60831-1/2
Voltage
525V @ 50Hz
Kvar
6.6 Kvar
Capacitance
231uF
Tolerance On Capacitance
-5% + 10%
Rating
38 Amp
Overpressure Disconnection System
YES
Self Extinguishing Resin
YES
Internal Fuses
YES
DWCAP system (Patented) internal windings Displacement
YES
Mounting
M12 x 16mm (Indoor)
Operating Temperature Range
50°C Max, 30°C Mean(1 year), 40°C Mean(24 hrs)
Lifetime
120,000 Hours
Termination Style
Filter Type Terminal
Unit Weight
0.5kg
Factory Pack Quantity
25
Datasheet
Product Datasheet
Application Notes
Discharge Resistor Usage
Power Factor Correction Blog
Gigavac GV241BAB, Contactor SPST-NO, 400+ AMP, 100-800VDC, 12VDC Coil, 38cm Flying leads, IP67, SPST-NO Aux Contact
Features
Hermetically Sealed
UL1604 for Class I & II Div 2 and Class III for use in hazardous locations
IP67 - Temporary water immersion (30 Min)
SAE J1171 External ignition protection
ISO8846 Protection against ignition around flammable gasses
CE Approved
High Efficiency Dual DC Coils - Very low 12,24,48VDC continuous coil power with no EMI emissions or cross-talk on your system control power
Ideal for battery powered systems or where low power is needed
PWM option provides additional drive control flexibility
Built in Coils suppression for all DC Coils
Flexible package for installation
Specification
Gigavac Part Number
GV241BAB
Main Contact Type
SPST-NO
Auxiliary Contact Type
SPST-NO
Coil Voltage
12VDC
Load Current
400+ Amp
Mechanical Life @ 0 Amp
1,000,000 Operations
Dielectric at Sea Level (leakage <1mA)
2.5kV rms
Control Input Terminals
38cm Flying Leads
Special Feature
N/A
Mounting Style
Panel Mount (M5)
Load Voltage Range
100 - 800VDC
Standards
CE, UL1604, IP67, SAEJ1171, UL508
Termination Style
M8
Unit Weight
450g
Factory Pack Qty
1
Datasheet
Product Datasheet
Fastron Electronics HF121-12/0.4-40-7%K, 40kVar 400VAC(0.95mH) 7% Detuned Reactor for Power Factor Correction Capacitor Banks, 0.95mH(400VAC) 1.526mH(525VAC)
Specification
Technical Features
HF121-12/0.4-40-7%K
Electrical
Voltage
400V/525V
Network Frequency
50/60Hz
Inductance (mH @ 400VAC)
0.95mH
Inductance (mH @ 525VAC)
1.526mH
Nominal Power
40kvar
Value of p%
7% (189Hz)
Type of Conductor
Aluminium/Copper(optional)
Tolerance L
5%
Linearity (5% L)
1.8 x In
Isolation Voltage
kV
Maximum Room Temperature
-10 to 45 Deg C
Internal isolation
Class F(155°C), Class H (180°C Optional)
Maximum Overload
Permanent
1.17 x In
Temporary
2 x In
Safety
Protection Thermostat
Opens at 90 °C
Degree Protection
IP00
Installation
Indoor
Standards
EN-60289, IEC60076
Weight
25kg
Datasheet
Product Datasheet
Installation Guide
HF121 Series Installation Guide