Fastron Electronics GAT-D-A Multirange Input/Output Signal Conditioner or Transmitter
Adjustable Zero and Span Setting
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space
Specification
Fastron Electronics Part Number
GAT-D-A
Control Output (Multirange)
0-5V,0-10V,0-10mA,0-20mA,4-20mA
Input (Mutirange)
0-50mV,0-5V,1-5V,0-10V,0-1mA,0-20mA,4-20mA
Over Range
x 1.5
Operating Temperature
0 - 60°C
Load Voltage
90 - 280VAC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
DIN Rail Mount
Case Material
PC - UL 94 V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
Fastron Electronics GTD-D-V4-D-1(GT-D-V4-C-1), Signal Isolator/Conditioner, 0-10VDC input, 22-60VAC/DC aux, 4-20mA output
Adjustable Zero and Span Setting
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space
Specification
Fastron Electronics Part Number
GTD-D-V4-D-1 (Formerly GT-D-V4-C-1)
Control Output
4-20mA
Input
0 - 10VDC
Over Range
x 1.5
Operating Temperature
0 - 60°C
Load Voltage
22 - 60VDC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
DIN Rail Mount
Case Material
PC - UL 94 V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
Fastron Electronics GT-DVO(0-75mV)D1, Signal Conditioner/Isolator/Voltage Transducer, 0-75mVDC input, 22-60VAC/DC aux, 4-20mA output
Program control, converter function are standard features
5-digit displays suit most industries including Temperature, Humidity, Pressure (0.5s response)
Drip-proof / Dust-proof IP66 (front panel only)
9-step pattern (for SV and time) is a standard feature
UL/CSA Approved
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 60 mm depth panel space
Specification
Fastron Electronics Part Number
GTD-DVO(0-75mV)D1
Control Output
4 - 20mA
Input
0 - 75mVDC
Over Range
x 1.5
Operating Temperature
0 - 60°C
Load Voltage
22 - 60VDC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
DIN Rail Mount
Case Material
PC - UL 94 V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
Fastron Electronics GT-P-P1-A-1, Signal Transmitter/Conditioner, 10K POT input, 4-20mA output, 100-240VAC/DC supply
Adjustable Zero and Span Setting
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space
Specification
Fastron Electronics Part Number
GTD-P-P1-A-1
Control Output
4-20mA
Input
10K Potentiometer
Over Range
N/A
Operating Temperature
0 - 60°C
Load Voltage
100 - 240VAC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
DIN Rail Mount
Case Material
PC - UL 94 V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
Fastron Electronics AMB-M-A8-A-N, 96 x 48mm AC Ammeter, True RMS, 0-5 Amp Input, 110-240VAC Aux supply, Large 4.1 Digit
Adjustable Zero and Span Setting
Adjustable Display Scaling
Large 4.1 Digit 20.3mm (8 Inch) LED Display
250mS Response Time
PC 94 UL V0
Each unit needs just 96 x 48mm Panel Space
90mm Depth
CE Approved
Specification
Fastron Electronics Part Number
AMB-M-A8-A-N
Conditioner Output
N/A
Input
0-5 Amp AC True RMS
Over Range
x 1.5
Operating Temperature
0 - 60°C
Supply Voltage
110 - 240VAC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Display Type
4.1 Digit RED LED
Termination Style
Screw
Mounting Style
96 x 48mm Panel Mount
Case Material
PC - UL 94 V0
Weight
320g
Factory Pack Qty
1
Datasheet
Product Datasheet NEW Version
Application Notes
Panel Meters Blog Articles
Vishay VSKD56/14, Dual Diode Module, 56 Amp, 1400V
Features
Thyristor for line frequency
Solder - Solder Bonded
Electrically insulated base plate
Industrial standard package
3600V Isolation
22mm Base Width
Applications
Power Converter
Line rectifying 50/60 Hz
Controlled Rectifiers
Soft start AC motor control
AC power control
Lighting and temperature control
Specification
Vishay Part Number
VSKD56/14
Vrrm
1400V
Diode Configuration
Dual Diode Module
IF(av) @ 112 Deg C
60 Amp
Package Size
W:22mm L:93mm D:30mm TO-240AA
Itsm
1.3 kA
VF(to)
0.86V
Tj(max)
150°C
rF
3.43mΩ
I(gt) @ 25 Deg C
N/A
Terminals
M5 Screw
Hole Centres
80mm (M6)
Gate Terminals
N/A
R th(j-c)
0.33°C/W
R th(c-h)
0.1°C/W
Weight
75g
Mounting Torque
4 Nm (3 Nm Terminals)
Factory Pack Qty
10
Certification
UL Listed, ROHS
Country of Origin
India
Datasheet
Product Datasheet
Alternatives
See DD89N14K or DD104N14K for Infineon Alternative
Vishay VSKT56/14, Dual Thyristor Module, 56 Amp, 1400V
Features
Thyristor for line frequency
Solder - Solder Bonded
Electrically insulated base plate
Industrial standard package
3600V Isolation
22mm Base Width
Applications
Power Converter
Line rectifying 50/60 Hz
Controlled Rectifiers
Softstart AC motor control
AC power control
Lighting and temperature control
Specification
Vishay Part Number
VSKT56/14
Vrrm
1400V
Diode Configuration
Dual Thyristor Module
IF(av) @ 85 Deg C
60 Amp
Package Size
W:22mm L:93mm D:30mm TO-240AA
Itsm
1.2 kA
VF(to)
1.02V
Tj(max)
125°C
rF
3.77mΩ
I(gt) @ 25 Deg C
150mA
Terminals
M5 Screw
Hole Centres
80mm (M6)
Gate Terminals
Faston A2.8 x 0.8mm
R th(j-c)
0.35°C/W
R th(c-h)
0.1°C/W
Weight
75g
Mounting Torque
4 Nm (3 Nm Terminals)
Factory Pack Qty
10
Certification
UL Listed, ROHS
Country of Origin
India
Datasheet
OLD Product Datasheet
2018 Product Datasheet
Alternatives
See TT61N12KOF, TT92N16K or TT104N14K for Infineon Pressure Contact Alternative, or MCC95-16 for IXYS solder bonded Alternative and TT60N16SOF for Infineon Solder Bonded Alternative
Vishay VSKH56/16, Thyristor Diode Module, 56 Amp, 1600V, 22mm Package
Features
Thyristor for line frequency
Solder - Solder Bonded
Electrically insulated base plate
Industrial standard package
3600V Isolation
22mm Base Width
Applications
Power Converter
Line rectifying 50/60 Hz
Controlled Rectifiers
Softstart AC motor control
AC power control
Lighting and temperature control
Specification
Vishay Part Number
VSKH56/16
Vrrm
1600V
Diode Configuration
Thyristor Diode Module
IF(av) @ 85 Deg C
60 Amp
Package Size
W:22mm L:93mm D:30mm TO-240AA
Itsm
1.2 kA
VF(to)
0.91V
Tj(max)
125°C
rF
4.27mΩ
I(gt) @ 25 Deg C
150mA
Terminals
M5 Screw
Hole Centres
80mm (M6)
Gate Terminals
Spade (A 2.8 - 0.8 DIN 46244)
R th(j-c)
0.22°C/W
R th(c-h)
0.1°C/W
Weight
75g
Mounting Torque
4 Nm (3 Nm Terminals)
Factory Pack Qty
10
Certification
UL Listed, ROHS
Country of Origin
India
Datasheet
OLD Product Datasheet
New Product Datasheet
Alternatives
See MCD95-16 for IXYS Solder Contact
See TD120N16SOF or TD122N22KOF Infineon Alternative
Iskra Doo MT440-SSUDAAMAA, Multifunction Power Transducer, Class 0.5, 4 Wire, 600V 1/5/10Amp AC Input 50/60Hz, 24-300VDC or 40-276VAC Aux Input, 3 Programmable Analogue Outputs, 1 relay output, RS485 + USB Comms
Class 0.5 (EN 60688)
USB Comms as standard
Up to 4 I/O Modules (analogue output, Multiple break point, non-linear characterstics
Automatic range of nominal current up to 12.5 A (Includes 5A/1A CT Input) and nominal voltage up to 600 V L-N
Adjustable tariff clock, display of electric energy consumption in optional currency
RMS values of currents and voltages
Measurements of active, reactive, apparent power and power factor
Measurements of energy in all 4 quadrants Average values of measurands per interval
Certified ship version available
The Power Transducer is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals.
Features :
Measurement of instantaneous values of more than 50 quantities (U, I, P, Q, S, PF, PA, f, f, MD, etc.).
Accuracy class 0.5
32 Adjustable Alarms
Input frequency 50/60 Hz or 400 Hz
RS 232/RS485 communication up to 115,200 bit/s (Optional) or USB communication as standard
MODBUS RTU communication protocol
Up to 4 inputs or outputs (pulse outputs, alarm outputs, tariff inputs)
Universal Supply 24-300VDC or 40-276VAC
Automatic range of nominal current up to 12.5 A and nominal voltage up to 600 V
User-friendly PC MiQen software
Specification
Iskra Doo Part Number
MT440-SSUSAAMAA
Functions
3 Phase Power Transducer
Supply Voltage
24-300VDC or 40-276VAC
Nominal Measurement Range
600V L-N, 1/5/10 Amp
Maximum Measurement Range
600V L-N, 12.5 Amp
Alarm
1 x Relay Output
Tariff Input
N/A
Output
3 x Analogue
Accuracy
Class 0.5 (I,U,F,PF,θ,THD) Class 1(Active), Class 2 (Reactive)
Battery Backup
N/A
Real Time Clock
1min/month (30ppm)
Isolation
3.5kV
Comms
USB (standard) RS485 2400-115200 b/s (RS232 Optional)
Weight
370g
Enclosure Material
UL94,
Factory Pack Qty
1
EU Directives
EN61010, EN60688,EN61326-1,60529,60068-2-1/-2/-6/-27/-30
Safety
Protection Class II
600V rms, installation category II
300V rms, installation category III
Pollution Degree 2 in compliance with SIST EN 61010-1:2002
Enclosure Material
PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0
Enclosure Protection
IP20
Shock Withstand
300g 8ms Pulse . 6 Shocks in each of 3 axes
Vibration Withstand
0.7g, 3...100Hz, 1oct/min 10 cycles in each of three axes
Operating Temperature
-20 →+70 °C
Datasheet
Product Datasheet
Software
MiQen Setting Software
MIPACK Programmer
Iskra Doo MC750 S SERNNT, Panel Mount Network Recorder 3 Phase, 4 Wire, Class 0.5, 50..500VAC 5Amp AC 50/60Hz AC 16-400Hz, 140 Parameter (U, I, P, Q, S, PF, PA, f, φ, THD, MD, energy, energy cost by tariffs...) 240VAC Aux Supply, RS232/RS485
Smart Meter
Automatic range of nominal current up to 12.5 A (Includes 5A/1A CT Input) and nominal voltage up to 750 V L-N 50/60Hz
Adjustable tariff clock, display of electric energy consumption in optional currency
Optional RS 232/RS 485 communication up to 115,200 bit/s or Ethernet communication
The meter is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals.
Features :
Measurement of instantaneous values of more than 140 quantities (U, I, P, Q, S, PF, PA, f, f, MD, energy, energy price by tariffs, etc.).
Accuracy class 0.5 or 0.2 (on demand)
Measurement of 40 minimal and maximal values in different time periods
Optional 32 adjustable alarms
Optional wide frequency range from 16 Hz to 400 Hz
Optional RS 232/RS 485 communication up to 115,200 bit/s or Ethernet communication
Optional MODBUS and DNP3 communication protocol
MMC memory card for setting and upgrading the meter
Up to 4 inputs or outputs (analogue outputs, pulse outputs, alarm outputs, tariff inputs)
Universal or AC power supply
Graphic LCD 128 x 64 dots with illumination
Automatic range of nominal current up to 5 A and nominal voltage up to 750 V
Adjustable tariff clock, display of electric energy consumption in optional currency
Multilingual support
User-friendly PC MiQen software
128 samples in one period
Measurement of THD on Current or Voltage from 0 to 400%
Specification
Iskra Doo Part Number
MC750 S SERNNT
Functions
Power Quality Meter, Energy Meter, Power Transducer, Network Recorder/Analyser
Supply Voltage
240VAC < 5VA
Nominal Measurement Range
500V L-N, 5 Amp 50/60Hz
Maximum Measurement Range
750V L-N, 12.5 Amp 50/60Hz
Alarm
N/A (Optional 4 Relays, 32 Alarms, 4 Groups)
Analogue Output
N/A (Optional 4 x 20mA)
Digital Input
N/A (Optional 4 x 230VAC/DC,75..130VAC/DC..5..48VAC/DC)
Pulse Output
N/A (Optional)
Pulse Input
N/A (Optional)
Bistable Switch/Latching Relay Alarm
N/A (Optional)
Status (Watchdog) Output
N/A (Optional)
Tariff Input
N/A (Optional 4 x 230VAC/DC,75..130VAC/DC..5..48VAC/DC)
Accuracy
Class 0.5 (I,U,F,PF,θ,THD) (Class 0.2 Optional) Class 1(Active), Class 2 (Reactive)
Battery Backup
Supercap
Real Time Clock
1min/month (30ppm)
Internal Memory
8MB
MMC
up to 512MB
Isolation
3.7kV
Ethernet
Optional (RJ45 10/100Mbit/s)
USB
Yes (2400-115200 b/s)
RS232/RS485
2400-115200 b/s
Weight
600g
Certification
UL, CSA, ROHS
Factory Pack Qty
1
EU Directives
Degree on electrical equipment designed for use within certain voltage limits URLRS 53/00 (Directive 73/23/EEC on low voltage): SIST EN 61010-1:2002
Safety Requirement for electrical equipment for measurement, control and laboratory use, part1 : general requirement
Decree on electromagnetic Compatibility (EMC) URLRS 61/00 (Directive 89/336/EEC on electromagnetic compatibility): SIST EN 61036 item 4.5: 1998 Meters for active energy (class 1 and 2)
Safety
Protection Class II
600V rms, installation category II
300V rms, installation category III
Pollution Degree 2 in compliance with SIST EN 61010-1:2002
Enclosure Material
PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0
Enclosure Protection
IP52 (IP00 for terminals) in compliance with SIST EN 60529:1997
Resistance to HF Interference
Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12
Conducted and radiated emissions
Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure)
Operating Temperature
-20 →+70 °C except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-22
Datasheet
Product Datasheet
User Manual
Schurter DFKF-18-0006 (DFKF2-18-4.0-.7), DFKF Compensated Choke
Features
Linear choke
THT-terminals
Inductor horizontally positioned in housing
Applications
Common Mode Attenuation
Smoothing RFI suppression choke
RFI suppression choke
Chopper amplifiers
DC drives and stepper motor controls
Switching power supplies
Specification
Schurter Part Number
DFKF-18-0006
Rated Voltage
440V
Rated Current
4A
Inductance
0.7mH
Operating Temperature
-25°C to 125°C
Resistance
16mΩ
Resonant Frequency
2.5MHz
Mounting
PCB Mount
Material
Thermoplastic, black, UL 94V-0
Termination Style
THT Terminals
Weight
5g
Factory Pack Qty
1
Climatic Category
40/125/21 acc. to IEC 60068-1
Isolation
1.8kV
VDE/UL/CSA/ROHS
Yes
Datasheet
Product Datasheet
Application Notes
Schurter 4304.5029 (FKID2-50-4/M80-A), IEC Appliance Inlet C14/M with 2-Stage EMC (RFI) Line Filter
Features
Panel Mount : Screw-on mounting from front side
4 Functions : Appliance Inlet Protection class I, EMC Filter 2 Stage High Attenuation, Line Switch 2-pole, Fuseholder for fuse-links 5 x 20 mm 2-pole
Line filter in standard and medical version
Quick connect terminals 6.3 x 0.8 mm
Characteristics
Compact design with optimal shielding
All single elements are already wired
Plug removal necessary for fuse-link replacement
2-stage line filter with increased attenuation
With EMC-shield
Suitable for use in equipment according to IEC/UL 60950
Suitable for use in medical equipment according to IEC/UL 60601-1
Medical Version
M80
Specification
Schurter Part Number
4304-5029 (FKID2-50-4/M80-A)
Rated Voltage
250V
Rated Current
4A
Filter Stages
2 Stage Higher Attenuation
Operating Temperature
-25°C to 85°C
Filter Type
Differential and Common Mode
Fuse Holder
2 Pole
Line Switch
2 Pole
Mounting
Panel Mount - Case 50
Material
Nickel Plated Steel
Termination Style
C14 Male to Quick Connects
Weight
260g
Factory Pack Qty
1
Protection Class
From front side IP 40 acc. to IEC 60529
Isolation
1.7kV
VDE/UL/CSA/ROHS
Yes
Datasheet
Product Datasheet