F921 DC Series Current Transducer, 100mA to 400 Amp Range with Adjustable High and Low Solid State Alarm
F921 Series DC Current Transducer with Process Outputs & High and Low Sold State Alarm Features Isolated measurement of DC currents using a Hall effect transducer with external aperture. Incorporates an integrated input level display and power supply. Wide measurement range available Choice of standard outputs Wide range isolated DC input supply DIN Rail mounting Signal Conditioned DC measurement output On board bar graph display User adjustable zero offset and span controls Zero insertion loss in current measurement path Earth leakage via differential Ipn for nominal Input ‘01’ Applications Process control Transportation Petrochemical Industrial Earth Leakage Energy Monitoring/Measurement Automation Delivery Delivery in 3-5 days for small qty. Otherwise 4-6 weeks Specification Oztherm Part Number F921-X-XX-DC-XX-XX Functions Single Phase AC Current Transducer Supply Voltage 9-36VDC Nominal Measurement Range 0-400 Amp (Sensor dependant) Maximum Measurement Range 2500 Amp with External Sensor Alarm C/O Relay 2Amp @ 40VDC, 2Amp @ 60VAC Response Time 250mS Accuracy @ 25 Deg C Class 1 Bandwidth DC - 1kHz linearity < 0.15% Isolation 2.5kV Comms N/A Weight 250g Enclosure Size 79 x 60 x 85mm Factory Pack Qty 1 EU Directives N/A Safety Protection Class II 600V rms, installation category II 300V rms, installation category III Pollution Degree 2 in compliance with SIST EN 61010-1:2002 Enclosure Material Polyamide non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP40 Shock Withstand 300g 8ms Pulse . 6 Shocks in each of 3 axes Vibration Withstand 0.7g, 3...100Hz, 1oct/min 10 cycles in each of three axes Operating Temperature -20 →+70 °C Datasheet Product Datasheet
$595.00
$702.10 inclGST -
F923 DC Series Current Transducer with Adjustable High and Low C/O Relay Alarm
F923 Series DC Current Transducer with Process Outputs & High and Low C/O Alarm Features Isolated measurement of DC currents using internal Hall effect transducer. Incorporates an integrated input level display and power supply. Wide measurement range available Choice of standard outputs Wide range isolated DC input supply DIN Rail mounting Signal Conditioned DC measurement output On board bar graph display User adjustable zero offset and span controls Zero insertion loss in current measurement path Earth leakage via differential Ipn for nominal Input ‘01’ Applications Process control Transportation Petrochemical Industrial Earth Leakage Energy Monitoring/Measurement Automation Delivery Delivery in 3-5 days for small qty. Otherwise 4-6 weeks Specification Oztherm Part Number F923-X-XX-DC-XX Functions Single Phase AC Current Transducer Supply Voltage 9-36VDC Nominal Measurement Range 0-8 Amp (Sensor dependant) Maximum Measurement Range 8 Amp Alarm C/O Relay 4Amp @ 30VDC, 0.5Amp @ 150VAC Response Time 250mS Accuracy @ 25 Deg C Class 1 Bandwidth DC - 1kHz linearity < 0.15% Isolation 2.5kV Comms N/A Weight 250g Enclosure Size 79 x 60 x 85mm Factory Pack Qty 1 EU Directives N/A Safety Protection Class II 600V rms, installation category II 300V rms, installation category III Pollution Degree 2 in compliance with SIST EN 61010-1:2002 Enclosure Material Polyamide non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP40 Shock Withstand 300g 8ms Pulse . 6 Shocks in each of 3 axes Vibration Withstand 0.7g, 3...100Hz, 1oct/min 10 cycles in each of three axes Operating Temperature -20 →+70 °C Datasheet Product Datasheet
$552.00 - $595.00
-
F923 AC Series Current Transducer with Adjustable High and Low Solid State Relay Alarm
F923 Series AC Current Transducer with Process Outputs & High and Low Sold State Alarm Features Isolated measurement of AC currents using internal Hall effect transducer. Incorporates an integrated input level display and power supply. Wide measurement range available Choice of standard outputs Wide range isolated DC input supply DIN Rail mounting Signal Conditioned AC measurement output On board bar graph display User adjustable zero offset and span controls Zero insertion loss in current measurement path Earth leakage via differential Ipn for nominal Input ‘01’ Applications Process control Transportation Petrochemical Industrial Earth Leakage Energy Monitoring/Measurement Automation Delivery Delivery in 3-5 days for small qty. Otherwise 4-6 weeks Specification Oztherm Part Number F923-X-XX-AC-XX Functions Single Phase AC Current Transducer Supply Voltage 9-36VDC Nominal Measurement Range 0-8 Amp (Sensor dependant) Maximum Measurement Range 8 Amp Alarm C/O Relay 2Amp @ 40VDC, 2Amp @ 60VAC Response Time 250mS Accuracy @ 25 Deg C Class 1 Bandwidth DC - 1kHz linearity < 0.15% Isolation 2.5kV Comms N/A Weight 250g Enclosure Size 79 x 60 x 85mm Factory Pack Qty 1 EU Directives N/A Safety Protection Class II 600V rms, installation category II 300V rms, installation category III Pollution Degree 2 in compliance with SIST EN 61010-1:2002 Enclosure Material Polyamide non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP40 Shock Withstand 300g 8ms Pulse . 6 Shocks in each of 3 axes Vibration Withstand 0.7g, 3...100Hz, 1oct/min 10 cycles in each of three axes Operating Temperature -20 →+70 °C Datasheet Product Datasheet
$552.00 - $595.00
-
HF121-12/0.4-50-7%K, 50kVar 400VAC(0.76mH) 7% Detuned Reactor for Power Factor Correction Capacitor Banks, 0.76mH(400VAC) 1.229mH(525VAC)
Heavy Item - No Free ShippingFastron Electronics HF121-12/0.4-50-7%K, 50kVar 400VAC(0.76mH) 7% Detuned Reactor for Power Factor Correction Capacitor Banks, 0.76mH(400VAC) 1.229mH(525VAC) Specification Technical Features HF121-12/0.4-50-7%K Electrical Voltage 400V/525V Network Frequency 50/60Hz Inductance (mH) @ 400VAC 0.76mH Inductance (mH) @ 525VAC 1.229mH Nominal Power 50kvar Value of p% 7% (189Hz) Type of Conductor Aluminium/Copper(optional) Tolerance L 5% Linearity (5% L) 1.8 x In Isolation Voltage kV Maximum Room Temperature -10 to 45 Deg C Internal isolation Class F(155°C), Class H (180°C Optional) Maximum Overload Permanent 1.17 x In Temporary 2 x In Safety Protection Thermostat Opens at 90 °C Degree Protection IP00 Installation Indoor Standards EN-60289, IEC60076 Weight 38kg Datasheet Product Datasheet Installation Guide HF121 Series Installation Guide
-
H31/110M-FCR, Heatsink 110mm, Milled, Drilled and Tapped for FCR Series 3 Phase Phase Control Module, 0.5°C/Watt
Free Aus Post Shipping for $300 SpendH31/110M-FCR, Heatsink 110mm, Milled, Drilled and Tapped for FCR Series 3 Phase Phase Control Module, 0.5°C/Watt Product Datasheet Heatsink products are mostly made to order and require 2-3 days more to produce.
-
HF121-12/0.4-40-14%K, 40kVar 400VAC 14% Detuned Reactor for Power Factor Correction Capacitor Banks, 1.92mH(400VAC) 3.071mH(525VAC)
Heavy Item - No Free ShippingFastron Electronics HF121-12/0.4-40-14%K, 40kVar 400VAC 14% Detuned Reactor for Power Factor Correction Capacitor Banks, 1.92mH(400VAC) 3.071mH(525VAC) Specification Technical Features HF121-12/0.4-40-14%K Electrical Voltage 400V System/525V Capacitor Network Frequency 50/60Hz Nominal Power 40kvar mH Rating 1.92mH(400VAC) 3.071mH(525VAC) Value of p% 14% (134 / 160Hz) Type of Conductor Aluminium/Copper(optional) Tolerance L 5% Linearity (5% L) 1.8 x In Isolation Voltage kV Maximum Room Temperature -10 to 45 Deg C Internal isolation Class F(155°C), Class H (180°C Optional) Maximum Overload Permanent 1.17 x In Temporary 2 x In Safety Protection Thermostat Opens at 90 °C Degree Protection IP00 Installation Indoor Standards EN-60289, IEC60076 Weight 38kg Datasheet Product Datasheet Installation Guide HF121 Series Installation Guide
-
ASUM-472M500EF1, 90x145mm Electrolytic Power Capacitor w/ Stud- 85 °C 15.000 hrs, Capacitance: 4700 uF Voltage: 500 VDC
Free Aus Post Shipping for $300 SpendASUM-472M500EF1 90x145mm Electrolytic Power Capacitor w/ Stud- 85 °C 15.000 hrs, 4700 uF, 500V Characteristics and utility 10,000uF 350V0.0kvar 20kvar Electrolytic Connector type - Stud inserts Indoor mounting Standards IEC 60831-1/2 EN 60831-1/2 Specification Itelcond Part Number ASUM-472M500EF1 Technology Electrolytic Dimensions ø90x145mm Mounting M12 Stud Standards IEC 60831-1/2, EN 60831-1/2 Voltage 500V Operating Temperature Range -40 to 85 °C Capacitance 14700uF Tolerance On Capacitance +10 / -20% Lifetime 10000 Hours @ 85 °C (Long Life) Termination Style M5 Inserts Unit Weight 1.85kg Factory Pack Quantity 50 Datasheet Product Datasheet
-
T6 Series Low Cost 3 Phase, 2 Leg SCR Burst Controller, 400VAC with In built Fuses, 32 Amps per Phase @ 50 Deg C
Fastron T6-2-4-75Z (60), 3 Phase, 2 Leg SCR Burst Controller, 400VAC with In built Fuses, 32 Amps per Phase @ 50 Deg C Features Phase Angle, Distributed Burst, and Time Proportional Burst Control Functions Made in China, Low cost 3 Phase, or Single Phase, Angle/Burst Controller 4-20mA/0-10V/1-5V/5K POT input Proportional Control RS485 Modbus RTU as standard 2 x Analogue Outputs as standard Limit POT input for output limitation C/O Alarm Contacts Start/Stop Run Feature Fully enclosed IP20 Phase Angle or Burst switching Aluminium Frame Removable Cover Applications Electrical Ovens, Kilns, or Furnaces HVAC Heaters Controlled Power Applications Electric Boilers Brewery Heatsing Industrial Light Dimming Suitable for HVAC or Industrial Environments Specification Fastron Part Number T6-2-4-75Z (60),ST6-2-4-40Z (32),T6-2-4-50Z (40) Rated Operating Temperature 50°C SCR Configuration 3 Phase, 2 Leg, AC Switch Control Voltage 4-20mA/0-10V/0-5V/5K POT Load Current 40 Amps Per Phase @ 50 Deg C Derating 2% per 1 Deg C (approx) Control Range 0-100% Alarms 1 x C/O Relay Contacts Special Feature Internal Fuse Analogue Output 2 x Programmable Outputs (3 Phase), 1 x Programmable Output (Single Phase) Comms RS485 Modbus RTU Mounting Style Panel Mount Switching Voltage Range 400VAC +/-10% Supply Voltage 230VAC +/-10% Soft Start/Stop Programmable Termination Style Screw Unit Weight 4kg (6kg Packed) Factory Pack Qty 1 Technical Docs User Manual
$695.00
$820.10 inclGST -
HF121-12/0.4-12.5-14%K, 12.5kVar 400VAC 14% Detuned Reactor for Power Factor Correction Capacitor Banks, 6.14mH(400VAC) 9.827mH(525VAC)
Heavy Item - No Free ShippingFastron Electronics HF121-12/0.4-12.5-14%K, 12.5kVar 400VAC 14% Detuned Reactor for Power Factor Correction Capacitor Banks, 6.14mH(400VAC) 9.827mH(525VAC) Specification Technical Features HF121-12/0.4-12.5-14%K Electrical Voltage 400V System/525V Capacitor Network Frequency 50/60Hz Nominal Power 12.5kvar Inductance 6.14mH(400VAC) 9.827mH(525VAC) Value of p% 14% (134 / 160Hz) Type of Conductor Aluminium/Copper(optional) Tolerance L 5% Linearity (5% L) 1.8 x In Isolation Voltage kV Maximum Room Temperature -10 to 45 Deg C Internal isolation Class F(155°C), Class H (180°C Optional) Maximum Overload Permanent 1.17 x In Temporary 2 x In Safety Protection Thermostat Opens at 90 °C Degree Protection IP00 Installation Indoor Standards EN-60289, IEC60076 Weight 21kg Datasheet Product Datasheet Installation Guide HF121 Series Installation Guide
-
HS122DR, Din Rail Mount Heatsink, 1.2 Deg C per Watt For 1 or 2 single phase Solid State Relay,
Free Aus Post Shipping for $300 SpendCrydom HS122DR, Din Rail Mount Heatsink for Solid State Relays, 1.2°C/W Features DIN Rail or Panel Mount heat sink types Suitable for SSR Mounting Pre drilled for 1 pr 2 single phase SSR Black anodised for professional look Spec Crydom Part Number HS122DR Mounting Type Din Rail Suitable SSR Rating 50 Amp Dimensions (without SSR) L:97mm x W:90mm x 86.5mm Thermal Impedance 1.2°C/W Load Current @ 40 Deg C 45 Amp Load Current @ 50 Deg C 37.5 Amp Unit Weight 437g Factory Pack Qty 10 Datasheet Product Datasheet App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies