Search results for "탤래@KOREATALK77~"
-
HF121-12/0.4-12.5-14%K, 12.5kVar 400VAC 14% Detuned Reactor for Power Factor Correction Capacitor Banks, 6.14mH(400VAC) 9.827mH(525VAC)
Heavy Item - No Free ShippingFastron Electronics HF121-12/0.4-12.5-14%K, 12.5kVar 400VAC 14% Detuned Reactor for Power Factor Correction Capacitor Banks, 6.14mH(400VAC) 9.827mH(525VAC) Specification Technical Features HF121-12/0.4-12.5-14%K Electrical Voltage 400V System/525V Capacitor Network Frequency 50/60Hz Nominal Power 12.5kvar Inductance 6.14mH(400VAC) 9.827mH(525VAC) Value of p% 14% (134 / 160Hz) Type of Conductor Aluminium/Copper(optional) Tolerance L 5% Linearity (5% L) 1.8 x In Isolation Voltage kV Maximum Room Temperature -10 to 45 Deg C Internal isolation Class F(155°C), Class H (180°C Optional) Maximum Overload Permanent 1.17 x In Temporary 2 x In Safety Protection Thermostat Opens at 90 °C Degree Protection IP00 Installation Indoor Standards EN-60289, IEC60076 Weight 21kg Datasheet Product Datasheet Installation Guide HF121 Series Installation Guide
-
KNK3053 50KVAR 525V 50HZ, Power Factor Correction Capacitor, 3 Phase, Dry Type 136x285mm, 3 x 192.48uF, Includes Discharge Resistor
Heavy Item - No Free ShippingIskra Doo KNK3053 50 KVAR 525V 50HZ, Power Factor Correction Capacitor, 3 Phase, Dry Type 136x285mm, 3 x 192.48uF Characteristics and utility 50kVar @ 525V @ 50 Hz 10.0kvar 10kvar Three phase capacitor DUAL WINDING internally delta connected Discharge resistors Incorporated Reactive power factor correction Dry type Connector type - Feed through terminals Indoor mounting Triple safety Overpressure disconnection system Protection by internal fuses Self Healing Construction and materials Low losses metallized self-healing polypropylene film, high density, high temperature and greater dielectric resistance Volt/µ UL 94 V0 Resin Aluminium case with bottom fixing M12x16 Standards IEC 60831-1/2 EN 60831-1/2 Specification Iskra Part Number KNK3053 50 KVAR 525V 50HZ Technology Dry Type, Low Loss, Self Healing Dimensions 136 x 285mm Standards IEC 60831-1/2, EN 60831-1/2 Voltage 525V @ 50Hz Kvar 50 Kvar Capacitance 3 x 192.48uF Tolerance On Capacitance -5% + 10% (others on request) Current (In) 36 Amp Overpressure Disconnection System YES Self Extinguishing Resin YES Internal Fuses YES Self Healing YES Mounting M12 x 16mm (Indoor) Operating Temperature Range 50°C Max, 30°C Mean(1 year), 40°C Mean(24 hrs) Lifetime 120,000 Hours Termination Style Filter Type Terminal Unit Weight 4.2kg Factory Pack Quantity 25 Datasheet Iskra PCF Catalogue Capacitor Datasheet Application Notes Discharge Resistor Usage Power Factor Correction Blog Voltage Derating Tables Hot Spot Testing 25kvar Specification Sheet 40kvar Specification Sheet
-
HF121-12/0.4-40-14%K, 40kVar 400VAC 14% Detuned Reactor for Power Factor Correction Capacitor Banks, 1.92mH(400VAC) 3.071mH(525VAC)
Heavy Item - No Free ShippingFastron Electronics HF121-12/0.4-40-14%K, 40kVar 400VAC 14% Detuned Reactor for Power Factor Correction Capacitor Banks, 1.92mH(400VAC) 3.071mH(525VAC) Specification Technical Features HF121-12/0.4-40-14%K Electrical Voltage 400V System/525V Capacitor Network Frequency 50/60Hz Nominal Power 40kvar mH Rating 1.92mH(400VAC) 3.071mH(525VAC) Value of p% 14% (134 / 160Hz) Type of Conductor Aluminium/Copper(optional) Tolerance L 5% Linearity (5% L) 1.8 x In Isolation Voltage kV Maximum Room Temperature -10 to 45 Deg C Internal isolation Class F(155°C), Class H (180°C Optional) Maximum Overload Permanent 1.17 x In Temporary 2 x In Safety Protection Thermostat Opens at 90 °C Degree Protection IP00 Installation Indoor Standards EN-60289, IEC60076 Weight 38kg Datasheet Product Datasheet Installation Guide HF121 Series Installation Guide
-
T6 Series Low Cost 3 Phase, 2 Leg SCR Burst Controller, 400VAC with In built Fuses, 32 Amps per Phase @ 50 Deg C
Fastron T6-2-4-75Z (60), 3 Phase, 2 Leg SCR Burst Controller, 400VAC with In built Fuses, 32 Amps per Phase @ 50 Deg C Features Phase Angle, Distributed Burst, and Time Proportional Burst Control Functions Made in China, Low cost 3 Phase, or Single Phase, Angle/Burst Controller 4-20mA/0-10V/1-5V/5K POT input Proportional Control RS485 Modbus RTU as standard 2 x Analogue Outputs as standard Limit POT input for output limitation C/O Alarm Contacts Start/Stop Run Feature Fully enclosed IP20 Phase Angle or Burst switching Aluminium Frame Removable Cover Applications Electrical Ovens, Kilns, or Furnaces HVAC Heaters Controlled Power Applications Electric Boilers Brewery Heatsing Industrial Light Dimming Suitable for HVAC or Industrial Environments Specification Fastron Part Number T6-2-4-75Z (60),ST6-2-4-40Z (32),T6-2-4-50Z (40) Rated Operating Temperature 50°C SCR Configuration 3 Phase, 2 Leg, AC Switch Control Voltage 4-20mA/0-10V/0-5V/5K POT Load Current 40 Amps Per Phase @ 50 Deg C Derating 2% per 1 Deg C (approx) Control Range 0-100% Alarms 1 x C/O Relay Contacts Special Feature Internal Fuse Analogue Output 2 x Programmable Outputs (3 Phase), 1 x Programmable Output (Single Phase) Comms RS485 Modbus RTU Mounting Style Panel Mount Switching Voltage Range 400VAC +/-10% Supply Voltage 230VAC +/-10% Soft Start/Stop Programmable Termination Style Screw Unit Weight 4kg (6kg Packed) Factory Pack Qty 1 Technical Docs User Manual
$695.00
$820.10 inclGST