Search results for "tg@tetherzon$*오다집수수료코인이체구입"
-
Sprint 350 3P4W 100 Amp RS232, Three Phase Revenue Grade Meter for Small Commercial Applications, 100 Amp Direct Connect, RS232 Comms, NMI NMI 14/2/84
Heavy Item - No Free ShippingSecure Sprint 350 3P4W 100 Amp RS232, Three Phase Revenue Grade Meter for Small Commercial Applications, 100 Amp Direct Connect, RS232 Comms, NMI NMI 14/2/84 Three Phase Revenue Grade Meter for small commercial applications Usage The meter is intended for measuring, monitoring three-phase electrical power network in residental, or small commercial applications for billing purposes. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals. Specification Secure Part Number Sprint 350 3P4W 100 Amp Functions Commercial Billing Meter with LCD Display Nominal Measurement/Supply Range 3 x 100/240/400VAC, 10/100 Amp 50Hz Maximum Measurement Range 460VAC, 10/100 Amp 50Hz 4 Quadrant Measurement Import/Export Tariff Input N/A Accuracy Class 1 Comms RS232 (Optional 4G available) Weight 2000g Certification CIEC/AS 62052-11, IEC/AS 62053-21, NMI M6-1 Factory Pack Qty 1 Safety IP53 Enclosure Material Engineering Plastic Optional RTC,Load Profile, RS485 Interface, Outputs Operating Temperature -40 →+80 °C Datasheet Datasheet IGC meters MT860 MT830/831 ICG Meter Shortform
-
6806U USB Battery Powered Dual Thermocouple Input Temperature Logger
Free Aus Post Shipping for $300 Spend6806U USB Battery Powered Dual Thermocouple Input Temperature Logger Features 12VDC Powered (powerpack included) Battery Powered USB Data download Dual Input Type K/J/T/E/R/S/N Thermocouples 128 real time samples 16 sets of dta logging, 1024 Data capacity T/C Offest Adjustment CE Approved Resolution 0.1 Deg C Accuracy better than 0.05 Deg C Datasheet Datasheet
-
M850-LDD, DC kWh Meter 96x96mm, 800VDC, 75mV Shunt Connected, RS485, Lockable,100-240VAC or 100-420VDC
Free Aus Post Shipping for $300 SpendHOBUT M850-LDD, DC kWh Meter 96x96mm, 800VDC, 75mV Shunt Connected, RS485, Lockable,100-240VAC or 100-420VDC 0-10 Amp direct connect, or 50,75mV Shunt Backlit LCD Lockable Optional RS485 communication up to 19,200 bit/s Universal Supply 100-440VAC, or 100-420VDC Accuracy class 1 The meter is intended for measuring, and monitoring DC electrical power networks. The meter records DC power according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands. Features : Measurement of DC kWh Power Optional Pulse Output Graphic LCD with illumination Specification HOBUT Part Number M850-LDD Functions DC Energy Meter Supply Voltage 100-440VAC, or 100-420VDC 0.5VA Nominal Measurement Range 15-150VDC or 30-300VDC, or 80-800VDC Maximum Measurement Range 15-800VDC Nominal Current Input 1A-10A or 50mV/75mV Shunt Infra Red Output N/A Tariff Input N/A (Optional) Accuracy Class 1 (I,U) Mounting Panle Mount Real Time Clock 1min/month (30ppm) Dimensions 96 x 96 x 82mm (2 DIN) Pulse Output Optional Isolation 4kV RS485 Optional Weight 500g Certification CE Factory Pack Qty 1 Safety Protection Class II 600V rms, installation category II 300V rms, installation category III Pollution Degree 2 in compliance with SIST EN 61010-1:2002 Enclosure Material PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP52 (IP00 for terminals) in compliance with SIST EN 60529:1997 Operating Temperature -20 →+60 °C Datasheet Product Datasheet
-
Rish Delta Energy-EA-Z-R, Panel Mount kWh Meter, 480VAC 3 Phase Class 1, 5A/1A seletcable CT secondary, 40-300VAC/DC Supply, RS485 Modbus RTU
Free Aus Post Shipping for $300 Spend96x96mm Panel Mount kWh Meter, 500V, 5A/1A seletcable CT secondary, 40-300VAC/DC Supply, RS485 Modbus RTU Optional Pulse Output Nominal current up to 1.2A/6 A (For 1/5A CT Input) and nominal voltage up to 290V L-N, 500V L-L Three Line Display RS 485 communication up to 19,200 bit/s RMS values of currents and voltages Measurements of active, reactive, apparent power and power factor Optional THD up to 15th Harmonic The meter is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals. Features : 96 x 96mm Panel Mount Accuracy class 1 Simple Menu Optional RS 232/RS 485 communication up to 19,200 bit/s or Ethernet communication MODBUS communication protocol 240V AC power supply Specification Northern Design Part Number Rish Delta Energy-EA-Z-R Functions kWh Meter, Energy Meter Supply Voltage 240VAC < 5VA Nominal Measurement Range 415V L-L 240V L-N, 5 Amp Maximum Measurement Range 415V L-L 280V L-N, 6 Amp Display Three Line LCD Pulse Output 2 (input or output) Accuracy Class 1 (kW,kWh) Class 1(Active) Class 2(kVar,PF) Battery Backup N/A Real Time Clock 1min/month (30ppm) Isolation 3.5kV Comms Modbus RTU Over TCP/IP 2400-19200 b/s Weight 350g Certification EN 61010-1 Installation Category III Factory Pack Qty 1 Environment IP54 Safety Protection Class II Enclosure Material Mablex with fire protection to UL94-V-O. Self extinguishing EnclosureSize 96 x 96mm x 83.5mm (72mm behind panel) Terminals Rising Cage 4mm² (12 AWG) cable max Humidity < 75% Non Condensing Operating Temperature -20 →+70 °C Datasheet Product Datasheet Lead time 3-4 weeks if not in stock
-
H-10-MOD-24, Split Core Bipolar Hall Effect DC Current Transducer, +/-10 Amp DC, RS485 Modbus RTU output, 31mm aperture, 24VDC supply
Free Aus Post Shipping for $300 SpendH-10-MOD-24, Split Core Bipolar Hall Effect DC Current Transducer, +/-10 Amp DC, RS485 Modbus RTU output, 31mm aperture, 24VDC supply Compact and versatile Split Core Bipolar DC current sensor, +/-10 Amp DC, Modbus RS485output Features Modbus RTU (RS485)output ⌀31mm Aperture Split Core DC Measurement Busbar, or DIN Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Mount Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number H-10-MOD-24 Technology DC Hall Effect Current Transducer with Processoutput ROHS Yes Supply Voltage 24VDC Nominal Current (DC) 0-10 Amp Response Time < 200mS Output RS485 Modbus RTU Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Screw Unit Weight 200g Factory Pack Qty 6 Datasheet Product Datasheet
-
FP010030P/1A, 100/1 Amp Split Core CT, Class 1, 1VA Clip On AC Current Transformer, 20 x 30mm Aperture, Dimension 90 x 40 x 110mm
FP010030P/1A, 100/1 Amp Split Core CT, Class 1, 1VA Clip On AC Current Transformer, 20 x 30mm Aperture, Dimension 90 x 40 x 110mm Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number FP010030P/1A Technology Split Core AC Clip On Current Transformer Ratio 100/1 Aperture Size 20 x 30mm VA Rating 1VA Accuracy Class Class 1 Output 1 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -10°C / 50°C Continuous Current (max) 100Amp x 1.2 Termination Style Screw Approvals CE Unit Weight 1150g Factory Pack Qty 1 Datasheet Product Datasheet Installation Guide
$92.00
$108.56 inclGST -
H-500-MOD-24, Split Core Bipolar Hall Effect DC Current Transducer, +/-500 Amp DC, RS485 Modbus RTU output, 31mm aperture, 24VDC supply
Free Aus Post Shipping for $300 SpendH-500-MOD-24, Split Core Bipolar Hall Effect DC Current Transducer, +/-500 Amp DC, RS485 Modbus RTU output, 31mm aperture, 24VDC supply Compact and versatile Split Core Bipolar DC current sensor, +/-500 Amp DC, Modbus RS485output Features Modbus RTU (RS485)output ⌀31mm Aperture Split Core DC Measurement Busbar, or DIN Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Mount Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number H-500-MOD-24 Technology DC Hall Effect Current Transducer with Processoutput ROHS Yes Supply Voltage 24VDC Nominal Current (DC) 0-500 Amp Response Time < 200mS Output RS485 Modbus RTU Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Screw Unit Weight 200g Factory Pack Qty 6 Datasheet Product Datasheet
-
DC-0-300-420-1.0, Hall Effect DC Current Transducer, 0-300 Amp DC, 4-20mA Unipolar output, 24VDC supply
DC-0-300-420-1.0, Hall Effect DC Current Transducer, 0-300 Amp DC, 4-20mA Unipolar output, 24VDC supply Compact and versatile Split Core DC current sensor, 0-300 Amp DC, 4-20 mA Unipolar Output Other measurement ranges available on request Features ⌀20mm Aperture DC Unipolar Measurement 4-20mA analogue output Busbar, or DIN Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number DC-0-300-420-1.0 Technology DC Hall Current Sensor with Process Output ROHS Yes Supply Voltage 24VDC Nominal Current (DC) 0-300 Amp Response Time < 1uS Output Unipolar 4-20mA Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Terminals Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet
$385.00
$454.30 inclGST -
FTA-005-420B-24, DC Current Transducer, +/-5 Amp , 4-20mA Bipolar Output, 24VDC supply, 21mm Aperture
FTA-005-420B-24, DC Current Transducer, +/-5 Amp , 4-20mA Bipolar Output, 24VDC supply, 21mm Aperture Compact and versatile Split Core DC current sensor, +/-5 Amp , 4-20mA Bipolar Output Features ⌀21mm Aperture DC Bipolar Measurement 4-20mA Instantaneous output 120mS Response (for 0- +/-10mA ~+/-10A AC) 10uS Response (0-+/-5A ~+/-100A AC) Panel mount Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number FTA-005-420B-24 Technology DC Current Transducer with Instant Output Yes Supply Voltage 24VDC Nominal Current (RMS + DC) +/-5 Amp Response Time < 120mS Output Bipolar 4-20mA Instant Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Aperture 20mm Mounting Style Panel Mount Operating Temperature Range -10°C / 85°C Accuracy 1% Termination Style 4 Pin Plug (Included) Unit Weight 300g Factory Pack Qty 6 Datasheet Product Datasheet
$285.00
$336.30 inclGST -
H-100-MOD-24, Split Core Bipolar Hall Effect DC Current Transducer, +/-100 Amp DC, RS485 Modbus RTU output, 31mm aperture, 24VDC supply
Free Aus Post Shipping for $300 SpendH-100-MOD-24, Split Core Bipolar Hall Effect DC Current Transducer, +/-100 Amp DC, RS485 Modbus RTU output, 31mm aperture, 24VDC supply Compact and versatile Split Core Bipolar DC current sensor, +/-100 Amp DC, Modbus RS485output Features Modbus RTU (RS485)output ⌀31mm Aperture Split Core DC Measurement Busbar, or DIN Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Mount Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number H-100-MOD-24 Technology DC Hall Effect Current Transducer with Processoutput ROHS Yes Supply Voltage 24VDC Nominal Current (DC) 0-100 Amp Response Time < 200mS Output RS485 Modbus RTU Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Screw Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet
-
FTCK-5-EGTD-3000-1/8N Vehicle Exhaust Sensor, Type K MIMS Class B, 1/8" NPT SS304 80mm x 50mm x 4.8mm Probe w/ 3000mm Screened Teflon/Braided SS cable, -20 to 600 Deg C
Free Aus Post Shipping for $300 SpendFastron FTCK-5-EGTD-3000-1/8N Vehicle Exhaust Sensor, Type K MIMS Class B, 1/8" NPT SS304 80mm x 50mm x 4.8mm Probe w/ 3000mm Screened Teflon/Braided SS cable, -20 to 600 Deg C 1/8" NPT Compression Fitting SS304 Durability Class A Accuracy Teflon SS Braided Cable Low Long Term Drift Rated for -20 to 600 Deg C Max 80mm x 50mm x 4.8mm MIMS Specification Fastron Part Number FTCK-5-EGTD-3000-1/8N Sensor Type Type K Thermocouple No of Wires 2 Probe Length 80 x 50mm Sheath Thickness 4.8mm Sheath Material SS304 Accuracy Class A Approvals N/A Cable length 3 Meters Cable Type Teflon/Braided Stainless Steel with Spring Bayonet Cap Temperature Range -20 to 600 Deg C Special Feature Quick Release Fitting, Strain Relief Spring Cable Mounting Style Quick Release Fitting Weight 300g Factory Pack Qty 1 Datasheet Datasheet
-
DVL 250 UI, Digital Voltage Transducer 250V Input, 4-20mA output, +/- 15V…24VDC, 8.5kV Isolation
LEM DVL 250 UI, Digital Voltage Transducer 250V Input, 4-20mA output, +/- 15V…24VDC, 8.5kV Isolation Features Bandwidth DC to 14kHz Multi Range through pin selection Closed loop transducer using Hall effect Compact and versatile Panel Mount Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications Railway substation or locomotive AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number DVL 250 UI Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15..24 VDC Bipolar, Isolated Primary Nominal Voltage (RMS + DC) +/- 250V Measurement Range +/- 375V Output 4 - 20mA Isolation 8.5 kV Bandwidth DC-14 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 70°C Accuracy 1% Termination Style M5 Screw Unit Weight 270g Factory Pack Quantity 4 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
$661.00
$779.98 inclGST