H71 Heatsink Profile 50mm x 80mm, Various Lengths cut to order, Milled or Raw Finish 1.76 Deg /W @ 100mm
Datasheet
Product Datasheet
Heatsink Data
New Heatsink Data Book
Old Heatsink databook with additional thermal data
Welding Diode Stack Bridge 350 Amp, Single Phase, 200 x 125mm Approx
Fastron Electronics Part Number
WST0012
Nominal Current
350
Peak Current
600
Leakage Current
<6.5mA
Forward Voltage
<1.35V
Rated Voltage
150VDC
Temperature Rise
<65°C
Mounting Torque
>12.5 N.M
Required Air Speed
3 m/s
Datasheet
Product Datasheet
LEM TOP 90-S10/SP4, AC Current Transformer, 90 Amp 0-90mA rms output, X = 1%
Features
90 Amp AC Current Measurement
Signal Conditioned output
Split Core
0-90mA Instantaneous
Cable or Din Rail Mounting
Self Powered
Isolated plastic case recognised according to UL94-V0
UL508 Rated
Advantages
Large aperture for cable up to ? 10mm
High isolation between primary and secondary circuits
Easy installation
Applications
Hybrid Inverter
UPS
Power Metering
Power Quality Analysis
Distributed Measurement Systems
Current Measurement
Energy Management
Motor Control
Condition Monitoring
Specification
LEM Part Number
TOP 90-S10/SP4
Technology
AC Current Transformer
Protection Class
IP50
Supply Voltage
Self Powered
Load Current (RMS)
125 Amp
Output
0-90mA rms
Isolation
4.3kV (AC, 50Hz, 1 min)
Bandwidth
50 - 60Hz
Mounting Style
Din Rail Mount or Cable Mount
Operating Temperature Range
-25°C / 70°C (for 100°C Conductors)
Accuracy
1.5%
Termination Style
1M Output Cable
Unit Weight
150g
Factory Pack Qty
6
Datasheet
Product Datasheet
Alterantive
Fastron OEM Alternative
Fastron Electronics SCT-F24-200-5A, 200/5 Amp Class 1 Series Current Transformer
Features
Quick Release Split Core System
Cable Mount
5 Amp Output
Self Powered
Rated System Voltage 0.60/3kV
0.9M Flying Leads
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
SCT-F24-200-5A
Technology
Split Core AC Current Transformer
Ratio
200/5 Amp
Aperture Size
ø 24 mm
VA Rating
N/A
Accuracy Class
Class 1
Output
5 Amp (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
200Amp x 1.2
Termination Style
0.9M Flying leads
Unit Weight
100g
Factory Pack Qty
9
Datasheet
Product Datasheet
Application Notes
Installation Guide
Fastron Electronics FESCT-32-500-0.333V, 500Amp measurement Split Core Current Transformer, w/1M Flying leads, 32x32mm Aperture, Class 1
Features
Quick Release Split Core System
1m Flying Leads
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.60/3kV
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Electronics Part Number
FESCT-32-500-0.333V
Technology
Split Core AC Current Transformer
Ratio
500/0.333V
Aperture Size
32 x 32mm
VA Rating
N/A
Accuracy Class
Class 1
Output
0.333VAC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 55°C
Continuous Current (max)
500Amp x 1.2
Termination Style
1M Twisted Pair 0.34mm^2
Unit Weight
350g
Factory Pack Qty
9
Datasheet
Product Datasheet
Application Notes
Installation Guide
Trent 250EU-S-500V-120kA, 250EU-S-500V-120kA Series 500V Semiconductor I²t Fuse NH1 Style
Features
Square Body DIN 43 653
Wide Range of I²t
Ratings up to 2000 Amp
Fuse Holder Mounted
IEC Standard 60269.1 AND 4
500 V Voltage Rating complying with IEC 33
Applications
Protection of High Powered Semiconductors according to I²t
Short Circuit Protection
DC or AC Motor I²t Protection
Battery Fuse
Specification
Trent Part Number
250EU-S-500V-120kA
Fuse Type
I²t AR Class HRC
Nominal Voltage
500VAC @ 50Hz
I²t Rating (660V)
Nominal Current (RMS + DC)
250 Amp
Tested Breaking Capacity
120kA @ 690VAC
Dimensions
135 x 65 x 52mm (NH1)
Indicator
Tag
Mounting Style
Fuse Holder
Operating Temperature Range
-40°C / 125°C
Watts Dissipation
90WW
Termination Style
NH1 Fuse Holder
Unit Weight
400g
Factory Pack Qty
3
Datasheet
Product Datasheet
Rishabh CT 75/5 Class 1 2.5VA 45/21(40) Current Transformer
Features
DIN Rail Mounting Clip Included
Built In Sealable Terminal Covers
Mounting Feet Supplied
Narrow Width (45mm)
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Rishabh Part Number
CT 75/5 Class 1 2.5VA 45/21 (40)
Technology
AC Current Transformer
Ratio
75/5
Aperture Size
⌀ 21mm or 20x10mm Busbar
VA Rating
2.5VA
Accuracy Class
Class 1
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Din Rail Mount
Operating Temperature Range
-30°C / 85°C
Continuous Current (max)
200Amp x 1.2
Termination Style
Screw
Unit Weight
300g
Factory Pack Qty
9
Datasheet
Product Datasheet
Powersem PSD125/16 Three Phase Diode Rectifier Bridge, Replaces Semikron SKD110/16
Features
Package with DCB ceramic base plate
Isolation voltage 3000 V∼
Planar glass passivated chips
Low forward voltage drop
Leads suitable for PC board soldering
UL registered, E 148688
Applications
Heat and temperature control for industrial furnaces and chemical processes
Lighting control
Motor control
Power converter
Advantages
Easy to mount with two screws
Space and weight savings
Improved temperature and power cycling capability
High power density
Specification
Powersem Part Number
PSD125/16
AC Line voltage
533V
Device Configuration
Three Phase Diode Rectifier Bridge
DC Output @ 85 Deg C
166 Amp
Package Size
W:69mm L:50mm D:31mm
Itsm
1800 A
VF(to)
0.8V
Tj(max)
150°C
rF
3mΩ
Terminals
M5 (1.5Nm)
Hole Centres
60mm (M5)
Gate Terminals
M3 (5Nm)
R th(j-c)
0.83°C/W
R th(c-h)
0.3°C/W
Weight
225g
Isolation
3kV
Factory Pack Qty
10
Certification
UL Listed
Powersem Headquarters
Germany
Datasheet
Product Datasheet
Alternatives
See PSD162/16 for higher rated equivalent
Schurter DKIH-3242-16D9 Choke
Features
Current compensated choke
1-phase choke
THT-terminals
Flange for mounting onto printed circuit board
Compact size and light weight
Open design for optimal cooling
Nanocrystalline or ferrite ring cores
Customer specific pin outs available
Applications
Frequency converter
Charge stations
UPS-systems
Switching power supplies
Specification
Schurter Part Number
DKIH-3242-16D9
Rated Voltage
300VAC (UL,IEC), 425VDC max
Rated Current
16A
Inductance
2 x 0.9mH -30%, +50%
Operating Temperature
-25°C to 125°C
Resistance (Rcu)
5.6mΩ
Resonant Frequency
0-400 Hz
Mounting
THT PCB Mount
Material
Thermoplastic, black, UL 94V-0
Termination Style
THT Terminals
Weight
50g
Factory Pack Qty
1
Climatic Category
40/125/21 acc. to IEC 60068-1
Isolation
2.5kV
VDE/UL/CSA/ROHS
Yes
Datasheet
Product Datasheet
Application Notes
Crydom CKRD6030, Solid State Relay, Single Phase 3.5 - 32VDC Control, 30A, 48-660VAC Load, Din Rail
Features
Ratings from 10A to 30 Amp @ 48-530 VAC
SCR output for heavy industrial loads
Zero voltage or instantaneous turn-on outputs
UL/CSA/VDE Approved, CE Compliant to EN60950-1
Improved SEMS screw and washer
Redesigned housing with anti-rotation barriers
AC & DC control types
Direct bond copper substrate
EMC compliant to Level 3
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
CKRD6030
Switching Type
Zero Crossing
ROHS
Yes (Details)
Control Voltage
4 - 32VDC
Load Current
30 Amp (rms) @ 25 Deg C Ambient, 25.5 Amp (rms) @ 40 Deg C Ambient
Surge Capability
1200 Amp (peak)
Special Feature
None
Mounting Style
DIN Rail Mount
Load Voltage Range
48 - 660VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
280g
Factory Pack Qty
20
Datasheet
Product Datasheet
Alternatives
Contactor Style DR2260D35V
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Crydom CWD2410, Solid State Relay, Single Phase 3-32VDC Control, 10A, 24-280VAC Load. High surge w/LED Indicator
Ratings from 25A to 125 Amp @ 24-280VAC
SCR output for heavy industrial loads
Zero voltage or instantaneous turn-on outputs
UL/CSA/VDE Approved, CE Compliant to EN60950-1
Improved SEMS screw and washer
Redesigned housing with anti-rotation barriers
AC & DC control types
Direct bond copper substrate
EMC compliant to Level 3
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
CWD2410
Switching Type
Zero Crossing
ROHS
Yes (Details)
Control Voltage
4-32VDC
Load Current
10 Amp (rms)
Surge Capability
400 Amp (peak)
Special Feature
LED Status Indicator, High Surge
Mounting Style
Panel Mount
Load Voltage Range
24-280VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
75g
Factory Pack Qty
20
Datasheet
Product Datasheet
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Equivalent Parts
CWD2450P for stocked equivalent
Fastron Electronics FESCT-19-300-0.333V, 300Amp measurement Split Core CT's, w/1M Flying leads, 19x19mm Aperture, 0.333v Class 1 Series Current Transformer
Features
Quick Release Split Core System
1m Flying Leads
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.60/3kV
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
FESSCT-19-300-0.333V
Technology
Split Core AC Current Transformer
Ratio
300/0.333V
Aperture Size
19 x 19mm
VA Rating
N/A
Accuracy Class
Class 1
Output
0.333VAC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 55°C
Continuous Current (max)
300Amp x 1.2
Termination Style
1M Twisted Pair 0.34mm^2
Unit Weight
350g
Factory Pack Qty
9
Datasheet
Product Datasheet
Application Notes