Risbabh EM94-Z-V1-H-D, Panel Mount DC kWh Meter, Class 0.5, 50-150mV Shunt input, 60-300VDC, 2 Alarm/Pulse Outputs, RS485 & USB Comms, Single Line LCD Display, 60-300VAC/DC Aux Supply, Internal Logging
2 Pulse/Alarm Outputs
50-150mV Shunt Input, and nominal voltage 60-300VDC
RS 485 communication up to 57,600 bit/s
USB Port
8MB Internal Storage
DC Measurement Only
The meter is intended for measuring, analysing and monitoring DC Power. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current,, energy, power.) from the measured signals.
Features :
96 x 96mm Panel Mount
Accuracy class 0.5
Simple Menu
RS 485 communication up to 57,600 bit/s
USB Comms
8MB Internal Logger
60-300VAC/DC power supply
Specification
Rishabh Part Number
EM94-Z-V1-H-D
Functions
kWh Meter, Energy Meter
Supply Voltage
60-300VAC/DC
Nominal Measurement Range
60-300VDC
Maximum Measurement Range
60-300VDC
Display
Single Line LCD
Pulse/Relay Output
2
Accuracy
Class 0.5 (Energy)
USB
YES
Real Time Clock
1min/month (30ppm)
Isolation
3.5kV
RS485 Modbus RTU
YES 57,600bps
Weight
450g
Certification
EN 61010-1 Installation Category III
Factory Pack Qty
1
Environment
IP54
Safety
Protection Class II
Enclosure Material
Mablex with fire protection to UL94-V-O. Self extinguishing
EnclosureSize
96 x 96mm x 83.5mm (72mm behind panel)
Terminals
Rising Cage 4mm² (12 AWG) cable max
Humidity
< 75% Non Condensing
Operating Temperature
-20 →+70 °C
Datasheet
Product Datasheet
Software
Software User Manual
Software Download Link
Application Notes
1)Reading Data from Registers -> Download file
2)Maximum Memory Size -> Read below
Max Available Memory Locations in 8MB Size = 273030
Actual parameter stored in Each log (Memory locations used) = Date +time+Number of parameter selected by user
Considering your example for 2 parameters:
Number of parameter selected by user = 2 (kwh & kVA)
Actual parameter stored in Each log = 1(Date) +1(time)+ 2 (Parameters) = 4 (memory locations used per log)
Maximum log that can be stored = Max Memory Location/Actual parameter stored in Each log =273030/4= 68257
Timelog Interval setting = 15 minutes
Log in one day = (60 /Timelog Interval setting) * 24 =(60/15)*24 = 96 Logs
Max Days = Maximum log that can be stored / log in one day = 68257 / 96 = 711 days = 1 Year & 11 Months = 23 Months.
Risbabh EM94-Z-V1-L-M, Panel Mount DC kWh Meter, Class 0.5, 50-150mV Shunt input, 60-300VDC, 2 Alarm/Pulse Outputs, RS485 & USB Comms, Single Line LCD Display,12-60V DC Aux Supply, Internal Logging
2 Pulse/Alarm Outputs
50-150mV Shunt Input, and nominal voltage 60-300VDC
RS 485 communication up to 57,600 bit/s
USB Port
8MB Internal Storage
4 x DC Measurement Only
The meter is intended for measuring, analysing and monitoring DC Power. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current,, energy, power.) from the measured signals.
Features :
96 x 96mm Panel Mount
Accuracy class 0.5
Simple Menu
RS 485 communication up to 57,600 bit/s
USB Comms
8MB Internal Logger
60-300VAC/DC power supply
Specification
Rishabh Part Number
EM94-Z-V1-L-M
Functions
kWh Meter, Energy Meter
Supply Voltage
60-300VAC/DC
Nominal Measurement Range
60-300VDC
Maximum Measurement Range
60-300VDC
Display
4 Line LCD
Pulse/Relay Output
2
Accuracy
Class 0.5 (Energy)
USB
YES
Real Time Clock
1min/month (30ppm)
Isolation
3.5kV
RS485 Modbus RTU
YES 57,600bps
Weight
450g
Certification
EN 61010-1 Installation Category III
Factory Pack Qty
1
Environment
IP54
Safety
Protection Class II
Enclosure Material
Mablex with fire protection to UL94-V-O. Self extinguishing
EnclosureSize
96 x 96mm x 83.5mm (72mm behind panel)
Terminals
Rising Cage 4mm² (12 AWG) cable max
Humidity
< 75% Non Condensing
Operating Temperature
-20 →+70 °C
Datasheet
Product Datasheet
Software
Software User Manual
Software Download Link
Application Notes
1)Reading Data from Registers -> Download file
2)Maximum Memory Size -> Read below
Max Available Memory Locations in 8MB Size = 273030
Actual parameter stored in Each log (Memory locations used) = Date +time+Number of parameter selected by user
Considering your example for 2 parameters:
Number of parameter selected by user = 2 (kwh & kVA)
Actual parameter stored in Each log = 1(Date) +1(time)+ 2 (Parameters) = 4 (memory locations used per log)
Maximum log that can be stored = Max Memory Location/Actual parameter stored in Each log =273030/4= 68257
Timelog Interval setting = 15 minutes
Log in one day = (60 /Timelog Interval setting) * 24 =(60/15)*24 = 96 Logs
Max Days = Maximum log that can be stored / log in one day = 68257 / 96 = 711 days = 1 Year & 11 Months = 23 Months.
BK3-P1, Indicator, 48x24mm, 100-240VAC, Pt100 RTD Input, -199.0-600 Deg C Display Range
3.5-digit displays suit most industries including Temperature, Humidity, Pressure (0.5s response)
Drip-proof / Dust-proof IP66 (front panel only)
UL/CE Approved
Each unit needs just 100.2 mm depth panel space
EC Compliant
Specification
Hanyoung Nux Part Number
BK3-P1
Control Output 1 (Heat)
N/A
Control Output 2 (Cool)
N/A
Input
P100 RTD (-199.0-600.0 Deg C)
Alarm
N/A
Option 1
N/A
Mounting Style
48 x 24mm Panel Mount
Supply Voltage
85 - 265VAC
Termination Style
Screw
Weight
250g
Factory Pack Qty
1
ROHS
Yes
UL
Yes
CE
Yes
Datasheet
BK3 Series Instruction Manual
Free Software
Hanyoung Nux TCS Software
Hanyoung Nux TCS Software User Manual
VX Series SB Driver (Windows 7) Not required for Windows 10 or 11
Fastron FRTD-Transmitter-0-200-420-24, Pt100 , 4-20mA Transmitter, 0 to 200 Deg C, 24VDC Supply
Class A Accuracy
Steel Insulated Cable
Low Long Term Drift
Rated for 0 to 220 Deg C Max
Spring Cable Connection
60mm Jaw Clip
Specification
Fastron Part Number
FRTD-Transmitter-0-200-420-24
Sensor Type
Pt100 to 4-20mA Transmitter
No of Wires
3
Shaft Length
N/A
Shaft Thickness
N/A
Accuracy
Class A
Temperature Range
0 to 200 Deg C
Span/ Zero Adjustment
YES
Weight
50g
Factory Pack Qty
1
Crydom ED24C5, EMR plug in Solid State Relay, 18-32VDC control, 5 Amp 24-280VAC output
Features
Ratings 5 Amp @ 24-280VAC
Plug in EMR relay style
Motor controller rated
SCR output for reliable AC switching
Multiple modules can be wired in parallel for higher currents
UL/CSA/VDE Approved, CE Compliant to EN60950-1
EMC compliant to Level 3
Epoxy free design
Spec
Crydom Part Number
ED24C5
Switching Type
AC Load
ROHS
Yes (Details)
Control Voltage
18-32VDC
Load Current
5 Amp DC
Surge Capability (10ms)
60 Amp DC
Special Feature
Plug in EMR style
Mounting Style
EMR Base
Load Voltage Range
24-280VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
38g
Factory Pack Qty
10
Datasheet
Product Datasheet
Socket
DRSED
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
TCR-L-3-K Temperature Controller, Analogue Dial, 96x96mm 230VAC, C/O Relay output, Type K Input, 0-400 Deg C
3-digit display (0.5s response)
Drip-proof / Dust-proof IP66 (front panel only)
Input signals can be converted to insulated ON/OFF Relay, output, Optional COOLING or time proprtional versions output available
Each unit needs just 75 mm depth panel space
Specification
Fastron Part Number
TCR-L-3-K
Control Output
Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)
Input
Type K Thermocouple (0-400 Deg C)
Control Mode
Time Proportional Control
Mounting Style
96x96mm Panel Mount
Control Range
0-400 Deg C
Supply Voltage
230VAC
Termination Style
Screw
Sampling Time
50ms
Weight
270g
Factory Pack Qty
1
Datasheet
TCR Datasheet and User Manual
Fastron Electronics AM5S-C-P5-D-N, 48x24mm Digital Totaliser 7kHz, NPN 5VDC, 22-60VAC/DC supply
Large 5 Digit 0.4 Inch LED Display
250mS Response Time
PC 94 UL V0
Input signals can be NPN, PNP, or 24VDC Pulses depending on the model used
Each unit needs just 48 x 24mm Panel Space
86.2mm Depth
Specification
Fastron Electronics Part Number
AM5S-C-P5-D-N
Input
NPN 5VDC
Measurement Range
0 - 7kHz
Operating Temperature
0 - 60°C
Load Voltage
22-60VAC/DC
Termination Style
Screw
Mounting Style
48 x 24mm Panel Mount
Case Material
PC - UL 94 V0
Safety Approvals
CE
Weight
320g
Factory Pack Qty
1
Datasheet
Product Datasheet
Application Notes
Panel Meters Blog Articles
Fastron FC5-W-1A-2-G-4 PID Controller, 24VDC with 2 x Relay Alarms, K,E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, 96x48mm,4-20mA Output
4-digit displays (0.5s response)
Drip-proof / Dust-proof IP66 (front panel only)
Input signals can be converted to insulated -0-10V, Relay, 12VDC (SSR) and 4 to 20 mA DC outputs available
Each unit needs just 75 mm depth panel space
Specification
Fastron Part Number
FC5-W-1A-2-G-4
Control Output
4-20mA
Input
Multirange Type E,J,N,T,S,R,B, Pt100, Cu50/Linear Current 4(0)-20mA/Linear Voltage 0-10(5)V
Option 1
2 x Relay Alarms standard (Excludes 96x48mm with SSR/Relay output)
Mounting Style
96x48mm Panel Mount
Supply Voltage
100 - 240VAC +/-10%
Termination Style
Screw
Sampling Time
100ms
Weight
150-270g
Factory Pack Qty
10
Datasheet
Datasheet
User Manual
Modbus Protocol
FC5 Communication Protocol
H-10-2-24, Split Core Hall Effect DC Current Transducer, 0-10 Amp DC, 4-20mA unipolar output, 31mm aperture, 24VDC supply
Compact and versatile Split Core DC current sensor, 0-10 Amp DC, 4-20mA Unipolar Output
Features
⌀31mm Aperture
Split Core
DC Unipolar Measurement
4-20mA analogue output
Busbar, or DIN Rail Mounting
Isolated plastic case recognised according to UL94-V0
Advantages
High isolation between primary and secondary circuits
Easy installation
DIN Rail Mount
Applications
-Automation Systems
Analogue current reading for remote monitoring (e.g. Motor)
-Data Loggers
Self Powered. Will not drain data logger batteries
-Panel Meters
Simple connection displays power consumption
Specification
Fastron Part Number
H-10-2-24
Technology
DC Hall Effect Current Transducer with Process Output
ROHS
Yes
Supply Voltage
24VDC
Nominal Current (DC)
0-10 Amp
Response Time
< 200mS
Output
Unipolar 4-20mA Analogue
Isolation
2.5kV (AC, 50Hz, 1 min)
Bandwidth
DC
Mounting Style
DIN Rail Mount
Operating Temperature Range
-40°C / 85°C
Accuracy
1%
Termination Style
Elevator Screw
Unit Weight
120g
Factory Pack Qty
6
Datasheet
Product Datasheet
TCR-L-3-PT HEATING Temperature Controller, Analogue Dial, 96x96mm 230VAC, C/O Relay output, PT100 RTD Input, 0-400 Deg C
3-digit display (0.5s response)
Drip-proof / Dust-proof IP66 (front panel only)
Input signals can be converted to insulated ON/OFF Relay, output, Optional COOLING or time proprtional versions output available
Each unit needs just 75 mm depth panel space
Specification
Fastron Part Number
TCR-L-3-PT
Control Output
Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)
Input
Pt100 RTD (0-400 Deg C)
Control Mode
Time Proportional Control
Mounting Style
96x96mm Panel Mount
Control Range
0-400 Deg C
Supply Voltage
230VAC
Termination Style
Screw
Sampling Time
50ms
Weight
270g
Factory Pack Qty
1
Datasheet
TCR Datasheet and User Manual
TCD-L-3-K HEATING Temp Controller, 96x96mm 230VAC, C/O Relay output, Type K Input. Encoder Control,amp; Digital Display, 0-999 Deg C
Pushbutton Encoder Setpoint
3-digit display (0.5s response)
Drip-proof / Dust-proof IP66 (front panel only)
Input signals can be converted to insulated ON/OFF Relay, output, Optional cooling or time proprtional versions output available
Each unit needs just 75 mm depth panel space
Specification
Fastron Part Number
TCD-L-3-K
Control Output
Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)
Input
Type K Thermocouple
Control Mode
Time Proportional Control
Control Range
0- 999 Deg C
Mounting Style
96x96mm Panel Mount
Supply Voltage
230VAC
Termination Style
Screw
Sampling Time
50ms
Weight
270g
Factory Pack Qty
1
Datasheet
TCD/TCR/FC5 Datasheet
TCD/TCR User Manual