Schurter 0090.0010 ASO 10.3x38mm GpV Fast Blow Solar Fuse 10Amp, 1000VDC, 20kA, IEC 61730-2
Features
Meets the new UL and IEC photovoltaic standards
UL Recognized for 1000 VDC
High breaking capacity of 20 kA @ 1000 VDC
Low min. interrupting rating of 1.35 x In
Meets the requirements of IEC 61730-2 for PV module safety
Applications
All photovoltaic applications
Inverters
Battery charge controllers
In-line protection
String fuses
Specification
Schurter Part Number
0090.0010
Fuse Type
I²t GpV Class Fast Blow
Nominal Voltage
1000VDC
I²t Rating (Pre-Arcing)
401 kA²/s
Nominal Current (DC)
10 Amp
Tested Breaking Capacity
20kA @1000VDC
Dimensions
10.3 x 38mm
Fuse Holder
FSO Fuse Holders
Mounting Style
Requires fuse holder
Operating Temperature Range
-40°C / 125°C
Watt Loss
1.76W
DC Breaking Capacity
20kA
Unit Weight
8g
Factory Pack Qty
10
Datasheet
Product Datasheet
Fuse Holder
FSO Fuse Holders
Schurter 0090.0012 ASO 10.3x38mm GpV Fast Blow Solar Fuse 12Amp, 1000VDC, 20kA, IEC 61730-2
Features
Meets the new UL and IEC photovoltaic standards
UL Recognized for 1000 VDC
High breaking capacity of 20 kA @ 1000 VDC
Low min. interrupting rating of 1.35 x In
Meets the requirements of IEC 61730-2 for PV module safety
Applications
All photovoltaic applications
Inverters
Battery charge controllers
In-line protection
String fuses
Specification
Schurter Part Number
0090.0012
Fuse Type
I²t GpV Class Fast Blow
Nominal Voltage
1000VDC
I²t Rating (Pre-Arcing)
642 kA²/s
Nominal Current (DC)
12 Amp
Tested Breaking Capacity
20kA @1000VDC
Dimensions
10.3 x 38mm
Fuse Holder
FSO Fuse Holders
Mounting Style
Requires fuse holder
Operating Temperature Range
-40°C / 125°C
Watt Loss
1.97W
DC Breaking Capacity
20kA
Unit Weight
8g
Factory Pack Qty
10
Datasheet
Product Datasheet
Fuse Holder
FSO Fuse Holders
Schurter 0090.0025 ASO 10.3x38mm GpV Fast Blow Solar Fuse 30Amp, 1000VDC, 20kA, IEC 61730-2
Features
Meets the new UL and IEC photovoltaic standards
UL Recognized for 1000 VDC
High breaking capacity of 20 kA @ 1000 VDC
Low min. interrupting rating of 1.35 x In
Meets the requirements of IEC 61730-2 for PV module safety
Applications
All photovoltaic applications
Inverters
Battery charge controllers
In-line protection
String fuses
Specification
Schurter Part Number
0090.0030
Fuse Type
I²t GpV Class Fast Blow
Nominal Voltage
1000VDC
I²t Rating (Pre-Arcing)
2679 kA²/s
Nominal Current (DC)
30 Amp
Tested Breaking Capacity
20kA @1000VDC
Dimensions
10.3 x 38mm
Fuse Holder
FSO Fuse Holders
Mounting Style
Requires fuse holder
Operating Temperature Range
-40°C / 125°C
Watt Loss
3.92W
DC Breaking Capacity
20kA
Unit Weight
8g
Factory Pack Qty
10
Datasheet
Product Datasheet
Compatible Fuse Holder
FSO Fuse Holders
Schurter 8020.2053 AEO 10.3x38mm Fast Blow Automotive Fuse 30Amp, 1000VDC, 20kA, IEC 61730-2
Features
UL Recognized for 1000 VDC, and 275VAC
High breaking capacity of 20 kA @ 1000 VDC, 10kA @ 175VAC
Low min. interrupting rating of 1.35 x In
Meets the requirements of IEC 61730-2 for PV module safety
Applications
All photovoltaic applications
Inverters
Battery charge controllers
In-line protection
String fuses
Specification
Schurter Part Number
8020.2053
Fuse Type
I²t GpV Class Automotive Fuse
Nominal Voltage
1000VDC, 275VAC
I²t Rating (Pre-Arcing)
3150 A²/s
Nominal Current (DC)
25 Amp
Tested Breaking Capacity
20kA @1000VDC 10kA @ 275VAC
Dimensions
10.3 x 38mm
Fuse Holder
FSO Fuse Holders
Mounting Style
Requires fuse holder
Operating Temperature Range
-40°C / 125°C
Watt Loss
1.8W
DC Breaking Capacity
20kA
Unit Weight
8g
Factory Pack Qty
10
Datasheet
Product Datasheet
Compatible Fuse Holder
FSO Fuse Holders
KW62-TT500N16KOF 900 Amp 130mm long Isolated Water Cooled SCR Module
Replacement to Semikron SKIW700/16
Nominal 1000 Amp RMS Output using TT500N16KOF
Nominal 1100 Amp RMS Output using MCC552-16
Comes with Brass inlet and outlet for hose, along with plug.
Pressure Tested to 300 mbar
110 Deg C Normally Closed Thermal switch included
Specification
Thermal Rating based on 25 Deg C max inlet water temperature, and 50 Deg C max Ambient
Type No
Litres/min
Device
Rcw deg C/W
mbar
kg
Continous Current (rms)
KW62-TT425N16KOF
2
50 x 92
0.055
50
2.7
750 Amp
4
50 x 92
0.042
190
850 Amp
Datasheet
KW62 Datasheet
TT425N16KOF
H71/110M + D53TP50D Three Phase Solid State Relay 4-32VDC Control, 3 x 13Amp, 48-530VAC Load
Ratings from 25A to 50 Amp @ 70-530 VAC
SCR output for heavy industrial loads
Zero voltage or Instantaneous turn-on outputs
UL/CE/ROHS Approved
IP20 Cover Available
AC & DC control types
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Specification
Crydom Part Number
H71/110M + D53TP50D
Switching Type
Zero Crossing
ROHS/CE/UL
Yes
Control Voltage
4-32VDC
Load Current
3 x 13 Amp (rms) per Phase @ 50 Deg C
Surge Capability
597 Amp (peak)
Special Feature
LED Status Indicator
Mounting Style
Din Rail Mount
Load Voltage Range
48-530VAC
EMC Compliant
Level 3
Dimensions
L:110mm x W:100mm x D:90mm
Termination Style
Screw
Weight
650g
Factory Pack Qty
10
Datasheet
H71 Datasheet
D53TP Series
Product Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
Fastron H31/110M-B + A53TP50D, Three Phase Solid State Relay with Heatsink 4-32VDC Control, 3 x 34Amp, 48-530VAC Load
Ratings from 25 to 120 Amp @ 70-480 VAC
SCR output for heavy industrial loads
Zero voltage or Instantaneous turn-on outputs
IP20 Cover Included
AC & DC control types
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Specification
Fastron Part Number
H31/110M-B + A53TP50D
Switching Type
Zero Crossing
ROHS/CE/UL
Yes
Control Voltage
90-280VAC
Load Current
3 x 34 Amp (rms)
Surge Capability
597 Amp (peak)
Special Feature
LED Status Indicator
Mounting Style
Panel Mount
Dimensions
L:110 x W:125 x D:180mm
Load Voltage Range
70-530VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
2kg
Factory Pack Qty
10
Datasheet
Product Datasheet
H31 Datasheet
Fastron HS103DR + FTH2553ZD3, 4-32VDC Control, 3 x 21Amp, 48-530VAC Load, LED Status Indicator - Phase Solid State Relays + Heatsink, with IP20 Cover
Ratings from 25A to 50 Amp @ 70-530 VAC
SCR output for heavy industrial loads
Zero voltage or Instantaneous turn-on outputs
UL/CE/ROHS Approved
IP20 Cover Available
AC & DC control types
Direct bond copper substrate
Direct power lead frame
Includes IP20 Cover
Specification
Crydom Part Number
HS103DR + FTH2553ZD3
Switching Type
Zero Crossing
ROHS/CE/UL
Yes
Control Voltage
3-32VDC
Load Current
3 x 18 Amp (rms) per Phase
Surge Capability
350 Amp (peak)
Special Feature
LED Status Indicator, with IP20 Cover
Mounting Style
Din Rail Mount
Load Voltage Range
48-530VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
900g
Factory Pack Qty
10
Datasheet
HS103DR
D53TP Series
Fastron HS103DR-FTH6053ZA4, Three Phase Solid State Relay 90-280VAC Control, 3 x 21Amp, 48-530VAC Load, LED Status Indicator, with IP20 Cover
Ratings from 25A to 70 Amp @ 70-530 VAC
SCR output for heavy industrial loads
Zero voltage or Instantaneous turn-on outputs
UL/CE/ROHS Approved
IP20 Cover Available
AC & DC control types
Direct bond copper substrate
Direct power lead frame
Includes IP20 Cover
Specification
Crydom Part Number
HS103DR + FTH6053ZD3
Switching Type
Zero Crossing
ROHS/CE/UL
Yes
Control Voltage
90-280VAC
Load Current
3 x 23 Amp (rms) per Phase
Surge Capability
597 Amp (peak)
Special Feature
LED Status Indicator, with IP20 Cover
Mounting Style
Din Rail Mount
Load Voltage Range
70-530VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
900g
Factory Pack Qty
10
Datasheet
HS103DR
Product Datasheet
LEM HO 250-S/SP33-1106, O/L Hall Effect Current Sensor, 250 Amp, 15 x 8mm Aperture, Vref = 1.65V, Panel Mount Open Loop AC/DC Hall Effect Sensor
Features
Open loop current transducer
Voltage output
Single power supply +3.3 V
Overcurrent detect 2.93 × IP N (peak value)
Galvanic separation between primary and secondary circuit
Low power consumption
Factory calibrated
Compact design for panel mounting
Aperture: 15 × 8 mm
Factory calibrated
Repositionabel mounting foot
Dedicated parameter settings available on request
Advantages
Low offset drift
Over-drivable Vref
Creepage / clearance > 8 mm
Fast response
Applications
AC variable speed and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Combiner box
Solar inverter on DC side of the inverter (MPPT).
Standards
IEC 61800-1: 1997
IEC 61800-2: 2015
IEC 61800-3: 2004
IEC 61800-5-1: 2007
IEC 62109-1: 2010
UL 508: 2013.
Application Domain
Industrial.
Specification
LEM Part Number
HO 250-S/SP33-1106
Technology
Open Loop Hall Effect
Aperture
15 x 8mm
ROHS
Yes
Supply Voltage
3.3 VDC
Load Current (RMS + DC)
250 Amp
Measurement Range
+/-625 Amp
Output
2.5 Vref
Isolation
4.3 kV
Bandwidth
DC-100 kHz
Mounting Style
Panel Mount
Operating Temperature Range
-40°C / 105°C
Accuracy
1%
Termination Style
JST B5B-PH type
Unit Weight
32g
Factory Pack Quantity
25
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
H7 Heatsink Profile 72.5mm x 140mm, Various Lengths cut to order, Milled or Raw Finish
Datasheet
Product Datasheet
Heatsink Data
New Heatsink Data Book
Old Heatsink databook with additional thermal data
H8 Heatsink Profile 72.5mm x 150mm, Various Lengths cut to order, Milled or Raw Finish
Datasheet
Product Datasheet
Heatsink Data
New Heatsink Data Book
Old Heatsink databook with additional thermal data