Schurter 4747.0000, Distribution Unit with IEC Appliance Inlet C14/M to 4 x C14/F Outlet, Snap-in Mounting, Front Side, Quick connect terminals 4.8 x 0.8 mm, 2mm panel Thickness
Features
1 x C14 Male in 4 x C14 Female out, Ganged Distribution Outlet
C14 Socket acc to IEC 60320-1
70 °C pin Temperature
Suitable for use in equipment according to IEC/UL 60950
Characteristics
UL 60320-1, CSA C22.2 no. 60320-1 (for hot conditions) pin-temperature 70 °C, 10A, Protection Class I
Types for enhanced glow wire test requirements acc. IEC 60695-2- 12 and -13 for the use in unattended household equipment acc. IEC 60335-1
Specification
Schurter Part Number
4747.0000
Rated Voltage
250V
Rated Current
10A (CE) 15A (UL/CSA)
No of Outlets
4
Operating Temperature
-25°C to 120°C
Filter Type
N/A
Fuse Holder
N/A
Line Switch
N/A
Mounting
Loose
Material
Thermoplastic, black, UL 94V-0
Termination Style
1 x C14 Male Inlet, 4 x Female C14 Outlet
Weight
550g
Factory Pack Qty
1
Protection Class
From front side IP30 acc. to IEC 60529
Isolation
2kV (L-N, L/N-E)
VDE/UL/CSA/CE/ROHS
Yes
Datasheet
Product Datasheet
Rishabh CT 75/5 Class 1 2.5VA 45/21(40) Current Transformer
Features
DIN Rail Mounting Clip Included
Built In Sealable Terminal Covers
Mounting Feet Supplied
Narrow Width (45mm)
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Rishabh Part Number
CT 75/5 Class 1 2.5VA 45/21 (40)
Technology
AC Current Transformer
Ratio
75/5
Aperture Size
⌀ 21mm or 20x10mm Busbar
VA Rating
2.5VA
Accuracy Class
Class 1
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Din Rail Mount
Operating Temperature Range
-30°C / 85°C
Continuous Current (max)
200Amp x 1.2
Termination Style
Screw
Unit Weight
300g
Factory Pack Qty
9
Datasheet
Product Datasheet
Crydom CWD2410, Solid State Relay, Single Phase 3-32VDC Control, 10A, 24-280VAC Load. High surge w/LED Indicator
Ratings from 25A to 125 Amp @ 24-280VAC
SCR output for heavy industrial loads
Zero voltage or instantaneous turn-on outputs
UL/CSA/VDE Approved, CE Compliant to EN60950-1
Improved SEMS screw and washer
Redesigned housing with anti-rotation barriers
AC & DC control types
Direct bond copper substrate
EMC compliant to Level 3
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
CWD2410
Switching Type
Zero Crossing
ROHS
Yes (Details)
Control Voltage
4-32VDC
Load Current
10 Amp (rms)
Surge Capability
400 Amp (peak)
Special Feature
LED Status Indicator, High Surge
Mounting Style
Panel Mount
Load Voltage Range
24-280VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
75g
Factory Pack Qty
20
Datasheet
Product Datasheet
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Equivalent Parts
CWD2450P for stocked equivalent
Fastron Electronics FESCT-19-100-0.333V, 100Amp measurement Split Core CT's, w/1M Flying leads, 19x19mm Aperture, 0.333v Class 1 Series Current Transformer
Features
Quick Release Split Core System
1m Flying Leads
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.60/3kV
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
FESSCT-19-100-0.333V
Technology
Split Core AC Current Transformer
Ratio
100/0.333V
Aperture Size
19 x 19mm
VA Rating
N/A
Accuracy Class
Class 1
Output
0.333VAC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 55°C
Continuous Current (max)
100Amp x 1.2
Termination Style
1M Twisted Pair 0.34mm^2
Unit Weight
350g
Factory Pack Qty
9
Datasheet
Product Datasheet
Application Notes
Installation Guide
Fastron Electronics FESCT-19-300-0.333V, 300Amp measurement Split Core CT's, w/1M Flying leads, 19x19mm Aperture, 0.333v Class 1 Series Current Transformer
Features
Quick Release Split Core System
1m Flying Leads
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.60/3kV
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
FESSCT-19-300-0.333V
Technology
Split Core AC Current Transformer
Ratio
300/0.333V
Aperture Size
19 x 19mm
VA Rating
N/A
Accuracy Class
Class 1
Output
0.333VAC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 55°C
Continuous Current (max)
300Amp x 1.2
Termination Style
1M Twisted Pair 0.34mm^2
Unit Weight
350g
Factory Pack Qty
9
Datasheet
Product Datasheet
Application Notes
Installation Guide
Gigavac GXL14C2AB, Latching Contactor SPST-NO, 350+ AMP, 12-800VDC, 24VDC Coil, 38cm Flying leads, SPST-NO Auxiliary Contact, IP67, IP69K, Low Side Drive Version
Features
Hermetically Sealed (Patented) rated to 175 Deg C
UL1604 for Class I & II Div 2 and Class III for use in hazardous locations
IP67 & IP69K
SAE J1171 External ignition protection
ISO8846 Protection against ignition around flammable gasses
CE Approved
High Efficiency Dual DC Coils - Very low 12,24,48VDC continuous coil power with no EMI emissions or cross-talk on your system control power
Ideal for battery powered systems or where low power is needed
PWM option provides additional drive control flexibility
Built in Coils suppression for all DC Coils
Flexible package for installation
Chassi level power terminals
Salt Fog MIL-STD-810
Specification
Gigavac Part Number
GXL14C2AB
Main Contact Type
SPST-NO
Auxiliary Contact Type
SPST-NO
Coil Voltage
24VDC (Low Side Drive, refer datasheet)
Load Current
350+ Amp
Mechanical Life @ 0 Amp
1,000,000 Operations
Dielectric at Sea Level (leakage <1mA)
2.2kV rms
Control Input Terminals
38cm Flying Leads
Aux Contact Terminals
38cm Flying Leads
Special Feature
Hermetically Seal rated to 175 Deg C
Mounting Style
Panel Mount (M5)
Load Voltage Range
12-800VDC
Standards
UL1604, IP67, IP69K, SAE J1171, ISO8846
Termination Style
M8
Unit Weight
440g
Factory Pack Qty
1
Datasheet
Product Datasheet
Kavlico (Sensata) 112CP3-9 Series Combined Pressure & Temperature Sensor
Features
Temperature and Pressure Measurement in one Package
Fast In Stream Temperature Measurement
Precise Superheat Measurement
Pressure Ranges 0-150psi through 0-650psi
Excellent Linearity
Wide Operating Temperature -55°C to 125°C
Applications
Air Conditioning and Refridgeration
Alternative Energy Management
Engine Controls and Monitors
Compressors and Pumps
Specification
Kavlico (Sensata) Part Number
112CP3-9
Pressure Range
9-510psi
Thermistor Resistance Range
10KΩ
Supply Voltage (Vcc)
4.5 to 5.5 Vdc
Output Voltage
0.5 to 4.5 Vdc typical
Supply Current
15mA max
Output Current
8mA
Output Load Range
10KΩ to 50KΩ
Response Time
10mS
Overvoltage Protection
16 Vdc
Reverse Voltage
-14 Vdc
Pressure Connection
M12 x 1.25 - 6g plated steel
Internal Seal
Neoprene with no thread Oring
Life Cycle
1 Million Cycles
Termination Style
4 Pin AMP Micro-Quadlok System Connector
Unit Weight
50g
Factory Pack Qty
100
Datasheet
Product Datasheet
TSG-V (ZKG-2000)High quality and high accuracy voltage regulator /Intelligent voltage regulator for SCR or SSR Control (choose one model)
Technical data:
Output impulse: Breadth value ≥ 3v, width ≥ 50us; S (when the load resistance is 20ohm)
Voltage setting range: 0-200v(or the voltage range you want)
Working environment: Temperature 0-50 degrees celcius, relative humidity does not exceed 85%, non-corrosive environment.
Power supply: AC 220v+/-15%, 50Hz+/-1Hz; About 3va
Size: TSG-V 48x48x88mm TSA-V96*96*100mm TSD-V72*72*100mm
TSG-2V 48*48*88(two voltage regulator in one unit)
Voltage setting range: 0-200v(or the voltage range you want)
Datasheet
Wiring Diagram
User Manual
TSG-V Manual
Required Accessories
Solid State relay and Heatsink is required sized large enough for the maximum continuous current of the load to be voltage regulated.
See here for complete list of possible combinations
Iskra Doo KNL18-10-240VAC Contactor
Capacitor duty contactors are designed to meet the requirements of capacitor duty applications. Contactors are fitted with a block of three auxiliary contacts connected in series with six quick discharge damping resistors, two per each phase. Peak current is limited to the value within the contactor making capacity.
Features :
High contact reliability at low voltages
High electrical and mechanical endurance and high switching capacity
Four and Three-pole contactors
Optional auxiliary contacts
Ratings from 6 Amp to 1000 Amp
UL, CSA Approved
Advantages :
Saves costs of expensive replacement
Long electrical life
Reduces watt losses during “ON” condition, saves energy
High safety
No risk of dangerous voltage
Less maintenance and downtime
Standard control voltages: 24 V 50/60 Hz, 240 V 50/60 Hz, 415 V 50/60 Hz
Specification
Iskra Doo Part Number
KNL18-10-240VAC
Functions
4 Pole Contactor
Nominal Voltage
230/400/500/690VAC @ 50/60Hz
Current Carrying Capacity as per UL
18 Amp Continuous @ 55 Deg C
Overload Capability
144(10s), 170(5s), 200(1s), 500(0.001s)
Auxiliary Contacts
4 x NO
Trip Delay Time
2-10ms
Electrical Life
200,000 Ops
Operating Temperature
-25 to 40 Deg C
Mechanical Operations
10.000,000 Ops
Control Voltage
240VAC
Power Dissipation
0.36W
Approvals
UL, CSA
Standards
IEC/EN 60947-4-1, AS/NZ 61009-1
Weight
200g
Enclosure Material
UL94
Factory Pack Qty
1
Datasheet
Product Datasheet
Contactor Catalogue
Iskra Contactor Catalogue
Iskra Doo KNL38-00-240VAC, AC Contactor 240/400/500/690V, Overload 304(10s), 320(5s), 350(1s), 900(0.001s) (each pole), 240VAC Control Voltage, 3 Pole 3 x NO, Nominal Current = 38 Amps
Capacitor duty contactors are designed to meet the requirements of capacitor duty applications. Contactors are fitted with a block of three auxiliary contacts connected in series with six quick discharge damping resistors, two per each phase. Peak current is limited to the value within the contactor making capacity.
Features :
High contact reliability at low voltages
High electrical and mechanical endurance and high switching capacity
Four and Three-pole contactors
Optional auxiliary contacts
Ratings from 6 Amp to 1000 Amp
UL, CSA Approved
Advantages :
Saves costs of expensive replacement
Long electrical life
Reduces watt losses during “ON” condition, saves energy
High safety
No risk of dangerous voltage
Less maintenance and downtime
Standard control voltages: 24 V 50/60 Hz, 240 V 50/60 Hz, 415 V 50/60 Hz
Specification
Iskra Doo Part Number
KNL38-00-240VAC
Functions
3 Pole Contactor (3 x NO)
Nominal Voltage
230/400/500/690VAC @ 50/60Hz
Current Carrying Capacity as per UL
38 Amp Continuous @ 55 Deg C
Overload Capability
304(10s), 320(5s), 350(1s), 900(0.001s)
Auxiliary Contacts
Optional Snap On 4 Pole NPL3
Trip Delay Time
2-10ms
Electrical Life
200,000 Ops
Operating Temperature
-25 to 55 Deg C
Mechanical Operations
10.000,000 Ops
Control Voltage
240VAC
Power Dissipation
2.3W
Approvals
UL, CSA
Standards
IEC/EN 60947-4-1, AS/NZ 61009-1
Weight
200g
Enclosure Material
UL94
Factory Pack Qty
1
Datasheet
Product Datasheet
Contactor Catalogue
Iskra Contactor Catalogue
Iskra Doo KNL75-11-240VAC, AC Contactor 240/400/500/690V, 3 Pole 3 x NO, with 1 x NO 1 x NC Aux Contacts, Nominal Current = 75 Amps, 240VAC Coil
Capacitor duty contactors are designed to meet the requirements of capacitor duty applications. Contactors are fitted with a block of three auxiliary contacts connected in series with six quick discharge damping resistors, two per each phase. Peak current is limited to the value within the contactor making capacity.
Features :
High contact reliability at low voltages
High electrical and mechanical endurance and high switching capacity
Four and Three-pole contactors
Optional auxiliary contacts
Ratings from 6 Amp to 1000 Amp
UL, CSA Approved
Advantages :
Saves costs of expensive replacement
Long electrical life
Reduces watt losses during “ON” condition, saves energy
High safety
No risk of dangerous voltage
Less maintenance and downtime
Standard control voltages: 24 V 50/60 Hz, 240 V 50/60 Hz, 415 V 50/60 Hz
Specification
Iskra Doo Part Number
KNL75-11-240VAC
Functions
3 Pole Contactor (3 x NO, with 1 x NO, 1 x NC Aux Contacts)
Nominal Voltage
230/400/500/690VAC @ 50/60Hz
Current Carrying Capacity as per UL
75 Amp Continuous @ 55 Deg C
Auxiliary Contacts
3 x NO, with 1 x NO, 1 x NC Aux Contacts (6 Amp) Optional NDL4-40, 4 Pole Snap On Aux Contacts
Trip Delay Time
2-10ms
Electrical Life
500,000 Ops
Operating Temperature
-25 to 55 Deg C
Mechanical Operations
10.000,000 Ops
Control Voltage
240VAC
Power Dissipation
6W per pole
Approvals
UL, CSA
Standards
IEC/EN 60947-4-1, AS/NZ 61009-1
Weight
950g
Enclosure Material
UL94
Factory Pack Qty
1
Datasheet
Product Datasheet
Contactor Catalogue
Iskra Contactor Catalogue
WL-PROG-CBL, Wi-LEM Mesh Gate Programmaing Cable, Micro Male USB to USB Male
Mesh Gate 6424-L:
Stand-alone gateway which manages the wireless network and collects data periodically sent by the EMN, Wi-Zone and/or Wi-Pulse devices. The Mesh Gate 6424-L family is split into three options according to the number of end nodes allowed in the network.
Mesh Node-L:
Network repeater allowing extented distance between the EMN, WiZone and/or Wi-Pulse devices and the Mesh Gate. A Mesh network provides redundant data paths to the gateway.
Datasheet
Product Datasheet
Specification
Features
Mesh, Star and Star-Mesh Network topologies
Interface RS 232 Modbus RTU (Gateway only) 1) RF frequency range 2)
2405 .. 2480
802.15.4
MHz
Programmable in 16 channels
Channel spacing 5 MHz
Unlicensed ISM band worldwide
Range between Mesh Node-L and Mesh Gate 6424-L
(indoor, line of sight)
140
m
Range to EMN (indoor, line of sight)
30
m
Data rate
250
kbps
Power supply voltage AC adaptor (see page two)
6 to 30
V DC
RF output power
10 dBm (10mW)
General data
PC
Power comsumption
200
TA
Ambient operating temperature
- 10 .. + 55
TS
Storage temperature
- 25 .. + 85
m
Mass Mesh Gate 6424-L
60
Mesh Node-L 151 g